Document 7O0VrZXr7NOEwaYdengNpqDga
Z-47 BEV. lfr
AR226-2420
WASHINGTON WORKS P.O. Box 1217
PARKERSBURG, WV 26102-1217
DU PONT POLYMERS
TO: FROM:
C-8 FILE
R. J. ZIPFEh^).lu<6
CC: D. M. vonSchriltz
M. S. Eaton
T. L. Eichstadt
L. W. Goin
D. J. Doering
J. E. Crum
]. R. Lawson
R. A. Vaidya
J. B. Alien
W. P. Anderson
M. S. Deak M. G. McClusky
H. D. Ramsey
F.
Sepulveda
M. M. Stewart
J. F. Doughty A. J. Playtis
P. D. Spohn
D. A. Weber M. Kruempelman
November 18, 1991
Meeting Aim
C-8 INTERLABORATORY MEETING
Hill
An interlaboratory meeting with the Experimental
and Washington Works
Station,
purpose
of
the
meeting
laboratories was held was to gain an increased
on November 7, 1991. understanding of the
laboratory differences and to decide which laboratory will be used in
future for routine C-8 in water analyses.
CH2MThe
the
Meeting Conclusion
All three laboratories have good analytical procedures to
measure low levels of Hill methods are more
C-8 levels in water. "robust" resulting in
However, the CH2Ma lower detection
limit and reduced variability. Results from CH2MHILL and the
Exp. Sta. are in good agreement.
CH2M-H1M costs per sample are lower than those of the Experimental Station. Washington Works costs were not presented.
The Washington Works practice to increase the analytical
results from the Experimental Station by a factor of 1.4 will be
discontinued.
BETTER THINGS FOB BETTER LIVING
EID933880
C-8 11/18/91
CH2M-Hi"n procedures will be upgraded to more carefully utilize
C-8 recoveries from the C-8 in water blanks.
The use of a non-DuPont laboratory is of advantage if C-8 in
water results are published to any public organization.
CH2M-Hin will be used for future routine C-8 in water
determinations. Washington Works will continue to analyze C-8
in soil samples (required by EPA VI procedures).
Discussions
Both CH2M-Hin and the Experimental Station presented their
laboratory analytical procedures (both procedures currently on file) for
peer review. The Washington Works Analytical Laboratory uses the Experimental Station procedure.
Major procedural differences were:
(1) The CH2M-Hin Laboratory fully complies with the sampling protocol set by the EPA for environmental sampling. This protocol includes good QA/QC practices, improved sample container control, rigorous documentation of equipment calibrations, reduced ambient impurity contamination and the use of control samples. The Experimental Station laboratory does not have the volume of work to justify the
increased expense to the EPA procedures.
(2) The CH2M-Hin Laboratory procedure includes an extraction/sample wash step to remove impurities which could interfere with C-8 detection. In addition, in the extraction procedure CH2MHILL uses a 1000 ml sample
vs. 10 ml by the Exp. Sta. which allows the minimum detection limit to be improved by a factor of 10.
(3) The CH2M Hill procedure uses perfluorononanoic acid (C-9), perfluorodecanoic acid (C-10) & HH-eicosafluoroundecanoic acid (C-ll) as sample surrogates. CH2MHILL uses perfluoroheptanoic acid (C-7), 1,2-dichlorobenzene and 1,2,4-trichloro benzene as internal standards.The Experimental Station uses C-10 as an internal standard, and does not use surrogates. CH2M-Hin reports surrogate recovery results.
(4) The Experimental Station results are corrected for surrogate recovery where CH2M-Hin's results are not corrected. EPA prefers uncorrected results along with surrogate recovery results.
(5) The Experimental Station procedures uses C-8 in water blanks
for procedure calibration. CH2M-Hin will add this to their
method.
(6) Laboratory sample turnaround times are essentially equivalent.
EID933881
C-8 11/18/91
CH2M-Hin reported that their overall recovery of surrogates (C-9 & C-ll) to be approximately 60% (this includes variabilities from sample preparation, sampling, sample transportation, analytical procedure and sample .
analyses). Laboratory procedure variability at 3 sigma was 0.0066 parts per billion. Detection limit is 0.1 PPB
The Experimental Station reported their oveall recovery for a
C-8 spiking at 5.0 PPB to be 95%. They reported a laboratory procedure
variability at 3 sigma of 1.4 parts per billion. Detection limit is 1.0 PPB.
A discussion was held on the reasons why the Washington Works increases the Experimental Station results by a factor of 1.4. This was
done to account for the isomers of C-8 that were not reported with the main
C-8 peak. It was reported that we have no knowledge of how the isomers
behave in the environment and any attempt to correct would be misleading.
It was also pointed out that CH2M-Hin, and all other previously reported
C-8 in water results utilized only the main straight chain peak.
Therefore, to assumptions about unknown
1.4 factor was misleading data using the 1.4 factor
keep all of the data consistent and not make
peaks, it was concluded that the Washington Works
and would not be used. All previously reported
will be corrected.
Dan Weber presented our future C-8 in water and soil sampling needs for our VI plan and maintained planning (see attachment). This plan clearly showed that C-8 in water sampling would be high in 1992. The
Experimental Station could not support this high level of sampling.
CH2M-Hin indicated sample costs would be in the range of
$300.00 per sample. The Experimental Station reported that their costs would be higher than this. CH2M-Hin further stated that C-8 in soil samples would cost an additional $50.00 per sample. The Washington Works Process Laboratory will examine their costs vs CH2M-Hi^^/s.
A discussion was held on the laboratory results of the last round of sampling. Each laboratory was given 8 samples with four of these being unlabeled duplicates. Laboratory results are attached.
As can be seen, the laboratories reported values for their
unlabeled samples close to the values of the duplicate known sample. If one
corrects the CH2M-Hin results for surrogate recovery, their results are dose to those reported by the Experimental Station. Variability of CH2MHill's data is significantly less than the Experimental Station data.
Meeting attendees concluded that the results from both laboratories are valid and should be,used.
It was decided by all to use the CH2M-Hin Lab to analyze all
future routine C-8 in water samples. The Experimental Station would be used
if to occasionally cross check CH2M-Hin or for special samples. The
^
Washington Works Laboratory has been given to the EPA as the lab to analyze
a
the C-8 in soil samples for the sites VI. Future routine C-8 in soil
3
samples may be transferred to CH2M-Hin
Washington Works costs are too
8i
high.
-^
EID933882