Document 6wDz5KmK8qp31oj8RpqdJ2Mk3

ROCKBESTOS WIRE & CABLE ASBESTOS Insulated Wire &, Cable ROCKBESTOS WIRE & CABLE CO. ! DIVISION OF CEBRO CORPORATION NEW HAVEN 4 - CONNECTION RBB 00470 A. FIU No. 31-C-472 a lio N o. J 1 -C -4 7 * < ROCKBESTOS WIRE & CABLE CO. Division of Cerro Corporation Main Office and Works NICOU AND CANNER STS., NEW HAVEN 4, CONN., U. S. A. o O i. I. A. FIU No. 31-C -672 a lio No. 31-C-67R 5M 10-62 PRINTED IN U.S.A. RBB 00471 ROCKBESTOS is the name -for a wide line of wires, cables and cords, including more than 125 different standard constructions, which have been designed and developed to give long and depend able service under severe operating conditions. Early in 1918 a small group of Rockbestos Elec trical Engineers and Chemists perfected a method of applying asbestos to wires and cables as a heat resisting electrical insulation. This first step result ed in the production of wire that industry and elec trical engineers had been looking for. Here was an insulated conductor resistant to high tempera tures, aging, corrosive fumes, grease, oil and flame. Success from the start--and just the beginning for this company which was later to distinguish itself to be the only company in industry devoted ex clusively to the manufacture of permanently insu lated wires and cables. Rockbestos grew along with the then rapidly growing electrical industry, solv ing its electrical insulation problems as they became apparent with this unique mineral, ASBESTOS. Other materials are often combined with asbes tos, i.e. Varnished cambric, Synthetics, DuPont "Teflon'' Tettafiuoroethylene resin, cotton, rayon, nylon and glass, to provide special characteristics. Two broad lines of permanently insulated wires, cables and cords--Rockbestos A.V.C. asbestos-var nished cambric insulated (N.E.C. Types AVA and AVB) and Rockbestos ALL-Asbestos (N-E.C. Types A, AA, AI, AIA and AF)--have been de veloped for innumerable industrial applications. Rockbestos engineering and research are constantly abreast of electrical problems in both science and industry, providing answers through the develop ment of trouble-free, ageless electrical insulations designed for each specific application. May we offer you our research facilities for the development of special wires designed to meet any unusual re quirements. RBB 00472 f This is the Rockbestos Handbook and Catalog No. 10-H, which illustrates and describes wires and cables insulated with Asbestos Varnished Cambric> and All Asbestos insula tions for use where wiring in electrical products or in the power, control and lighting circuits of industry is exposed to heat, corrosive fumes, grease, oil or fire hazard. Also contained in this catalog are Rockbestos special con structions developed for special and specific applications. All data subject to change without notice. ROCKBESTOS WIRE & CABLE CO. DIVISION Of CERRO CORPORATION MAIN OFFICE AND FACTORY: Nicoll and Canner Streels, New Haven, Conn. s RBB 00473 Table A A-300 B BH BS Page 600 Volt Rheostat Wire............................................................. 300 Volt Rheostat Wire, High Temperature........................ 600 Volt Switchboard Wire (Solid) ....................................... 600 Volt Switchboard Hinge Cable....................................... 600 Volt Switchboard Wire (Stranded).................................. 20 24 17 18 17 C CL E EL EMA 600 Volt Lighting Wire (Solid) ............................................. 600 Volt Lighting Wire--Lead Sheathed.............................. 600 Volt Power Cable--Single Conductor.............................. 600 Volt Power Cable---Lead Sheath, Single Conductor...... 1000 Volt Lead Wire................................................................... 12 14 9 15 27 FS FSB H HL L 300 Volt Fixture Wire............................................................... 300 Volt Fixture Wire (Braided) ....................................... 