Document 6wDz5KmK8qp31oj8RpqdJ2Mk3
ROCKBESTOS
WIRE & CABLE
ASBESTOS Insulated
Wire &, Cable
ROCKBESTOS WIRE & CABLE CO. !
DIVISION OF CEBRO CORPORATION
NEW HAVEN 4 - CONNECTION
RBB 00470
A. FIU No. 31-C-472 a lio N o. J 1 -C -4 7 *
<
ROCKBESTOS WIRE & CABLE CO.
Division of Cerro Corporation Main Office and Works
NICOU AND CANNER STS., NEW HAVEN 4, CONN., U. S. A.
o
O
i. I. A. FIU No. 31-C -672 a lio No. 31-C-67R
5M 10-62
PRINTED IN U.S.A.
RBB 00471
ROCKBESTOS is the name -for a wide line of wires, cables and cords, including more than 125 different standard constructions, which have been designed and developed to give long and depend able service under severe operating conditions. Early in 1918 a small group of Rockbestos Elec trical Engineers and Chemists perfected a method of applying asbestos to wires and cables as a heat resisting electrical insulation. This first step result ed in the production of wire that industry and elec trical engineers had been looking for. Here was an insulated conductor resistant to high tempera tures, aging, corrosive fumes, grease, oil and flame. Success from the start--and just the beginning for this company which was later to distinguish itself to be the only company in industry devoted ex clusively to the manufacture of permanently insu lated wires and cables. Rockbestos grew along with the then rapidly growing electrical industry, solv ing its electrical insulation problems as they became
apparent with this unique mineral, ASBESTOS. Other materials are often combined with asbes tos, i.e. Varnished cambric, Synthetics, DuPont "Teflon'' Tettafiuoroethylene resin, cotton, rayon, nylon and glass, to provide special characteristics. Two broad lines of permanently insulated wires, cables and cords--Rockbestos A.V.C. asbestos-var nished cambric insulated (N.E.C. Types AVA and AVB) and Rockbestos ALL-Asbestos (N-E.C. Types A, AA, AI, AIA and AF)--have been de veloped for innumerable industrial applications. Rockbestos engineering and research are constantly abreast of electrical problems in both science and industry, providing answers through the develop ment of trouble-free, ageless electrical insulations designed for each specific application. May we offer you our research facilities for the development of special wires designed to meet any unusual re quirements.
RBB 00472
f
This is the Rockbestos Handbook and Catalog No. 10-H, which illustrates and describes wires and cables insulated with Asbestos Varnished Cambric> and All Asbestos insula tions for use where wiring in electrical products or in the power, control and lighting circuits of industry is exposed to heat, corrosive fumes, grease, oil or fire hazard.
Also contained in this catalog are Rockbestos special con structions developed for special and specific applications.
All data subject to change without notice.
ROCKBESTOS WIRE & CABLE CO.
DIVISION Of CERRO CORPORATION
MAIN OFFICE AND FACTORY: Nicoll and Canner Streels, New Haven, Conn.
s
RBB 00473
Table
A A-300
B BH BS
Page
600 Volt Rheostat Wire............................................................. 300 Volt Rheostat Wire, High Temperature........................ 600 Volt Switchboard Wire (Solid) ....................................... 600 Volt Switchboard Hinge Cable....................................... 600 Volt Switchboard Wire (Stranded)..................................
20 24 17 18 17
C CL
E EL EMA
600 Volt Lighting Wire (Solid) ............................................. 600 Volt Lighting Wire--Lead Sheathed.............................. 600 Volt Power Cable--Single Conductor.............................. 600 Volt Power Cable---Lead Sheath, Single Conductor...... 1000 Volt Lead Wire...................................................................
12 14
9 15 27
FS FSB
H
HL L
300 Volt Fixture Wire............................................................... 300 Volt Fixture Wire (Braided) ....................................... 5000 Volt Power Cable, Single Conductor...................
5000 Volt Power Cable, Lead Sheath, Single Conductor 600 Volt Motor Lead and Apparatus Cable..........................
25 25
9
15 13
LH-LHV LHG-LHT
MD ML
Industrial Heating Cable....................
..
Special Industrial Heating Cable .......... Heating Cable Kits and Thermostat
.
...
600 Volt Control Cable, (AWG No. 12-19/25) .................. 600 Volt Mining Cable................................................................
29 30 31
11 26
MT R
R-300
RF RF-300
600 VoltControl Cable (AWG No. 9-19/22)...................... 600 VoltPower and Rheostat Cable ....................................... 300 VoltRheostat Wire, (Stranded) .......................................
600 VoltApparatus Cable, Flexible........................................ 300 Volt Rheostat Wire (Flexible Stranded) ........................
11 21 24
22 24
TC-TCC-TCS W
XB-XBS-XBH
ZM
Thermostat Control Wire............................................................ 300 Volt Apparatus Cable, Extra Flexible.............................. 600 Volt Switchboard Wttes, Type TA..................................
1000 Volt Hookup Wire.............................................................
28 23 19
27
RBB 00474
3
ASBESTOS OUR BASIC
RAW MATERIAL
In entering upon a description of Rockbestos wires and cables, a brief outline of the characteristics of asbestos, the chief material used in their insulation, is a logical beginning. Asbestos is a mineral, consequently inorganic in its na ture, and in this principal feature different from all other types of material in use for insulating wires and cables. Asbestos fibres are solid, that is to say they have no cap illary opening through their center like cotton, wool or other organic fibres. Because of this fact, there is no ten dency for individual asbestos fibres to act as capillaries if their ends are exposed, and it only becomes necessary to fill the voids of interstices between the fibres to pro duce a relatively impervious layer. Asbestos has demonstrated its ability to withstand time without the deterioration that occurs in other forms of electrical insulating materials such as rubber and the gen eral class of organic fibres. Furthermore, it will not rot or carbonize under any conditions. It may be faicly stated indeed that asbestos is ageless, and time, as every engi neer well knows, is a much more exacting test of a material than almost any laboratory accelerated life test which can be made. During the centuries since the as bestos was formed, it has been exposed to high earth temperatures and, as earth cooled, to moisture and the wide variety of earth acids and alkalis, all with no apparent change in any of its properties. We have investigated the world's sources of asbestos to find and secure the softest, silkiest, purest, long fibred asbestos... and we find it in certain deposits of Chrysotile (Serpentine Group)--the aristocrat of the asbestos family.
Chrysotile is a hydrated magnesium silicate which occurs in crystalline form in veins or striations in the mother rock and is widely distributed. Each crystal is a "fibre", square in cross section, haviog a diameter of about 1/500, 000 inch and a length equal to the width of the vein. There are a number of sources of Chrysotile fibre, the principal ones being Rhodesia, Canada, Russia, Arizona and Australia. The largest deposits are in Rhodesia and Canada. Asbestos retains its strength and fibrous form under all conditions except extremely high temperatures. Chryso tile asbestos in crude (unopened form) begins to lose some of its water crystallization at about 450C and is almost completely dehydrated at 850C. It fuses at about 1500C. When applied to wires or cables in felted form, its low heat conductivity enables it to withstand melting the copper conductor by passage of high currents without material loss of its mechanical strength. Tests of fabrics woven of Chrysotile asbestos show that after three hours at 500C they still have their original tensile strength. Asbestos, after it is mined, is broken up, fiberized and cleaned. It is then combed and carded into soft, fluffy roving. In this form it is applied to the conductor, impregnated with neutral insulating compounds, and compressed into the felted wall which is Rockbestos insulation that is not only fireproof but practically impervious to the destruc tion normally caused by heat and moisture, oil, grease, corrosive fumes or age. What a material to use where endurance and resistance to deterioration are so important!
Hard as a rock in the vein, asbestos is soft as silk when fiberized. Each silky fiber is a crystal !/500,000th of an inch in diameter.
A m'tUion-year-old handful! This asbestos has been completely fiberized and prepared and is now ready to be carded into roving.
RBB 00475
WHY ROCKBESTOS A.V.C. WAS DEVELOPED
Since die early days of electrified industry, there has been a definite need for an electrical conductor insulation which would operate dependably in elevated ambient temperatures. High ambient temperatures were a prob lem then as they are today, and the performance of or* dinary wires and cables at that time was restricted by the very nature of the materials used. Rubber, for instance, while known to be high in moisture resistance, was af fected by high temperatures which caused it to become dry and porous limiting its length of effective service. The life of straight varnished cambric insulations too was seriously affected by high ambient temperatureswhich tended to cause deterioration of the tapes. Early asbestos insulations proved unsatisfactory because they consisted only of a series of asbestos braids filled with paint or other compound.
Recognizing that high temperatures and moisture were the major threats to the life of insulations, Rodcbestos Engineers designed and developed their A.V.C construc tion. This A.V.C. construction used as a basis dense felt ed walls of thoroughly impregnated asbestos to form a continuous insulation which would permanently resist heat, flame and moisture. High dielectric varnished cam bric tapes were added as an insert between the felted as bestos to give added dielectric strength and moisture resistance. In this combination the felted asbestos also provided protection for the Varnished Cambric tapes against mechanical damage, deterioration from oxida tion and prevents the formation of a continuous carbon path from conductor to ground. This basic construction was covered overall with either impregnated asbestos or flameproof cotton braids. This new Rodcbestos A.V.C construction was designed primarily to safely and depen dably carry electrical loads in high ambient locations and to withstand additional operating hazards such as attacks of chemicals, oils, grease and fumes. Here was an insu lation designed to give a long life of dependable oper ation under severest conditions.
Since the introduction of Rockbestos A.V.C. wires and cables in 1927, many millions of feet have been installed throughout the world under normal and abnormal oper ating conditions. These installations have covered a wide range of high temperatures and moisture conditions in practically every known industry. Rockbestos Field Engi neers have constantly checked many of these installations in various industries since 1927 to check field conditions against long time tests run by our Research Laboratory
to confirm the ability of Rockbestos A.V.C. to meet un usual service conditions. Because of their successful oper ation, these asbestos-varnished cambric wires and cables were included in the National Electrical Code in the 1937 Edition and designated as N.E.C Types AVA, AVL and AVB. The trade name "A.V.C" as registered by Rockbestos and used commercially is synonymous with National Electrical Code Types AVA, AVL and AVB. That is, A.V.C finished with asbestos braid is Type AVA, with lead sheath is Type AVL and with cotton btaid is Type AVB.
THE HM STORY
Maximum current earning capacities of insulated con ductors are determined within practical limits by the mairtmiifn temperature the insulation will stand without undue deterioration.
The Code in rating this original Rodcbestos A.V.C. con struction permitted it a higher temperature limit than ordinary insulations because its impregnated felted as bestos walls safely resisted deterioration under high am bients and the heat from current loads. Chapter 10, Ta bles I and II, under "Allowable Current-Carrying Capadries at 30C" list Rockbestos A.V.C Type AVA con struction with greater current carrying capadty size for size than for cables with ordinary insulations. The prac tical advantages of Rodcbestos A.V.C. begin here. As ambient temperatures increase and correction factors are applied, A.Y.C is de-rated far less than ordinary con structions, all because of its insulation.
At 70C, for instance, other types of Insulations are de rated as much as 65% while Kockbestos A.V.C. is de rated only 29%. At ambient temperatures in excess of 85C a limiting point for other types of insulations, Rockbestos A.V.C. rated at 110C continues to provide permanent protection for electrical circuits.
Plant layouts and expansion programs ate given greater flexibility by installing Rodcbestos A.V.C. because not only does it provide greater current carrying capadty for intermittent demands and future load growth in existing dreuits, but the installation of heat generating equipment is not restricted by its nearness to vital electrical circuits. The fact that you can use a smaller sized cable to carry a given load can start a whole series of cumulative sav ings.
Smaller cable means smaller conduit and fittings. Easier, quicker installations, plus years of dependable perfor mance, prove Rodcbestos Hi-I A.V.C.... Your Best Buy.
ROCKBESTOS A.V.C. CONSTRUCTION
(1) First impregnated felted asbestos wall. (2) Varnished cambric tapes. (3) Second impregnated felted asbestos wall.
(4) impregnated asbestos braid for Type AVA cables. (Flameproof cotton braid for Type AVB cables.) (Lead Sheath for Type AVL cables.)
RBB 00476
TYPICAL APPLICATIONS FOR POWE WHERE SUBJECTED T<
6
POWER CIRCUITS UP TO 5000 VOLT SBtVICE Standard Rockbestos A.V.C. (Code Type AVA) Power Cables are available in voltage ratings of 600 to 5000 volts. They are designed to protea circuits that must operate without failure un der continuous exposure to high temperatures and other severe operating conditions. Copper shielding can be provided where re quired. They are available in single or multi-conductor construc tions with either lead sheaths or asbestos braids. Interlocking armor can be furnished to special order. Rockbestos A.V.C. (Code Type AVA) Power Cable constructions are approved by the Na tional Electrical Code, listed by the Underwriters* Laboratories and conform-'to NEMA standards.
CONDUIT WIRING AROUND FURNACES, OVENS, SOAKING PITS, BOILERS, ETC.
Rockbestos A.V.C Power Cables and Lighting Wires can be run in conduit as they are built to withstand the normal moisture con ditions resulting from condensation caused by heating and cooling cycles. In cases where power and lighting circuits are exposed to high temperatures in combination with excessive condensation or complete submersion, use lead sheathed Code Type AVL.
LIGHTING AND POWBt CIRCUITS Rockbestos Hi-I A.V.C (Code Type AVA) Lighting and Power Cables are high temperature cables. This A.V.C construction-- rwo layers of impregnated felted asbestos encasing the varnished cambric--permits continuous operation at copper temperatures of 250F (110C), thus making Hi-I cables ideal for high ambient "Hot Spot** locations or, in normal ambient installations, per mitting the use of smaller cables with consequent savings of cop per, conduit, fittings and man-hours of labor as compared with cables having ordinary insulation.
6 RBB 00477
LIGHTING and CONTROL CIRCUITS HIGH TEMPERATURES
**
RHEOSTAT AND APPARATUS WIRING Rodcbestos All-Ast>cstos Rheostat Wires and Cables were design ed primarily for open wiring. Operating temperatures of 125C for 600 volt ratings and 200C for 300 volt applications can be safely met as constant elevated temperatures will not cause the compounds to fall away or flake off even through repeated heat ing and cooling cycles. It is especially recommended for grid jumper connections from grids to faceplates, ovens and element leads on well type anneal ing furnaces and open wiring exposed to extremely high temper atures, corrosive fumes, grease, oil ot fire hazard.
SWITCHBOARDS AND PANEL BOARDS
Millions of feet of Rodcbestos fireproof A.V.C (N.E.C. Type AVB) Switchboard Wire have been used by switchboard manu facturers, power stations and industrial plants since we originated and patented the A.V.C. type. Fine appearance is assured complet ed boards because it can be bent at right angles without cracking the braid. Rockbestos A.V.C. Switchboard Wires have a maximum operating temperature of 90C (194F) and are listed by the Underwriters' Laboratories. They comply with the NEMA Small Wiring for Switchboards Standard and are approved by Factory Mutual Lab oratories, switchboard manufacturers and power companies. See Page 42 for Rodcbestos synthetic and asbestos insulated switch board wires, N.E.C. Type TA constructions.
MOTOR LEADS ^Mill motors and other heavy duty stationary and traction types us Rodcbestos A.V.C. Motor Lead and Apparatus Cable for pro tection against conductor-heating overloads and high ambien
temperatures. This cable retains its flexibility indefinitely becausi it won't dry out with heat or age, won't rot or bloom from con tact with oil or grease and won't burn or carry flame. These per forcnance-protecting characteristics make it ideal for motor wiring in steel mills, generating stations, all types of coal mining equip ment, industrial plants--and numerous electrical apparatus app iications.
RBB 00478
7
POWER CABLE
NEC TYPE AVA--ROCKBESTOS A.V.C. 600 TO 5,000 VOLT RATINGS
SINGLE CONDUCTOR--STRANDED
APPLICATIONS
Rockbestos A.V.C. (N.E.C Type AVA) Power Cables are designed to operate at voltages from 600 to 5000 volts. They are especially recommended for circuits ex posed to severe operating conditions in power stations, steel mills, refineries, tanneries, smelters, etc. and for apparatus which operates under high ambient temper atures.
On the higher voltage rated cables, suitable copper shielding tapes may be specified to eliminate effects of corona on the primary dielectric--the varnished cam bric. Voltage rating of all Rockbestos Hi-I A.V.C. Power Cables is maximum phase to phase voltage. This applies to either grounded or ungrounded systems.
The cables listed in this section have ample moisture resistance for average conditions, but if there is a pos sibility that circuits may be submerged in water for long periods, use lead sheathed constructions in the AVL section of this catalog. The wires and cables in this section are approved National Electrical Code Types, listed by the Underwriters' and fulfill the re quirements of NEMA for Asbestos-Varnished Cambric wires and cables.
SPECIFICATIONS
Construction
1. Stranded plain copper conductor 2. Felted asbestos 3. Varnished cambric 4. Felted asbestos 5. Asbestos braid
Maximum conductor operating temperatures follows:
600 Volt 1000 Volt 2000 Volt 3000 Volt 4000 Volt 5000 Volt
110C 110C 109C 106C 103C 100C
(230F) (230F) (228F) (222F) (217F) (212F)
Standard finish colors: Black and white. Authorized Stock item: (600 volt-Table E only) Black.
Flexible standings may be specified on all construc tions up to 5000 volts.
AH constructions listed can be covered with lead sheath, armor, or lead sheath and armor, if desired. Interlock ing armor can be furnished to special order.
RBB 00479
ROCKBESTOS A.V.C.
