Document 70Mw2dbgRykwEeRGq4kXvdXeo

'-TTT53 HEATINC VENTILATINC AIR CONDITIONING GUIDE 1942 Table 4. Properties of Carbon Dioxide Sat. Tntr. F Aaa. Press. Lb ter Sq In. Volume liquid Vapor 0 305.5 0.01570 0.29040 2 315.9 0.01579 0.28030 4 326J 0.01588 0.27070 5 332.0 0 01592 0.26610 6 337.4 0.01596 0.26140 8 348.7 0.0160S 0.2S260 10 360.2 0.01614 0.24370 12 371.9 0.01623 0.23540 14 383.9 0.01632 0.22740 16 396.2 0.01642 0.21970 18 408.9 0.01652 0.21210 20 421.8 0.01663 0.20490 22 434.0 0.01673 0.19790 24 448.4 0.01684 0.19120 26 462.2 0.01695 0.18460 28 476.3 0.01707 0.17830 30' 490.8 001719 0.17220 32 505.5 0.01731 0.16630 34 522.6 0.01744 0.16030 36 536.0 0.01759 0.15500 38 551.7 0.01773 0.14960 39 559.7 0.01780 0.14700 40 567.8 0.01787 0.14440 41 576.0 0.01794 0.14185 42 584.3 0.01801 0.13930 44 601.1 0.01817 0.13440 46 618.2 0.01834 0.12970 48 635.7 0.01851 0.12500 SO 653.6 0.01868 0.12050 52 671.9 0.01887 0.11610 54 690.6 0.01906 0.11170 56 709.5 0.01927 0.10750 58 728.8 0.01948 0.10340 60 748.6 0.01970 0.09940 62 769.0 QjQ199S 0.09545 64 789.4 0.02020 0.09180 66 810.3 0.02048 0.08800 68 831.6 0.02079 0.08422 70 853.4 0.02112 0.08040 72 875.8 0.02152 0.07654 74 ' 898.2 0.02192 0.07269 76 921J 0.02242 0.06875 78 944.8 0.02300 0.06473 60 968.7 0.02370 0.06064 82 993.0 0.02456 0.05648 84 86 87.8 1017.7 1043.0 1069.9 0.02553 0.02686 0.03454 0.05223 0.04789 0.03454 Heat Content and Entbopt Taken From -40 F Heat Content Entropy 50 F Superheat 100 F Superheat liquid Vapor liquid Vapor Ht. Ct. Entropy Ht. Ct Entropy 18.8 138.9 0.0418 0.3024 153.7 0.3342 167.5 0.3612 19.8 138.8 0.0440 0.3014 153.7 0.3330 167.6' 0.3600 20.8 138.8 0.0461 0.3005 153.7 0.3318 167.7 0.3588 . 21.3 138.8 0.0472 0.3000 153.7 0.3312 167.7 0.3582 21.8 138.7 0.0483 0.2994 153.7 0.3306 167.8 0.3576 22.9 24.0 25.0 26.1 27.2 138.7 138.7 138.6 138.6 138.5 0.0504 0.0526 0.0548 0.0571 0.0593 0.2982 0.2970 0.2958 0.2946 0.2933 153.7 153.7 153.7 153.7 153.7 0.3293 0.3281 0.3270 0.3259 0.3249 167.9 168JO 168.1 168.2 168.3 0.3563 0.3550 0.3538 0.3526 0.3513 28.3 29.4 30.5 31.7 32.9 138.4 138.3 138.2 138.1 138.0 0.0616 0.0638 0.0662 0.0686 0.0710 0.2921 0.2909 0.2897 0.2885 0.2873 153.7 153.7 153.7 153.7 153.7 0.3238 0.3227 0.3214 0.3202 0.3189 168.5 168.6 168.7 168.8 168.9 0.3501 0.3489 0.3479. 0.3470 0.3460 34.1 35.4 36.7 37.9 39.1 40.4 41.0 41.7 42.3 42.9 137.9 137.8 137.7 137.4 137.2 136.9 136.8 136.7 136.5 136.3 0.0734 0.0758 0.0781 0.0804 0.0828 0.0S51 0.0862 0.0874 0.0887 0.0899 0.2861 0.2849 0.2834 0.2820 0.2805 0.2791 0.2783 0.2776 0.2768 0.2761 153.7 153.7 153.7 153.7 153.7 153.7 153.7 153.7 153.7 153.7 0.3177 0.3164 0.3158 0.31S1 0.3145 0.3138 0.3135 0.3132 0.3127 0.3122 169.0 169.1 169.2 169.3 169.4 0.3451 0.3441 0.3431 0.3421 0.3411 169.5 169.5 169.6 169.6 169.7 *0.3396 0.3391 0.3381 44.3 45.6 47.0 48.4 49.8 51.2 52.6 54.0 55.5 S7.0 136.1 135.7 135.4 135.0 134.5 133.9 133.4 132.7 132.1 13U 0.0924 0.0950 0.0975 0.1000 0.1027 0.1054 0.1081 0.1108 0.1135 0.1164 0.2745 0.2730 0.2714 0.2699 0.2681 0.2663 0.2644 0.2626 0.2608 0.2584 153.7 1S3.7 153.7 153.7 153.7 153.7 153.7 153.7 153.7 153.7 0.3112 0.3101 0.3091 0.3081 0.3069 0.3057 0.3046 0.3034 0.3022 0.3012 269.8 269.9 170.0 170.1 170.2 0.3371 0.3362 ` 0.3352 0.3342 0.3333 ' 170J 170.5 170.6 170.7 170.8 0J324 0.3315 0.3306 0.3297 04289 58.6 60.2 61.9 63.7 65.5 130.6 129.7 128.7 127.5 126.0 0.1194 0.1223 0.1253 0.1282 0.1321 0.2560 0.2535 0.2511' 0.2487 0.2450 153.7 153.7 153.7 153.7 153.7 0J002 0.2991 0.2981 0.2971., 0.2962 170.9 171.0 171.1 171.2 17U 0.3273 0.3265 0.3257 0.3250 67.3 69.4 71.6 73.9 76.4 124.5 122.8 120.9 118.7 116.6 0.1360 0.1398 0.1437 0.1476 0.1578 0.2414 0.2377 0.2341 0.2304 0.2195 153.7 153.7 153.7 IS3.7 153.7 0.2953- 0.2945 0.2936 0.2927 0.2920 171.4 171.5 171.6 171.7 173.8 0.3242 0.3227 0.3220 0.3215 79.4 83.3 97.0 113.9 110.4 97.0 0.1679 0.1781 0.1880 0.2087 0.1978 0.1880 153.7 153.7 153.7 0.2914 0.2907 0.2901 176.0 178.2 180.1 0.3209 0.3204 0.3199 Types of Compressors There are many different types of compressors, using various refrig erants. Each type has its advantages for its particular application, and those generally used for air conditioning are of the following types: 1. Reciprocating compressors (commonly referred to as piston type). 