Document 7O3XvLmJKkm9J2VwVzXa3722g
11180
CHAPTER 47
"i- .'<1958 Guide
-Kiln Drying of.Lumber, by H. D. Tiemann (Lippincott,.1920).
Limitations of Diffusion Equations'Ll Drying,'by.O. A: Hougen, H. J. McCauley
and W. R. Marsball (Transactions, American Institute-of.Chemical-Engineers, Vol. 1,
1940, p.183).
.. . vG . ..
An Introduction to Convection Drying and Drying Calculations, by V. P. Victor (Heating and Ventilating, Vol. 41, Dec. 1944, p. 67).
Tobacco Curing, by R. R. Bennett and S. N. Hawks (University of North Carolina
Extension Circular SSB, Jan, 1949).
^
Principles of Burley Tobacco Barn .Operation,,by L. S. O'Bannon, University of Kentucky Bulletin SOI, May, 1947'.
Fuels for Curing Tobacco by E. M. Matthews, M. H. McVickar, and R. B. Davis, Jr. (Virginia Agricultural Experiment Station Bulletin No. 396, May, 1946).
" Heating Tobacco Barns with Stokers by N. C. Teter and E. G. Moss (North Caro lina Agricultural Experiment Station Bulletin No'. 352,' May, 1945).
Revised Psychrbmetric Chart Assists High'Temperature Design-by Irvin Lavine and 0. D. Sutherland (Chemical and Metallurgical Engineering, April, 1928, p. 226).
Mass Transfer in the Flow of .Gases through Granular, Solids Extended to Low Modified Reynolds Numbers, by G. R. Wilkie and O. ,A. Hoiigeri (Transactions, American Institute of Chemical Engineers; Vol. 41,945, p. 445).
'''Current Status of the Theory and Practice of Drying, by W.'R,..Marshall. (En gineering Experiment Station, University of Wisconsin Reprint No. 265).
. vi!
'A
-J'
CHAPTER 48
TRANSPORTATION AIR CONDITIONING
Railway Passenger Car Air Conditioning; Streetcar and Trolley Coach Heating and Ventilating; Passenger Bus Air Conditioning; Automobile Air Conditioning; Aircraft Air Conditioning; Ship Air Conditioning, Heating and Venti lating, Air Conditioned Space Treatment, Systems and Controls '
THE principles of air conditioning applying to stores, restaurants, hos pitals, theaters, and homes are applicable to railway passenger cars, passenger buses, automobiles, streetcars, trolley coaches, airplanes,.and ships. However, equipment used fpr mobile applications differs from that used for stationary purposes in that it must meet additional requirements. Equipment must be compact, accessible for quick inspection and servicing, light-weight and unaffected by vibration and impact. Freedom from vi bration which could be transmitted to supporting vehicle and thus to pas sengers, is essential.
RAILWAY PASSENGER CAR AIR CONDITIONING
The railway passenger car represents a very difficult air conditioning problem. Space is strictly limited so that all equipment and ducts must be reduced to minimum size. Electric power supply and water supply, also are limited. All equipment must withstand severe vibration and. shock, and must be very reliable since servicing points are frequently far apart.
During the heating season it is necessary to heat conventional cars with steam from the locomotive at pressures that may vary from 250 psig to only 5 or 10 psig on the last car in long trains. Passengers in window seats must sit only a few inches from cold outside walls and windows, and must also be very close to standing radiation installed along sides of cars., .Sud den changes in load may be caused.by changes in sun, wind, or train move ment. Even in coldest weather, outside doors must be opened frequently.
During the cooling season, the problem is further complicated by a high concentrated internal load due to the passengers. Also, air distribution problems are increased by low ceilings and short air throws.
Heating
The heating of passenger cars is accomplished by using a split system consisting of an overhead air circulating system with heating and cooling <h'\anC* standing radiation (floor heat) along car sides. The floor heaters, winch usually consist of finned tubing, may be made more efficient by usmg covers designed to increase gravity air circulation, and to direct the
srm air from finned heating surface along cold outside walls arid car windows In some new cars, wall convector panels are used and extend the H U mil- f car, with air intakes along the floor and outlets atwin-
ow all height and at window head height in dead-light panels. The heated the Passengers from cold outside walls, and the chimney effect of
panel duct increases air flow and improves heating surface efficiency,
finn *s suPPlied by introducing steam into an inner tube within a ea tube or by means of a separate steam-to-liquid heat exchanger.
1181