Document 71KJ6OkaBNo001VXg4OY5rbo8

rkotf- v`tr /it 6" Health & Safety Management, Inc. Safety Industrial Hygiene Fire P. 0. Box 693 Nederland, Texas 77627 (409) 724-2882 11821 MO East, Suite 160 Houston, Texas 77029 (713)455-7227 June 15. 1988 Proler International Corp. 7501 Wallisville Road Houston. Texas 77001 Attn: Mr. Mike Mitchum Dear Mr. Mitchum. The enclosed report is a draft of the results of bulk sampling at Shell Oil in Deer Park, Texas to determine the presence of asbestos in the areas to be demolished by Proler International Corp. Asbestos insulation in the "G" areas, which are to be demolished, has been abated and there is some evidence of encapsulation. There is: however, some equipment in the demolition areas which has not had the asbestos insulation removed. Eight random bulk samples were taken in the G-200 area on June 15, 1988. Five of these samples contained chrysotile and/or amosite asbestos, ranging from 1% to 40%. It would be difficult to certify some of this material as hazard free for transportation unless it were transported in a sealed container. The data sheets, laboratory results, conclusions and recommendations should provide a basis for planning of activities and the safest procedure to follow. Please advise if we may assist in other capacities. Yours truly, J}- ' Elvis J. Wren Jr., OHST, CSM Manager of Safety LAM 006267 DPMC-18133 Proler International Corp 7501 Wallisville Road Houston, Texas 77001 Unit Demolition at Shell Oil Company Deer Park, Texas G-Areas June 15. 1988 Health and Safety Management, P. 0. Box 693 Nederland. Texas 77627 Inc. Approved By C3P DPMC-18134 LAM 006268 Table of Contents Subject Purpose Summary of Results Conclusions Recommendations Observations Methodologv Append i :< Summary of Data Laboratory Resul ts Sampling Data Sheets Page 1 1 1 3 4 7 DPMC-18135 lam 006269 Proler International Corp . 7501 Wallisville Road Houston, Texas 77001 Unit Oemolit ion at Shell Oil Company Deer Park, Texas 6-200 Area June 15, 1988 Purpose : Document the presence and type of asbestos found in the areas that are to be demolished by Pro!er International Corporation Summary of Results; Analysis of bulk samples collected during the preliminary testing reveals that asbestos is present in the demolition site. There is evidence that some encapsulant was used. There also is some equipment from which the asbestos insulation has not been removed. Asbestos was found in five of the eight random bulk samples that were taken in the G-200 area on June 15, 1988. Asbestos was also found on the paving between the roadway and the D.D . unit. Cone 1 us ions: There is positive evidence of asbestos contamination in the G-200 area. There is insulation adhering to flange nuts, in crevices and on lines. It would be difficult to certify some of this material as hazard free for handling and transportat ion. Page 1 DPMC-18136 LAM 006270 Recommendations: Continue to sample equipment that is suspected of asbestos contamination. Follow prescribed GSHA abatement procedures on equipment that has not had the asbestos insulation removed. Continue to follow OSHA regulations pertaining to asbestos, the burning of lead primed steel and the disposal of contaminated clothing. Observations; The work areas were barricaded, all employees were wearing the proper protective equipment and prescribed work practices were being followed. Methodoloqv: Each sample was analyzed for asbestos as outlined in the analysis report of Chemtex Environmental Laboratory of Port Arthur, Texas. Page DPMC-18137 LAM 006271 Froler International Corp 7501 Wallisville Road Houston, Texas 77001 Scrap Removal at Shell Oil Company Eieer F'ark , Texas G-200 Area June 15, 1988 Summary of Data Bulk Samples Date SamDle# . 6/15/88 040071HSM 6/15/8S 040072HSM 6/15/88 040073HSM 6/15/88 040074HSM 6/15/88 040075HSM 6/15/88 040076HSM 6/15/88 040077HSM 6/15/88 4/28/88 040078HSM 040041HSM Location Paving by roadway S/ D.D. unit G-200 Spool & 2nd. level S/ K--701 G-200 Pipe stantion 0/head W/ K-724 Tvpe Asb Amosite Chrysoti1e G-200 4" 1ine 0/head N/ K-724 G-200 Approx . 12" 1 ine E/W N/ K-724 G-200 16" F'owel 1 gate valve W/ K--701 Chrysoti1e Amosite Chrysoti 1 e G-200 Cont. rm. ceiling patch W/ K-701 G-200 valve N/ E-725 Chrysoti 1 e G-500 sm vessel Amosite Result 1* to 2* 35* to 40* 0* 10% to 15* 3* to 5* 0* 20* to 25* 0* ,-ver> -L U to 30* 1* to 2* LAIW 006272 DPMC-18138 lam 006266 DPMC 18132.1