Document 6wz95GZ4q9pw3M0w5nweyVXOg
Inspection Report
Mechanical Integrity Test
Osage DNR / Environmental Protection Agency
1201 Elm Street, Suite 500
Dallas TX 75270
Inspector Matthew Allen
MIT Date 07/08/2025
Operator Representative Tallgrass Resources, LLC
Report Sent Operator
Time 09:00
Inject Interval 2900 - 2970
USDW 595
Well Type Dual Completion
Annulus Fluid Type Casing 7
Concentric Pkr Tubing 2.875
Packer Depth 2668
Operator Info
Tallgrass Resources, LLC 1569 E 21st Street, Suite 215 Tulsa, OK 74114 Phone: 918-270-9927
Inventory ID API Well No Lease Name
Well ID
OS1436000
JAC 3
Location NE 29 28N 08E
Type of MIT Ada Pressure Test
Test Reason Routine
Injecting Y
Injection Rate (bpd)
Tubular Lining
Ann Filled (hrs)
MIT Due 07/30/2023
MIT Freq EVERY FIVE YEARS
Ann Press Mont
Time Pre-Test
Tubing Pressure 0
Annulus Pressure 0
Flowback Pressure High
Volume
Initial 09:00
200
200
Mid
Mid 09:15
200
200
Low
Final 09:30
200
200
End Total Volume
ADA Pressure Test - Required Test Pressure
(Fluid Column Ht * Specific Gravity * .433 / N2 Wt Fac =
Required Test Pressure)
Tubing
Annulus
Depth to Top Perf/Open Hole Depth to Fluid Level
Fluid Column Level
2900 197 2703
Specific Gravity of Fluid 1.06
Nitrogen Weight Factor 1.1064
Required Pressure Test 1121.31
Remedial Action Type
Fluid Migration Test Type
Inspection Comments
Inspector Signature
Remedial Action Type Well, OS1436000 had a calculated test pressure of 1121 psi, the well failed to achieve the required test pressure. The tubing was pressured to 200psi and the tubing/annulus equalized to 200psi, which indicated communication between the tubing and annulus. The operator stated they would move a workover rig to the well and attempt to repair the well.
MATTHEW ALLEN Date: 2025.08.12 08:19:06 -05'00' Digitally signed by MATTHEW ALLEN
Supervisor Signature JEANNE ECKHART Date: 2025.08.12 10:40:16 -05'00' Digitally signed by JEANNE ECKHART