2. Centrifugal compressors. 3. Steam jet. Reciprocating compressors are available in a wide range of sixes and types. Any of a number of refrigerants, including dichlorodifluoromethane 484 CHAPTER 25. REFRIGERATION (F12), methyl chloride, ammonia, carbon dioxide, and sulphur dioxide may be used in reciprocating machines. The first of these is used exten sively in direct expansion systems of comfort air conditioning. Compressors may be classified into two general types, (a) open type, (b) enclosed type. If the driving mechanism is external to the compressor, then the shaft must be brought out through the crankcase and a shaft seal or stuffing box must be used to prevent escape of the refrigerant. This type of compressor is known as an open-type compressor. When trie driving mechanism is located within the crankcase of the compressor in such a way as to avoid the necessity of a shaft seal, the compressor is known as the completely enclosed or hermetically sealed type. Open type compressors may be further classified as belt driven and directly connected. A great number of direct-driven units are now being used which generally operate at higher rotational speeds than the beltdriven type. The present tendency is toward forced lubrication of the bearings of compressors by means of an oil pump driven from the crankshaft, although there are many splash lubricated compressors on the market. The chief advantages of the forced lubricated compressor are that the lubrication system requires less energy for its operation than the splash type, the oil can be easily filtered before it enters the bearings, and less oil is usually required. The' compressor capacity must be selected for and matched to the maximum load for the installation on which it is to be used. Air-con ditioning loads, however, vary over a wide range, and a wide fluctuation in air conditions may result during periods of light load if on-and-off control of full compressor capacity is used- To prevent such undesirable fluctuation, several methods are employed to vary the capacity of reciprocating compressors, such as: 1. By-passing one or more cylinders, of a multi-cylinder compressor, from discharge to suction. 2. Rendering the suction valves of one or more cylinders of a multi-cylinder compressor inoperative. This is usually accomplished by depressing the suction valves. 3. Varying the speed of the compressor, usually by using variable speed or two-speed electric ihotors. 4. Using clearance pockets to control the quantity of refrigerant pumped. 5. Restricting the suction inlet to one or more .of the cylinders of a multi-cylinder compressor either by an automatic modulating valve or by an on and off valve. All of these methods, with the exception of variable speed, result in a slightly lowered overall compressor efficiency when in use, since the mechanical losses remain constant whereas the quantity of refrigerant pumped is lowered. Centrifugal compressors are used with very low pressure refrigerants; usually both evaporator and condenser work below atmospheric pressure. Water arid monofluorotrichloromethane (Fa) are the refrigerants com monly used in centrifugal machines. Compression of the refrigerant is accomplished by means of centrifugal force; therefore, this type of compressor is inherently suitable for large volumes of refrigerant at low pressure differentials. Two or more stages are usually required and high speeds are necessary to obtain good efficiency. 485