Document 6weBMMvroba2xj941QVbOGzL3

Vs. r. rooij'.or -6- June 2^, 1?T3 krM vr i~:i r-r-j-j' 7 ri : C'' "r' crialr fK-l~-'f ~) 1. P:rc PrrJ c hirinr Peve 1 come-t Ko progress vt r made ithis program djrir.r June cue to other commit tme- tr. 7 . fjppo-t to ]):" 5; or r ! .___? err ~reJ * Drum li^irg Verr/Lffectiveners revere 1 1C" er.d 11" rear iruke vehicle? at the Mi chi ran Proving Ground ( J) htvc exr.i: sted tr excessively high rear effectiveness and/or premature lining wee-rout during gencrel dursbiliv. testing. We were ashed to determine the pro file cccse of f&dlurc-. rye impregnar.tr showed tr.e failed drums to h'-ve ther"'l nature creeks in the central rutting path. These cracks ere generated curing coolirr after hi.gn ener.n stops, rapid surface heatirr of the drum ct" cause compress:ve yielding of the surface materiel in the circumferential direction, jpo- teunereture rtal iliretion the su"fece tnen is. in tecs;or and may develop axial crock:, "he i^put power density to cause tnece cracks was calculated and found to exceed any rcneculed brake input or the Pomeo test circuit. However, some driver: were believed to apply the brakes at 9C. Kri in a portion of the test circuit where a closed throttle coast to 60 KPP is specified. This would produce drum stresses which theoretically should crack the drum surface. Dynamometer tests were performed which confirmed that the problem would not result during the scheduled K?G sequence. Five stops from 90 MFH at 15 fp?? did crack the drums. Once cracked, the drum brake effectiveness increases which in turn produces excessive temperatures, greater work input, and excessive lining wear. J-ersonnel: Anderson, Johnson 8003 0293 PRODUCED BY FORD SCF-FORD-1086 I'. Coir.pl or i - une ?9, 1975 **. Vendor Visitations Ivo brake lining sources, Tiiokol and i-endix (Troy, Ji.1.), vere visited to confirm cornclia*ce with our produc:ior trC C. requirements. The most recent shipment of osv-ertos ot Thioxol appears to be high In magnetite and other impurities. A sample was taken for our examination. Cince ester1 or is the mf.^.or ''natural product" used in brake lirir.es end since all our selector comes from the same area of ,'enads, a chance of rev material quality could heve scriour consequences for ell cf our friction mr-cerielr. 1-itiol 'pprovel was given lendix to use the l-.'' Syr ten. 7 automatic data reduction me- ioc of PGC data reduction, personnel: Johnson Weiritreut (Then.:cel Engineering Department) ?. Overseer crake lini-q S. **. At the request of Oversees Engineering, we ere assisting lord of Argentine rr. updating their quality cortrol cepabilities ar.d heve performed tertr of tneir materials to provide a reference. Diagnostics vere performed to dctern.i,`e the cause of a rotor wear problem. Their ?AFT machine valve body was received for inspection, found to be defective, end repaired. Personnel: Anderson Weintraub (Chemical Engineering Department) Th___Automrtic Transmission Diagnostics failed friction materials and used ATF from a Labeco dynamometer test (used for emissions certification testing) were submitted for testing to establish the ceuse of failure. The use of the automated dynamometer tests for 50,000 mile certification testing appears to heve precipitated more frequent transmission failures in which the friction materials lose capacity. The Labeco test runs ' ^ * * ^4* 8003 0294 PRODUCED BY FORD ,, j: *C- June ?9, I97j continuously and has leer cooling than ic ottair.ed in vehicle use. Thus the transmission temperatures are both higher and more constant. Diagnostics are in progress. Personnel: Anderson Weintraub (Chemical I'nrineering, Department) 1_.___Antonetic Transmission 'Unnk Investigation Work continuer on the trensmisrior "clunk" problem. Tests of an instra-cr.ted T-6 uransmissior are in progress to establish the causative factors and to determine the sound producing elements. Personnel: Anderson, Johnson r's ;j:p m Werr (v-lll ?) ]. '"art Iron Wear Program Ivo veer tests vere conducted on the Hohman vear machine with hardens: le iro-. 1^ the first test, the load and speed were equivalent to normal valve sprir.r load end erpi'-'e idling speed, rerpeetively, as seen ry t.ne camshaft and tappet. Ihe test ran for only eight revolutions before the machine stalled due to hign frictional forces, both wear test surfaces were severely railed. Jor the secoiit test, the load end speed were reduced by one order of magnitude and the specimens completed two hours of testing. Doth weer test surfaces were coated with red iron oxide. The friction coefficient stabilized at about 1.0, These unlubricated results will be compared to the results of future tests on lubricated specimens simulating camshafts and tappets. A Honeywell visicorder, to be used with the Hohman machine, is being installed. This has caused a temporary delay in the wear test program. The installation is nearly completed end testing should resume by the end of June. Personnel: Hall, Janotik 8003 0295 r PRODUCED BY FORD