Document 71G9B8V4mq49XbRYB0mw3qvro

PLAINTIFF'S EXHIBIT INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER PQ BOX 0361. SOUTH CHARLESTON. WV 25303 'uton"H. E. Rucker U,vs,nn 512/2009 Area c'*'vr" h. Avashia, M.D. - 512/23 J. W. Barna - 2009/6 VI. L. Browning - 2009 R. E. Coyner - 2009 C. P. Maxwell - 701/2 B. R. McMakin - 2009 ste Ar8a Sub,f!C' June 12, 1987 EM&TS - HS&EA Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of asbestos exposure monitoring for three days on insulators at the Institute Plant while removing asbestos on a 3-inch steam line and a 4-inch product line at the #1 dock area in an enclosure. The area enclosed was 5.5 x 6.5 x 200 feet or 7150 ftT HEPA exhaust was 120,000 ft^ per hour which is equivalent to 16 air changes per hour. The area enclosed was along the roadway and the dike wall between the #1 and #2 docks. The area was barricaded while enclosure was in place. Seven out of eight personal exposure samples exceeded the 0.2 fiber/cc permissible exposure level standard and the eighth exceeded the 0.1 fiber/cc action level standard. We encourage you to use supplied air respirators as much as possible in the asbestos abatement procedures. Please communicate to your employees the need for the utmost care and precaution while removing asbestos. Employees wore two pair of coveralls, headcovers, boots, gloves and A0 R57-A half-face HEPA cartridge respirators. No street clothes were worn. They showered before lunch and at the end of the workday before leaving plant. UCC 024443 ASBESTOS EXPOSURE MONITORING 2- - June 12, 1987 Please inform S. R. Erskine, B. J. Agosti, P. K. Snodgrass and C. B. Clendenin of their exposure monitoring results as soon as possible. Have them sign and date this report and return to M. A. Patel at Building 701-330. If you have any questions or if we can be of further assistance, please call us on extension 4779 or 3750. WORK BY: APPROVED BY: VES:HJK:MAP:rab 2384P Manhar A; Patel UCC 024444 Oate 5-6-87 5-6-87 5-7-87 5-7-87 5-7-87 5-7-87 5-8-87 >-8-87 ASBESTOS EXPOSURE MONITORING Comp. Ref. W2216 W2217 W2218 Sample Type/ Employee Name Personal/ B. J. Agosti Sample Time 7hr lmin Personal/ P. K. Snodgrass 7hr Omin Personal/ B. J. Agosti 7hr 4min Personal/ S. R. Erskine 6hr 58min Personal/ P. K. Snodgrass 6hr 58min Personal/ C. B. Clendenin 7hr lmin Personal/ C. 8.Clendenin 6hr 46min Personal/ S. R. Erskine 6hr 43min Air Cone. Fibers/cc 0.495 0.547 0.402 0.496 0.231 0.280 0.157 0.503 TWA8 Fibers/cc 0.433 0.478 0.355 0.432 0.201 0.246 0.132 0.422 COMMENTS Stripped, bagged and vacuumed appx. 200 feet of 3 and 4-inch lines in enclosure at #1 Dock area. Stripped, bagged and vacuumed appx. 200 feet of 3 and 4-inch lines in enclosure at #1 Dock area. Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at .i#l Dock area. Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area. Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area. Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area. Stripped, bagged and vacuumed approx. 80 feet of 3 and 4-inch lines in enclosure then cleaned lines at #1 Dock area. Stripped, bagged and vacuumed approx. 80 feet of 3 and 4-inch lines in enclosure then cleaned lines at #1 Dock area. UCC 024445 ASBESTOS EXPOSURE MONITORING (Continued) Comp. Ref. W2216 W2217 W2218 00 1 CO 1 Date i-8-87 Sample Type/ Employee Name AREA AREA Sample Time Air Cone. Fibers/cc twa8 Fibers/cc COMMENTS 6 hr 32min 0.003 0.003 Inlet to HEPA Filtering system for enclosure at #1 Dock area. 6 hr 43min 0.009 0.007 Outlet to HEPA Filtering exhaust for enclosure at #1 Dock area. 389P UCC 024446