Document 7MD3mMVLL7E69q9E2bbErqw8o

Air System Equipment Air Filters Chicago r' Farr Cpinpany Manufacturing Engineers . P.O. Box 10187, Airport Station ; LOS Angeles 45, Calif. Manufactured under licence by Control Equipment Co., Ltd., Montreal, Canada FAR-AIR* FILTERS FOR ALL TYPES OF INDUSTRIAL USE Hew York THE FAR-AIR FILTERING PRINCIPLE . . . Herringbone-Crimp Media Design FAR-AIR Filters obtain maximum efficiency through their herringbonecrimp media design. Zinc electroplated wire mesh is formed in alternate layers of flat and herringbone-crimp to make channeled, triangular openings facing the incoming air flow. Design allows greater air flow, turbulence and effi ciency. Dirt builds up in the mesh on the entering side which diverts the air Progressive Loading Feature flow through the channels to clean mesh where the filtering process continues. The accompanying diagram of progres sive dirt loading shows why FAR-AIR filters have-higher performance,' larger dirt holding capacity, lower pressure loss, easier cleanability and reduced maintenance costs. FAR-AIR CAPACITIES . Recommended face velocities are 519 fpm although velocities up to 700 fpm may be used. Higher air velocities than recommended results 4n greater pressure loss and a shorter service period. Ve locities lower than 350 fpm are not recommended. The following chart can be used as a guide in estimating FAR-AIR Filter requirements. 4 in. filter thickness has twice the pressure loss of the 2 in. thick ness. ,NET FACE VEL. F.P.M. CAP. C.F.M. Per Sq. In. 346.. 390 ' 433 476 519 563 606 650 693 2.40 2.70 3.00 3.30 3.60 3.90 4.20 4.50 4.80, PRES SURE LOSS CLEAN V $44 0.06' 0.07' 0.09' 0.10' 0.12' 0-14' 0-16' O-IO' 0-21' NOMINAL FILTER SIZE Standard Stocked Filters Other Common Sues 16* x 20*| 16* x 25*| 20* x 20*| 20* x 25* 10* x 20*116* x 16*120* x 30*1 25* x 30* FILTER CAPACITY CUBIC FEET PER MINUTE 625 795 800 - 1020 360 485 700 895 900 1145 405 550 780 995 1000 .1275 450 610 860 1095 1100 1400 495 670 935 1195 1200 1530 540 730 1015 1290 ' 1300 1655 585 790 1090 1390 1400 1780 630 855 1170 1490 1500 1910 680 915 1250 1590 - 1600 2035 725 . 975 1235 1575 1390 1775 1545 . 1970 1700 2170 1855 . 2365 2010 2560 2165 2760 2320 2960 2475 3155 MEDIA DESIGNATION AND APPLICATION Type 44: 14 Jnesh zinc-electroplated steel screen.1 For Ventilation, paint, lint, ink, oil. Type 44F: Coated with vinyl or other special paint. For fume-resistant ap plications. Type 44G: Standard filter, unoiled. For grease arrestance. Type 44MZ: Screen painted with zinc chromate before and after assembly. Frame hot dip galvanized. Marine type--ventilation application. Type C4C4H: All copper media and filter frame. Corrosion-resistant and water elimination applications. Type A4A4: All aluminum media and filter frame. Stainless steel and monel filters for special applications can be * Trade Mark Reg. supplied on special order. 1196 Air System Equipment Air Filters Chicago ' Farr Company Manufacturing Engineers P.O. Box 101877 Airport Station Los Angles 45,-Galif. Manufactured under license by Control Equipment Co.t Ltd^ Montreal, Canada New York HOLDING FRAMES AND DIMENSIONS FAR-AIR holding frames are made from 16 gage steel and have a baked enamel finish. Felt stripping around the inside flange assures tight filter fit and prevents air by-pass. Frames are' interlocking and easily bolt together to form a rigid framework. Calking be tween frames in a bank is unnecessary. Clips hold filters firmly in place. Brae-: ing is not needed in banks up to 5 filters high by 6 filters wide. Instruction sheets are included in every shipment. STANDARD STOCKED SIZES (Actual) V and 4' Thickness FILTERS HOLDING FRAMES Type'44 and 44H* Shipping Weight (lbs.) 15 X 191' X 244' 1M X 191' 191 X 241' 4 114 114 13 * Includes handles Shipping Weight (lbe.) 16 X 20' 16X25' 20 X20' 20 X 25' 4f 54 84 6 FAR-AIR Filters and Holding Frames can be furnished in practically any size to meet exact specifications. Sizes over 25 in. X 30 in. are not recommended, however, as they are difficult to handle. HOW TO SPECIFY STANDARD TYPE 44 FILTERS & FRAMES Filter Bhall be permanent, impinge ment, washable, all metal, panel type. Media shall be zinc electroplated, 14 mesh steel screen, arranged in alternate layers of flat and herringbone-crimped screens, so that at no point is air flow restricted to flow through the screen, 4 layejs of each per inch, J-in. rod reinforced, and enclosed in a frame of 16 gage steel with flush mitered comers. Resistance to air flow of a clean filter shall not exceed 0.12 in. w. g. at 3.6 cfm per square inch of net face area. Holding frames shall be factory built on 16 gage steel "T" section, bonderized and bake enameled, with felt air seal, interlocking edges, and filter locking device. Filters shall be Far-Air Type 44 and frames shall be Far-Air Standard Inter locking as manufactured by Farr Com pany, Los Angeles 45, California. SELF WASHING FILTERS GREASE ELIMINATORS These completely automatic units wash and re-oil themselves on any frequency cycle desired. Each is made up from 4 in. thick corrosion-resistant filters in combination to meet any cfm require ment. Washing water and contami nated oil is immediately flushed away, eliminating messy sludge and oil sumps. There is no oil entrainment. Each unit has _ a safety deluge valve that auto matically prevents fire from passing the unit. Installation is simple and inexpensive. FAR-AIR Grease Eliminators consist of two standard filters in a special adapter with drip pan. These units halt the deposit of highly combustible grease and lint in the air ducts, reduce maintenance, protect blower and fan, provide better ventilation and sanita tion. Available in sizes and types to meet any cfm requirement. Full catalog and technical information on any FAR-AIR product is available on request ... or see Sweet's Architec tural File. 1197