Document 71w22GB8JKja4bOjj70LpVpq6
Lebanon Boiler Worlds
Boilers
Lebanon Boiler Works
J. K. PETTY & CO., Inc., Proprietors
1242 Buttonwood Street - Lebanon, Pa.
39 Cortlandt St., N. Y.
Sales Offices
Harrison Bldg., Philadelphia
Boilers
THE WM. H. PAGE BOILER CO.
General Office: 58 West 40th Street, NEW YORK
Branches: 123 Beverly Street, Boston Rose Building, Cleveland
1718 Sansom Street, Philadelphia Factory: Meadville, Pa.
Manufacturerm of a Complete Line of Round and Square Steam and Hot Water Boilere
L-O Oil Burning Setting
Lebanon L-O Boiler
Steam Radiation Capacity
Blr No.
L-21 L-22 L-23 L-24 L-25 L-26 L-27 L-28 L-29 L-210 L-211
Shell Dimensions WxHxL
44" x 61 "x 8'-3 50" x 68" x 9'-0" 56" x 74" x lO'-Q" 62" x 80" x l0'-0" 62" x 82" x l2'-0" 68" x 87" x 11'-0" 68" x 87" x 13'--0n 68" x 93" x I3,-0" 74 x 95" x l4'-0" 74"x 99"xl5,-0" 74" i 103" x !6'-0"
Steam Radiation (Sq. Ft.)
4100 5600 7800 10200 12600 15100 17700 20100 22900 26200 30700
Built alto in Power Type front IS to SO H. P.
Lebanon "Rediset" H. R. T. Boiler. High Pressure and Heating up to 400 H. 'P..Units
318
"Lebanon Improved" H. R. T-. Boiler Brickset Type
Monarch Up-Draft Smokeless
Monarch Regular Type, Sectional View
jMonarch Sectional Steam and Water Boilers
Dimensions and Ratings
Size of < Inches Area of Sq. Ft. Height
All. lr
Steam W id th
All, In
Steam W idth
All, In Water Total I
Inches
-1
|
S* _S f.Etu jj.ELi. l
z (jrSJT
JlO
Jl
<5-5
Ji
*3 is!
M C
d ,1
ss
fc C -s .
II&.S cn<L
604 850 605 1075 606 1300 607 1525 608 1750
650 22x20
850 22x26% 1050 22x32V* 1250 22*39'/s 1450 22x45%
3.06 60% 39% 52
884.03
5.00 5.98
60%
39'/.
39% 391/*
52 52
52
6.95 60'/, 391/* 52
35 34
41 2-3 10
35 40Va 41 2-3 to
35 . 46% 41 2-3 10
35 53% 41 2-3 10
35 59% 41 2-3 10
504 . 505
1600 2050
1200 1600
28x2414 28x33'/s
4.82 6.45
73 73
SB45%
' 45%
41 41
43>/, 51 2-5 13 52 51 2-5 13
506 2500
2000
28x41%
8.07 73
45% 64% 41
60% 51 2-5 13
507 2950
2400
28x49%
9.70 73
451/4 64% 41
68% 51 2-5 13
508 3400 509 3850
2800 3200
28x58V* 28x66%
11.32 12.%
73 73
45% 45%
64% 64%
41 41
77>/. 51 2-5 13 51 2-5 13
510 4300
3600
28x66%
14.58 73
45% 64% 41
93% 51 2-5 13
511 4750 4000
16.21
73
45% 64% 41 102% 51 2-5 13
512 5200
4400
2flx66V8
17.84 , 73
45'/, 64'/, 41. IIOVb 51 2-5 13
405 3400 406 . 4200 407 5000 408 5800 409 6600 410 7400 411 8200 412 9000 413 . 9800 414 10600
415 11400 .416 12200 .
2400
3000 3600 4200
4800 5400 6000
6600 7200
7800 8400 9000
40x33'/b 40x41% 40x49%
40x58% 40x66Va 40x75 40x83% 40x9 iy* 40x915/* 40x9 P/i 40x9 P/* 40x9P/*
9.20
H.52
13.85 16.18 18.50
20.82 23.13 25.50 27.81 30.14
32.47 34.79
81 61 61
81 81
81 81
81 81 81
81 81
59% IV/i 55
52
58 2-5 21
I591/*
59% 59%
55
55 55
59% 59%
7722%%.
55 55
60% 58 2-5 21 68% 58 2-5 21
sa 58 2-5 21 58 2-5 21 93V* 58 2-5 21
59% 72% 55 102% 58 3-5 21
59'/* TVh 55 uo% 58 3-5 21
59*/* n'/f 55 119
58 3-5 21
59'/, nh 55 127% 58 3-5 21
59% 72% 55 135% 58 3-5 21
591/4 72V, 55 144% 58 3-5 21
Monarch Boilers are built in conformity with the Boiler Code of the American Society of Mechanical Engineers. 'Commercial Ratings, as given, are derived from tests made in accordance with the American Societt op Heattnq
and Ventilating Engineers' Low-Pressure Boiler Code, Revision of 1924. Page Safe Ratings are conservatively made, derived from careful and exhaustive tests, during years of service under
every condition--which proved their safety--and are based on an 8-hour firing period. Ratings are based on a standard of 2 lb. pressure maintained at the boiler for steam and 180 deg. for hot water.
All piping (mains and risers, flows and returns) is to be figured as radiating surface in addition to the direct and indirect
radiation attached to same. (Bridgewall sections are furnished for shortening grates. Grate areas as given above are for entire length of boilers, but
unless otherwise ordered, bridgewall section will be dipped with boilers larger than No. 509 and No. 412 to reduce grate to length in table of dimensions.
tThese,boilers can also be furnished with header connections, and in both up-draft and down-draft smokeless types.