Document 71JXmGDqbbRVeJVVq32pMaQ6E

1 Jo. M. Ji. A//{Zccacj{ -- &(.oc y faosi .' . T. - S~ y / 7?>***S CC: W T. Dodson L. F Go tz J. W. Bolduc J. E. Sthay W. G Tod d T. H. Barker R. A. Bates B. Thornbrugh L. G. Rodriguez C. G. Hull R. C. Otworth M. R. Morfin L. Jurek S. W. Ellis Alathon Maintenance Foremen October 11, 1984 TO: V) A SCZECH FROM: R J MOCZYGEMBA>00?" ALATHON" ASBESTOS GASKET AND PACKING PROGRAM In response to A. H, Nicholaus* letter entitled "Use of Asbestos Gaskets" dated 6-18-84 (attached), I air proposing a program to phase out asbestos containing gaskets and packing where feasible from "F" and "J" Units. In all cases removal of asbestos packing and gaskets will be on an "as needed" basis. The non-asbestos gaskets and packing types I am proposing are recommended in the Engineering Standards. This program is straight forward in eliminating asbestos containing pipe flange gaskets, equipment gaskets, and valve packing, however phasing out packing used in equipment will require Technical involvement to determine [the best replacement. Pipe Flange Gaskets Mo a tj low pressure process .pipe flange gaskets in "F" and "J" Units are spiral wound gaskets using a metal winding with an asbestos papejr filler. The Flexitallic" Gasket Company has developed a replacement filler called Flexite" Super which is superior to ajsbestos filled spiral wound gaskets (see attach ment). Flexiite* Super can be used in any application where asbestos is used. It is accepted by the Engineering Department and is listedj in the Engineering Standards. DUP 0814515 i | "SAFETY IS MY RESPONSIBILITY' W. A. Sczech 2- w. M. Bounds, of the Design Division is working to add these gaskets to the pipe codes as an alternative to the abestos spiral wound gaskets presently listed. Flexite" Super is comparable in price to asbestos spiral wound gaskets. The gaskets are color coded so the!y are not confused with 100% graphite (Grafoil) or asbestos filjled gaskets. I am proposing setting up Flexite" Super Pipe Flange Gaskets in Stores stock and issuing a COD to use these gaskets in all applications where asbestos spiral wound gaskets are jused. Asbjestos precut sheet gaskets (DuPont Code G-1, Styrene Butadiene Rubber Bonded Compressed White Asbestos) are used in most servicejand some process applications in "F" and "J* Units. Many suppliers have developed non-asbestos sheet gaskets, however none have yeji met the temperature rating, strength and chemical resistance of asbestos. ESD has conducted performance tests on various non-asbestos gaskets on the market. As a result the Engineering Standards have been revised to include acceptable gasket manufacturers. Testing showed only those gaskets manu factured from DuPont Kevlar" aramid fiber pulp to be acceptable. The Engineering Standards list the non-asbestos with a tempera ture rating of 290C compared to 400C for asbestos. Unlike the Flexite" Super for spiral wound applications, these gasket materials can not replace asbestos for all applications. After reviewing all pipe code applications in "F" and "J" Units, I am proposing using the DuPont Code G-80 (Garlock 3200) non-asbestos material for all present G-1 applications with the exception of high pH systejms (pH>1l) such as caustic service and highly basic water systems'. In those applications I am proposing the use of Flexite" Super spiral wound gaskets. The G-80 gasket has 50% higher cost compared to G-1. These gaskets are branded for identification. I am proposing setting up these gaskets in Stores stock land issuing a COD for its use as indicated above. I Thesp gaskets I am proposing to put in Stores will eventually be used by all areas of the plant. The Acids and HMD Divisions are also developing asbestos gasket programs. The asbestos gaskjsts in Stores will not be deleted until all areas have successfully demonstrated the performance of non-asbestos gaskets. A committee chaired by J. L. Chambard has been given the task of working out the details of the transition to non asbestos gaskets. Equipment Gaskets I I amlproposing revising all Stores descriptions for asbestos spiral wound equipment gaskets to specify Flexite" i . Super. Also all Stores descriptions for asbestos precut sheet gaskets for equipment will be changed to S-80 material unless process conditions require other non-asbestos materials. Equip ment involved in these changes will be process vessels, heat "SAFETY IS MY RESPONSIBILITY' D\n `ftosnnr DUP 0814516 w. A. Sczech 3 exchangers, process valves, automatic valves, Daniels check valves, relief valves, pumps, and miscellaneous instrumentation. No equipmentj gasket material change will be made until the pro posed pipe flange non-asbestos gasket materials have been suc cessfully demonstrated for at least six months. Valve Stem picking Nonrasbestos packing material is not new technology as is the case with gasket materials. Most of the valves in "F" and "J" Units are presently packed with non-asbestos material. Grafoil, Teflon yarn lattice braid and Teflon "V" ring packing are the most common. 