5000 Volt Power Cable, Single Conductor................... 5000 Volt Power Cable, Lead Sheath, Single Conductor 600 Volt Motor Lead and Apparatus Cable.......................... 25 25 9 15 13 LH-LHV LHG-LHT MD ML Industrial Heating Cable.................... .. Special Industrial Heating Cable .......... Heating Cable Kits and Thermostat . ... 600 Volt Control Cable, (AWG No. 12-19/25) .................. 600 Volt Mining Cable................................................................ 29 30 31 11 26 MT R R-300 RF RF-300 600 VoltControl Cable (AWG No. 9-19/22)...................... 600 VoltPower and Rheostat Cable ....................................... 300 VoltRheostat Wire, (Stranded) ....................................... 600 VoltApparatus Cable, Flexible........................................ 300 Volt Rheostat Wire (Flexible Stranded) ........................ 11 21 24 22 24 TC-TCC-TCS W XB-XBS-XBH ZM Thermostat Control Wire............................................................ 300 Volt Apparatus Cable, Extra Flexible.............................. 600 Volt Switchboard Wttes, Type TA.................................. 1000 Volt Hookup Wire............................................................. 28 23 19 27 RBB 00474 3 ASBESTOS OUR BASIC RAW MATERIAL In entering upon a description of Rockbestos wires and cables, a brief outline of the characteristics of asbestos, the chief material used in their insulation, is a logical beginning. Asbestos is a mineral, consequently inorganic in its na ture, and in this principal feature different from all other types of material in use for insulating wires and cables. Asbestos fibres are solid, that is to say they have no cap illary opening through their center like cotton, wool or other organic fibres. Because of this fact, there is no ten dency for individual asbestos fibres to act as capillaries if their ends are exposed, and it only becomes necessary to fill the voids of interstices between the fibres to pro duce a relatively impervious layer. Asbestos has demonstrated its ability to withstand time without the deterioration that occurs in other forms of electrical insulating materials such as rubber and the gen eral class of organic fibres. Furthermore, it will not rot or carbonize under any conditions. It may be faicly stated indeed that asbestos is ageless, and time, as every engi neer well knows, is a much more exacting test of a material than almost any laboratory accelerated life test which can be made. During the centuries since the as bestos was formed, it has been exposed to high earth temperatures and, as earth cooled, to moisture and the wide variety of earth acids and alkalis, all with no apparent change in any of its properties. We have investigated the world's sources of asbestos to find and secure the softest, silkiest, purest, long fibred asbestos... and we find it in certain deposits of Chrysotile (Serpentine Group)--the aristocrat of the asbestos family. Chrysotile is a hydrated magnesium silicate which occurs in crystalline form in veins or striations in the mother rock and is widely distributed. Each crystal is a "fibre", square in cross section, haviog a diameter of about 1/500, 000 inch and a length equal to the width of the vein. There are a number of sources of Chrysotile fibre, the principal ones being Rhodesia, Canada, Russia, Arizona and Australia. The largest deposits are in Rhodesia and Canada. Asbestos retains its strength and fibrous form under all conditions except extremely high temperatures. Chryso tile asbestos in crude (unopened form) begins to lose some of its water crystallization at about 450C and is almost completely dehydrated at 850C. It fuses at about 1500C. When applied to wires or cables in felted form, its low heat conductivity enables it to withstand melting the copper conductor by passage of high currents without material loss