Document 71x4Rm1Jppj3k3J52GQvjwq8e

Keloinator Corp. Air Conditioning CONDENSING UNITS* Kelvinator offers a complete line of.air cooled and water cooled condensing units; ranging in the air cooled series from J6hp.`~ to 2 hp., and in the water cooled units from hp. to 20 hp. In its more than 20 years of refrigeration engineering and research, Kelvinator has + developed condensing unit design and con struction which is unparalleled in the industry. Construction throughout is of * highest quality, in conformity with the best engineering practice, and each unit has been specially devised for the par ticular requirements of its job. WATER COOLED UNITS Model No. WG633H WH650H WF675H WK6100H WR6150H WY6200H WT6300H WU6500H WU6750H WU61000H WV6I500H WV62000H RP. 1 Phase A.C. or D.C. Vi % 1 V/i 2 3 5 7% 10 15 20 No. of Cyls. 2 2 2 2 2 2 2 2 2 2 4 4 R.PM. 365 410 400 400 200 330 300 360 500 650 500 650 Refrigeration Capacity Tons per 24 Hr*.' .35 .57 .79 1.25 1.60 2.25 3.0 5.7 7.9 10.0 15.9 20.0 Overall Dimensions (Inches) Width Depth Height 25% 29 30'/, 35 40 40 44 62 72 72 93'/, 93'/. 14'/. 15% 19% 19% 22% 22'/, 25 26 27'/i 27% 31 31- 18% 19% 22% 22% 26% 27% -29% 36 46% . 46% 4o 46. 'Approximate capacity in tons based on 80F. Condensing water inlet temperature and 37 lb., average .gauge suction pressure at compressor inlet AIR COOLED--1935 Line--600 SERIES--Condensing Units G633H H650H X 2 315 Vi 2 340 .262 .40 25 29 17 19% 17% 19% . F675H % 2 330 .60 31% 24% 21% K6I00H 1 2 330 .92 35 24 22% R6I50H 1 Vi 2 310 I.l5t 40 28% 26% . Y6200H 2 2 280 1.55 40 28% 27% 'Approximate capacity in tons based on 90F. Condensing air temperature and 37 lb. average gauge suction pressure at compressor inlet tBased on 35 lb. average suction pressure at compressor inlet BOILER-BURNER Kelvinator Boiler-Burner Unit offers the heating engineer a compact unit built of welded steel and thoroughly insulated. Exterior metal jacket is rust-proofed, finished with light gray lacquer and trimmed in polished chromium. Outstanding boiler features are cylindrical combustion chamber, single pass tube bank, spiral bafflles and thorough insulation. Burner features include noiseless, self-priming, non pulsating pump, large capacity, easily cleaned strainer, adjustable air shutter, noiseless fan design. Air turbulator cast inside air supply tube and advanced construction of ignition ^ transformer to supply very hot spark. 736 Keloinator Corp. Air Conditioning and Automatic Heating BOILER BURNER UNITS Model i ICB-1 Fuel Oil Capacity Cals, per Hour .85-132 Sa. Ft. Radiation Steam: 420-600 Hot Water: 670-690 -KB-2 1.5--2.5-- Steam: 600-1000 -Hot Water:- 1000-1600 KB-3 2.5-4 Steam: 1000-1600 Hot Water: 1600-2560 KJB-4 4-6.5 Steam: 1600-2600 Hot Water: 2560-4150 Motor Split* Phase Type Electrical Character istics Ignition Control Fuel Atomization Fuel Oil Require ments 110 V. A.C. 1/8 hp. 6o cycles Continuous Penn Electric Mechanical AOBA No. 1. Electric Switch Co. Pressure 2 or 3 Spark Line Voltage Continuous Penn Electric Mechanical AOBA No. 1. 1/8 hp. -110 V. A.C.- -Electric - Switch Co.- - -Pressure------ - -2 or 3 - 60 cycles Spark Line Voltage 110 V. A.C. 1/6 hP. 60 cycles Continuous Penn Electric Mechanical AOBA No. 1. Electric Switch Co. Pressure 2 or 3 Spark Line Voltage 110 V. A.C. 1/6 hp. 60 cycles Continuous Penn Electric Electric Switch Co. Spark Line Voltage Mechanical AOBA No. 1. Pressure 2 or 3 CONVERSION TYPE UNITS Kelvinator Conversion Type Pressure Burner Units for conversion of existing heating plants feature advanced design for long life, economy and trouble-free heating service. Features are: fuel control unit, noiseless, self - priming, non - pulsating pump, adjustable air shutter, scientific fan and housing construction for noiseless operation, directly connected motor with overload protection, air turbulator for complete combustion. These and other features indicate the thoroughness with which Kelvinator adheres to the best engineering practice. PRESSURE TYPE CONVERSION UNITS Fuel Oil Mode) cgty per Hour So. Ft. Radiation Motor Repulsion* Induction Type Electrical Character istics Ignition Control Fuel Atomization Fuel Oil Require ments Steam: 450-750 K-l l%-2% Hot Water: 750-1250 1/6 hp. MOV. A.C. 60 cycles Intermittent Minneapolis* or continuous Honeywell Electric Low Voltage Spark R-t03-l Mechanical Pressure AOBA No. 1. 2 or 3 K-2 Steam: 750-1250 2%-4% Hot Water: 1250-2083 1/6 hp. 110 V. A.C. - 60 cycles Intermittent or continuous Electric Spark MinneapolisHoneywel! Low Voltage R-103-1 Mechanical Pressure AOBA No. 1. 2 or 3 K-3 Steam: 1250-2000 4%-6% Hot Water: 2083-3333 1/6 hp. I10V.A.C. 60 cycles Intermittent or continuous Electric Spark MinneapolisHoneywell Low Voltage R-103-1 Mechanical Pressure AOBA No. 1. 2 or 3 737