Operating requirements
According to the standards set by the Joint Industries Conference (see Hydraulic Fluids listing under "References"), reservior temperatures should be maintained at less than 130 F (54 4 C)
Tests made during the operation of mining machines with hydraulic systems using petro leum fluids have indicated reservoir tempera tures of 180 F (82 2 C) and higher Such high temperatures may lead to serious wear and leakage, thus increasing the cost of hydraulic operation and reducing its productivity
The temperature of fire-resistant fluids of the emulsion type tends to remain lower during operation than that of the petroleum fluids, m some instances as much as 20 de grees F lower Use of the emulsions, there fore, makes it easier to maintain the reservoir temperature below the recommended maxi mum of 150 F (65 5 C)
The fire resistance of the water-m-oil emulsions depends upon the quenching ac tion of the steam that is generated in the presence of heat Normally, the water con tent must be maintained at around 40 per cent to assure that enough steam will be produced for effective fire resistance
Depending upon the design of the hydrau lic system, high operating temperatures may cause some of the water in an emulsion to evaporate, thereby lowering its resistance to fire Field tests indicate that this loss is not alarming since water in the makeup fluid used will keep the water content above the acceptable safe limits
Nevertheless, to maintain a safe percent age of water, excessive evaporation should be prevented Tests indicate that this is not a difficult problem if the reservoir temperature is kept below 150 F (65 5 C)
Producers of each hydraulic fluid approved by the U S Bureau of Mines are required to furnish a method of determining the water content of the fluid during use Such testing should be done m the manner and at the inter vals recommended by the producer In structions for adding water when such addi tion is necessary are also available from the producer and should be followed
Design of equipment
Most ordinary hazards from hydraulic
fluids can be eliminated through design A factor of safety of at least 8 over normal work ing pressures is recommended for piping and tubing
Equipment such as flexible tubing, which has a definite life under specific operating conditions, should be replaced at predeter mined intervals
To prevent it from vibrating, piping should be securelv fastened to the machine, and all machines should be securely anchored to their bases It should be placed where it will not interfere with the adjustment, repair, or replacement of control valves Piping should not be used to support valves or other equipment where vibration might damage the piping Exposed pipes which might be used as steps should be protected with a suitable cover
Hvdrauhc equipment should be designed to meet the following additional safety re quirements
1 Flexible lines should be restrained or con fined if their failure might constitute a hazard to personnel
2 The operator should not be required to reach past revolving spindles, moving tools, or moving machine or equipment to reach manual controls
3 Hydraulic circuits using accumulators should be interlocked to vent or isolate accumulator fluid pressure when the power is shut off Full information for proper servicing without hazard to personnel should be posted on or near the accumu lator
4 In hydraulic systems containing flammable fluids and using gas at pressures in excess of 250 psi, nitrogen or other inert gas should be used
Another possible source of injury results when air becomes trapped in the hydraulic lines and creates in effect an air "hammer " This effect has been known to rupture lines or connections with such force that persons have been killed by pieces of flying metal Such accidents can be prevented by proper filling and bleeding of hydraulic systems
Heavy-dutv pipe and fittings used to with stand the pressures of hydraulic fluids should