SINGLE CONDUCTOR POWER CABLE
TABLE E, 600 VOLTS
MAX. OPERATING TEMP. I10C (230F)
TABLE H, 5000 VOLTS
MAX. OPERATING TEMP. 100C (212#F)
Size
Stranding
#
TABLE E
I8AWG 16
14 12
10 8 6 5
4
3 2 1
0 00 000 0000
250.000 CM 900.000 330.000 400.000
450.000 300.000 550.000 600.000
630.000 700.000 750.000 800.000
850.000 900.000 950.000 1.000.000
1.250.000 1.300.000 1.750.000 2.000.000
7/.0152 7/.0192 7/.0242 7/.O305
7/.0385 7/.0486 7/.0612 7/.0668
7/.0772 7/.0867 7/.0974 19/.0664
19/.0745 19/.0837 19/.0940 19/.1055
37/.0822 37/.0900 37/.0973 37/.1040
37/.1103 37/.1162 61/.0950 61/.0992
61/.1032 61/.1071 61/.1109 61/.1145
61/.1180 61/.1215 61/.1248 61/.1280
91/.1172 91/.1284 127/.1174 127/.1255
TABLE H
Bere Diem. laches
.046 .058 .073 .092
.116 .146 .184 .206
.232 .260 .292 .332
.373 .419 .470 .328
.575 .630 .681 .728
.772 .813 .855 .893
.929 .964 .998 1.031
1.062 1.093 1.123 1.152
1.289 1.412 1.526 1.632
Nomine! Thickness -- Mils
1st Felted Well
VC Insert
2nd Felted Asbestos
Well
Breid
Nomine! Finished Diemeter
Iwrlwi
600 VOLTS
10 30 13 40 .235
10 30 15 40 .250
10
30
15 40
.265
10
30
15 40
.283
10
30
15 40
.310
10 30 15 45 .350
15
30
20 45
.405
15
30
20 45
.430
15
30
20 45
.455
15
30
20 43
.480
15 30 20 45 .515
20
30
30 45
.565
20
30
30 45
.625
20
30
30 43
.670
20 30 30 43 .720
20 30 30 45 .780
25
40
40 45
.875
25 40 40 45 .930
23 40 40 43 .983
23 40 40 45 1.030
25 40 40 45 1.075 25 40 40 45 1.115 30 40 40 45 1.165 30 40 40 45 1.205
30 40 40 45 1.240 30 40 40 45 1.275 30 40 40 45 1.310 30 40 40 45 1.345
30 40 40 45 1.375 30 40 40 45 1.405 30 40 40 45 1.435 30 40 40 45 1.465
30 50 50 45 1.640 30 50 50 45 1.765 30 50 50 45 1.880 30 50 50 45 1.985
5000 VOLTS
Approx.
Net Wgt in Lbs.
per 1000'
30 35 43 55
70 95 140 165
200 240 285 370
430 H5 665 815
985 1155 1325 1490
1660 1825 2005 2175
2340 2505 2675 2835
3000 3165 3330 3490
4375 5155 6030 6760
tStxnderd Shipping
Length Feet
Approx. Shipping Weight per 1000'
TYPE AVA
500' C 500' C 500' C 300'C
300'C 500'C 500'R 300'R
500'R 300' R 300'R 300'R
500'R 300'R 500' R 500' R
500'R 500' R 500'R 300'R
500' R 500'R 500' R 500'R
500'R 500' R 500'R 500'R
500' R 500'R 500' R 500' R
300'R 500'R 500'R 500' R
37 43 56 68
87 118 175 206
250 300 356 462
562 681 831" 1018
1231 1443 1636 1862
2075 2281 2506 2718
292 5
3131 3343 3543
3750 3956 4162 4362
5468 6443 7537 8450
TYPE AVA
I0AWG 8 6 5
4 3 2 1
0 00 000 0000
250.000 CM 300.000 350.000 400.000 450.000
500.000 550.000 600.000 650.000 700.000
750.000 800.000 830.000 900.000 950.000
1.000.000
7/.0385 7/.0486 7/.06I2 7/.0688
7/.0772 7/.0867 7/.0974 19/.0664
19/.0745 19/.0837 19/.0940 19/.1035
37/0822 37/.0900 37/.0973 37/.1040 37/.1103
37/.1162 61/.0950 61/.0992 61/.1032 61/.1Q71
61/.U09 61/.1145 61/.1180 61/.1215 61/.1248
61/.1280
.116 .146 .184 .206
.232 .260 .292 .332
.373 .419 .470 .528
.575 .630 .681 .728 .772
.813 .855 .893 .929 .964
.998 1.031 1.062 1.093 1.123
1.152
15 15 15 15
15 15 15 20
20 20 20 20
25 25 25 25 25
25 30 30 30 30
30 30 30 30 30
30
120 25 45 .530 150 500'R
120 25 45 .560 190 500'R
120 25 45 .595 230 500'R
120
25
45
.620
260 500' R
120 25 45 .645 295 500'R 120 25 45 .670 345 500' R 120 25 45 .705 395 500'R 120 30 45 .765 490 500' R
120 30 45 .805 555 500' R
120
30
45
.850
670 500'R
120 30 45 .900 795 500' R
120
30
45
.960
955 500' R
120 40 45 1.035 1120 500'R 120 40 45 1.090 1300 120 40 45 1.145 1480 120 40 45 1.190 1660 120 40 45 1.235 1825 500'R
120
40
45
1.275
2010
500' R
120
40
45 1.325 2185
500' R
120 40 45 1.365 2360 500' R
120
40
45
1.400
2530
500'R
120
40
45
1.435
2700
500' R
120
40
45
1.470
2870
500' R
120 40 45 1.505 3040 500' R
120
40
45
1.535
3210
500' R
120
40
45
1.565
3360
500' R
120
40
45
1.595
3530
500' R
120 40 45 1.625 3720 500' R
Finished diameters gireo shore ste trerafe. A tolerance of plus or minus $% if necessary due to rariation in process of manufacture. R--Reels
187 237 287 325
366 431 493 612
693 837 993 1193
1400 1625 1850 2075 2281
2512 2731 2950 3162 3375
3587 3800 4012 4200 4412
4650
RBB 00480
9
ROCKBESTOS A.V.C.
600 VOLT CONTROL CABLE
TYPE AVA--ROCKBESTOS A.V.C.
MAXIMUM OPERATING TEMPERATURE: 110C <230F)
ft
\i
f ''"''"''fi?,',,*}-...vW '
7
4
*
ai
APPLICATIONS
Modified in design from our Soaking Pit Cable for covet door control wiring which must withstand the intense heat of red-hot ingots whea adjacent covers are off, this A. V. C control able has proven resistance to high temperatures. This cable finds its use in steel mills, power stations, boiler rooms, automotive, ceramic and glass plants or other indus tries in which control and signal circuits or control appara tus are exposed to heat oc fire hazard. It is especially recom mended for use in circuits and apparatus in metal making mills, boiler rooms, and power plants as it is highly resistant
Conductors The standard stranding; furnished on these Rockbestos A.V.C. Control Cables is 19/22 (No. 9 A.W.G.) and 19/25 (No. 12 A.W.G.) but any desired stranding can be furnished to order and cabled into any required number of conductors.
Insulation The insulation of the individual conductors is the same type as that on the power cables described on the previous pages with the exception of the outer braid which is a color coded cotton braid to obtain circuit identification. When furnished for single conductor use asbestos braid replaces cotton braid. Impregnated felted asbestos walls seal the varnished cambric from heat, flame and oxidation. Moistureproof tape is wrapped over the cabled conductors and the
to heat, corrosive fumes, oil, grease and flame and has ample moisture resistance for installation either open or in conduit. Under exposure to flame this cable will maintain vital control and alarm system circuits for longer periods than other types of insulated cables.
SPECIFICATIONS
1. Tinned copper conductor 5. Color coded cotton btaids
2. Felted asbestos
6. Cable tape
3. Varnished cambric
7. Asbestos braid
............4. Feltedasbestos
This cable is NEMA TYPE AVA with a maximum operat ing temperature of 110C (230F).
outer covering of tough, braided asbestos yarn is finished with heat, flame and moisture resisting compounds.
Coding The individual wires ate braided in colors accotding to the NEMA standard color code for multi-conductor cable, which is reproduced below. Special color combinations can be furnished to specification.
Lead or Armor Covering These cables may be made up wirh either lead sheath, armor, oc lead sheath and armor coveting. Synthetic sheathing is optional also where temperatures permit.
Finish The standard finish of the outer braided asbestos jacket is a black, flame, heat and moisture resisting compound.
NEMA STANDARD COLOR CODE FOR MULTI-CONDUCTOR CONTROL CABLE
Conductors
1 2
3 4 5 6
Base Color
Black White
Red Green Orange Blue
Conductors
7 8 9 10 11 12 13
Base Color
White Red
Green Orange
Blue Black Red
Tracer
Black Black Black Black Black White White
Conductors
14 15 16 n 18 19
Base Color
Green Blue Black White Orange Blue
Tracer
White White
Red Red Red Red
0.
0
10
RBB 00481
. 600 VOLT
CONTROL CABLE
TYPE AVA--ROCKBESTOS A.V.C
Nominal sizes--9 and 12 AWG
1-19 Conductors
(See Opposite Page for General Information)
Standard conductor sizes are AWG No. 9-19/22 and No.
12-19/25 tinned copper, insulated with a 10 mil wail of felted and impregnated asbestos, 30 mil wall varnished cam bric insert, another 15 mil wail of felted asbestos and a cotton braid colored according to die NEMA Control Cable Color Code for Multi-Conductor Cables, listed on the oppo site page. The individual conductors are then cabled with jute fillers where necessary, a layer of cable tape is applied and finally an asbestos braid finished with black, flame, heat and moisture resisting compound.
The standard make-up on two conductor construction is to cable the conductors with fillers to make round, but it can also be furnished in parallel construction. Parallel must be specified if desired.
Lead sheath, armor, lead sheath and armor or synthetic sheathing can be substituted instead of asbestos braid. Spec ify preference.
These Rockbestos A.V.C. control cables can also be made up with No. 14, 16 and 18 A.W.G. conductors.
TABLE MD (awg No. 12.19/25)
600 VOLTS
TYPE AVA
Number of Conductors
Stranding
Bare Diam.
Inches
Braid Thickness
Finished Diam. Inches
Nominal
Approx. NW|t
in Lbs. per 1000'
tSundard Shipping Length
Feet
Approx. Shipping Weight per 1000'
! 2
3 4
5 6 .7 8
9 10 11 12
13 14 15 10
17 18 19
19/25 19/25 19/25 19/25
19/25 19/25 19/25 19/25
19/25 19/25 19/25 19/25
19/25 19/25 19/25 19/25
19/25 19/25 19/25
.090 .090 .090 .090
.090.090 .090 .090
.090 .090 .090 .090
.090 .090 .090 .090
.090 .090 .090
40 .280 52
45
.545
145
45
.585
180
45
.645
230
45
.710
260
45
.780
305
45
.780
330
45
.850
380
45
.920
435
45
1.000
470
45
1.000
495
45 1.035 535
45 1.065 580
45 1.095 620
45 1.135 670
45
1.160
705
45 1.205 755
45
1.230
790
45
1.230
815
500'R 500' R 500'R 500' R
500' R 500' R 500'R 500' R
500'R 500' R 500' R 500'R
500' R 500'R 500' R 500' R
500' R 500' R 500' R
65 181 225 228
325 381 413 475
544 588 619 669
725 775 838 881
944 988 1019
TABLE MT (awg No. 9-19/22)
600 VOLTS
TYPE AVA
**1 2
3 4
5 6 7 8
9 10 11 12
13 14 15 16
17 18 19
19/22 19/22 19/22 19/22
19/22 19/22 19/22 19/22
19/22 19/22 19/22 19/22
19/22 19/22 19/22 19/22
19/22 19/22 19/22
.127 .127 .127 .127
.127 .127 .127 .127
.127 .127 .127 .127
.127 .127 .127 .127
.127 .127 .127
40 .320
80
45 .630 215
45 .670 275
45 .740 340
45 .820 395
45 .900 475 45 .900 535 45 .985 590
45 1.070 45 1.160 45 1.160
45 1.200
670
735 795 845
45 1.235
915
45 1.275
970
45 1.320 1040
45 1.350 1105
45 1.405 1180 45 1.430 1245 45 1.430 1310
500' R 500'R 500' R 500'R
500' R 500' R 500' R 500' R
500' R 500' R 500' R 500' R
500' R 500' R 500'R 500'R
500'R 500'R 500'R
Q
'Finished diameters fives above ire average. A tolerance of plus or minus 5% is necessary due to variation in process of manufacture. tR--Reefs Single conductor has no cotton braid. Asbestos braid is applied directly over insulation. 'Can be lurniafaed either parallel or cabled with fillers to make round. Specify which.
100 269 344 425
494 594 669 738
838 919 994 1056
1144 1213 1300 1381
1475 1556 1638
RBB 00482
n
t Sizes 16-8
ROCKBESTOS A.V.C.
LIGHTING WIRE
NEC TYPE AVA--ROCKBESTOS A.V.C 600 VOLT SOLID CONDUCTOR
MAXIMUM OPERATING TEMP. nOC (230Fl
Sizes *4/0
*a
t
a'
APPLICATIONS
SPECIFICATION
This wire is recommended for lighting and control circuits
Construction--Sizes 6-4/0
i
in boiler rooms, steel mills, steam runnels, power, chemical
1. Solid Plain Copper Conductor
and food processing plants. Also around furnaces, ovens,
2. Felted Asbestos
glass lehrs, forging presses, tenter frames, soaking pits--and
3. Varnished Cambric
in locomotives, resistors, cranes, steam tables, etc. for circuits exposed to heat.
4. Felted Asbestos 5. Asbestos Braid
National Electrical Code Type AVA--listed by Underwrit
You can safely use this lighting wire either open wired or in conduit, ducts or raceways which are exposed to heat and
ers' Laboratories, maximum conductor operating temperature
U0C (230F).
*^
moisture, corrosive fumes, grease, oil or fire hazard. It is also
Construction--Sizes 18*8
used in electrical apparatus for panel and control wiring to insure performance under severe operating conditions. This construction permits continuous operation under tempera tures ranging up to a maximum of 230F.
It has ample moisture resistance for average conditions, but
l. Solid Plain Copper Conductor 3. Varnished Cambric 4. Felted Asbestos 5. Asbestos Braid
National Electrical Code Type AVA--listed by Underwr^ maximum conductor operating temperatu^
if there is a possibility that circuits may be submerged for long periods use Table CL, Rockbestos A.V.C. (N.E.C. Type AVL) 600 volt lead sheathed lighting wire on page 14.
Standard finish colors: Black and white.
Authorized stock items: Black, (white also in sizes Nos 10
12 and 14.)
' ''
table C600 VOLTS___________________________________________________ TYPE AVA
Size
Bare Diam. Inches
1st Felted Wall
18 AWG 16
to 8
0
.040 .051 .064 .081
.102 .128 .162 .182
.204 .229 .258 .289
.325 .365 .410 .460
15 15
15 15 15 20
20 20 20 20
Finuhed diameters lives above ere itsiit. Nat itsitd in National Electrical Code.
Nominal Thic kness -- Mils
VC Insert
30 30 30 30
30 30 30 30
30 30 30 30
50 30 30 30
2nd Felted Wall
20 20 20 20
20 20 20 20
20 20 20 30
30 30 30 30
Asbestos Braid
40 40 40 40
40 40 45 45
45 45 45 45
45 43 45 45
*Nominal Finished
Diam. Inches
.220 .235 .245 .265
.285 .310 .385 .405
.425 .450 .480 .540
.575 .615 .660 .710
Approx. Net Wgt.
in Lbs. per 1000'
28 33 40 50
65 89 135 160
190 230 275 350
430 525 640 785
^Standard Shipping
Length Feet
500'C
500' C 500' C
500' C 500' C 500' R 500'R
500' R 500' R 500'R 500'R
500' R 500'R 500' R 500'R
Apprux. Shipping Weight per lOou'
35
62 81
200
437
981
tolerance of plui or tntoui J*> u necessary due to variation in process of manufacture. T--K--Reels
12
RBB 00483
ROCKBESTOS A.VX. 600 VOLT FLEXIBLE CONDUCTOR
MOTOR LEAD and APPARATUS CABLE
NEC TYPE AVA--ROCKBESTOS A.V.C.
MAXIMUM OPERATING TEMP. 110C (230F)
APPLICATION
This cable was designed and developed to meet the demand for greater resistance to conductor-heating overloads, high ambient temperatures, other destructive conditions and fire hazard. It is widely used in electrical apparatus for coil con nections and motor leads on either AC or DC. Because of its A.V.C. construction it is ideal for wiring transformers, re sistors, hoists, cranes, traction and mill motors which must function under exposure to heat and moisture, corrosive fumes, grease or oil.
SPECIFICATIONS
Construction
1. Flexible tinned copper conductor
2. Felted asbestos
3. Varnished cambric 4. Felted asbestos 5. Asbestos braid
This cable is National Electrical Code Type AVA, maximum operating temperature 110C (2J0F) listed by the Under writers' Laboratories.
Rockbestos Motor Lead and Apparatus Cable is available in voltage ratings up to 5000 volts and may be furnished with extra-flexible conductors. Standard finish colors: Black and white. Authorized stock items; Black.
