Document 7MbGGm40xk3gBQLkndKmVed1j

CARBIDE INTERNAL CORRESPONDENCE .EMICALS AND PLASTICS INSTITUTE PUNT P. 0. BOX ?S3l. CHARLESTON, WEST VIRGINIA 25330 (Nwn) fit* Fred Williams `Ivhfoa Mliol Ooi* ' January 24, 1973 OWaiflaKflfl D*?A A nraring Ultr dot* Employee Relations Hygiene/Safety PY * Mr. R. 0. Midkiff Mr. R. E. Peele $ub|cr Asbestos Sampling Values 511 Insulation Fabrication Shop $L '< 'J&h 7u/***< /f7 tt% JLtf ~ * nvf!7i' f*4ts * Asbestos fiber counts for samples we have collected at the Plant 511 Insulation Fabrication Shop are submitted for your information. They may serve as guidance for any sampling program you may initiate and they should be valid as part of a records program. Sample No. Date Sampling Time, min Fiber Count/ml Sample-Job Description ^512-HHF-01 3-8-72 `/512-HHF-02 3-8-72 "'512-HHF-03 3-8-72 ''512-HHF-04 11-21-72 t *'512-HHF-05 11-21-72 ''512-HHF-06 11-21-72 ^ 512-HHF-07 11-21-72 S512-HHF-08 12-4-72 ^512-HHF-09 12-4-72 512-HHF-10 12-4-72 . 512-HHF-ll 12-4-72 512-HHF-12 12-4-72 ,, 512-HHF-13 12-4-72 - 512-HHF-14 12-4-72 512-HHF-15 12-4-72 15 5 15 6 6 9 15 15 15 9 15 4 13 1*1 ' 1*4 Too heavy to count * 61.5 ^ 24.5 min.^ 4.1 23.4 4.1 3.9 0.05 5.3 11.8' minj'' 27.8' 6.5 9.8 48.3' S. E. Painter - Dust collection removal for disposal. S. E. Painter - Dust -fca 9* *** collector wearing respirator. ' *t*> S. E. Painter - End of dust removal job. L. I. Mitchell - Butt sawing. L. I. Mitchell - Placing pairs of sawed blocks in cartons. H. Stanley - Janitor broom sweeping. H. E. Samples - Cementing pie-formed blocks. L. I. Mitchell - Off bearing south saw 1st cut. H. E. Witt - Separate sawed block - apply glue. Bad filter - not counted. * H. E. Samples - Removing glued blocks from stack-edging. H. E. Samples - Sawing block. L. I. Mitchell - Off bearing second cut - placing in carton. L. I. Mitchell - Unpacking a single carton - sawed 22 pcs. L. I. Mitchell - Filling carton with sawed blocks. // A.040O a. Hr. Fred Williams Page 2 January 24, 1973 All samples were collected on the person of the employee and each of them represents a peak exposure for the various work tasks. All work was Involved with asbestos containing KAYLO block materials. The problem area most deserving corrective measures is obviously the dumping procedure of the shop dust collecting facility. Excessive exposures are encountered in the handling, especially packing, of sawed block material. Exposure values have not been reported to the employees nor to shoo supervision. Very truly yours, HHFjllh H. H. Frazier X A048S7 UCC 006154