of its mechanical strength. Tests of fabrics woven of Chrysotile asbestos show that after three hours at 500C they still have their original tensile strength. Asbestos, after it is mined, is broken up, fiberized and cleaned. It is then combed and carded into soft, fluffy roving. In this form it is applied to the conductor, impregnated with neutral insulating compounds, and compressed into the felted wall which is Rockbestos insulation that is not only fireproof but practically impervious to the destruc tion normally caused by heat and moisture, oil, grease, corrosive fumes or age. What a material to use where endurance and resistance to deterioration are so important! Hard as a rock in the vein, asbestos is soft as silk when fiberized. Each silky fiber is a crystal !/500,000th of an inch in diameter. A m'tUion-year-old handful! This asbestos has been completely fiberized and prepared and is now ready to be carded into roving. RBB 00475 WHY ROCKBESTOS A.V.C. WAS DEVELOPED Since die early days of electrified industry, there has been a definite need for an electrical conductor insulation which would operate dependably in elevated ambient temperatures. High ambient temperatures were a prob lem then as they are today, and the performance of or* dinary wires and cables at that time was restricted by the very nature of the materials used. Rubber, for instance, while known to be high in moisture resistance, was af fected by high temperatures which caused it to become dry and porous limiting its length of effective service. The life of straight varnished cambric insulations too was seriously affected by high ambient temperatureswhich tended to cause deterioration of the tapes. Early asbestos insulations proved unsatisfactory because they consisted only of a series of asbestos braids filled with paint or other compound. Recognizing that high temperatures and moisture were the major threats to the life of insulations, Rodcbestos Engineers designed and developed their A.V.C construc tion. This A.V.C. construction used as a basis dense felt ed walls of thoroughly impregnated asbestos to form a continuous insulation which would permanently resist heat, flame and moisture. High dielectric varnished cam bric tapes were added as an insert between the felted as bestos to give added dielectric strength and moisture resistance. In this combination the felted asbestos also provided protection for the Varnished Cambric tapes against mechanical damage, deterioration from oxida tion and prevents the formation of a continuous carbon path from conductor to ground. This basic construction was covered overall with either impregnated asbestos or flameproof cotton braids. This new Rodcbestos A.V.C construction was designed primarily to safely and depen dably carry electrical loads in high ambient locations and to withstand additional operating hazards such as attacks of chemicals, oils, grease and fumes. Here was an insu lation designed to give a long life of dependable oper ation under severest conditions. Since the introduction of Rockbestos A.V.C. wires and cables in 1927, many millions of feet have been installed throughout the world under normal and abnormal oper ating conditions. These installations have covered a wide range of high temperatures and moisture conditions in practically every known industry. Rockbestos Field Engi neers have constantly checked many of these installations in various industries since 1927 to check field conditions against long time tests run by our Research Laboratory to confirm the ability of Rockbestos A.V.C. to meet un usual service conditions. Because of their successful oper ation, these asbestos-varnished cambric wires and cables were included in the National Electrical Code in the 1937 Edition and designated as N.E.C Types AVA, AVL and AVB. The trade name "A.V.C" as registered by Rockbestos and used commercially is synonymous with National Electrical