June 12, 1987 EM&TS - HS&EA Industrial Hygiene Asbestos Exposure Monitoring
Attached are the results of asbestos exposure monitoring for three days on insulators at the Institute Plant while removing asbestos on a 3-inch steam line and a 4-inch product line at the #1 dock area in an enclosure. The area enclosed was 5.5 x 6.5 x 200 feet or 7150 ftT HEPA exhaust was 120,000 ft^ per hour which is equivalent to 16 air changes per hour. The area enclosed was along the roadway and the dike wall between the #1 and #2 docks. The area was barricaded while enclosure was in place.
Seven out of eight personal exposure samples exceeded the 0.2 fiber/cc permissible exposure level standard and the eighth exceeded the 0.1 fiber/cc action level standard. We encourage you to use supplied air respirators as much as possible in the asbestos abatement procedures. Please communicate to your employees the need for the utmost care and precaution while removing asbestos.
Employees wore two pair of coveralls, headcovers, boots, gloves and A0 R57-A half-face HEPA cartridge respirators. No street clothes were worn. They showered before lunch and at the end of the workday before leaving plant.
UCC 024443
ASBESTOS EXPOSURE MONITORING
2- -
June 12, 1987
Please inform S. R. Erskine, B. J. Agosti, P. K. Snodgrass and C. B. Clendenin of their exposure monitoring results as soon as possible. Have them sign and date this report and return to M. A. Patel at Building 701-330.
If you have any questions or if we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
VES:HJK:MAP:rab 2384P
Manhar A; Patel
UCC 024444
Oate 5-6-87 5-6-87 5-7-87 5-7-87 5-7-87 5-7-87 5-8-87
>-8-87
ASBESTOS EXPOSURE MONITORING
Comp. Ref. W2216 W2217 W2218
Sample Type/ Employee Name
Personal/ B. J. Agosti
Sample Time
7hr lmin
Personal/ P. K. Snodgrass
7hr Omin
Personal/ B. J. Agosti
7hr 4min
Personal/ S. R. Erskine
6hr 58min
Personal/ P. K. Snodgrass
6hr 58min
Personal/ C. B. Clendenin
7hr lmin
Personal/ C. 8.Clendenin
6hr 46min
Personal/ S. R. Erskine
6hr 43min
Air Cone. Fibers/cc
0.495 0.547 0.402 0.496 0.231 0.280 0.157
0.503
TWA8 Fibers/cc
0.433 0.478 0.355
0.432 0.201 0.246 0.132
0.422
COMMENTS
Stripped, bagged and vacuumed appx. 200 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 200 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at .i#l Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed appx. 120 feet of 3 and 4-inch lines in enclosure at #1 Dock area.
Stripped, bagged and vacuumed approx. 80 feet of 3 and 4-inch lines in enclosure then cleaned lines at #1 Dock area.
Stripped, bagged and vacuumed approx. 80 feet of 3 and 4-inch lines in enclosure then cleaned lines at #1 Dock area.
UCC 024445
ASBESTOS EXPOSURE MONITORING (Continued)
Comp. Ref. W2216 W2217 W2218
00
1
CO
1
Date i-8-87
Sample Type/ Employee Name AREA
AREA
Sample Time
Air Cone. Fibers/cc
twa8 Fibers/cc
COMMENTS
6 hr 32min
0.003
0.003
Inlet to HEPA Filtering system for enclosure at #1 Dock area.
6 hr 43min
0.009
0.007
Outlet to HEPA Filtering
exhaust for enclosure at #1 Dock area.
389P
UCC 024446