316 CHAPTER 28 1962 Guide And Data Book come from the surgical team and as a result of their activities during an operation.1* During an operation most members of the surgical team are in the vicinity of the operating table which creates the un desirable situation of concentrating contamination in this highly sensitive area. Although some studies14'1* have been conducted on the effectiveness of turbulent air movement and displacement air movement systems in the removal of contamination from the operating site, there is insufficient information at present upon which to base a preference for wall- or ceiling-mounted air inlets which produce turbulent air movement or perforated ceiling plenums which produce displacement or piston action. In addition, these studies have indicated that the use of more than one exhaust outlet located on individual walls will improve the removal rate of contami nation.14-1* A minimum of two exhaust outlets located on opposite walls at floor level is recommended. A minimum ventilation rate of 15 room volumes of air per hour is recom mended to provide for dilution of the concentration of contamination and an acceptable rate of removal. Some in vestigators have recommended 20 room volumes of air for this purpose.14 " Operating rooms. Because the operating rooms in the aver age hospital in the United States are not in use more than 8 hr per day, the air-conditioning or ventilating system may be designed to permit the recirculation of the air during the time when the operating rooms ore not in use. Such systems will permit recirculation of the air without costly renovation if as a result of proposed research, it is determined that an acceptable quality of air with recirculation can be maintuned during surgery. Although dramatic results relative to air disinfection of operating rooms by irradiation have been reported,1*-17 this method of disinfection has not been generally applied. The reluctance to use irradiation may be accounted for by such fac tors as special designs required for installation, protective measures necessary for patients and personnel, constant vigilance relative to lamp efficiency, and the required maintenance. The following conditions are recommended for operating, cystoscopic, and fracture rooms: 1. Temperatures of 70 to 76 F. 2. Relative humidity of 50 percent. 3. Ventilation rate of 15 room volumes of air per hour. 4. Recirculation of air not permitted during the time the operating rooms are in use. 5. Positive air pressure of 0.1 in. of water within the operating rooms relative to the pressure of any adjoining rooms. 6. Manometer installed at the surgical supervisor's desk to permit air pressure readings of all rooms. 7. Exhaust air removed from each room at several locations located near the floor. 8. Use of high-efficiency filters on the air supply to the rooms. 9. Entire installation to conform to the requirements of NFPA No. 56, Code for the Use of Flammable Anesthetics, which pertain to explosion hazards. In order to provide maximum safety for the patient and to conform to the above recommendations, a separate fan-coil system will be required to serve the operating rooms. The controls governing the recirculation of the air of the operating rooms should be conveniently located for use by the surgical supervisor. These controls should have a visual signal to indicate whether the air of a room is being recirculated. Recovery rooms. Post operative recovery rooms used in conjunction with the operating rooms should have approxi mately the same temperature and humidity as the operating rooms. As residual anesthesia odor and nausea resulting from anesthesia sometimes create an odor problem in recovery rooms, a ventilation rate of 4 room volumes of air per hotu is recommended. A positive air pressure relative to the sir pressure of adjoining areas should be provided. Anesthesia storage room. The anesthesia storage room, in the surgery, should be located on an outside wall to facilitate gravity ventilation by means of openings located in the wall at floor and ceiling levels. Gravity ventilation at a rate of 2 room volumes of air per hour is required by NFPa No 56, Code for the Use of Flammable Anesthetics. Central sterilizing and supply. Used and contaminated utensils, instruments, and equipment are brought to this unit for cleaning and sterilisation prior to reuse. This unit usually consists of a cleaning area, a sterilizing area, and a storage area where supplies are kept until requisi tioned. Where these areas are in one large room, it is desirable, in so far as possible, to maintain an air flow from the storage and sterilizing areas toward the contaminated clean ing area for exhaust. Temperature and humidity should be within the comfort range, and a ventilation rate of 2 room volumes of air per hour with a balanced air pressure relative to the air pressure of adjoining areas. The following features are important in the central sterilis ing and supply unit: 1. Insulation of sterilizers in these areas will reduce heat load. 2. Sterilizer equipment closets should be amply ventilated to remove excess heat. 3. Air exhaust grilles or hoods, located immediately above sterilizer doors, will assist in voiding excess beat and steam and will protect wail and ceiling finishes. Obstetrical Department The systems designed for the delivery suite should conform in all respects to the requirements for surgical suites. Emergency Department This department, in most instances, will be the most highly contaminated area in the hospital, as a result of the soiled condition of many patients upon arrival and the relatively large numbers of persons accompanying them. The ventila tion, temperature, and humidity requirements of the operat ing rooms in this department will be the same as those of the operating rooms in the surgical suites. Waiting rooms will require a minimum ventilation rate of 4 room volumes of air per hour. Temperatures and humidities of offices and waiting space should be within the comfort range. Service Department Service areas include dietary, housekeeping, mechanical, and employees' facilities. These areas are not usually cooled, .but adequate ventilation is important to provide sanitation and a wholesome environment. Ventilation of these areas cannot be limited to exhaust systems only; provision for supply air must be incorporated in the design. The best designed exhaust system may prove ineffective without an adequate air supply. Experience has shown that reliance on open windows results only in dissatisfaction, particularly during the heating season. The incorporation of air- to ah' heat exchangers in the general ventilation system offers possibilities for economical operation in these areas.1* Dietary facilities. In this area the main kitchen, bakery, dietitian's office, dishwashing room, and dining space will require care in design. Kitchen ventilation should conform to local codes, but in the Hospital Air Conditioning 317 ^jjgence of such codes, a minimum of 20 room volumes of extractors and tumblers where the linen acts as a filter and air per hour is recommended. collects the organisms. It has been reported that many of guch cooking equipment as broilers, ovens, ranges, kettles, these organisms survive the heat of the ironing process and gteamers are generally grouped for efficient utilization. are returned to the hospital on the clean linen.