Code Types AVA, AVL and AVB. That is, A.V.C finished with asbestos braid is Type AVA, with lead sheath is Type AVL and with cotton btaid is Type AVB. THE HM STORY Maximum current earning capacities of insulated con ductors are determined within practical limits by the mairtmiifn temperature the insulation will stand without undue deterioration. The Code in rating this original Rodcbestos A.V.C. con struction permitted it a higher temperature limit than ordinary insulations because its impregnated felted as bestos walls safely resisted deterioration under high am bients and the heat from current loads. Chapter 10, Ta bles I and II, under "Allowable Current-Carrying Capadries at 30C" list Rockbestos A.V.C Type AVA con struction with greater current carrying capadty size for size than for cables with ordinary insulations. The prac tical advantages of Rodcbestos A.V.C. begin here. As ambient temperatures increase and correction factors are applied, A.Y.C is de-rated far less than ordinary con structions, all because of its insulation. At 70C, for instance, other types of Insulations are de rated as much as 65% while Kockbestos A.V.C. is de rated only 29%. At ambient temperatures in excess of 85C a limiting point for other types of insulations, Rockbestos A.V.C. rated at 110C continues to provide permanent protection for electrical circuits. Plant layouts and expansion programs ate given greater flexibility by installing Rodcbestos A.V.C. because not only does it provide greater current carrying capadty for intermittent demands and future load growth in existing dreuits, but the installation of heat generating equipment is not restricted by its nearness to vital electrical circuits. The fact that you can use a smaller sized cable to carry a given load can start a whole series of cumulative sav ings. Smaller cable means smaller conduit and fittings. Easier, quicker installations, plus years of dependable perfor mance, prove Rodcbestos Hi-I A.V.C.... Your Best Buy. ROCKBESTOS A.V.C. CONSTRUCTION (1) First impregnated felted asbestos wall. (2) Varnished cambric tapes. (3) Second impregnated felted asbestos wall. (4) impregnated asbestos braid for Type AVA cables. (Flameproof cotton braid for Type AVB cables.) (Lead Sheath for Type AVL cables.) RBB 00476 TYPICAL APPLICATIONS FOR POWE WHERE SUBJECTED T< 6 POWER CIRCUITS UP TO 5000 VOLT SBtVICE Standard Rockbestos A.V.C. (Code Type AVA) Power Cables are available in voltage ratings of 600 to 5000 volts. They are designed to protea circuits that must operate without failure un der continuous exposure to high temperatures and other severe operating conditions. Copper shielding can be provided where re quired. They are available in single or multi-conductor construc tions with either lead sheaths or asbestos braids. Interlocking armor can be furnished to special order. Rockbestos A.V.C. (Code Type AVA) Power Cable constructions are approved by the Na tional Electrical Code, listed by the Underwriters* Laboratories and conform-'to NEMA standards. CONDUIT WIRING AROUND FURNACES, OVENS, SOAKING PITS, BOILERS, ETC. Rockbestos A.V.C Power Cables and Lighting Wires can be run in conduit as they are built to withstand the normal moisture con ditions resulting from condensation caused by heating and cooling cycles. In cases where power and lighting circuits are exposed to high temperatures in combination with excessive condensation or complete submersion, use lead sheathed Code Type AVL. LIGHTING AND POWBt CIRCUITS Rockbestos Hi-I A.V.C (Code Type AVA) Lighting and Power Cables are high temperature cables. This A.V.C construction-- rwo layers of impregnated felted asbestos encasing the varnished cambric--permits continuous operation at copper temperatures of 250F (110C), thus making Hi-I cables ideal for high ambient "Hot Spot** locations or, in normal ambient installations, per mitting the use of smaller cables with consequent savings of cop per, conduit, fittings and man-hours of labor as compared with cables having ordinary insulation. 