1 have reviewed all pipe codes in "F" and "J" Units and am proposing a non-asbestos valve packing for all applications where asbestos is presently used. The proposed replacement for all services will be documented with a COD. In general I amjproposing Grafoil" packing for the high temperature and flammable services and 100% Teflon lattice braid for low temperature service and where severe chemical resistance is required. The pipe codes and valve codes will eventually be changed. Equipment Packing In those few cases where asbestos packing is used in equipment (i.e., extruder screws, heat exchanger tube sheets, pumps, etc. ) careful attention should be given to packing selection. Consideration to such items as shaft speed, shaft surface finish, temperature, pressure, lubrication/eooling, packing abrasiveness, etc. makes packing selection unique to each application. For this reason I am proposing technical involve ment and COD'S for each individual case as needed. Miscellaneous This program does not at this time propose any replacepent for ashes tos filled corrugated metal, single or double jacketed metai or french-type metal gaskets. These style gaskets should be ava ilable with other fillers in the near future, Gaskets of thi s type pose no real industrial hygiene concern since they ar^ in most cases totally enveloped with metal. Summary of Program 1. Issue RPO-j-COD for using non-asbestos spiral wound and precut sheet pipe flange gaskets and valve stem packing. Set these items up in Stores. Train mechanics on identification and proper use (Responsibility-Maintenance, Timing 12/84). DUP SAFETY IS MY RESPONSlBILrtX" cpwofi 00 U1 t- Fr*TT*0 I W. A. Sczecn -4 2. After evaluating non-asbestos pipe flange gaskets for at least six months then select suitable non-asbestos equipment gaskets and issue RPO-COD for their use. Change Stores description to show these changes. (Responsibility-Mainte nance, Timing 9/65). 3. Evaluate and issue COD for equipment packing applications as required. (Responsibility-Maintenance/Technical). 4. Specify non-asbestos gaskets and packing for all new equipment ordered. (Responsibility-Maintenance/Technica1) 5. When available begin using non-asbestos filled semi-metallic gaskets. (Responsibility-Maintenance, Timing 12/85). RJM;bw DUP 0814518 "SAFETY IS MV RESPONSIBILITY" .. DV'. RONALD J. MOCZYGEMBA 581 j June 18, 1984 TO: ALL SUPERVISION - LIST "C FROM: A. H. NICKOLAUS BLDG. 3 USE OF ASBESTOS GASKETS Attached for your Information is an article from the February 1984 issue of "Du Pont Environmental Quality Today", lit describes the Engineering Department's program to phase out, insofar as possible, the use of asbestos in gaskets and packings. I The Victoria Plant's policy (I/H Procedure No. 10) is that non-asbestos bearing materials must be substituted wherever feasible for asbestos. Therefore: 1. New installations should specify non-asbestos containing gaskets and packings wherever possible. 2 Non-asbestos gaskets and packings specified as alternatives In the Engineering Standards should be tested in existing Installations. If found suitable, they should replace asbestos gaskets after existing stocks are used up. 3 Priority should be given to replacing those asbestos containing gaskets that are changed most often. AHN/rtg | Attachment I DUP 0814519 "SAFETY IS MY RESPONSIBILITY" FROM: "Du Pont Environmental Quality Today", Feb. 84 ASBESTOS GASKETS ARE GETTING FEWER By now, everyone is aware of the health hazard of breathing jasbestos fibers. On November 4, 1983, OSHA further tightened the regulations on airborne asbestos fibers to reduce the statistical probability of asbestosis and lung cancer. The allowable level was cut from 2 to 1/2 fiber over 0.0002 in. long per cubic centimeter of air. This level approaches the practical limit for detection and will undoubtedly cause companies which supply and process asbestos to get outfof the business. Garlock, the largest U.S. manu facturer of packings and gaskets, discontinued its entire asbestos line at the end of 1982. Jince asbestos fibers in compressed sheet gasketing material are locked in by the rubber binder which makes up about 20% of most sheets, they cause no health hazard to the gasket user with normal handling and use. However, cleanup of flangesjfrom which asbestos gaskets have been removed and handling of used, dried out gaskets will release asbestos fibers. Therefore, from a safety as well as a legal standpoint! many Du Pont Locations ban any asbestoscontaining materials at the site. Aimed primarily at pipe insulation, woven tapes