TABLE L600 VOLTS
TYPE AVA
Size
Stranding
"18 AWG "16
14 12
10 8 6 5
4 3 2 1
0 00 000 0000
250.000 CM 300.000 350.000 400.000
450.000 500.000 550.000 600.000
650.000 700.000 750.000 800.000
900.000 1.000.000
16/.010 26/.010 41/.010 65/.010
I04/.010 133/.0111 133/.0140 133/.0158
133/.0177 133/.0199 133/.0223 259/.0180
259/.0202 259/.0227 259/.0255 259/.0286
427/.0242 427/0265 427/.0286 427/.0306
427/.0325 427/.0342 427/.0359 427/.0375
427/.0390 427/.0405 427/.04I9 427/.0433
427/.0459 427/.0484
Diam. Inches
.045 .059 .075 .095
.120 .167 .210 .237
.266 .299 335 .378
.424 .477 .536 .601
.653 .716 .772 .826
.878 .923 .969 1.013
1.053 1.094 1.131 1.169
1.239 1.307
Nominal Thickness--Mils
1st Felted Wall
vc Insert
2nd Felted Asbestos
Wall
Braid
10 30 15 40
10 30 15 40
10 10
30 30
15 40 15 40
10 30 15 40
10 30 15 45
15 15
30 20 45 30 20 45
15
15
15 20
30 30 30 30
20 45 20 45 20 45 30 45
20 20 20 20
30 30 30 30
30 45 30 45 30 45 30 45
25 25
40 40
40 45 40 45
25 40 40 45
25 40 40 45
25 40 40 45 2,S 40 40 45
40 40 45 30 40 40 45
30 40 40 45 30 40 40 45 30 40 40 45 30 40 40 45
30 40 40 45 30 40 40 45
Nominal
Diam. Inches
.235 .250 .265 .285
310 -370 .430 .460
.490 .520 .555 .630
.675 .730 .790 .855
.955 1.020 1.075 1.130
1.180 1.225 1.280 1.325
1.365 1.405 1.445 1.480
1.550 1.620
Approx. Net Wgt.
in Lbs. per 1000'
30 35 45 55
75 100 150 175
210 255 306 385
470 570 700 850
1030 1205 1380 1555
1740 1905 2100 2305
2440 2570 2780 2855
3223 3590
fStandard Shipping
Length Feet
500' C 500'C 500'C 500'C
500'C 500'C 500' R 500' R
500' R 500' R 500' R 500'R
500'R 500' R 500' R 500'R
500' R 500'R 500'R 500'R
500' R 500' R 500'R 500'R
500' R 500'R 500'R 500'R
500' R 500' R
Approx. Shipping Weight per 1000'
36 41 51 61
81 106 187 218
262 318 381 481
587 712 875 1062
1287 1506 1725 1943
2175 2381 2625 2881
3050 3212 3475 3568
4028 4487
'No^lUced*'Cod."***' A toltnf,n ol plul tainul wtmr, * to variation ir. ptoctu of mamfeom.
R-Rttl*
RBB 00484
T3
LEAD SHEATHED
POWER CABLE
NEC TYPE AVL--ROCKBESTOS A.V.C. 600 TO 5/000 VOLT RATINGS
SINGLE CONDUCTOR- STRANDED
*
*
APPLICATIONS
These Rockbestos Lead Sheathed Power Cables are used for Power and Lighting Circuits exposed to high temperarures in combination with excessive condensation or complete submersion.
Use this cable where a conduit run is exposed to widely vary ing conditions throughout its length, particularly in power stations located on tidewater where certain ducts are some times flooded but where another section of the same circuit is exposed to high temperatures. Also around ash pits where the wetting down of the ashes results in abnormal conden sation.
The Cables listed in this section all conform to NEMA Standards for Asbestos Varnished Cambric wires and cables with lead sheath.
The lead sheath has no effect on the ability of these cables to withstand high temperatures but affords protection against abnormal condensation or complete submersion.
SPECIFICATIONS
Construction
1. Stranded plain copper conductor 2. Felted Asbestos 5- Varnished cambric 4. Felted asbestos 5- Lead sheath
This cable is National Electrical Code Type AVL, listed by the Underwriters' Laboratories and is available in sizes up to 2,000,000 CM. Maximum operating temperatures are as follows:
600 Volt 110C (250F\ 1000 Volt 110C (230F) 2000 Volt 109C (228F) 3000 Volt 106C (222F) 4000 Volt 103C (217F) 5000 Volt 100C (212F)
These cables are our Standard Power Cable constructions with a lead sheath instead of an asbestos braid.
LIGHTING WIRE LEAD SHEATHED (SOLID)
MAXIMUM OPERATING TEMP: nOC (230F)
'
!. SOLID PLAIN COPPER CONDUCTOR
*
2. PEITEO ASBESTOS
**
3. VARNISHED CAMBRIC
4. FELTED ASBESTOS
S. A0 SHEATH
Size
Diam. Inches
TABLE CL
Nominal Thickness - Mils
! Lead
1st Felled Wall
VC Insert
2nd Felted Thickness Wail : inches
600 VOLTS
Nominal i
Diam. 1 Inches :
Approx.
in Lbs. per 1000'
* Standard i
Length Feet
Approx. Shipping Weight per 1000'
TYPE AVI
18 AWG *16
i:
.040 .051 .064
.081
30
25 i 3/64
.245 1
170
500' R ;
30
25 ! 3/64
.255
ISO 500' R '
30
25 : 3/64
.270
200 500' R
30
25 i 3/64
.285
220 500' R
10 .102
30
25 ! 3/64
.310 !
250
500' R
8 .128
30
25 i 3/64
335 i
2S5
500' R
6
.162 15
30
25 3/64
.400 ;
350
500' R
5
.182 15
30
25 3/64
.420 l
420
500' R
4
.204
15
25 ' 3/64
.440 !
465
500'R
.220
15
30
25 ' 3/64
.465 :
520
500'R
_
.258 15
30
25 3/64
.495 i
5S5
500' R
1
.239
20
30
30 . 4/64
.575 |
830
500'R
0 00
000 0000
.325
20
30
30 : 4/64
.610 |
940
500' R
.365
20
30
30
4/64
.650 1
1070
500' R
.410
20
30
30 . 4/64
.695 ;
1225
500' R
.460
20
30
30 i 4/64
.745 i
1415
500'R
'Finished diameters given above are average. A tolerance of plot or minus fK it necejury due to variation in process of manufacture. *R--Reeli Not lined m National Electrical Code.
212 225 250 275
312 356 4-5 525
581 650 731 1037
1175 1337 1531 1768
14
RBB 00485
ROCKBESTOS A.V.C. LEAD SHEATHED
SINGLE CONDUCTOR POWER CABLE
MAX. OPERATING TEMP. 103C (217FI
MAX. OPERATING TEMP. 100C (212F)
Size
Stranding
TABLE EL
18AWG 16
14 12
10 8 6 5
4 3 2 1
0 00 000 0000
250.000 CM 300.000 350.000 400.000
450.000 500.000 550.000 600.000
650.000 700.000 750.000 800.000
830.000 900.000 950.000 1.000.000
1.250.000 1.500.000 1.750.000 2.000.000
7/-0152 7/.0192 7/.0242
V.0305
7/.0385 7/.0486 7/.0612 7/.0688
7/.0772 7/.0867 7/.0974 19/.0664
19/.0745 19/-0837 19/ 0940 19/.1055
37/0822 37/.0900 37/.0973 37/.1040
37/.1103 37/.1162 61/.0950 61/.0992
61/.1032 61/.1071 61/.1109 61/.U45
61/.1180 61/. 1215 61/.1248 61/.1280
91/.1172 91/.1284 127/.1174 127/.1255
TABLE HL
Bare Dram. Inches
.046 .058 .073 .092
.116 .146 .184 .206
.232 .260 .292 .332
.373 .419 .470 .528
.575 .630 .681 .728
.772 .813 .855 .893
.929 .964 .998 1.031
1.062 1.093 1.123 1.152
1.289 1.412 1.526 1.632
Nominal Thickness -- Mils
1st Felted Wail
vc Insert
2nd Felted Wall
Lead Sheath
Thickness Inches
Nominal Finished
Diam.
inches
600 VOLTS
10 30 25 3/64 .270
10
30
25
3/64
.285
10
30
25
3/64
.300
10
30
25
3/64
.320
10 30 25 3/64 .340
10
30
25
3/64
.370
15 30 25 3/64 .420
15 30 25 3/64 .440
IS 30 25 3/64 .470 15 30 25 3/64 .495 15 30 25 4/64 .560 20 30 30 4/64 .620
20 30 30 4/64 .660 20 30 30 4/64 .705 20 30 30 4/64 .760 20 30 30 4/64 .815
25 40 40 5/64 .945
25
40
40
5/64
1.000
25
40
40
5/64
1.050
25
40
40
5/64
1.095
25
40
40
5/64
1.140
25
40
40
5/64
1.180 .
30
40
40
6/64
1.265
30
40
40
6/64
1.300
30
40
40
6/64
1.340
30
40
40
6/64
1.375
30
40
40
6/64
1.405
30
40
40
6/64
1.440
30
40
40
6/64
1.470
30
40
40
6/64
1.500
30
40
40
6/64
1.530
30
40
40
6/64
1.560
30
50
50
7/64
1.770
30
50
50
7/64
1.890
30
50
50
7/64
2.005
30
50
50
7/64
2.110
5000 VOLTS
Approx. Net Wgt.
in Lbs.
per 1000'
195 205 225 250
275 325 395 445
490 550 745 875
1000 1125 1290 1490
1985 2240 2445 2665
2925 3095 3780 3870
4130 4250 4515 4720
5030 5140 5395 5540
7135 8140 9210 10120
tStandard Shipping
Length Feet
Approx. Shipping Weight per 1000'
TYPE AVL
500' R 500'R 500' R 500'R
500'R 500' R 500' R 500'R
500'R 500'R 500' R 500'R
500' R 500' R 500' R 500' R
500' R 500' R 500'R 500' R
500'R 500'R 500'R 500'R
500'R 500'R 500'R 500' R
500'R 500'R 500'R 500' R
500' R 500'R 500'R 500'R
243 256 281 312
343 406 493 556
612 687 931 1093
1250 1406 1612 1862
2481 2800 3056 3331
3656 3868 4725 4837
5162 5312 5643 5900
6287 6425 6743 6925
8918 10175 11512 22650
TYPE AVL
10 AWG 8 6 5
4 3 2 1
0 00 000 0000
250.000 CM 300.000 350.000 400.000
450.000 500.000 550.000 600.000
650.000 700.000 750.000 800.000
850.000 900.000 950.000 1.000.000
7/.0385 7/.0486 7/.0612 7/.0688
7/.0772 7/-0867 7/.0974 19/.0664
19/-0745 19/.0837 19/-0940 19/.1055
37/.0822 37/-0900 37/.0973 37/.1040
37/1103 37/.1162 61/.0950 61/.0992
61/.1032 61/.1071 61/.U09 61/.U45
61/.1I80 61/.1215 61/.1248 61/.I280
.116 .146 .184 .206
.232 .260 .292 -332
373 -419 .470 .528
.575 .630 .681 .728
.772 .813 .855 .893
.929 .964 .998 1.031
1.062 1.093 1.123 1.152
15 120 15 120 15 120 15 120
15 120 15 120 15 120 20 120
20 120 20 120 20 120 20 120
25 120 25 120 25 120 25 120
25 120 25 120 30 120 30 120
30 120 30 120 30 120 30 120
30 120 30 120 30 120 30 120
25 4/64 .565 25 4/64 .595 25 4/64 .630 25 4/64 .655
615 500' R 674 500' R
750 500'R 820 500' R
25 4/64 .680
860 500' R
25 4/64 .705
930 500' R
25
4/64
.740
1010
500' R
30
4/64
.800
1150
>00' R
30
5/64
.870
1480
30
5/64
.915
1645
500' R
30
5/64
.970
1830
500' R
30
5/64
1.025
2055
500' R
40
5/64
1.105
2305
500'R
40
5/64
1.160
2544
500'R
40
6/64
1.240
3095
500'R
40
6/64
1.290
3335
500'R
40
6/64
1.330
3565
40
6/64
1.375
3800
40
6/64
1.425
4040
40
6/64
1.465
4280
500'R
40
6/64
1.500
4495
500' R
40
6/64
1.535
4715
40
6/64
1.570
4930
40
6/64
1.600
5145
500` R
40
6/64
1.630
5398
40
6/64
1.665
5570
40
7/64
1.725
6234
40
7/64
1.755
6430
500' R
'Finished diameter* given above are average. A tolerance of plus or minus i% it necessary due to variation in process of manufacture. tR--Reels
768 842 937 1025
1075 1162 1262 1437
1850 2056 2287 2568
2881 3180 3868 4168
4456 4750 5050 5350
5618 5893 6162 6431
6747 6962 7792 8037
RBB 00486
SPECIAL CONSTRUCTIONS FOR ROCKBESTOS POWER AND CONTROL CABLES
I
I This Rockbestos A.V.C. Control Cable illustrated is one of the many multi
conductor cables designed to meet specific requirements in control and power circuits. They are made up as shown or with either lead sheath or armor only as specified and in ratings ranging from 600 to 3000 volts. (Synthetic sheath ings may also be specified for control cables where temperatures permit.) I This type of cable not only protects operation of circuits exposed to heat and moisture and other severe operating conditions, but also increases the flexi bility of wiring systems and makes circuits mote easily accessible.
The felted asbestos insulation, impregnated with heat, flame and moisture resisting compounds, withstands high temperatures, corrosive fumes, aging and conductor-heating overloads. The lead sheath protects it from excessive condensation resulting from heating and cooling cycles and complete sub mersion. The spiral bronze armor eliminates the need for conduit, an impor tant consideration in capacity expansion programs, as the cable can be run in troughs, up vertical risers or over and around obstructions. Its flame and heat resistant structure will also maintain vital alarm and control system ciri cuits for longer periods under exposure to flame than other conventional , trpcs-
The cable illustrated on this page is a special construction which is typical of ! many "specials" designed by Rockbestos to meet severe oc unusual operating
conditions.
Its construction consists of: Conduit saving bronze armor covering for protection against abrasion. Impregnated jute serve to cushion the armor and to protect the lead sheath from mechanical damage.
I Lead sheathing for protection against immersion or excessive condensation.
I Friction tape to bind the cabled conductors securely together to maintain the | lay.
INDIVIDUAL CONDUCTORS Coded individual cotton braided conductors for easy circuit identification. Felted asbestos beneath the cotton braid impregnated with heat, flame and moisture resistant compounds.
Varnished cambric for high dielectric strength and added moisture resistance Inner wall of felted asbestos to complete the A.V.C. construction serving as a baffle between the varnished cambric and heated conductors.
16
RBB 00487
ROCKBESTOS A.V.C
600 VOLT SWITCHBOARD WIRES t NEC TYPE AVB--ROCKBESTOS A.V.C.
TABLE 8--SOLID
TABU BS--STRANDED.
MAXIMUM OPERATING TEMP. 90C <194F)
1. SOHO OR STRANDED TINNED CORREI CONDUCTOR
2. VARNISHED CAMIRIC
3. FELTED ASIESTOS
4. FUMEFIOOF COnON (RAID
FOR SWITCHBOARDS, RADIO AND TELEVISION TRANSMITTERS, MOTOR DRIVEN RHEOSTATS, CONTROL PANELS FOR MOTOR STARTERS, ELEVATORS, FIRE DOORS. CRANES, INDUCTION HEATING APPARATUS, OIL BURNING BOILER UNITS, ETC
Standard finish colors; Gray and Black. Authorized stock items: Gray.
TABLE B (Solid)
Size
18AWG 16 14 12
10 8 6 5 4
"2
0 00 000 0000
Bare Diets. Tnriwi
.040 .051 .064 .081
.102 .US .162 .182
.204 .229 .258 .289
.325 .365 .410 .460
600 VOLTS
Nominal Thickness -- Mils
VC
Felted Wall
CoROO Braid
Nominal Finished
Diam. Inches
30 20 16 .175 30 20 16 .185 30 20 16 .200 30 20 16 .220 30 20 17 .240 30 20 17 .270 40 30 17 .340 40 30 17 .360 40 30 17 .360 40 30 20 .415 40 30 20 .445 40 40 20 .495 40 40 20 .530 40 40 20 .570 40 40 20 .615 40 40 20 .665
Apptox. Net Wgt
in Lbs. per 1000'
20 25 30 40
55 80 125 150
175 215 260 330
405 495 610 750
TYPE AVB
l ^Standard j Shipping
I Length 1 Feet
Approx. Snipping Weight per 1000'
1 500* C ! 500'C * 500'C ! 500' C
1 500' C
1 500' C 1 500'R 1 500'R
i 500'R 500' R
1 500' R i 500' R
' 500'R i 500'R i\ 550000'' RR
25 31 36 46
61 86 156 187
218 268 325 412
506 618 762 937
TABLE BS (Stranded)
600 VOLTS
TYPE AVB
Size
| Stranding
16 AWG 14 U 10
8 6 5 4
3
0
00 000 0000
! 7/.0192 : 7/.0242 77.0305
7/.0385
7/.0486 7/.0612 7/.0688 7/.0772
7/.0867 7/.0974 19/.0664 19/.0745
19/.0837 19/.0940 19/.1055
Bare Diam. Inches
.058 .073 .092 .116
.146 .184 .206 -232
.260 .292 .332 .573
.419 .470 .528
Nominal Thickness --Mils
vc
Felted Wall
Cotton Braid
30 20 16 30 20 16 30 20 16 30 20 17
30 20 17 40 30 17 40 30 17 40 30 20
40 30 20 40 30 20 40 40 20 40 40 20
40 40 20 40 40 20 40 40 20
^Nominal Finished
Diam. Inches
.190 .205 .225 .250
.280 .360 .380 .415
.440 .475 .535 .575
.620 .670 .730
Approx. Net Wgt.
in Lbs. per 1000'
25 35 45 60
80 130 150 185
225 280 345 420
515 630 780
tScandard Shipping
Length Feet
500'C 500' C 500' C
500'C
500' R 500'R
500' R 500' R 500' R 500'R
500'R 500' R 500'R
Approx. Shipping Weight per 1000'
31 41 51 66
86 162 187 231
281 350 431 525
643 787 975
'Finished diameters given above are average. A tolerance of plus or minus S% i* etcessary due to variation in process of manufacture. tC--Coils, R--Reels
17
RBB 00488
ROCKBESTOS A.V.C.
600 VOLT SWITCHBOARD HINGE CABLE
NEC TYPE AVB--ROCKBESTOS A.V.C.
MAXIMUM OPERATING TEMP. 90C (194F)
1. STtANOCD TINNED COKM CONOWCTOI
a 2. FELTED ASISSTOS
< 3. VAINISHID CAMMIC
4. KITED AJIESTOS
J. FLAMEMOOF COTTON IIAID
FOR HINGE AND JUMPER CONNECTIONS ON SWINGING INSTRUMENT AND SYNCHRONIZING METER PANELS. MOTOR LEADS AND APPLICA TIONS SUCH AS LISTED UNDER TABLES B AND BS.