6 RBB 00477 LIGHTING and CONTROL CIRCUITS HIGH TEMPERATURES ** RHEOSTAT AND APPARATUS WIRING Rodcbestos All-Ast>cstos Rheostat Wires and Cables were design ed primarily for open wiring. Operating temperatures of 125C for 600 volt ratings and 200C for 300 volt applications can be safely met as constant elevated temperatures will not cause the compounds to fall away or flake off even through repeated heat ing and cooling cycles. It is especially recommended for grid jumper connections from grids to faceplates, ovens and element leads on well type anneal ing furnaces and open wiring exposed to extremely high temper atures, corrosive fumes, grease, oil ot fire hazard. SWITCHBOARDS AND PANEL BOARDS Millions of feet of Rodcbestos fireproof A.V.C (N.E.C. Type AVB) Switchboard Wire have been used by switchboard manu facturers, power stations and industrial plants since we originated and patented the A.V.C. type. Fine appearance is assured complet ed boards because it can be bent at right angles without cracking the braid. Rockbestos A.V.C. Switchboard Wires have a maximum operating temperature of 90C (194F) and are listed by the Underwriters' Laboratories. They comply with the NEMA Small Wiring for Switchboards Standard and are approved by Factory Mutual Lab oratories, switchboard manufacturers and power companies. See Page 42 for Rodcbestos synthetic and asbestos insulated switch board wires, N.E.C. Type TA constructions. MOTOR LEADS ^Mill motors and other heavy duty stationary and traction types us Rodcbestos A.V.C. Motor Lead and Apparatus Cable for pro tection against conductor-heating overloads and high ambien temperatures. This cable retains its flexibility indefinitely becausi it won't dry out with heat or age, won't rot or bloom from con tact with oil or grease and won't burn or carry flame. These per forcnance-protecting characteristics make it ideal for motor wiring in steel mills, generating stations, all types of coal mining equip ment, industrial plants--and numerous electrical apparatus app iications. RBB 00478 7 POWER CABLE NEC TYPE AVA--ROCKBESTOS A.V.C. 600 TO 5,000 VOLT RATINGS SINGLE CONDUCTOR--STRANDED APPLICATIONS Rockbestos A.V.C. (N.E.C Type AVA) Power Cables are designed to operate at voltages from 600 to 5000 volts. They are especially recommended for circuits ex posed to severe operating conditions in power stations, steel mills, refineries, tanneries, smelters, etc. and for apparatus which operates under high ambient temper atures. On the higher voltage rated cables, suitable copper shielding tapes may be specified to eliminate effects of corona on the primary dielectric--the varnished cam bric. Voltage rating of all Rockbestos Hi-I A.V.C. Power Cables is maximum phase to phase voltage. This applies to either grounded or ungrounded systems. The cables listed in this section have ample moisture resistance for average conditions, but if there is a pos sibility that circuits may be submerged in water for long periods, use lead sheathed constructions in the AVL section of this catalog. The wires and cables in this section are approved National Electrical Code Types, listed by the Underwriters' and fulfill the re quirements of NEMA for Asbestos-Varnished Cambric wires and cables. SPECIFICATIONS Construction 1. Stranded plain copper conductor 2. Felted asbestos 3. Varnished cambric 4. Felted asbestos 5. Asbestos braid Maximum conductor operating temperatures follows: 600 Volt 1000 Volt 2000 Volt 3000 Volt 4000 Volt 5000 Volt 110C 110C 109C 106C 103C 100C (230F) (230F) (228F) (222F) (217F) (212F) Standard finish colors: Black and white. Authorized Stock item: (600 volt-Table E only) Black. Flexible standings may be specified on all construc tions up to 5000 volts. AH constructions listed can be covered with lead sheath, armor, or