INTERNAL CORRESPONDENCE PLAINTIFF'S EXHIBIT 5IE/AJCALS AND PLASTICS * ifjam?) .;>on : dhon Mr. W. T. Shelton Building 704-Shop Ms. M. M. Gilbert Mr. M. E. Perry Mr. H. L. Robinson Dr. F. G. Young P. C. SOX 8361, SOUTH CHAKiESTON, WEST VIRGINIA 35303 Dai? March 26, 1980 to.r,=.i r.p r---Pi Technical Center IH/EP :.-bect Asbestos Monitoring in Building 770 PROJECT Monitor exposure of insulators to asbestos during the removal of insulation tape from tubing in Room 237 of Building 770. DATE OF SURVEY March 19, 1980 DISCUSSION Services insulators R. E. Raines and J. W. Greenlee wore per sonal samplers while removing asbestos tape from various lines in Room 237 of Building 770. An area sample was also taken on a desk in the northwest corner of the room. Due to asbestos tape's disin clination to emit airborne asbestos fibers, the tape was not wetted with water during removal. However, respirators were worn and the area was barricaded in accordance with OSHA regulations. All samples indicated concentrations of less than 0.1 fibers/cubic centimer of air (f/cc). The current OSHA standard sets a ceiling limit for a 15-minute exposure of 10 f/cc and a limit of 2 f/cc for an eight-hour timeweighted average exposure. Further monitoring of asbestos tape removal will not be required. REPORT PREPARED BY W. F. Blythe, Jr. APPROVED BY G. F. Hurley WFBJr/sc UCC 024287