As a companion wire to Rockbestos Switchboard Wire we offer this heat, flame and moisture resisting flexible Hinge Cable. Designed primarily for hinge or jumper connections on swinging instrument and synchronizing meter panels, etc., it is also used in various applications in electrical appara tus to maintain dependable performance. It may also be used for conduit wiring where conditions ate not severe enough to require an asbestos braid.
Standard construction employs a flexible stranded, tinned copper conductor,
insulated with a felted wall of asbestos, an insert of varnished cambric tape,
another wall of felted asbestos, impregnated with flameproof and moisture
resisting insulating compounds, and a cotton braid finished with flameproof
I compound.
Showing application of Rockbestos Table
* The diameters of Rockbestos Hinge Cable are approximately the same as those of other Rockbestos Switchboard Wires, and braid finishes are identi
BH 600 Volt Hinge Cable to swinging panel.
cal to assure matching appearance when used on the same board.
Rockbestos A. V. C. Hinge Cable is designated as National Electrical Code Type AVB, has a maximum operating temperature of 90C (194F) and is listed by the Underwriters' Laboratories. It complies with the NEMA Small Wiring for Switchboards Standard and is approved by Factory Mutual Laboratories, switchboard manufacturers and power companies.
Standard finish colors: Gray and black. Authorized stock items: Gray. Be sure to specify braid color desired on or der.
I
TABLE BH
600 VOLTS
TYPE AVB
Size
Stranding Tinned
Bare Diam. Inches
Nominal Thickness -- Mils
1st Felted Wall
VC 1 2nd Felted Insert i Wall
CoitOD Braid
Nominal Finished
Diam. Inches
Approx. NecWgt.
in Lbs. per 1000'
^Standard Shipping
Length Feet
Approx. Shipping Weight per 1000'
* 18 AWG *16
14 12 10 8
16/.010 26/.010 41/.010 65/.01O 104/.010 133/.01U
.045 .059 .075 .095 .120 .167
10 10 10 10 10 10
30 30
1!
15
I?
30 i 15
30 1 u
30 15
30 : 15
16 .190 16 .205 16 .220 17 .240 17 .265 17 .515
25
500'C
31
30
500'C
36
35
500'C
41
45
500' C
51
60
500' C
66
90
500'C
96
*Fimtbd diameter* liven above are sveufe. A tolerance of plus or minus 5% 1# necessary due to variation to process of manufacture. tC--Coils Not listed in National Electrical Code.
%
ie
RBB 00489
ROCKBESTOS THERMOPLASTIC and ASBESTOS
600 VOLT SWITCHBOARD WIRES
AND FLEXIBLE HINGE CABLE
National Electrical Code Type TA TAEIE XB, SOLID--TABLE XBS, STRANDED TABU XBH, FLEXIBLE STRANDED HINGE CABLE
MAXIMUM OPERATING TEMP. 90C (194F)
t*
a
1. SOLID OE STtANPED TINNED COME* CONDUCTOI
2. THERMOPLASTIC INSULATION
3. PELTED ASIESTOS
' FOR SWITCHBOARDS, CONTROL PANELS AND HINGE CONNECTIONS
Standard finish colors: Gray and black. Authorized stock items: Gray.
4. PUMEPROOF COTTON IRAIO
TABLE XB (Solid)600 VOLTSTYPE TA
Size
Bare DiaiD. Inches
Minimum Thermoplastic
Insulation Mils
Nominal Thickness--Mils
Felted Wall
Cotton Braid
^Nominal Finished
Diam. inches
Approx. Net Wgt.
in Lbs. per 1000'
tSuodird Shipping Length
Feet
Approx. Shipping Weight per 1000'
18 AWG 16
14 12
10 8 6 5
4 3 2 1
0 00 000 0000
.040 .051 .064 .081
.102 .128 .162 .182
.204 .229 .258 .289
.325 .365 .410 .460
20 20 20 20
20 20 30 30
30 30 30 40
40 40 40 40
20 20 20 20
20 20 25 25
25 25 25 30
30 30 30 30
TABLE
9
Size
XBS (Stranded)600
Stranding
Bare Diim. Inches
VOLTS
Minimum Thermoplastic
Insulation Mils
16 16 16 16
16 17 17 17
17 17 20 20
20 20 20 20
Nom. Thickness -- Mils
Felted Wail
Cotton Braid
.160 .170 .185 .200
.225 .250 .315 .335
.360 .385 .420 .480
.515 .555 .600 .650
20 25 30 40
55 75 120 145
175 210 260 330
405 495 605 750
500' C 500'C 500' C 500'C
500'C 500'C 500' R 500' R
500' R 500' R 500' R 500'R
500' R 500'R 500'R 500' R
26 31 36 46
61 81 150 181
218 262 325 412
506 618 756 937
____ _____________ TYPE TA
Nominal Finished
Diam. Inches
Approx. Net Wgt.
in Lbs. per 1000"
^Standard Shippiog Length
Feet
Approx. Shippiog Weight per 1000'
18 AWG **l6
14 12
10 8 6 5
4 3 2 1
0 00 000 0000
7/.0152 7/.0192 7/.0242 7/.0305
7/.0385 7/.0486 7/.0612 7/.0688
7/.0772 7/.0867 7/.0974 19/.0664
19/.0745 19/.0837 19/.0940 19/.1055
.046 .058 .073 .092
.116 .146 .184 .206
.232 .260 .292 332
373 419 .470 .528
20 20 20 20
20 20 30 50
30 30 30 40
40 40 40 40
20 16 .165 20 500' C 26
20 16 .180 25 500'C 31
20 16 .195 32 500' C 38
20
16 .215
41
500'C
47
20 17 .240
56 500'C 63
20 17 .270 79 500'C 85
25
17 -340
125
500' R
156
25
17
.365
150
500'R
187
25
17 .395
180
500' R
225
25
20
.425
240
500" R
300
25
20
.455
265
500' R
331
30
20
.525
345
500' R
431
30
20 .565
420
500'R
525
30
20
.610
515
500'R
643
30
20 .660
635
500' R
793
30
20
.720
780
500' R
975
TABLE XBH (Flexible Stranded)
600 VOLTS
TYPE TA
18 AWG 16
14 12
10 8 6 5
4
3 2 1
0 00 000 , 0000
16/.010 26/.010 41/,010 65/.010
104/.010 133/.OUI 133/.0140 133/0158
I33/.0177 133/.01P9 133/.0223 259/.0180
259/.0202 259/.0227 259/.0255 259/.0286
.045 .059 .075 .095
.120 .167 .210 .237
.266 .299 .335 .378
.424 .477 .536 .601
20 20 20 20
20 20 30 30
30 30 30 40
40 40 40 40
20 16 .165 20 500' C 25 20 16 .180 :5 500' C 30 20 16 .195 31 500' C 3' 20 16 .215 42 500'C 47
20 1* .245 5' 500' C 63
20 17 .290 84 500' C 89
25
17
.365
130
500' R
162
25
20
395
160
500' R
200
25
20
.425
190
500'R
237
25
20
.460
230
500' R
287
25
20
.495
280
500' R
350
30
20
.570
360
500' R
450
30
20 .615 435
500'R
543
30
20 .670 535
500' R
668
30
20
.730
660
500' R
825
30
20
.*95
810
500' R
1012
lFinib<l diameter* given above are average. A (oieraoce of plua or minus i% ia neceitary due to variation in proceaa of manufacture. tC--Coils. R--Reels 'Not listed to Natiooal Eleerrical Code.
RBB 00490
1
ROCKBESTOS AIL-ASBESTOS
600 VOLT RHEOSTAT WIRE
National Electrical Code Type AIA MAXIMUM OPERATING TEMP. 125C (257F)
% i. souo aum com* cokouctok
a
3. nine asmstos
I. ASMSTOS MAID
FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES. INFRA-RED DRYERS, OVENS. ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD.
Asbestos rheostat wire was originally produced by putting
I two or three braids of asbestos yam on the wire and finishing each braid with compound. This had several disadvantages. For example, its moisture resistance was very low due to the comparatively open covering so that many engineers consid ered that spaced wiring was necessary in order to prevent possible leakage under damp conditions. The labor cost of doing this type of wiring is high.
Another disadvantage--though really more of an annoyance --was that in working with this wire a good deal of the compound flaked off and continued to do so after the instil* lation was completed, spoiling the appearance of an otherj wise nice job.
The Rockbestos development of the felted and impregnated wall of asbestos insulation was a distinct improvement. In stead of a relatively open covering on the wire, the asbestos is applied in the form of a homogeneous insulation. The dielectric strength is thereby increased. Next, the-impregnat ing compound is an integral parr of the insulating wall, not
painted on after the wall is formed. That means that, through repeated heating and cooling cycles, the compound can never fail away from the asbestos. The dielectric strength and mois ture resistance of Rockbestos Rheostat Wire are, therefore, practically constant. And there is none of the usual flaking when working with Rockbestos Rheostat Wire and Cable, with either white or black braid.
Because of its comparatively high moisture resistance Rockbescos Rheostat Wire may be bunch-wired with safety, and it is also recommended for open wiring carrying less than 600 volts which is subject to high temperatures or rotting, corrosive fumes. For a 300 volt construction of the same type refer to page 24.
This wire is National Electrical Code Type AIA listed by the Underwriters' Laboratories as Type AIA wire and has a maximum operating temperature 125C (257F).
Standard finish colors: Black and white.
Authorized stock items: Black (white also in sizes nos. 6, 8, 10, 12 and 14.
TABLE A
600 VOLTS
TYPE AIA
Size M8AWC '
iO $ 6 4
0 00
Bare Dam. Inches
.040 .05! .004 .081
.102 .128 .102 .182
.204 .229 .258 .289
.525 .>65 .410 .460
Nominal Thickness--Mils
Felted Wail
Asbestos Braid
50 40 30 40 30 40 30 40
30 40 30 40 40 40 40 45
40 45 40 45 40 45 60 45
60 45 60 45 60 45 60 45
Nominal Finished
Darn. Inches
.180 .195 .205 -225
.245 .270 325 -355
375 .400 .430 .500
535 .575 .620 .670
Approx. NetWgc.
in Lbs. per 1000'
22 26 32 42
56 79 115 140
165 205 255 320
395 485 600 745
tSuodard Shipping Length
Feet
500' C 500' C 500'C 500' C
500' C 500' C 500' R 500' R
500' R 500' R 500' R 500'R
500'R 500' R 500'R 500'R
Approx. Shipping Weight per 1000'
27 32 37 47
61 84 143 175
206 256 318 400
493 606 750 931
Finiihed diameters given above ait average. A tolerance of plu> or minui 5% it necessary due to variation in proem of manufacture. tC--Coils. R--Reels Nor listed in National Elecrrical Code.
20
RBB 00491
ROCKBESTOS ALL-ASBESTOS
600 VOLT POWER and RHEOSTAT CABLE
National Electrical Cede Type AIA MAXIMUM OPERATING TEMP. 125C (257F)
1. ST1ANDEC PLAIN COPPf* CONDUCTOI
la
FtlTtD ASMSTOS
3
3. ASIESTOS IPAID
FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES. INFRA-RED DRYERS. OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES. CORROSIVE FUMES. GREASE. OIL OR FIRE HAZARD.
This wire is listed by Underwriters' Laboratories as Type AIA wire.
Standard finish colors: Black and white. Authorized stock items: Black (white also in si2e$ nos. 12 and 14).
For 300 volt construction refer to page 24, Table RF-300. Rockbestos High Temperature Rheostat Wire,
TABLE R
600 VOLTS
TYPE AIA
Size
Stranding
Bare Diam.
Inches
Nominal Thickness -- Mils
Felted Wall
Asbestos Braid
Nominal Finished
Diam. Inches
Approx. NetWgt.
in Lbs. per 1000'
-^Standard Shipping
Length Feet
Approx.
Shipping Weight per 1000'
18 AWG 16
14 12
10 8 6 5
4 5 2 1
0 00 000 0000
250.000 CM 300.000 350.000 400.000
450.000 500.000 550.000 600.000
650.000 700.000 750.000 800.000
850.000 900.000 950.000 1.000.000
7/.0152 7/.0192 7/.0242 7/.0305
7/.0385 7/.0486 7/.0612 7/.0688
7/.0772 1'0867 7/.0974 19/.0664
19/.0745 I9/.0837 19/.0940 19/. 105 5
37/.0822 37/.0900 37/.0973 37/.1040
37/.1103 37/.1162 61/.095G 61/.0992
6I/.1032 61/.1071 61/.1109 61/.1145
61/.U80 6I/.1215 61/.1248 61/.1280
.046 .058 .073 .092
.116 .146 .184 .206
.232 .260 .292 .332
.373 .419 .470 .528
.575 .630 .681 .728
.772 .813 .835 .893
.929 .964 .998 1.031
1.062 1.093 1.123 1.152
30 30 30 40
40 40 60 60
60 60 60 75
75 75 75 75
90 90 90 90
90 90 105 105
105 105 105 105
105 105 105 105
40 40 40 40
40 40 45 45
45 45 45 45
45 45 45 45
45 45 45 45
45 45 45 45
45 45 45 45
45 45 45 45
.190 .200 .215 .255
.280 .310 395 .420
.445 .470 .505 .575
.615 .660 .710 .770
.845 .900 .955 1.000
1.045 1.085 U55 1.195
1.230 1.265 1.300 1-335
1.365 1.395 1.425 1.455
22 28
4u7
64 90 130 155
185 225 270 345
420 520 635 785
920 1080 1245 1405
1570 1730 1890 2080
2240 2415 2560 2730
2890 3050 3215 3375
500' C 500' C 500' C 500'C
500' C 500' C 500' R 500' R
500' R 500' R 500' R 500' R
500' R 500' R 500' R 500' R
500' R 500' R 500' R 500' R
500' R 500'R 500'R 500' R
500' R 500' R 500' R 500' R
500'R 500'R 500'R 500'R
"t t
33 39 53
69 94 162 193
231 281 337 431
525 650 793 981
1150 1350 1556 1756
1962 2162 2362 2600
2800 3018 3200 3412
3612 3812 4018 4218
Finished diameters givtti abovt *> average. A tolerance of plus or minus S% is necessary due ro variation in process of manufacture. tC--Coils. R--Reels **Not listed in National Electrical Code.
21
RBB 00492
ROCKBESTOS ALL-ASBESTOS
600 VOLT
FLEXIBLE APPARATUS CABLE
*v MAXIMUM OPERATING TEMP. J25C (257F)
S II
1. FlfXIILf TINHtO comt CONOUCTOt
2. Flino AJMSTOS
3. AMESTOJ IUJ0
FOR FLEXIBLE LEADS AND CONNECTIONS OF APPARATUS SUCH AS LISTED UNDER TABLES "A" AND "R---OVENS. FUR NACES. DRYERS, AUTOMOTIVE BUS IMMERSION HEATER LEADS. BATTERY LEADS AND ENGINE COMPARTMENT WIRING.
This cable is recommended wherever flexible leads or con nections must be used in open*wired high temperature installations.
Steel mills sometimes use this cable for motor leads exposed to heat where the possibility of a moisture condition is re mote. it will not deteriorate under constant high ambient temperatures and is highly resistant to corrosive fumes, flame, grease and oil, characteristics which make ft ideal for jumper leads, etc. (For high dielectric strength and moisture resist ance see Rockbestos A.V.C. Motor Lead and Apparatus Cable on page 13.) 1 Automotive bus manufacturers and operators use it foe en-
j gine compartment wiring and leads for batteries, crank case
and radiator immersion heaters because of its high resistance to heat and flame. (For smaller diameter cable for these applications and diesel locomotive control circuit wiring in quire about special Type ACA engine compartment or con trol cables.) This cable is National Electrical Code Type AIA and is listed by the Underwriters' Laboratories' as Type AIA wire. Maximum operating temperature is 125C (257F). Stand ard finish colots: Black and white. Authorized stock item: Black- This cable an be made up with extra flexible stranded tinned conductor if tequired. For 300 volt construction refer to page 24, Table RF-300.
TABLE RF
600 VOLTS
TYPE AIA
Size
1 Stranding
Bare Diana. Inches
Nominal Thi ckness-- Mils
Felted Wall
Asbestos Braid
Nominal Finished
Diam. Inches
Approx. Net Wgt.
in Lbs. per 1000'
tStandard Shipping
Length Feet
Approx. Shipping Weight per 1000'
IS AWG *16
14
13
10 8 6 5
' i ;
i
i : : ;
16/.010 26/.010 41/.010 65/.010
104/.010 133/.01U 13 3/.0140 133/0158
.045 .059 .075 .095
.120 .167 .210 .237
30 30 30 40
40 40 60 60
40 40 40 40
40 40 45 45
.185 .200 .215 .255
.280 -330 .420 .450
23 27 34 49
65 94 135 165
4 i 133/.0177 3 : I33/.OI99
133/0223 1 : 259/.0180
.266
.299 335 .378
60 60 60 75
45 45
45 45
.460 .510
.545 .620
195 235 285 360
0 00
000
0000
i 259/.0202 : 259/.0227
. 259/.0255 . 259/.0286
.424 .477
.536 .601
75 75 75 75
45 43 45
45
.665 .720 .780
.845
445 540 665 810
230.000 CM ! 42V.0242
500.000
. 427/.0265
550.000
1 427/.0286
400.000
i 427/.0306
.653 .716
.772 .826
90
90 90 90
45
.925
985
45
.990
1120
45
1.045
1330
43
1.100
1460
450.000 500.000
1 427/.0325 427/.0342
.878 .923
90 90
45
1.150
1690
45
1.195
1805
500'C 500'C 500' C 500' C
500'C 500'C 500' R 500' R
500' R 500' R 500' R 500' R
500' R 500' R 500'R 500' R
500'R 500' R 500' R 500' R
500' R 500' R
^7 32 39 54
71 99 168 206
243 293 356 450
556 675 831 1012
1231 1400 1662 1825
2112 2256
Finished diameters liven above are average. A tolerance of plus or minus 5% is necessary due to variation in procew of manufacture. +C--Coils. R--Reels Not listed in National Electrical Code.