and loose column packings, the ban also includes packing, brake linings, and compressed asbestos gasekts . Design Division's Technical Services Section and the Gasket and Packings Standards Subcommittee have begun a transition program to phase out asbestos gaskets over the next few yelars. They plan to: Jdvise plant personnel of the transition with articles such as this one, and letters where needed . Highlight asbestos-containing gaskets and packings by bold print of their Du Pont codes in Engineering Standards U2A and U1C, and in Specifications SU2A a'nd SU1C. Bpgin listing alternative gaskets along with the G|-l, G-2 and G-40 gaskets in all new P-codes, and revising existing P-codes and specifications. i Remove references to all gaskets containing jsbestos from the Du Pont codes after a period of time . 1' V '< DUP 0814520 [Generally, the stocks of asbestos gaskets on the plants should be used up and not discarded at this time, subject toj plant and department policy. Wherever possible, non-asbestos gaskets should be used by plant maintenance personnel . [The Standards now list four sheet gasket codes for "non-asbesjtos" gaskets which have been specified as substi tutes for :G-1, G-2, and G-40 (compressed asbestos sheet) gaskets. The new non-asbestos codes are S-80, S-81, S-82 and S-83 . The differences are in the rubber used to bond the sheets: jS-80 SBR (Styrene butadiene rubber) e 5-81 NBR (Nitrile butadiene rubber) 3-82 CR (Neoprene) e S-83 EPDM (Ethylene-propylene terpolymer elastomer { Nordel) . For further information, contact C. P. Shaw or W. M. Bounds, ENGG, L-8233 (366-3661). DUP Vf> \ o co cn knuckle DOWN, INC WfexifaMi 6330 WINFREE c * 77087 Asbestos Sp\lral Wound Gaskets vs. Flexite1** Super Comparison Chart Composition Service/Application Recommended Surfai :e Finish Temperature "Sealability Bolting Requirements Residue left on Flangtss Price Asbestos (Chrysotile) hydrated magnesium Silicate with Latex binder As with any Spiral-Wound asbestos gasket 125-250 AARH/RMS Recommended to 1000 F As with any Spiral-Wound gasket As with any Spiral-Wound gasket Yes Similar FlexiU?* Super Chlorite mineral paper with 30% graphite and acrylic binder Better than asbestos Tested at 63-500 AARH/RMS Tested to 1500 F Virtually equal to graphite (see graph on back) Less demanding No Similar DUP 0814522 Conclusion: Flexite Super is superior to all asbestos spiral-wound gaskets. D V1 2006311 ; FLEXITALUC* GASKET COMPANY, INC. BELLMAWR PLANT:! POST OFFICE BOX 848-BELLMAWR, NEW JERSEY 08031 609/931-2500 HOUSTON PLAINT: POST OFFICE BOX 760 DEER PARK, TEXAS 77536 713/479-3491 LOS ANGELES PLANT: 802 SPRUCE LAKE DRIVE-HARBOR CITY CALIFORNIA 90710 213/549-7168 OTHER AFFILIATED COMPANIES: ENGLAND, AUSTRALIA, MEXICO, NEW ZEALAND, SOUTH AFRICA, VENEZUELA Proven Better Sealing Performance Than Asbestos Fillers When tested as a filler material in spiral-wound gaskets. Flexite Super gave better sealing performance than asbestos. Performance figures were ascertained under conditions laid down in a thermal cycling test used in the refining industry. Tests were carried out with 2" NPS Class 300 flanges, using ni trogen gas over a period of 24 hours. Rig was pressurized to 750 psig and left for a minimum of 16 hpurs. Pressure was released and temperature increased to 8601 F over a period of 2 hours and the rig pressurized to 310 psig Pressure and temperature were held for 1 hour. Rig was then'allowed to cool to ambient and pressure and temperature recorded. Temperature was again increased to 860 F and held for 1 hour. Pressure must return to 310 psig for the gasket assembly to successfully meet conditions of the test Temperature The Flexite Super filled gasket assembled between stainless steel flanges was placed in a furnace at a temperature of 1500 F for 4 hours. The gasket was then taken out of the flanges and pressure tested at ambient The gasket was a NW50 N010-40. Available load = 13.03 tons Sealing pressure at available load 1000 PSI To meet the pressure/temperature requirement the gasket must seal a minimum of 40 bar (590 PSI) at the available load. The tested gasket therefore met the requirement easily. Immersion Tests to ASTM F104 Test Condition* H, Increase Standard A*b*tto* Flex**' Supor Oil No. 1 5 hr*, at 150C %. Thickness %. Weight 3.5 52.4 1.7 43.9 Oil No. 3 5 hrs. at 150C Fuel A 5 hrs. at 23' C %. Thickness %. Weight %. Thickness %. Weibht 3.0 51 3 -1.6 43.0 0.6 44.5 -1.0 37.2 Fuel B 5 hrs. at 23"C %. Thickness %, Weight 0.4 54.7 0.9 41.0 Typical Physical Properties Standard Asbestos 'Flexite' Super Density Tensile Strength M0 Tensile Strength CO Compression at 1000 psi Recovery Total Chloride 64 ibs./tt* 520 psi 270 pst 27% 19% 150 ppm 66 lbs./ft.* 460 psi 400 psi 24% 24% 49 ppm ` Ccov" g** *983 p e* tatnc Gasket Cor-canv >nc O C o o oo 4a tcon w