Document 7M1r9j6vMwyL3X7VeaovmMOKR

-2 I have attached a summary of a recent presentation given by Roger Hatton at Texas Eastern as well as a booklet on Turblnol 1122 and 1221 (comparing to our former PCB product, Turblnol 153)* This presentation is particularly appropriate to send to you since It is a summary of the salient points from a product and customer standpoint. The trial commitment from Texas Eastern is the culmination of a year's work by Roger and $ , .John Prederlksen. Potential Turblnol business is 100 000 You will be receiving our "plan of attack" on the Turblnol program sb soon aB the '73 Marketing Plan ie published. We will be asking for your help soon in contacting those customers (primarily utilities) who have a OE large (Series 7000) gas turbine on order for late 1973 or 1974 delivery. Jim Bryant has now assumed sales responsibility for General Electric in the turbine area and we will be trying to gain preference for our Turbinols over Stauffer's Fyrquel R ft 0 turbine lubri-- cants at both GE and the customer in order to "lock in" as many turbines as possible. ., We will be sending out additional Turblnol information, a marketing strategy and a OE purchaser liBt, in the near future. We will aBk for and will appreciate your continuing help to make the Turblnol program a success. If you have questions or comments concerning our plans or the attached information, please feel free to contact us. /pep Attachments J. H. Davidson IRAN ooaois HARTOLDMON0040894 Distribution J. Armentor R. S. Bevacqua C. Boutin J. 0. Bryant R. J. Christman C. L. Clay P. D. Craeka H. R. Ford J. 0. Frederlksen D. R. Hansen L. T. Johnson J. A. Krlss D. H. Lewis M. L. Marcum D. L. Mellon B. 0. Moore W. C. Moore ' R. K. Puckett J. S. Pullman O.0. Reed H. J. Richardson J. J. Roder C. F. Seger P. L. Slayton W. H. Slowlkowskl R. V. Weyland 1460 1550 1800 1650 1460 1070 1010 1070 1460 1800 1650 1800 1180 1070 1010 1940 1210 1070 1650 1410 1410 04NN 1010 1650 1010 1180 TRAN 003016 HARTOLDMON0040895 Indusi rial fluids V________________________________________ J A REVIEW OP MONSANTO'S PIRE RESISTANT TURBINE LUBRICANTS PROGRAM FOR TEXAS EASTERN TRANSMISSION CORP. January 11, 1973 REH/pep TRAN 003017 Monsanto HARTOLDMON0040896 (2) Program Goals To provide fire resistant turbine lubricants which offer - maximum cost/performance - long term supply - environmental acceptability To verify above In full scale operations TRAN 003018 HARTOLDMON0040897 I Ci Program Status Two basic lubricants developed - Turblnol 1122 150 SUS at 1009F. -20F. pour point 1.17 specific gravity - Turblnol 1223 220 SUS at 100P. -5^. pour point l.lU specific gravity Stability Oxidation-Corrosion Tests Show lower acid number rise and less solids formation in severe tests (3^7P./168 hr.) Confirmed in NRC (National Research Council of Canada) and OE tests - Alcor Deposition Test Form less tube deposits at ^50-550P. Confirmed In NRC tests - Fullers Earth filtration Additives not completely removed, acidity can be reduced TRAN 003019 HARTOLDMON0040898 (4 i Lubricating Ability - Bench teste Equivalent or better than turbine lube oil and other phosphate esters - Slow Speed tests OE work shows these equal to competitive phosphate esters, better than petroleum oil ' - Ryder Gear testa Equal to or better than other phosphate esters Rust Prevention - Pass ASTM standard rust teste with distilled water - Turblnol 1122 passes sea water test (24 hr.) - Turblnol 1122 passes "film tenacity test" Foaming Characteristics - Low foaming results In ASTM tests Materials Compatibility Metals No problem with ordinary metals of construction 003020 TRAN HARTOLDMON0040899 Non metalllcs No problems with organic materials normally used for phosphate ester fluids Other fluids Compatible with competitive phosphate stars Compatible with Turblnol 153 Limited solubility In petroleum oil and vice versa (5) h. ]> TfiA^ 003021 HARTOLDMON0040900 I Program Statu Trans Canada Pipe Lines Field Teat Turbinol 1122 Canadian Westlnghouse turbine - DeLaval booster Test started November 25, 1972 24 Hour/Day operation Test goal - 8,000 hours Results to date - Excellent performance A alight foaming problem held under control by defoamer addition - Fluid analyses show no change in fluid properties (6) TRAN 003022 HARTOLDMON0040901 Advantages to Texas Eastern In use of Monsanto Turblnol lubricants - Supply Raw materials (synthetic organlca) Phosphate esters Control raw material supply baclc to phosphorus - Stability Longer fluid life Less maintenance due to cleaner operation (less deposit formation) - Safety Fire resistance Very low toxicity levels - Support Sample analysis program Technical experience TRAM 00302* HARTOLDMON0040903