22
RBB 00493
ROCKBESTOS ALL-ASBESTOS
300 VOLT EXTRA FLEXIBLE
APPARATUS CABLE
National ileetrltal Codo Type AA
MAXIMUM OPERATING TEMP. 150C (302P)
This cable was originally developed as "Motion Picture Cable" for specific use in motion picture projector lamp houses and sun-arc lamps, but its use has been extended to product and industrial applications requiring extra-flexible insulated conductors that will resist the baking effects of high temperatures.
The felted asbestos insulation and the asbestos braid are both impregnated with heat and flame resisting compound to assure the highest possible resistance to heat and maximum flexibility. The braid finish is white.
This cable is National Electrical Code Type AA, listed by the Underwriters' Laboratories as Type AA wire and has a maximum operating temperature of 150C (J02F). Strand ed Copper conductors employing No. 27 AWG or smaller strands limited to 150C (302F) by Underwriters' Lab oratories. It will remain flexible under continuous operation at rated temperature, doesn't bum or support combustion even when exposed to an arc, and has typical Rockbestos resistance to-fumes, grease or oil.
Standard finish colors: White and black. Authorized stock items: White:
TABLE W
300 VOLTS
TYPE AA
Size
Stranding
Bare Diam. Inches
Nominal Thickness--Mils
Felted Wall
Asbestos Braid
Nominal Finished
Diam. Inches
Approx. Net Wgt.
in Lbs. per 1000'
tStandard Shipping Length
Feet
Approx. Shipping Weight per 1000'
*18 AWG
41/34
.047
30
40
.190
**16 14
65/34
.061
30
40
.205
104/34
.077
30
40
.220
12
259/36
.102
30
40
.245
30 41
10
8
6 4
413/36
.130
30
40
.270
58
665/36
.165
30
40
.305
75
1050/16
.205
40
45
3"5 115
1666/36
.275
40
45
.445 170
2
2646/36.
.350
40
45
.520
255
1
3332/36
.400
60
45
.610
330
0
4214/36
.440
60
45
.650
410
00
5292/36
.500
60
45
.710
500
000 0000
6713/36
.570
60
45
.780
630
8512/36
.640
60
45
.850
780
500'C 500'C 500' C 500' C
500' C 500'C 500' C 250'C
200' C 200'C 200' C 200' NR
200' NR 200' NR
23 28 36 47
63 80 121 176
262 337 417 507
637 78?
Finished diameter* given above are average, a tolerance of plus or minui SEfc ia necetaxrr due ro variation in process of manufacture. tC--Coils NR--Nonreturnable Reel*.
Not lined in National Electrical Code.
RBB 00494
23
6? rr
ROCKBESTOS ALL-ASBESTOS 300 VOLT HIGH TEMPERATURE
RHEOSTAT WIRE
MAXIMUM OPERATING TEMP.: 200C (392F) -- TABLES A-300, R-300 150C (302F) TABLE RF-300
it
t
I. SOHO O* STlANPtO FIAIN COFFE4 CONDUCTORS
J. tUTCO AU6STQ4
ati
J. SlOS **10
FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES, INFRA-RED DRYERS. OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD.
CONDUCTORS: TABLE A-300 (SOLID) TABLE R-300 (STRANDED) TABLE RF-300 (FLEXIBLE STRANDED) These wires are listed by the Underwriters' Laboratories as Type AA wire. Standard braid finishes are white and black---colors on special order.
TABLE A-300 (Solid)
300 VOLTS
TYPE AA
Size
**18 AWG '16
14 12 I 8
Bare Diam. Inches
.040 .051 .064 .081 .102 .128
! Nominal Thickness -- Mils
j Felted | Wall
i Asbestos j Braid
` 30 1 40
! 30
40
11
3300
i 40 i 40
: 50
40
i 30 1 40
'Nominal j Approx.
Finished
i Net Wgi.
Diam.
J in Lbs.
Inches
1 per 1000'
.180 .195 .205 .225 .245
.270
! l j
| i
18 22 28
38 52 69
tStandard Shipping Length
Feet
500'C 500'C 500'C 500'C 500'C 500' C
| Approx. : Shipping
Weight : per 1000'
: 22 ! 28
33 > 45 . 57
79
Finished diameter* given above are average. A tolerance of plot or minus s% is necessary due to variation in process of manufacture. tC--Coils
TABLE R-300 (Stranded)
Size
i,, . Bare
Diam.
Stranding
Inches
IS AWG 16
14
12 10 8
7/.0152 i .046 7/.0192 ! .058 7/.0242 \ .073 7/.0305 ! .092 7/.0385 i .116 7/.0486 ! .146
300 VOLTS
TYPE AA
Nominal Thickness -- Mils ! 'Nominal i Approx.
tStandard i Approx.
------ Finished ; NetWgt.
Felted J Asbestos >
Diam.
Wall
Braid
Inches
1 per 1000'
Feet
per 1000'
30 ! 40 ; .190 '
50 j 40 30 i 40
.200 .215
: I
30 ' 40 ' .235 1
50 ! 40 i .260 1
30 40
.290
i
18 1 500' C
25 1 500'C :
29 1 500' C '
44 j 500' C
54 1 500' C
72
500' C
:
24 28 35
45 60 83
TABLE RF-300 (Flexible Stranded)
300 VOLTS (Maximum Operating Temp. 150C) TYPE AA
*`18 AWG *'16
14 i: 10 s
16/.0I0 26AOIO 41/.010 M/om
104/.010 133 '0 til
' .
.045 .059 .075 .095
.167
30 40 30 40 50 40
50 : .io 30 40 30 ; 40
.185 .200 .215 .235 .260 .307
; 1 ' i
1
IS 500' C 23 ' 500' C 40 ' 500' C 40 500' C 56 ' 500' C 75 p 500' C
Fmijhed diameter* given above are average. A tolerant* of plua or minus Not luted m National Electrical Code.
<i neeetsiry due to vitiation in proem of manufacture. +C--Coili
24 28 35 46 61 88
24
RBB 00495
ROCKBESTOS ALL-ASBESTOS
300 VOLT FIXTURE WIRES
Noflona/ Electrical Code Type AF MAXIMUM OPERATING TEMP. 150C (302F>
WHITE ASMSTOS INSULATION
IACX AMESTOS INSULATION
SOLID COLOR (RAID
SOLID COLOR (RAID WITH MARKER
FOR LIGHTING FIXTURES, SUN LAMPS, OFFICE EQUIPMENT, RADIO APPARATUS, LEADS FOR SMALL MOTORS AND TRANS FORMERS, MINIATURE SWITCHBOARDS, ETC.
These heat resisting fixture wires are used for lighting fix tures, sun lamps, office equipment, radio apparatus, leads fot
small motors and transformers, miniature switchboards, etc. They are approved by the Underwriters' Laboratories for lighting fixture wiring and bear their labels. For fixtures where the wiring is concealed in stems or brack ets, the PLAIN type wire is recommended. It has no braid. Made in blade and white to indicate polarity. When wiring is exposed, such as on a chain pendant fixture,
ie BRAIDED wire is recommended. Made in solid color
raids and solid color with marker thread to indicate polarity. ORDERING INFORMATION Standard Packing: Both plain and braided fixture wires are put up on metal spools and in coils, and where quantity warrants (5000 to 10,000 feet depending on size) on fac tory reels.
Rockbestos plain fixture wire is furnished in standard colors, black, white and ted. Green, yellow, gray, orange and brown can be furnished to order. Authorized stock items: Black and white. Rockbestos braided fixture wire is finished in standard colors, mahogany brown and black in glazed cotton. Other colors and polarity marker threads can be furnished to order.
In ordering specify: A.W.G. size and stranding. Whether plain type or braided type. If plain whether half the order black, other half white finish, or all one color. If braided type, whether half order solid color braid, other half with marker or all one way. Color of braid.
TABLE FS
Size
i t
|
18AWG | 16 !
14 : 12 . 10
iplain)
Stranding
16/30 26/30 41/30 65/30 104/30
Bare Diam. Inches
.045 .059 .075 .095 .120
300 VOLTS
Min. Felted Wall Mils
] -Nominal i Finished [ Diameter i Inches
31 j .110 31 ! .125
31 1 .140 47 : .190 47 i .210
Approx. Net Wgc.
in Lbs. per 100O'
10 14 20 34 48
^Standard Shipping
Length Feet
500' S 500* S 500'S 500' S 500' C
TYPE AF
Approx. Shipping Weight per 1000'
12 l? 25 37 51
TABLE FSB (BRAIDED
300 VOLT
TYPE AF
18AWG : 16 14 12 ` 10
16/30 26/30 41/30 65/30 104/30
.045 .059 .075 .095 .120
31 1 .140
31 . .155 31 : .170 47 i .220 47 i .240
12
500'S
14
16
500'S
19
22
500' S
25
37
500' S
40
52
500' C
55
Fmijhed diameters given aBnve are avenge. A tolerance ( plus ot minus 5Cr it necessary 4u to vitiation U process of manufacture. tC--Coils. $--Spools
RBB 00496
25
27
RBB 00498
ROCKBESTOS A.V.C.
600 VOLT MINING CABLE
MAXIMUM OPERATING TEMP. U0C (230F)
4 >*
I. FLEXIBLE TINNED COFFEE CONDUCTOI
2, FELTED ASIESTOS
1 1. VAENLSMED CAMEEIC
4. FELTED ASMSTOS
1 ASBESTOS ItAIO
FOR ALL INTERNAL CIRCUITS Of ELECTRIFIED MINING EQUIPMENT
This original Rockbestos A.V.C Mining Cable was designed to meet requirements for a cable that would operate depend ably under the unusual conditions prevailing in the mining industry and is not a National Electrical Code Standard.
Similar in construction to Rockbestos A.V.C. Motor Lead Cable, but made to diameters that fit equipment bushings properly, its impregnated felted asbestos insulation and heavy asbestos braid withstands conductor-heating overloads and the heat of resistor grids in the tightly sealed compart ments of permissible equipment. It won't burn or carry flame.
won't bloom, rot or flow under exposure to grease or oil, and has ample resistance to moisture and the destructive action of alkaline water.
Standard of leading mining machine manufacturers for de pendability and safety since 1928, it is widely used by mine electricians to keep equipment in full-time operation and reduce maintenance.
NOTE: This cable is not designed or intended for use as drag or reel cable. To avoid error specify Table ML, Rock bestos A.V.C. for use in cutters, loaders and locomotives.
Standard finish colors: Black and white. Authorized stock item: Black.
TABLE ML
600 VOLTS
Size
Stranding
Bare Diam. Inches
Nominal Thickness -- Mils
1st Felled Wall
VC Insert
2nd Felted Wall
Asbestos Braid
Maximum Finished Diam. Inches
Approx.
NetWgt. in Lbs.
per 1000'
14 AWG
41/.010
.075
10
40
10
27 1/2
.273
40
12
65/.010
.095
10
40
10
27 1/2
.294
51
10
104/.010
.120
10
40
10
27 1/2
.313
6i
S
133/.01U
.167
10
40
10
27 1/2
359
95
6
133/.0140
.210
10
40
5
I33/.OI58
-237
10
40
4
I33/.0177
.266
10
40
3
133/.0199
.299
10
40
10
27 1/2
.405
10
27 1/2
.428
10 35
.473
10 35
.506
135 160 195 235
2
133/0223
.335
10
40
10 35
1
259/.0180
.378
15
40
15 45
0
259/.0202
.424
15
40
15 45
00
259/.0227
.477
15
40
15 45
.546 .620
.669 .716
285 370
450 550
000
259/0255
.536
15
40
15 45
.779
675
0000
259/0286
.601
15
40
15 45
.849
825
250.000 CM
427/.0242
.653
20
40
40 45
.988
1020
300.000
427/.0265
.716
20
40
40 45
1.056
1195
350.000 400.000
450.000
427/0286 427/0306 427/.0325
.772
.826 .878
20 20 20
40 40 40
40 45
40 45 40 45
1.115 1.172
1.226
1370 1545 1730
500.000
427/0342
.923
20
40
40 45
1.274
1895
"Minimum diameter *2*/j<7c of maximum diameter. *C--Coil*. R--.Reel*
tStandard Shipping Length
Feet
500'C 500' C 500'C 500' C
500' R 500' R 500' R 500' R
500'R 500' R 500'R 500'R
500'R 500' R 500' R 500' R
500'R 500'R 500' R 500' R
Approx. Shipping Weight per 1000'
45 56 72 100
168 200 243 293
356 462 562 687
843 1031 1275 1493
1712 1931 2162 2368
26
RBB 00497
ROCKBESTOS TYPE ACA 1000 VOLT
LEAD and HOOKUP WIRES
TABLE EMA 1000 VOLT LEAD WIRE
MAXIMUM OPERATING TEMP. 90C (194F)
<mmhi..hrw
STRANDED
TINNED COPPEK
SYNTHETIC TAPES
FELTED ASIESTOS
GLAZED COTTON
HAID.UCOUEI FINISH
This 1000 Volt ACA Lead Wire had its inception in appli cation wiring with the advent of cold cathode--slim line-- and mercury vapor fixtures where the initial starting voltages exceed 300 volts, thereby eliminating the use of 300 Volt AT Wire. It had a distinct advantage in its small diameter. Because of this feature, it has also found usage in some in dustrial instrumentation and control circuits in conduit when its use does not conflict with the requirements of the National Electrical Code.
Additional uses for this wire are foe automotive bus engine compartment wiring and diesel locomotive circuit wiring. Rockbestos 1000 Volt Lead Wire is constructed with non flowing, thin-walled, helically applied synthetic tape and felted asbestos insulation. This construction covered with a glazed cotton braid lacquer finish results in a small diameter wire with high dielectric strength. This wire strips easily and is resistant to heat, cold, flame, moisture, grease and oil.
TABLE ZM
1000 VOLT HOOKUP WIRE
MAXIMUM OPERATING TEMP. 125C (257Is)
stranded TINNED
COPPER
synthetic TAPES
felted ASIESTOS
lacquered CLASS IIAID
Here is a Hookup Wire which has developed many product and electrical maintenance applications. It is similar in con struction to the 1000 Volt Lead Wire shown on this page with the exception that it is covered with a lacquered glass braid overall and is recommended for applications in which abrasion resistance requirements are less severe than for Table EMA. This hookup wire was originally developed along govern ment specifications for a glass braided wire suitable for use within electronic devices and instruments which would have high dielectric strength, small diameter and stability in a broad range of operating temperatures. Like Table EMA on this page, Rockbestos 1000 Volt ACA Hookup Wire is resistant to heat, cold, flame, moisture, grease and oil. It can be terminated easily because it strips cleanly and withstands the heat of soldering. This wire can be color coded as illustrated bv the use of colored tracers inserted in the white glass braid.
TABLE EMA (cotton braid)
1000 VOLTS
| Stranding
Size
14 AWG | 19/0142 12 1 19/.0179
i
Bare Diam. Inches
071 .090
Nom. Thickness--Inches
Svmheuc Tape
Felted Wall
Braid Thickness
.010 .010
.020 .020
.0125 .0125
TABLE ZM (GLASS BRAID)
1000 VOLTS
'Nominal Finished
Diam. Inches
.156 .175
Approx. Net Wgt.
in lbs. per 1000'
23 31
TYPE ACA
tStandard Shipping
Length Feet
Approx. Shipping Weight per 1000'
500' C 500' C
28 36
TYPE ACA
18 AWG 16 14 12 10
j
16/.010 26/.010 41/.010 65/010 104/.010
.045 .059 .075 .095 .120
.0065 .0065 .010 .010 .010
.0085 .0085 .0085 .010 .010
.0075 .010 .010 .010 .010
.090 .109 .132 .155 .180
8 *1000' 12 '*1000' 19 **1000' 28 **1000' 42 *1000'
'Finished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. +C--Coils. **Non*Rerurnabie reels or metal spools
12 16 23 32 48
27
RBB 00498
ROCKBESTOS A.V.C.
Aftft wrst T U1MIMA
ROCKBESTOS
THERMOSTAT CONTROL WIRE
l. CMAMCLCO corn* CONBUCTO*
3- fOlAIUEO mtlD AJWSTOS
3. COATED STEI1 AKMOK
FOR LOW VOLTAGE SIGNAL, INTERCOMMUNICATIONS AND ALARM SYSTEMS, FUEL BURNER CONTROLS, GAS BURNER SAFETY PILOTS, OVENS, HEATERS, FURNACES, INDUSTRIAL DRYERS, AIR CONDITIONERS, APPARATUS, ETC.
The wiring of the control systems of early automatic coal and oil burning installations formerly gave frequent trouble. To get shcit runs it was often installed dos* to, ot actually resting on, hot water or steam pipes and the heat naturally deteriorated ordinary insulated wire to the point where trou ble frequently occurred. Cases are on record where serious damage has resulted from faulty control wiring.
Abrasion, too, has always been a source of trouble when fish ing ordinary control wire, particularly in buildings already up. Sharp corners, brickwork, plaster, protruding nails and rough beams all tend to damage the insulation.
With these conditions in mind, and with the wide adoption of automatic fuel burning systems, a large manufacturer of heat control apparatus asked us to design a wire which would be heatproof and abrasion resisting--and Rockbestos Ther mostat Control Wire was the result.
Rockbestos Thermostat Control Wire is very sttong mechan ically because of its firm felted asbestos insulation and its rugged, abtasion resisting spiral steel armor or metal braid.
It is heatproof and will not dry out under heat or with age. It eliminates fire hazard because it cannot burn. Neicher can tats damage it as has been known to happen occasionally with unprotected wires. Where resistance to abrasion or protection against rodents is not essential, a cotton braid may be speci fied instead of metallic sheath. With these advantages it is of value for control and intercommunicating systems or for any similar application where a low voltage, multi-conductor cable is required.