lead sheath and armor, if desired. Interlock ing armor can be furnished to special order. RBB 00479 ROCKBESTOS A.V.C. SINGLE CONDUCTOR POWER CABLE TABLE E, 600 VOLTS MAX. OPERATING TEMP. I10C (230F) TABLE H, 5000 VOLTS MAX. OPERATING TEMP. 100C (212#F) Size Stranding # TABLE E I8AWG 16 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 250.000 CM 900.000 330.000 400.000 450.000 300.000 550.000 600.000 630.000 700.000 750.000 800.000 850.000 900.000 950.000 1.000.000 1.250.000 1.300.000 1.750.000 2.000.000 7/.0152 7/.0192 7/.0242 7/.O305 7/.0385 7/.0486 7/.0612 7/.0668 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0973 37/.1040 37/.1103 37/.1162 61/.0950 61/.0992 61/.1032 61/.1071 61/.1109 61/.1145 61/.1180 61/.1215 61/.1248 61/.1280 91/.1172 91/.1284 127/.1174 127/.1255 TABLE H Bere Diem. laches .046 .058 .073 .092 .116 .146 .184 .206 .232 .260 .292 .332 .373 .419 .470 .328 .575 .630 .681 .728 .772 .813 .855 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 1.289 1.412 1.526 1.632 Nomine! Thickness -- Mils 1st Felted Well VC Insert 2nd Felted Asbestos Well Breid Nomine! Finished Diemeter Iwrlwi 600 VOLTS 10 30 13 40 .235 10 30 15 40 .250 10 30 15 40 .265 10 30 15 40 .283 10 30 15 40 .310 10 30 15 45 .350 15 30 20 45 .405 15 30 20 45 .430 15 30 20 45 .455 15 30 20 43 .480 15 30 20 45 .515 20 30 30 45 .565 20 30 30 45 .625 20 30 30 43 .670 20 30 30 43 .720 20 30 30 45 .780 25 40 40 45 .875 25 40 40 45 .930 23 40 40 43 .983 23 40 40 45 1.030 25 40 40 45 1.075 25 40 40 45 1.115 30 40 40 45 1.165 30 40 40 45 1.205 30 40 40 45 1.240 30 40 40 45 1.275 30 40 40 45 1.310 30 40 40 45 1.345 30 40 40 45 1.375 30 40 40 45 1.405 30 40 40 45 1.435 30 40 40 45 1.465 30 50 50 45 1.640 30 50 50 45 1.765 30 50 50 45 1.880 30 50 50 45 1.985 5000 VOLTS Approx. Net Wgt in Lbs. per 1000' 30 35 43 55 70 95 140 165 200 240 285 370 430 H5 665 815 985 1155 1325 1490 1660 1825 2005 2175 2340 2505 2675 2835 3000 3165 3330 3490 4375 5155 6030 6760 tStxnderd Shipping Length Feet Approx. Shipping Weight per 1000' TYPE AVA 500' C 500' C 500' C 300'C 300'C 500'C 500'R 300'R 500'R 300' R 300'R 300'R 500'R 300'R 500' R 500' R 500'R 500' R 500'R 300'R 500' R 500'R 500' R 500'R 500'R 500' R 500'R 500'R 500' R 500'R 500' R 500' R 300'R 500'R 500'R 500' R 37 43 56 68 87 118 175 206 250 300 356 462 562 681 831" 1018 1231 1443 1636 1862 2075 2281 2506 2718 292 5 3131 3343 3543 3750 3956 4162 4362 5468 6443 7537 8450 TYPE AVA I0AWG 8 6 5 4 3 2 1 0 00 000 0000 250.000 CM 300.000 350.000 400.000 450.000 500.000 550.000 600.000 650.000 700.000 750.000 800.000 830.000 900.000 950.000 1.000.000 7/.0385 7/.0486 7/.06I2 7/.0688 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1035 37/0822 37/.0900 37/.0973 37/.1040 37/.1103 37/.1162 61/.0950 61/.0992 61/.1032 61/.1Q71 61/.U09 61/.1145 61/.1180 61/.1215 61/.1248 61/.1280 .116 .146 .184 .206 .232 .260 .292 .332 .373 .419 .470 .528 .575 .630 .681 .728 .772 .813 .855 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 15 15 15 15 15 15 15 20 20 20 20 20 25 25 25 25 25 25 30 30 30 30 30 30 30 30 30 30 120 25 45 .530 150 500'R 120 25 45 .560 190 500'R 120 25 45 .595 230 500'R 120 25 45 .620 260 500' R 120 25 45 .645 295 500'R 120 25 45 .670 345 500' R 120 25 45 .705 395 500'R 120 30 45 .765 490 500' R 120 30 45 .805 555 500' R 120 30 45 .850 670 500'R 120 30 45 .900 795 500' R 120 30 45 .960 955 500' R 120 40 45 1.035 1120 500'R 120 40 45 1.090 1300 120 40 45 1.145 1480 120 40 45 1.190 1660 120 40 45 1.235 1825 500'R 120 40 45 1.275 2010 500' R 120 40 45 1.325 2185 500' R 120 40 45 1.365 2360 500' R 120 40 45 1.400 2530 500'R 120 40 45 1.435 2700 500' R 120 40 45 1.470 2870 500' R 120 40 45 1.505 3040 500' R 120 40 45 1.535 3210 500' R 120 40 45 1.565 3360 500' R 120 40 45 1.595 3530 500' R 120 40 45 1.625 3720 500' R Finished diameters gireo shore ste trerafe. A tolerance of plus or minus $% if necessary due to rariation in process of