Document 71w22GB8JKja4bOjj70LpVpq6

Lebanon Boiler Worlds Boilers Lebanon Boiler Works J. K. PETTY & CO., Inc., Proprietors 1242 Buttonwood Street - Lebanon, Pa. 39 Cortlandt St., N. Y. Sales Offices Harrison Bldg., Philadelphia Boilers THE WM. H. PAGE BOILER CO. General Office: 58 West 40th Street, NEW YORK Branches: 123 Beverly Street, Boston Rose Building, Cleveland 1718 Sansom Street, Philadelphia Factory: Meadville, Pa. Manufacturerm of a Complete Line of Round and Square Steam and Hot Water Boilere L-O Oil Burning Setting Lebanon L-O Boiler Steam Radiation Capacity Blr No. L-21 L-22 L-23 L-24 L-25 L-26 L-27 L-28 L-29 L-210 L-211 Shell Dimensions WxHxL 44" x 61 "x 8'-3 50" x 68" x 9'-0" 56" x 74" x lO'-Q" 62" x 80" x l0'-0" 62" x 82" x l2'-0" 68" x 87" x 11'-0" 68" x 87" x 13'--0n 68" x 93" x I3,-0" 74 x 95" x l4'-0" 74"x 99"xl5,-0" 74" i 103" x !6'-0" Steam Radiation (Sq. Ft.) 4100 5600 7800 10200 12600 15100 17700 20100 22900 26200 30700 Built alto in Power Type front IS to SO H. P. Lebanon "Rediset" H. R. T. Boiler. High Pressure and Heating up to 400 H. 'P..Units 318 "Lebanon Improved" H. R. T-. Boiler Brickset Type Monarch Up-Draft Smokeless Monarch Regular Type, Sectional View jMonarch Sectional Steam and Water Boilers Dimensions and Ratings Size of < Inches Area of Sq. Ft. Height All. lr Steam W id th All, In Steam W idth All, In Water Total I Inches -1 | S* _S f.Etu jj.ELi. l z (jrSJT JlO Jl <5-5 Ji *3 is! M C d ,1 ss fc C -s . II&.S cn<L 604 850 605 1075 606 1300 607 1525 608 1750 650 22x20 850 22x26% 1050 22x32V* 1250 22*39'/s 1450 22x45% 3.06 60% 39% 52 884.03 5.00 5.98 60% 39'/. 39% 391/* 52 52 52 6.95 60'/, 391/* 52 35 34 41 2-3 10 35 40Va 41 2-3 to 35 . 46% 41 2-3 10 35 53% 41 2-3 10 35 59% 41 2-3 10 504 . 505 1600 2050 1200 1600 28x2414 28x33'/s 4.82 6.45 73 73 SB45% ' 45% 41 41 43>/, 51 2-5 13 52 51 2-5 13 506 2500 2000 28x41% 8.07 73 45% 64% 41 60% 51 2-5 13 507 2950 2400 28x49% 9.70 73 451/4 64% 41 68% 51 2-5 13 508 3400 509 3850 2800 3200 28x58V* 28x66% 11.32 12.% 73 73 45% 45% 64% 64% 41 41 77>/. 51 2-5 13 51 2-5 13 510 4300 3600 28x66% 14.58 73 45% 64% 41 93% 51 2-5 13 511 4750 4000 16.21 73 45% 64% 41 102% 51 2-5 13 512 5200 4400 2flx66V8 17.84 , 73 45'/, 64'/, 41. IIOVb 51 2-5 13 405 3400 406 . 4200 407 5000 408 5800 409 6600 410 7400 411 8200 412 9000 413 . 9800 414 10600 415 11400 .416 12200 . 2400 3000 3600 4200 4800 5400 6000 6600 7200 7800 8400 9000 40x33'/b 40x41% 40x49% 40x58% 40x66Va 40x75 40x83% 40x9 iy* 40x915/* 40x9 P/i 40x9 P/* 40x9P/* 9.20 H.52 13.85 16.18 18.50 20.82 23.13 25.50 27.81 30.14 32.47 34.79 81 61 61 81 81 81 81 81 81 81 81 81 59% IV/i 55 52 58 2-5 21 I591/* 59% 59% 55 55 55 59% 59% 7722%%. 55 55 60% 58 2-5 21 68% 58 2-5 21 sa 58 2-5 21 58 2-5 21 93V* 58 2-5 21 59% 72% 55 102% 58 3-5 21 59'/* TVh 55 uo% 58 3-5 21 59*/* n'/f 55 119 58 3-5 21 59'/, nh 55 127% 58 3-5 21 59% 72% 55 135% 58 3-5 21 591/4 72V, 55 144% 58 3-5 21 Monarch Boilers are built in conformity with the Boiler Code of the American Society of Mechanical Engineers. 'Commercial Ratings, as given, are derived from tests made in accordance with the American Societt op Heattnq and Ventilating Engineers' Low-Pressure Boiler Code, Revision of 1924. Page Safe Ratings are conservatively made, derived from careful and exhaustive tests, during years of service under every condition--which proved their safety--and are based on an 8-hour firing period. Ratings are based on a standard of 2 lb. pressure maintained at the boiler for steam and 180 deg. for hot water. All piping (mains and risers, flows and returns) is to be figured as radiating surface in addition to the direct and indirect radiation attached to same. (Bridgewall sections are furnished for shortening grates. Grate areas as given above are for entire length of boilers, but unless otherwise ordered, bridgewall section will be dipped with boilers larger than No. 509 and No. 412 to reduce grate to length in table of dimensions. tThese,boilers can also be furnished with header connections, and in both up-draft and down-draft smokeless types.