Rockbestos Thermostat Control Wire is designed to be useJ
at low voltages, usually fed by a step-down transformer. For this application the 12 i/2 mil wall insulation is generally used, rfowever, some users prefer the 25 mil insulation thick ness for its added mechanical and dielectric strength. Where this cable is to be used direct on 115 vole circuits a minimum insulation thickness of 31 mils is recommended. Data for cables with all three insulations is listed in the table below.
Noth: The metal braid covering mentioned in the fourth paragraph is an optional suggestion.
TABLE TC 127* mil.
TABLE TCC 25 mil.
TABLE TCS 31 mil.
Nominal Wail Thickness Finished Diameters* (Inches)
Size A.W.G.
Number of For Low Voltage Service Conductors
115 Volt Service
12V2 Mil O. D.
25 Mil O. D.
31 MU O. D.
16 2
16 3 16 4 16 5 18
18 3 IS 4 18 5
.175 .185 .210 235 .155 .165 .180 .205
.225 .240 .270 .305 .205 .215 .240 -275
.265 .285 .315 .355 .245 .260 .290 .325
Approximate Weights per M Feet (Pounds)
For Low Voltage Service
l2'/j Mil
25 Mil
115 Volt Service
31 Mil
Net Ship. Net Ship. Net Ship.
35 41
43 49 47
53
46 52 56 62 62 68
58 64 69 75 79 85
69 75 84 90 97 106
26 30 34 40 37 43
34 39 43 49 49 55
43 49 53 59 61 67
50 56 64 70 75 81
Finished diameters given above ate average. A tolerance of plus or minus i% is necessary due to variation in process of manufacture.
Standard Shipping Lengths
(Feet)
Coils
500 500 500 500 500 500 500 500
28
RBB 00499
ROCKBESTOS
INDUSTRIAL HEATING CABLES
#
TABLE LH
MAXIMUM LEAD SHEATH TEMP. 350F.
TABLE LHV
MAXIMUM LEAD SHEATH TEMP. ldS'F. U-L. Approved by report for pipe heating applications
SPECIAL ALLOY WIE
FELTED ASSESTOS
LEAD SHEATH
SPECIAL
FELTED
AHOY Wl ASSESTOS
VAINISHED CAA.M/C
lEAO SHEATH
FOR THE CONTROLLED DISTRIBUTION OF MILD HEAT TO PREVENT FREEZING OF WATER, WASTE PIPES, EAVES TROUGHS, DOWN SPOUTS AND VALVES--TO INSURE FLOW OF VISCOUS FLUIDS, OILS, PAINT, CHOCOLATE. ETC.
This Rockbestos heating cable was originally developed to force the growth of early spring plants in hothouses. After its introduction to florists, market gardeners and amateur horticulturists, it found its way into industry as a useful heat source for the distribution of even mild heat. It performed to better advantage and more economically than spot or strip heaters.
Pliable, easily bent and formed, it can be threaded through apertures or made to conform to irregular shaped objects. It is best used wrapped around pipes and cov. ered with a good standard pipe insulation for greatest economy. We can only touch on a few typical applications to which our customers have put this heating cable, but they will give you a good idea of the varied uses to which it has been put.
in many plants the cable is used as a safeguard against frozen water pipes making unnecessary the rearrangement of piping or costly replacement. Waste pipes, eaves troughs and down spouts can also be kept free and clear of ice.
Paint, soap, varnish, ink, chocolate, molasses and sulphur, to name a few, can be kept at fluid temperatures insuring against irregular flow and clogged conveyor pipes.
Wet pipe sprinkler systems located in unheated areas are easily heated and kept at non-freezing temperatures that assure positive operation.
Steel nulls use it around roll-necks to prevent rhe lubricant from congealing and a utilities'engineer wound the cable around the pipes connecting the conservator tank to the main tank of a conservator type transformer, covered it with lagging, and eliminated congealing of oil and freezing of condensate.
The resistance of Rockbestos Industrial Heating Cable is approximately 0.5 ohms per foot. In order to keep the temperature low enough so that the insulation will not be injured, the generally recommended length across 115 volts, is 60 feet. The recommended wattage limit is 7 watts per foot. At 110 volts a 60 ft. length is rated at 400 watts, 6.66 watts per ft. Across 220 volts use a 120 ft. length for the same current value and double the total wattage. Caution-. Do not use Table LH where maximum voltage exceeds 120 volts to ground. Table LHV is suitable for 440 volt service in 240 foot lengths and is U.L. approved by report for pipe heating applications.
When installed permanently, Rockbestos Industrial Heating Cable should be cov ered by some form of heat insulating material for operating economy.
Precise temperature control is established by means of a low piiced thermostat available from a number of manufacturers. We will be glad to refer you to several. The characteristics of this particular heating cable are given simply because it is a standard product and usually available from stock. We are equipped, however, to
make up heating cable characteristics to your specification. Furnish complete details concerning temperature desired, heat dissipation, etc. with inquiry. In applications where this cable is used close to physi cal contact with personnel, the lead sheath should be grounded. Other industrial heating cables are shown on the follow ing page.
Typical installation of industrial beating cable to pipes using insulation and thermostat for precise temper ature control.
TABLE LH and LHV
Table
Approx.
A.W.G. Size
Conductor
Bare Diam. Inches
Approx. Resistance Ohms per Ft.
; 1 ;
Nom. Thickness Insulation
Mils
Lead Sheath Inches
Nominal Finished
Diam. Inches
Approx.
Net Wgt. in Lbs.
per 1000'
Standard Shipping Length
Feet
Shipping Weight in Lbs. per 1000'
LH LHV
19
Nickel
.034
Chrome Iron
19
Nickel
.0*4
Chrome Iron
5052
j 40--Asbestos
5/64
.5052
. 21--Varnished Cambric
5/64
.215 .240
143 60, 120 and 240 ft. lengths and in bulk
160 on Reels
Finished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variation in process of manufacture.
178 on Reels
200 on Reels
29
rBB 00500
ROCKBESTOS SPECIAL INDUSTRIAL HEATING CABLE
TABLE LHT
TABLE LHG
4 *
THESE ROCKBESTOS HEATING CABLES ARE TYPICAL OF THE SPECIAL CONSTRUCTIONS DEVELOPED TO MEET THE SPECIFIC REQUIREMENTS OF OUR CUSTOMERS. THEY ARE SHOWN ONLY TO ILLUSTRATE VARIED CONSTRUCTIONS SUCCESSFULLY DEVELOPED FOR INDUSTRIAL AND PRODUCT USES WHERE THE APPLICATION OF A CONTROLLED HEAT SOURCE WAS NECESSARY.
CONSTRUCTION
1. Special Alloy Wire
2. Felted Asbestos
3. Teflon Tapes
4. Felted Asbestos
5. Lead Sheath
Here is a special lead sheathed heating cable designed to solve a problem in the manufacture of refrigeration units. The problem was to speed the time required in the deicing cycle without appreciable temperature rise in the cold cham ber. The answer here was to design a heating cable suitable for higher voltage operation than our Table LH industrial heating cable shown on page 29. This heating cable con struction has successfully solved this problem. It is suitable for 440 volt service and has a maximum Sheath tempera ture of 350F.
CONSTRUCTION
1. Special Alloy Wires
2. Felted Asbestos
3. Teflon Tapes
4. Felted Asbestos--Silicone Treated
5. Glass Braid--Silicone Treated
Along with the trend toward outdoor power plants came the need for protecting high temperature steam and gage lines from freezing during shutdown periods. Rockbestos Field Engineers called in to study this problem designed this special construction to be applied between the layers of pipe insulation. This provided an ideal solution as the sili cone treated insulation and silicone treated glass braid con struction withstood the high temperatures developed during the normal operation of steam lines and when steam lines were not operating provided a heat source of sufficient temperature to keep the condensate from freezing. This heating cable is rated at 440 volts and has maxi mum operating temperature of 500F.
Rockbestos Heating Cable Designs can be developed :o solve your electrical hearing problems--furnish complete data cov ering temperature desired, heat dissipation, etc. with vour inquiry.
30
RBB 00501
ROCKBE5TOS HEATING CABLE KITS
and THERMOSTATS
ROCKBESTOS HEATING CABLE KITS
for Roof De-icing--Pipe Heating and
Sail Heating Applications FOR THE HOME-ON THE FARM-
(N MOBILE HOME PARKS
Available in 3 Handy Sizes:
60 ft. kit (30 ft. loop)--460 watts
40 ft. kit (20 ft. loop)--260 watts
20 ft. kit (10 fc. loop)---130 watts
Complete instructions with each kit.
operate on 110-120 volts AC or DC
THESE LEAD SHEATHED HEATING CABLES WITH FLEXIBLE NON-HEATING CONNECTOR PERMIT:
Repeated "plug-ins" without damage to the cable
Unlimited uses thru weatherproof construction
Bectec heat conductivity than non-metal sheaths
Easy application to irregular shaped objects
A COMPLETE UNIT ready to plug into any standard 110-120 volt AC or DC outlet
ROOF DE-ICING: This cable serves as a source of mild heat to prevent che formation of ice dams which cause destructive leaks on building or house roofs, including gabled roofs. The current is turned on only when rain or snow is expected and the temperature drops below freezing. The kits come in 20, 40 and 60 ft. lengths (the latter com plete with 8 shingle damps), depending upon the overhang of the eaves. With average house construction one 60 ft. kit will protect 20 running feet of roof. PIPE HEATING: Electric heating cable can easily be applied to water pipes, whether buried in the ground or exposed, to give positive protection against the damage caused by freeze-ups or broken pipes. For maximum coverage of pipe length, the cable should be applied parallel; but where greater protection is needed in low temperatures, the spiral method can be used. When applied this way, the cable will increase the heat applied because of the greater concentration of heat. SOIL HEATING--HOT BEDS and COLD FRAMES: The heating kit serves as a dependable heat source in hotbeds, cold frames and propagating benches to stimulate faster growth for plants and cuttings. Cuttings will root and plants will grow 20 to 30 times faster this clean scientific way. Once the cable is installed, it may be left in place indefinite ly. To insure proper seed germination a thermostat is necessary to accurately control the heat. For this purpose we recommend using Rockbestos Weatherproof Thermostat LT-56 adjustable for temperatures of \0T00F.
ROCKBESTOS WEATHERPROOF THERMOSTAT
LT-56--with Pilot Light Indicator
Automatically Controls Temperatures in Electric Heating Cable Kits for Maximum Economy in Power Consumption
Quickly installed
Automatic protection
Multiple control
PIPE HEATING APPLICATIONS: The thermostat should be mounted directly on the pipe itself, selecting the coldest spot along its length. Five feet of cord leading from the thermostat U provided for connection to a 110-113 volt AC power source. Secure the thermostat to the surface of the pipe with a suitable wire or cord, passing it through the small "ears" on either side of the thermostat. Simply plug the thermostat cord into your power source and plug the heating cable into the back of the thermostat plug When pipe covering is used, extend pipe covering to cover thermostat, leaving only dial exposed for setting. Set the thermostat for the temperature at which heating is to start (approximately 37F. for pipe heating) and thermostat is ready to operate.
HOT BEDS. COLD FRAMES or PROPAGATING BENCH
APPLICATIONS: The thermostat may be mounted within
the frame itself when air temperature control is all that is
requited. When used to control soil temperatures, the
thermostat itself may be buried, allowing the dial and
setting knob to be exposed for final dial setting. The
weather-proof construction provides protection against
moisture encountered in wetting che soil at required in
tervals.
.
SPECIFICATIONS
Ratme Temperature Range
15 amps on 115 volts AC }05F to 100CF maximum
Cord Length
3 feet from outlet to thermostat
Thermostat Construction Weather proof moulded plastic enclosure
Pilot Light
Built into thermostat plug--light glows when heating cable is calling for heat.
CAUTION: Do not install with cable touching itself in any application
RBB 00502
31
STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES
Many companies have requested suggestions for a standard specification to aid them in the ordering of Rockbestos wires and cables. The following specification has been formulated for that purpose and covers Rockbestos A. V. C. and AU-Asbestos constructions described in this catalog.
NOTE: This specification is in accordance with the requirements of the National Electrical Code and the National Electrical Manufacturers Association Standards for Asbestos and Asbestos-Varnished Cambric Insulated Wires and Cables with which all Rockbestos wires and cables of standard construction comply.
I General (a) Purpose: The purpose of this specification is to insure the furnishing of wire and cable of the proper quality, manufactured in accordance with accepted practice.
(b) Scope: This specification covers the construction and test requirements for asbestos-varnished cam bric and all-asbestos insulated wires and cables.
(c) Materials and Workmanship: AU materials and workmanship employed in manufacturing wires and cables to this specification shall be of high quality so as to provide a finished product best suited for the purpose intended.
(d) Applications A.V.C. Insulations. These wires and cables are suitable for operation at the specified voltages in either open or con duit installations in locations where they must operate under both heat and casual moisture con ditions. If wire or cable is to be installed where it may operate under excessive condensation conditions or be submerged, lead sheathed type should be specified. All-Asbestos Insulations. These wires and cables are suitable for operation at the specified voltages as exposed wiring in high temperature locations where little or no moisture is encountered.
II Conductors (a) Solid: Solid conductors shall be either plain, tinned or lead alloy coated copper in accordance with current ASA or ASTM specifications.
(b) Stranded: Stranded conductors shall be bunched, concentric or rope lay as required, The make-up of stranded conductors shall conform to current ASTM specifications. The individual strands shall be as specified for solid conductors in 11(a).
(c) Conductors other than copper shall be specified to meet individual requirements.
III Insulation (a) Asbestos 1. Material: The asbestos insulation shall consist of selected quality, long fibre, chrysotile asbestos commercially free from foreign particles of dirt, cotton seed and metallic oxides. It shall be well carded to prevent lumps and irregularities in the finished wire or cable. The asbestos insulation shall be applied to form a smooth, felted wall of uniform thickness as specified in the tables. The asbestos insulation after extraction of the impregnating compound shall contain not less than 80% by weight of asbestos. The total iron content shall not exceed 4% by weight of the asbestos. 2. Impregnation: The asbestos insulation shall be dried and saturated with a flame and heat resisting compound or a flame, heat and moisture resisting compound as specified. The compound shall consist of suitable high grade ingredients and shall retain its initial qualities during the normal life
0
&
32
RBB 00503
STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C.
AND ALL-ASBESTOS WIRES AND CABLES
9
(b) 1.
2.
of the wire or cable. The compound shall develop no injurious chemical action within itself or with any component parts of the wire or cable. Varnished Cambric Material'. The varnished cambric insulation, when used, shall consist of a high grade varnished doth substantially free from blisters or other imperfections. Application-. The varnished cambric shall be applied with lubricating compound between layers and to the wall thickness specified.
IV Separators Unless otherwise specified, suitable separators may be used over the conductor or between component layers of insulation.
V Braids (a) Asbestos 1. Material: The asbestos yarn shall be of selected quality, long-fibre, chrysotile asbestos contain ing not less than 80% by weight of asbestos. The total iron content shall not exceed 6% by weight of the asbestos. 2. Application-. Asbestos braids shall be applied to conform to current NEMA standards. 3- Finish: Asbestos braid shall be finished with a suitable flame and heat resisting compound or sat urated and finished wdth a flame, heat and moisture resisting compound as specified. (b) Cotton Marker Braids for Multi-Conductor Control Cable Marker braids shall comply with the current requirements of ASA specification for Cotton Braid for Insulated Wire and Cable for General Purposes--Code Braids (commonly known as NEMA Class A braid). (c) Finished Cotton Braid for Outer Covering 1. Finished braid shall comply with the current requirements of ASA specification for Cotton Braid for Insulated Wire and Cable for General Purposes--Standard Braids (commonly known as NE MA Class B braid). 2 This cotton braid shall be finished with a flame and heat resisting compound oc saturated and finished with a flame, heat and moisture resisting compound as specified.
VI Metallic Coverings Coverings such as lead sheath, spiral, basket weave and interlocking armor, when required, shall com ply with current NEMA specifications for metallic coverings.
VII Cabling (a) For cables consisting of more than one conductor (except flat twin cables) the individually insu lated conductors shall be concentrically cabled together. The lay of the conductors in each layer shall not exceed 16 times the pitch diameter of that particular layer. The direction of lay of the conductors in each successive layer shall be reversed. (b) Where circuit identification is required it shall be accomplished by coloring the insulation or by the use of marker braids. (c) When required, fillers shall be used and shall be of jute or asbestos, drv or impregnated with a moisture resisting compound. (d) In cables with coded conductors or w'hen required for manufacturing reasons, a tape shall be ap plied over the cabled conductors.
VIII Tests A. Physical
a 1. Dimensions-. Inspection for dimensional requirements shall consist of four determinations, two to
33
RBB 00504
STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES
be made near each end of the sample of which the average shall comply with the requirements giv en in the tables. The measurements of cable % inch diameter and smaller shall be made with a ratchet micrometer having 14 inch diameter faces. For cable larger than % inch diameter the meas urement shall be made with a circumference tape. Each determination, when made with a micro meter, shall be the average of two measurements made at right angles to each other. 2. Resistance to Flame-. All wires and cables made to this specification shall have fire resisting prop erties so that the test specimens will meet all of the requirements of the Underwriters' Laboratories standard vertical flame test.
B. Electrical 1. Initial Dielectric Strength (a) Single Conductor. Initial dielectric strength tests shall be made on 5-foot lengths of finished wire or cable with the center 3-foot section wrapped with metal foil. Voltages as indicated in the tables shall be applied for 5 minutes on wire or cable rated 600 volts or over, and for 1 minute on wire or cable rated 300 volts. (b) Multi-Conductor-. Initial dielectric strength tests shall be made on full reel lengths of finish ed cable by applying 2^ times rated voltage between each conductor and all others for 5 minutes. Also an initial dielectric strength test shall be made on 5-foot lengths of finished cable, with the center 3-foot section wrapped with metal foil. Voltages as indicated in the tables shall be applied between each conductor and all others and metal foil, and between all conductors and metal foil, for 5 minutes on cable rated 600 volts and over, and for 1 minute on cable rated 300 volts. (c) Metallic Covered Cable-. Initial dielectric strength tests shall be made on full reel lengths of metallic covered cable by applying 21/2 times rated voltage between conductor and covering on
single conductor cable, and between each conductor and other conductors and the metallic covering on multi-conductor cable for a period of 3 minutes. 2. Dielectric Strength After Flame (a) A sample of wire or cable having been previously subjected to the flame test shall be prepar ed with the charred area of sizes No. 6 and larger wrapped in metal foil, and sizes smaller than No. 6 buried in iron filings or fine shot. Test voltages applied for 1 minute shall be as follows:
(1) Asbestos-varnished cambric insulated wires and cables rated at 600 volts or more,
U/2 times rated voltage.
