November 10, 1975
OSHA SAMPLING FOR POLYCHLORINATED BIPHENYLS
" P.E. Heisler C.F. Buckley
A.E. Leisy G.L. Johnson^'"''^
Below are the results of recent air sampling fo r PCB's in the air in the Aroclor department.
DATE
LOCATION OF SAMPLE
PERIOD OF TIME SAMPLED
RESULT (mq/M3)
10/9/75
2nd level, at batch chlorinator
3 hrs.
0.022 mg/M3
10/9/75
2nd level at continuous chlorinators
3 hrs.
0.012 mg/M3
10/13/75 10/13/75
2nd level at batch chlorinators 4 hrs. 4 min.
2nd level at continuous chlor inators
4 hrs. 3 min.
0.057 mg/M3 0.058 mg/M3
10/14/75
Ground level at sewer sampler
2 hrs. 55 min.
0.006
10/14/75
Ground level at scrubber dis charge
2 hrs. 53 min.
0.338 mg/M3
Method used;: Absorption in Toluene in two midget impingersfin series), followed by GLC analysis.
DISCUSSION
Positive identification of the type of PCD was not possible. The W.G.K. lab feels confident that primarily lower chlorinated biphenyls were present. The OSHA TLV's for aroclors are as follows:
Aroclor 1242 Aroclor 1254
1 mg/M3 0.5 mg/M3
All samples were below these values. The area around the scrubber will be resampled to determine if it is a high exposure location.
n
R.L. Harness Environmental Control /db
MONS 029249