** He area serving this equipment should be vented through To reduce the contamination of the laundry air, it is recom hood to remove heat, odor, and vapors. The ventilation mended that the sorting of linen be done in an enclosed area jste through the hood will vary according to design and separated from the main laundry. This area will require a mounting height,1* but a rate of 100 cfm per sq ft of hood open- ventilation rate of 8 room volumes of air per hour and should _ jg ygry often used with conventional hoods mounted to be maintained at a negative pressure relative to adjoining provide a clearance of 6M ft from the floor. Hoods over areas. ^oofring equipment should be equipped with grease filters to Of the various pieces of laundry equipment, the flatwork remove any grease from the vapors before they enter the duct . ironer produces the greatest amount of heat and vapor. A system. Condensed grease in duct systems is a potential fire usual practice is to install a canopy over the ironer to concen hazard. Safety measures should be incorporated in the design to trate and remove the heat immediately at this point. Most laundry layouts permits a large part of the exhaust to be dis protect the duct system against fires originating over the charged through the canopy, although some exhaust should stove. Such protection can usually be provided by one or also be provided over the washers to remove heat and vapors more of the following methods: an emergency steam line to originating from this equipment. The exhaust from tumblers the throat of the hood at the duct connection for smothering should be carried away by a system independent of the action, COt outlets at the hood perimeter, or fusible link general exhaust system. This exhaust may require lint filters dampers in the duct. in addition to those on the tumbler. All laundry exhaust The hood exhaust fan should be selected to provide the air should be carried to a point above the roof or to an outlet volume required for the maximum recommended resistance of ; where it will not be obnoxious to other areas of the hospital. the filter. These resistances will increase greatly as the filters It should not be in close proximity to fresh air ventilation become fouled. The location of the kitchen air supply inlets intakes. relative to the hood exhaust is important to eliminate the pos- : Fresh air supply is a requisite to good ventilation of this ability of short circuiting between supply and exhaust. Where t area and distribution designed to avoid short circuiting is dietary facilities are located within the hospital structure, ex important. The design may lend itself to the use of air-to-air haust ventilating air should be discharged above the roof. heat exchangers for economy of operation.1* The dietitian's office is often located within the main kitchen | Mechanical facilities. Boiler rooms should be provided with or immediately adjacent to it. It is usually completely en proper ventilation. Exhaust ventilating fans which compete closed to insure privacy and quiet and will therefore require with the boilere and the chimney for an insufficient air supply an air supply inlet and an exhaust outlet in the room. are not uncommon. The air supply to boiler rooms should be The dishwashing room should be enclosed and ventilated at computed on the basis of providing both comfortable working the same rate as the kitchen, to reduce the noise level and to conditions and the air quantities required for maximum confine the contamination and the steam and heat liberated combustion rates of the particular fuel used. Boiler and burner by equipment. Depending upon the size of the area, all or the ratings will establish maximum combustion rates, and the air greatest part of exhaust air may be taken off through the quantities can thus be computed according to the type of fuel. dishwasher hood. Exhaust ductwork should be ooncorrosive Maintenance shops, such as carpentry, machine, electrical, and watertight to handle condensation of steam and should and plumbing shops present no particular ventilation diffi be graded to drip into a convenient drain. culties. Proper ventilation of paint diops and paint storage Dining space. The ventilation of this space should con areas is very important because of fire hazard, and should form to local codes. The reuse of dining space air for ventila conform to all applicable codes. tion and cooling of food preparation areas in the hospital is Employees? facilities. These rooms should be treated to not recommended. Where cafeteria service is provided, serving provide comfort and to conform to local codes. areas and steam tables are usually hooded. The air handling capacities of these hoods will be somewhat less than those REFERENCES required for the cooking area. - Housekeeping facilities. Of these facilities, the soiled linen rooms and laundry only will require special attention. The soiled linen storage room, used as a storage space prior to laundering, is subject to odors from soiled linens and will require ventilation at a rate of not less than 8 room volumes of air per hour. A negative air pressure relative to adjoining areas should be maintained. Laundry ventilation should conform to local codes, but in toe absence of such codes, a minimum of 10 room volumes of Stf per hour is recommended. The design of laundry ventilation systems seldom receives the study necessary to provide proper safeguards against the recoDtamination of linen by airborne organisms during the cleaning process. The activities associated with sorting linen and loading **shera are reported to add heavily to the contamination of toe laundry air. This contaminated air is then drawn through 1 S. M.Farrer and C. M. MacLeod:Staphylococcal infections in & general hospital {The American Journal of Hygiene, July 1960, p. 35). * V. W. Greene et al: Air-handling systems must be planned to reduce the spread of infections {Modem Hospital, August 1960, p. 136). *R. E. O. Williams et al: Hospital Infections (LIoyd-Luke Medical Books Ltd., London, 1950). 4 U. 8. Public Health Service, Communicable Disease Center: Hospital acquired staphylococcal disease {Proceedings, National Conference on the subject, sponsored also by National Academy of Sciences and National Research Council, Atlanta, Ga., September 1958). * R. G. Bond and G. 8. Michaelson: Bacterial Contamination from. Hospital Solid Waste (Progress Report--National Institutes of Health Research Grant E 3019 (Cl), January 1961). * American Public Health Association, Committee on Research: Ihe present status of the control of airborne infections (American Journal of Public Health, January 1947, p. 13). 7 American Public Health Association, Committee on Re search: Progress in the control of airborne infections (American Journal of Public Health, May 1950, p. 82).