(2) All-Asbestos insulated wires and cables rated at 600 volts, 21/2 times rated voltage. (3) 300 volt rated wires and cables, 1000 volts. 3. Dielectric Strength While Immersed A 5-foot sample of finished wire or cable having flame, heat and moisture resisting finish shall have the center 3-foot section immersed for 1 hour in tap water at room temperature, and while still im mersed shall withstand a dielectric test of 2 times rated voltage applied between conductor and water for 1 minute.
IX Sampling (a) Each of the required tests shall be made on one sample of each size and type of wire or cable from each lot of 10,000 feet or fraction thereof. (b) If a sample fails to meet a prescribed test requirement, two additional samples shall be taken from the same length. If the two additional samples meet the test requirement then the lot shall be accepted. If either of these samples fail the length may be rejected. (c) If any length is rejected for failure to meet a requirement, then a sample shall be taken from each length of the balance of the lot and subjected to the particular test requirement to determine acceptance or rejection of that length.
^ '
34
RBB 00505
SWITCHBOARD WIRES and FULL REEL TESTS
Type
Page
SPECIAL TESTS FOR SWITCHBOARD WIRES
(IPC6A Standard 5-28-357)
(NIMA Standard WC-t-551
Des crip tion
Rated Voltage
Initial Dielectric Tests
Period Test potentials (KV) to
of Test
be applied to sizes
Voltage
18-8 6-2 M/0 Minutes AWG AWG AWG
Standard Flame
Resistance Test
NEMA AVC 6-788
Dielectric Failure Test
NEMA AVC 6-80D1
Leakage Resistance Bend--Dielectric
Test
Test
NEMA AVC 6-80D2 NEMA AVC 6-80DA
AVB
17 Switch- 600
5
3-0 4.0 4.0
board
Wire
AVB
18 Hinge 600
5
3-0 --
--
Cable
TA 19
600
3-0 4.0 5.0
Wire
TA 19 Hinge 600 Cable
5
3.0 4.0 5.0
X Shall withstand not Sample with ends Two 90 bends on a
less than 15,000 volts sealed and foil bands 15" sample in the
conductor to metal 2" apart exposed 16 same plane 2" apart
X
foil on an unbent hours at temperature around mandrel hav sample. Voltage rais- not less than 25C ing same diameter as
ed at uniform rate of in closed chamber sample. No rupture
from 500 to 1000 containing open ves- of covering and shall
X
volts per second.
se! of water. Remov- not break down at
ed and 200 volts D.C. less than 5000 volts
immediately applied conductor to metal
between bands. Leak- foil, filings or shot.
X age resistance shall Voltage raised at uni-
fc* not less than l form rate of from
megohm per inch 500 to 1000 volts
length per inch of per second.
circumference.
Test required only
of sues 8 AWG and
smaller.
Type
AVL AVA AVL
TESTS TO BE MADE ON EACH FULL REEL LENGTH
(1PCIA Standard S-28-357)
(NEMA Standard WC-1-55)
Page
Description
Conductors
Single
Multi-Conductor
Lead Sheath
Rated Voltage
Full Reel Dielectric Test
NEMA AVC 6-80A2
and A4 "Test Voltage (KV)
14 Lighting Wire
X
- X 600
1.5
10-U
Control Cable
-
X -- 600
1.5
15 Power Cable
X
-- X 600
1.5
On Type AVL Single Conductor Cables voltage shill be applied for 5 tninures between conductor and lead sheath. On Type AVL Multi-Conductor Cables voltage shall be applied for J minutes between conductors and between the outet layer of conductors and lead sheath.
On Type AVA Multi-Conductor Cables voltage shall be applied for 5 minutes between conductors.
RBB 00506
3S
TESTS ON SAMPLES OF FINISHED CABLE
(IPCEA STANDARD S-28-357)
Type AVA
AVL AA AIA AF
Pages
12 9 9
13 11 14 15 15
25 22 23 24 27
Description
Lighting Wire 1/C Power Cable
Motor Lead & Apparatus Cable
Control Cable
Lighting Wire
1/C Power Cable
.. .e
>
Apparatus Cable Rheostat Wire Power & Rheostat Cable Apparatus Cable Fixture Wires
(NEMA Standard WC-1-55)
Rated Voltage
600 600 5000
Initial Dielectric Tests--(Kilovolts) * NEMA AVC 6-80A
Standard
l Minute
Flame Dielectric Tests (kv)
Test
Period Minutes
All Sizes
18-16 AWG
l-W/o AWG
250 1000
MCM
Resistance After After
Above
Test
Flame Immersion
1000 NEMA
NEMA
NEMA
MCM AVC 6-78B AVC 6-80B AVC 6-80C
_ 3.0
3.0 _
_
X
0.9
i.:
-- 3.0
3.0 4.0 5.0
X
0.9
1.2
--* -- 12.5 12.5 --
X
7.5
10.0
600 600 600 600 5000 300 600 600 600 300
5
-- 3.0
3.0 4.0 --
5 3.0 -- -- -- --
X X
0.9 0.9
1.2 1.2
Not Requireo--See Test on Full Reel Lengths
1 1.0 -- -- __
5 1.5 -- -- __
5
1.5 -- __
__ __
5 1.5 -- -- __ __
X X X X
1.0 0.9 0.9 0.9
1.2 1.2 1.2
Tests as required by Underwriters' Laboratories Standard for Flexible Cord and Fixture Wir
On single conductor cables volute shell be applied between conductor end metal toil wrap. On multi-conductor cables voltage shall be applied between conductors and between the outer layer of conductors and metal foil. Voltage shall be applied between conductor and metal foil, iron filings or fine shot as required. Voltage shell be applied between conductot and water.
| 36
RBB 00507
ALLOWABLE CURRENT-CARRYING CAPACITIES OF INSULATED COPPER CONDUCTORS IN AMPERES
, (Botvd on Room Ttmptrature of 30C. 86F)
NATIONAL ELECTRICAL CODE--TABLE 310-12 I NATIONAL ELECTRICAL CODE--TABLE 310-13
Net mere than three conductors In Rocowcy of Cable or Direct loriolI Single conductor in tree Air
Size AWG MCM
Rubber Type R Type RW
Rubber TsBr
Type RU
RUH
Type RUVP (14-2)
(14-2)
rhHiw
RH^Iw See note 9
See note 9 Thermo
R&P
plastic Type T
Thermo plastic
Type TV
Paper
Tbcmoplastic Asbestos
TTaTA
Var-Cam Type V Asbestos Var-Cam Type AVB Ml Cable
RHH*
Asbestos Var-Cam
Impreg nated
Asbestos Tir
{14-S>
Asbraos
Type A (Id-*) Type AA
14 12 10
8
6 4 3 2 1
0 00 000 0000
230 300 350 400 500
600 700 750 800 900
1.000 1.250 1.500 1.750 7.000
15 20 30 40
55 70 80 95 110
125 145 165 195
215 240 260 280 320
355 385 400 410 435
455 495 520 545 560
15 20 30 45
65 85 100 115 130
150 175 200 230
255 285 310 335 380
420 460 475 490 520
545 590 625 650 665
25 30 40 50
70 90 105 120 140
155 185 210 235
270 300 325 360 405
455 490 500 515 555
585 645 700 735 775
30 35 45 60
80 105 120 135 160
190 215 245 275
315 345 390 420 470
525 560 580 600
680
785
840
30 40 50 65
85 115 130 145 170
200 230 265 310
335 380 420 450 500
545 600 620 640
730
30 40 55 70
95 120 145 165 190
225 250 285 340
CORRECTION FACTOI FOR ROOM TEMPERATURES OVER 30C. 86F.
Size AWG MCM
Rubber
Type R Type RW
Rubber T#r
Thermo plastic Asbestos
Type RU
RUH
Type TA
Impreg
Type RUW <14-21
r|w
114-2) rh-Kvp
$A
Var-Cam Type V
Asbestos Var-Cam
nated Asbestos
Asbestos
Txr
Type A (14-8)
See note 9 Asbestos
See note 9 iSRr
Var-Cam
ITl
<14- Type AA Type
Thermo
Type AVB
plastic
Type T TypeTW
Thermo plastic
Type THW
MI Cable RHH*
SlowBurning
T=rr
14 12 10
8
6 4 3 2 l
0 00 000 0000
250 300 350 400 500
600 700 750 800 900
1000 1250 1500 1750 2000
20 25 40 55
80 105 120 140 165
195 225 260 300
340 375 420 455 515
575 630 655 680 730
780 890 980 1070 117'
20 25 40 65
95 125 145 170 195
230 265 310 360
405 445 505 545 620
690 755 785 815 870
935 1065 1175 1280 1383
30 40 55 70
100 135 155 180 210
245 285 330 385
425 480 530 575 660
740 815 845 880 940
1000 1130 1260 1370 1470
40 50 65 85
120 160 180 210 245
285 330 385 445
495 555 610 665 765
855 940 960 1020
1165
1450
i 71 3
40 50 70 90
125 170 195 225 265 305 355 410 475 530 590 655 710 815 910 1005 1045 1085
1240
..
45 55 75 100 135 180 210 240 280 325 370 430 510
.. ,
.,
30 40 55 70
100 130 150 175 205
235 275 320 370
410 460 510 555 630
710 780 810 845 905
965 .... 1215 -- 14(73
CORRECTION FACTOR FOR ROOM TEMPERATURES OVER J0C. 86F.
CF
40 104
.82
.88
.90
.94
.95
45 113
.71
.82
.85
.90
.92
50 122
.58
-75
.80
.87
.89
53 131
.41
.67
.74
.83
.86
CF 40 104
45 113 50 122 55 131
.82 .71
.58 .41
i
.88 | .82
.75 .67
.90 .85 .80 .74
.94 .95 .90 .92 .87 .89 .83 .86
60 140 70 158 75 167 80 176
.58 .67 .79 .83 .91 60 140 .35 .52 .71 .76 .87 70 151
.43 .66 .72 .86 75 161 .30 .61 .69 .84 80 176
.58 .67 .79 .83 .91 .35 .52 .71 .76 .87
.43 .66 .72 .86 .30 .61 .69 .84
90 194 100 212 120 248 140 284
.50 .61
.80 90 194
.51 .77 100 212
.69 120 24*
.59 140 28-i
.50 .61 .51
.80 .77
.69 39
The current-carrying capacities (or Type RHH conductors for sizes AWO 14, 12 and 10 shall be the same as designated for Type RH conductors in this Table.
0
NATIONAL ELECTRICAL CODE (NOTES TO TABLES
1. Ezplonetien el Tobies, for eipioaotie* of Type letters, end ter recognised tire el tondutfers for the toriovt cendwcter intuleiieni, tee Sectient 310-2 end
310-3. for intielle'iee reevirementi. tee Section 310-1 through 310-7. end rhe
various Articles of this Cede, for flexible cords see Tables 400-9 end 400-11. 2. Application of Tables, for epee wiring on insulators and for conceded
knob-end-lube work, the allowable current-carrying coeeciliei of Tablet 310-13 and 310-15 shell be used, for ell Other recognised wiring methods, the allow able current-carrying capacities el Tables 31012 end 3)0-14 shall be used, unless otherwise provided in this Cede. 3. Aluminum Conductors, for aluminum conductors, rhe allowable current
carrying ceoocittet shell be in accordance with Tables 3)0-14 and 310-15. 4. bare Conductors. Where bore conductors d'e used with insulated conduc tors. their allowable currenl-cerrying capacity shell ba limited to that per mitted far the insulated conductors el the seme site. 5. Type Ml Cable. The temperature limitation on which the current.carrying
capacities el Type Ml cable ere based, is determined by the insulating materials used in the end seel. Termination fittings Incorporating vmmpregnated organic insulating materials are limited to 8S*C. eeeratien.
6. Ultimate Insulation Temperature, in no cate shall conductors be associ ated together in such e woy with respect to the kind el circuit, the wiring method employed, or Ihe number el conductors, thgt the limiting temperature of the conductors will be exceeded.
7. Use of Conductors With Higher Operating Temperatures. Where the room temperature is within 10 degrees C .el ihe maximum ollewoble operating ternperalure of the Insulation, it is desirable to use on insulation with e higher maximum allowable operating temperature; although insulation can be used
In e room temperature approaching its maximum allowable operating tempera ture limit if Ihe current is reduced in accordance witn rhe Correction Factors far diHereni roam temperatures.
I. hSere Than Three Conductors in a gateway an Cable. Tables 310-12 and 310-14 give Ihe allowable current-carrying capacities let net mere then three conductors in a raceway or cable. Where the number el conductors in e
310-12 and 310-13)
raceway or cable exceed* three. toe ollowobto <vrf#n*carrying cabde'y
tech <ondv<ror MtoM bo reduced o thdvn in too following Table*
Number of
For Coni of Volvo* In
,
of
4 to d
80
7 to 24
... 70
25 to 42
60
45 ond obdv*
50
Except5on--When conductor* of different mtem*. o provided to $eci>0 200-3.
oro inttolled in o common rocewov too derating factor* shown above apply to
the nvmbor of F#w#r ond lighting J Article* 210, 215, 220 and 230) con*
dvetors only.
9. Where Typo IH-EW rubber tosuloted wiro it uiod in wo' loco'toM 'ho
oliowdblo curroni'carrytop cQOecilie* then bo tod' of Column 2 * lob'ot
3)0*12 torevgh 310-15- Whoro utod m dry leco'ient the allowable current
carrying copoc'rie* thdll bo thot of Column 3 to Tebloi 3)0*12 through 310*15.
10. OvorcwfTOAf Protection. Whoro too srendord relines ond *#ffing* of
ovorcurroot device* do net correspond with the refines end letting* Oltowod
for conductors, too not' hiehor tiondord rating end sotting moy be utod.
11. Neutral Conductor. A nou'rel conductor which corries only too enbel*
onced currenr from otoor conductors, es <n toe cost of normolly balanced
circuits of tore# or more conductors, shell not bo counted m determining
current-carrying coeaci'ie* es provided for in Note 8.
In o 3*wre circuit consisting of two photo wires end the nevtrgl of a 4*wiro,
3*photo system, o common conductor corries approximately the semo current
os the other conductor* end is not therefor# considered es o neutral conductor.
12. Voltage Drop. The dltowoble current*earning cooocitiet in Tobies 310*12
through 310*15 or# based on temperature elone end do nor toko voltage drop
imp considerotien.
13. Deterioration of Insulation. It should be noted thot even toe best
gredes of rubber insulation win detorioroio in lime, to r*entuolly wilt need
to be reploced.
37
RBB 00508
CONDUIT SIZE TABLES
Percent Occupancy Allowed by NEC. (For Rewiring see page 39)
f)
i.
4 TABLE C 600 VOLT A.V.C. LIGHTING WIRE
i
Cable
Number of Cables in Conduit
Size
Inches
1
2
3
4
$
6
7i8
9
Minimum Size of Conduit
18 .220 16 .235 14 .245
12 .265
1/2 1/2 1/2 3/4 3/4 1
1/2 1/2 3/4 3/4 1
1
1/2 5/4 3/4 3/4 1
1
1/2 3/4 3/4 1 1 1
I
l i l 1/4
11 ) 1 1 -4 | ] 1 '4 1 i 14
11 1 14
1 14 1 1 '4
10 .285
1/2 3/4 3/4 1
1 i 1 1/4 i i 1/4 1 1 1 '4 1 1 1 4
8 .310 6 .385
t/2 3/4 3/4 1 1/2 1 1 1 1/4
l 1/4 1 1/4
t 1 1/4 1 1/2
' i 1/4 i 1/2
, 1 1 '2 12
1 i;
5 .405
4 .425 .450 .480
I .540
1/2 1
1 1/4
V 1/4
1 1/2
1 1/2
2
2
*2
y y1/2 t 1/4 1 1/4 1 1/4 1 1/2
> '
y1/2
1 1/4
l 1/4
l 1/2
l 1/2
2
2 .2
i ;
3/4
1 1/4
1 1/4
l 1/2
*
y3/4 1 1/4 1 1/2 2
2 2 1/2
1/2
. ,
2 12 1. 2
*> 3
y1/0 .575
3/4 1 1/2 1 1/2 2
2/0 .615 1
l 1/2
*>
*> 2 1/2
2 1/2 2 1/2
> 1/2 ;
|5 13
3
2VO .660 1
>
y
2 1/2
2 1/2
3
> '3
3r
4/0 .710 1
2 2 1/2
.3
! 5 l2
>i:
TABLE E 600 VOLT A.V.C. POWER CABLE
Cable Size
Cable Inches
11
2i
Number of Cables in Conduit
3I 4i
51 6j
"
89
Minimum Size of Conduit
IS .235
1/2
1/2
3/4
3/4
1
1
I 14
1 14
4 16 .250
1/2 3/4
3/4
54
1
1
!
1 14
1 14
14
.265
1/2
3/4
3/4
1
1
V
\ 1'4
1 1 -'4
1 14
12
.285
1/2
3/4
3/4
1
1
1 1/4
i 1/4
I 1/4
1 14
10 310
1/2
3/4
3/4
1
! 1 -'4
: i.'4
i 1 '4
1 1/2
I 12
s ,t5() t/2 1
1
1 1 '4
1 1.4
1 !4
t 1. 2
1 1 '2
y<!
.405
1/2
1
1 1/4
1 1/4
1 1,2
1 12
**
**
2 2 y.430
1/2
1 1/4
1 1/4
1 1'1
l 1/2
2
y4
455
3/4
1 1/4
l 1/4
1 1.'2
l 1-2
-
*
2i:
>
480
3/4.
1 1/4
1 1/4
l 1/2
**
*>
2 1 '2
2 12
2
515
3/4
l 1/4
1 1/4
y
y
y
1 '2
2 1.2
2 12
1 25S5
3/4
1/2
1 1/2
y
2 1/2
2 1.2
J
3
21 0
.625
1
1 1/2
2
-
2 2 1/2 ;
3
2.-0
6"0
1
*2
y 1/2
2 '2
; 3 3 l2
yy 2i 3 0 40
"20 -so
1 1 1/4
1/2
3
3
;
3 1 '2
3l2
2 1/2
3
3
3 1 '2
3 1/2
4
2250
:
S,5
1 1/4
2 1/2
1/2
3
3 1-2
5 K2
4
4
412
too
oto
1 1/4
*> 1/2
2 1/2
3 '2
4
4
4 1/2
4 :;
350
.985
1 1/4
3
3
1/2
3 1/2
4
4 1/2
4 i :
5
1U0
;
1.030
1 1/2
3
3
3 lO
4
4
4 l '2
3
5
450 sou 550 001)
650 700 "50 .S(ll)
S50 `>1)0 >5,1 1000
1 2'0 1 too 1 "5(1 2000
.
1.0-5 1 115 1 165 1 205
1 240 i ;-5 1 510 1 545
1 3-s 1 104 1 454 l 465
1 6 10 I "64 1 SNtl 1 '>S4
1 1/2
y t 1/2 1 1/2 y22
2
2 2 2 1 '2 2
_3
5 3
3 1/2 3 \/2 3 1/2 3 1/2
3 1/2 4 4 4
-1 1'2 4 1/2 4 4
3 3
1/2 ) 1/2
3 1/2 3 1/2 3 t/2 3 1/2
4 4 4 4
4 1/2 5 5 6
3 i.': 1 '2
4 1
4 4 1 '2 4 1 -2 41
4 t '2 41 s
5
6 6 6
--
4 4 4 1. 2 4 '2
4 '2 4 -2 5 5
5 5 6 6
6
_
--
4 1 '2 4 '2 s 5
5 4 6 6
6 6 6 6
--
4 1 -'2 4 5 <
6 6 6
6 (4 6
5 5 6
6 6 6 6
_
-- --
--
_
--
--
6 6 (> 6
6 6
--
--
-- -- --
--
_
-- --
--
38
RBB00509
CONDUIT SIZE TABLES
TABLE EL
Cable Size
Oble Diam. Inches
18 16 14 12
10 8 6 5
4 3 2 1
1/0 2/0 3/0 4/0
250 300 350 400
450 500 550 600
650 700 750 800
850 900 950 1000
1250 1500 1750 2000
.270 .285 .300 .320
.340 .370 .420 .440
.470 .495 .560 .620
.660 .705 .760 .815
.945 1.000 1.050 1.095
1.140 1.180 1.265 1.300
1.340 1.375 1.405 1.440
1.470 1.500 1.530 1.560
1.770 1.890 2.005 2.110
LEAD SHEATHED
A.V.C. POWER CARLE TABLE CL
LEAD SHEATHED A.V.C. LIGHTING WIRE
No. Cables in Conduit
234
Minimum Size of Conduit
1/2 1/2 1/2 1/2
1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 1 1 1/4
1 1/4 1 1/4 1 1/2 1 1/2 l 1/2 1 1/2 2 2
2 2 2
*>
2 1/2 2 1/2
3 3
3/4 3/4 3/4 1
1 l 1 1/4 1 1/4
l 1/4 1 1/4 1 1/2 1 1/2
2 >
2 2 1/2
2 1/2 3 3 3
3 3 3 1/2 3 1/2
3 1/2 3 1/2 4
4 4 4 4 4 1/2
5 5 6 6
3/4 3/4 3/4 1
1 l 1 1/4 1 1/4
1 1/4 1 1/4 1 1/2 2 2
2 2 1/2 2 1/2
3 3 3 3
3 1/2 3 1/2 3 1/2 4
4 4 4 4
4 4 1/2 4 1/2 4 1/2
5 6 6 6
1 1 1 1
1 1/4 1 1/4 1 1/4 1 1/2
1 1/2 1 1/2 2 2
2 1/2 2 1/2 2 1/2 3
3 3 1/2 3 1/2 4
4 4 4 1/2 4 1/2
4 1/2 4 1/2 5 5
5 5 5 6
6
--
able Size
18 16 14 12 10 8 6
5 4 3 2 1 1/0 2/0 3/0 4/0
Cable Diam. Inches
.245 .255 .270 .285 .310 .335 .400 .420 .440 .465 .495 .575 .610 .650 .695 .745
No. ables in Conduit
234 Minimum Size of Conduit
1/2 1/2 1/2 1/2
1/2 1/2 1/2 1/2
1/2 3/4 3/4 3/4
1 1 1 1
3/4 3/4 3/4 3/4
3/4 1 1 1 1/4
1 1/4
1 1/4 l 1/4 1 1/2
1 1/2 2 2 2
3/4 3/4 3/4 3/4
1 1 1 1/4 1 1/4
1 1/4
1 1/4 1 1/4 I 1/2
2 2 2 2
3/4 I 1 1
l 1 1/4 1 1/4 1 1/4
l 1/2 l 1/2 1 1/2 2
2 2 1/2 2 1/2 2 1/2
COMBINATIONS OF CONDUCTORS
TABLE NO. 3 NEC P*r Cent Area of Conduit or Tubing
Number of Conductors
Over 44
Conductors (not lead covered).... 53 31 43 40 40
Lead-Covered conductors ............ 55 30 40 38 35
For rewiring existing raceways for
increased load where it is im
practicable to increase the size
of the raceway due to structural
conditions .................................... 60
40
50
50
50
MAXIMUM CABLE DIAMETERS FOR PERMISSIBLE CONDUIT FILL
Size Inches
1/2 3/4 1 1/4 1 1/2 2 1/2
3 1/2 4
5 6
NOT LEAD COVERED
No. Cables per Conduit
1 j y|3
.450 .598
1.000
i
1 |
.243 -323 .412
.545
i '.
.234 Ml
-523
1.170 1.505 1.795 2.232
| .634 1 .814 ; .9-2 :
i 1.206 |
61(7 .785 .935
1.161
2.585 2.930 3.281
i 1 398 . 1 345 ! 1.585 \ 1 524 j 1.776 : 1*06
3.675
1.9S* ! 1 910
4.415 j 2.390 j 2.296
4
.195 .260 .331 .437
.510 .654 .781 .969
1.123 1.273 1.425
1.596 1.920
LEAD COVERED No. Cables per Conduit l 23
4
.458 .609 .776 1.025
1.195 1.535 1.832 2.275
2.635 2.985 3-345
3.745 4.500
.239 .318 .405 .535
.624 .801 .956 1.187
1.375 1.559 1.745
1.955 2.350
.225 .300 .382 .505
.588 .755 .902 1.120
1.295 1.470 1.646
1.843 2.215
.190 .253 322 .426
.496 .637 .761 .945
1.094 1.240 1.389
1.555 1.870
REWIRING
No. Cables per Conduit 1 23 4
.479 .636 .811 1.070
1.248 1.602 1.913 2.375
2.750 3.118' 3.490
3.910 4.700
.276 .367 .468 .618
.721 .925 1.105 1.371
1.588 1.800 2.015
2.257 2.715
.252 335 .427 .564
.658 .844 1.008 1.251
1.450 1.643 1.840
2.060 2.480
.218 .290 .370 .489
.570 .731 .873 1.084
1.255 1.423 1.593
1.784 2.145
RBB 00510
39
CURRENT RATING CORRECTION FACTORS FOR VARIOUS GROUPINGS OF CABLES OR CONDUITS
{I. P. C. E. A. PUBLICATION No. P-29-2261
.
.1 These tables list correction factors for the I specific groupings of conduits and cables and
are applied to current ratings determined by the NEC Tables on page 37.
Simply multiply the current rating by the correction factors for the specific groupings of conduits or cables.
Number of Conduits Horizontally
Vertically
2 3 4 5 6
For Cables in Conduit--Values of K 12 34
1.00 0.92 0.85 0.82 0.80 0.79
0.94 0 87 0.81 0.78 0 76 0 "5
0.91 0.84 0.78 0.74 0.72 O.'l
0.88 0.81 0.76 0.73 0.71 0.70
5
0.87 0.80 0.75 0.72 0.70 0.69
6
0.86 0.79 0.74 0.72 0.70 0.68
Number of Cables Horizontally
Vertically 1 2
3 4 5 6
For Cables in Air--Values of K 1 234
1.00 0.89 0.80 0.77 0.75 0.74
0.93 0.S3 0.~6 0.72 0.70 0.69
0.87 0.79 0.72 0.68 0.66 0.64
0.84 0.76 0.70 0.67 0.65 0.63
5
0.83 0.75 0.69 0.66 0.6-1 0.62
6
0.82 0.74 0.68 0.65 0.63 0.61
Note--Th* correction (actors apply only when the spicing bcmcen cible or conduit turfices is not greater thin cable oi conduit diameter, or less than one-quarter of cable or conduit diameter.
Minimum Bending Radii for Rockbestos Wires and Cables
This catalog shows many "standard" and "special" Rockbestos wires and cables and be cause both construction and diameter determine the Bending Radius, information on any specific wire or cable will be furnished on request.
40
RBB 00511
TERMINAL and JOINT INSULATION FOR A.V.C. CABLE
In general, no special precautions are necessary in the insulating and waterproofing of terminals or joints in A.V.C. cable runs. This is because of the additional ther mal capacity of thermal ends and joints, plus the fact that in general such terminal ends or joints are in cooler ambient locations than the main run of the cable. In this type of location it is common practice to use rubber tape and friction tape as a means of insulation. For large sizes of A.V.C. cable where a splice is neces sary, it is advisable to build up the joint with layers of varnished cambric tapes prior to the application of the rubber and friction tapes. In wet locations where lead covered A.V.C. cable is used, the same practice is used except that the friction tape is
treated with a glyptal varnish or Irvington oil stop. The illustration below shows a recommendation for such a cable splice. In all high voltage, i.e. over 600 volts, all terminal ends and joints should be insulated with varnished cambric tape before applying the rubber or friction tapes. The friction tape should be treated with either glyptal varnish or Irvington oil stop. Where it is necessary either to terminate or make a jomt in a high ambient temperature zone, we recommend that the joint or terminal end be insulated with layers of var nished cambric tapes wrapped with asbestos listing. List ing can be coated with wax or covered overall with friction tape.
SUGGESTED METHOD OF SPLICING AVA OR AVL CABLE
1. Prepare cable ends and joint with standard soldered or mechanical connector. 2. Paint connection and adjacent insulation with compound such as glyptal varnish or
Irvington Oil Stop. 3. Apply layers of varnished cambric tape with glyptal varnish or Irvington Oil Stop
between layers to fill up space even with braid or lead sheath. 4. Apply two layers of rubber tape, and then two more layers of friction tape with
glyptal varnish or Irvington Oil Stop between all layers and over surface. Extend rubber and friction tape over at least two inches of the cable sheath or braid which previously had been painted. 3. In case of lead sheathed cable where joint will be in wet location, a lead sheath and wiped joint may be used.
%
RBB 00512
BARE COPPER WIRE DATA
ALL DATA TO ASTM B-258 RESISTANCE (BUREAU OF STANDARDS)
f\
Size AWG
Dim. laches
Circular Mils
LBS/1000'
FT/LB
OHMS/1000' 1 20C (68F) :
Sire AWG
4/0
.460
211.600
640.5
3/0
.410
167.800
507.9
2/0
-365
133.100
402.8
I/O
.325
105.600
319.5
1.561 1.968 2.482 3.130
.04901 .06180
.07793 .09827
:
VO 3- 0
1 '0
1
.289
83.690
253.3
2
.258
66.360
200.9
3
.229
52.620
. 159.3
4
.204
41.740
126.4
3.947 4.977
6.276 7.914
.1239 .1563 .1970 .2485
1
3 4
5
.182
33.090
100.2
6
.162
26.240
79.46
7
.144
20.820
63.02
8
.128
14.510
49.98
9.980 12.58 15.87 20.01
3133 3951 .4982 .6282
6 8
9
.114
13.090
39.63
10
.102 10.380
31.43
11 .091 8.230 24.92
12 .081 6.530 19.7-
25.23 31.82 40.12 50.59
792! 9989 1.260 1.588
9 12
13
.072
5.180
15.68
14
.064
4.110
12.43
63.80 80.44
2.003 2.525
15
.057
3.260
9.858
101.4
3184
15
16
.051 2.580
7.818
127.9
4.016
16
17
.045
2.050
6.200
161.3
5 064
* 18 19
.040 .036
1.620 1.290
4.917 3.899
203.4 256.5
6.385 8.051
18
20
.032 1.020
3.092
323.4
10.15
20
21 22
.028
812
2.452
407.8
12.80
:
.025
640
1.945
514.2
16.14
;
23
.0226
511
1.542
648.4
20 36
:
.020
404
1.223
817.7
25 67
24
25
28 29 30 31 , 32
.0179 .0159 .0142 .0126
.0113 .010 .0089 .0080
320 253 202 159
128 too >9.2 64.0
,
.9699 -7692 .6100 .4837
.3836 .3042 .2413 .1913
1031. 1300. 1639. 2067
2607. 3287. 4145. 5227.
32.37 40.81 51.47 64 90
81 83 103.2 130.1 164.1
` '
26
2S 29 30 31 52
33 34
36 i 37 ! 38 ! 39 ;
.OO't .0063 .0056 00i0
.004 ' .0040
.0035 .0051
j
1 j
504 39.7 31 4 25 0
20 2 16.0 12.2 9.61
' ' '
.1517 .1203 .09542 .07568
.06001 04759 .03774 .02993
6591. 8310. 10480. 13210
16660 21010. 26500. 33410.
206.9 260 9 329.0 414.8
525-1 659.6 S31.8 1049.
i '
34 35 56
37 38 39 40
42
RBB 00513
RETURNABLE REEL DATA
a
REEL DIMENSIONS -- INCHES
Flange (A) ..........................................................................................
Traverse (T) ........................................................................................ Drum (8) ............................................................................................ Max. Width (W) ...............................................................................
Vol. Cu. Ft.............................................................................................
Approx. ,l 1-- All Wood ............................................................
Weight UM-
Wood-Steel Drum .............................................
42 12 24
18% 19.1
130 185
48 15 24 21% 29.0
184
48 24 24 30% 40.6
250 275
60 32 32 40% 84.4
500 500
66 32 32 40% 102
550
: ; i ] :
'
66 36 40 45 114
650 650
72 j 36 ; 40 . 45 135
790 790
-2
36 4S 45 135
820 820
Cable Diam., laches
.500 .520 .540 .360 380
.400 .420 .440
.460 .480
.500 .550 .600 .650 .700
.750 .800 .850
0 .900 -950
1.00 1.05 1.10 1.15
1.20 1.25 1-30
MAXIMUM CAPACITY FOR SOLID COVDt.'CTOR
OR LEADED CABLE
1.35 1.40 1.45 1.50
1.55
1.60 1.65 1.70 1.75
NOTES:
1. Clearance (X) meets IPCEA Standards on -300" diameter and over.
2. Use max. dia. of cable to determine reel size.
3- All capacities shown in this table meet a recommended drum diameter (B) equal to 14 times the cable diameter. For all leaded and solid conductor AVA cables, the recommended drum diameters (B) are 18 times the cable diameter--see above solid line.
4. All reels with leaded cables (30" flange and larger) to be wood lagged. Lagging adds the following to reel weight:
Size Reel
Wgt. of
Laggiag Lbs.
Size Reel
Wgt. of Laggiog
Lbs.
8080 7190 6300 5670 4990
4530 4100 3710 3460 3170
2890 2410 1980 1680 1450
1300 1120 976 891 777
716 629 582 543
Recommended Maximum Capacity--Feet Pei Reel
10714 9938
8883 8129 7447 6682 6133
5670 4691 3910 3360 2840
2490 2170 1910 1760 1560
1380 1280 1140 1060
9070 7500 6260 5380 4540
3980 3470 3060 2810 2490
2210 2050 1820 1700
9630
8490 7250 6440 5730 5090
4730 4224 3770 3540
9810 8300 7460 6700
6000 5360 5190 4630
X -- Clearance between top layer of cable and flange edge.
9590 7800 6940 6130
5680 5100 4560 4230
8370
7540 6790 6310 5710
8980 7950 7220 6420
5740 5270 4730 4380
477 946 1510 445 888 1420 418 841 1350
394 747 1190 345 706 1130 326 672 1070 308 594 949 292 565 905
278 541 864 262 516 825 231 456 728
Cable Diam.. laches
1.80 .................
1.85 .................
1.90 .................
2.00 2.10
....................
2.20 ..........
2.30 2.40 2.50 2.60
2.70 2.80 2.90 3.00
3180 2990 2690
2540 2400 2160 2050 1950
1760 1670 1600 1530
1370 1320 1270 1090 1010 938
4110 3990 3530
3440 3020 2950 2570 2510
2460 2120 2080 2040
1740 1710 1680 1390 1350 1100
3810 3550 3200
3020 2840 2570 2420 2300
2190 1970 1880 1800
1710 1550 1480 1360 1260 1090
1010 941 880 762
714 671
5170 4850 4400
4150 3770 3580 3400 3070
2930 2650 2540 2430
2360 2110 2030 1870 1630 1520
1420 1230 1160 1090
1030 894
3950 3670 3440
3120 2920 2750 2490 2360
2230 2120 1920 1830
1740 1660 1590 1380 1260 1170
1080 941 874 818
764 718 625 588
42x12 48x15 48x24
80 90
101
60x32 66x32 66x36 72x36
210
240 270 300
RBB 00514