manufacture. R--Reels 187 237 287 325 366 431 493 612 693 837 993 1193 1400 1625 1850 2075 2281 2512 2731 2950 3162 3375 3587 3800 4012 4200 4412 4650 RBB 00480 9 ROCKBESTOS A.V.C. 600 VOLT CONTROL CABLE TYPE AVA--ROCKBESTOS A.V.C. MAXIMUM OPERATING TEMPERATURE: 110C <230F) ft \i f ''"''"''fi?,',,*}-...vW ' 7 4 * ai APPLICATIONS Modified in design from our Soaking Pit Cable for covet door control wiring which must withstand the intense heat of red-hot ingots whea adjacent covers are off, this A. V. C control able has proven resistance to high temperatures. This cable finds its use in steel mills, power stations, boiler rooms, automotive, ceramic and glass plants or other indus tries in which control and signal circuits or control appara tus are exposed to heat oc fire hazard. It is especially recom mended for use in circuits and apparatus in metal making mills, boiler rooms, and power plants as it is highly resistant Conductors The standard stranding; furnished on these Rockbestos A.V.C. Control Cables is 19/22 (No. 9 A.W.G.) and 19/25 (No. 12 A.W.G.) but any desired stranding can be furnished to order and cabled into any required number of conductors. Insulation The insulation of the individual conductors is the same type as that on the power cables described on the previous pages with the exception of the outer braid which is a color coded cotton braid to obtain circuit identification. When furnished for single conductor use asbestos braid replaces cotton braid. Impregnated felted asbestos walls seal the varnished cambric from heat, flame and oxidation. Moistureproof tape is wrapped over the cabled conductors and the to heat, corrosive fumes, oil, grease and flame and has ample moisture resistance for installation either open or in conduit. Under exposure to flame this cable will maintain vital control and alarm system circuits for longer periods than other types of insulated cables. SPECIFICATIONS 1. Tinned copper conductor 5. Color coded cotton btaids 2. Felted asbestos 6. Cable tape 3. Varnished cambric 7. Asbestos braid ............4. Feltedasbestos This cable is NEMA TYPE AVA with a maximum operat ing temperature of 110C (230F). outer covering of tough, braided asbestos yarn is finished with heat, flame and moisture resisting compounds. Coding The individual wires ate braided in colors accotding to the NEMA standard color code for multi-conductor cable, which is reproduced below. Special color combinations can be furnished to specification. Lead or Armor Covering These cables may be made up wirh either lead sheath, armor, oc lead sheath and armor coveting. Synthetic sheathing is optional also where temperatures permit. Finish The standard finish of the outer braided asbestos jacket is a black, flame, heat and moisture resisting compound. NEMA STANDARD COLOR CODE FOR MULTI-CONDUCTOR CONTROL CABLE Conductors 1 2 3 4 5 6 Base Color Black White Red Green Orange Blue Conductors 7 8 9 10 11 12 13 Base Color White Red Green Orange Blue Black Red Tracer Black Black Black Black Black White White Conductors 14 15 16 n 18 19 Base Color Green Blue Black White Orange Blue Tracer White White Red Red Red Red 0. 0 10 RBB 00481 . 600 VOLT CONTROL CABLE TYPE AVA--ROCKBESTOS A.V.C Nominal sizes--9 and 12 AWG 1-19 Conductors (See Opposite Page for General Information) Standard conductor sizes are AWG No. 9-19/22 and No. 12-19/25 tinned copper, insulated with a 10 mil wail of felted and impregnated asbestos, 30 mil wall varnished cam bric insert, another 15 mil wail of felted asbestos and a cotton braid colored according to die NEMA Control Cable Color Code for Multi-Conductor Cables, listed on the oppo site page. The individual conductors are then cabled with jute fillers where necessary, a layer of cable tape is applied and finally an asbestos braid finished with black, flame, heat and moisture resisting compound. The standard make-up on two conductor construction is to cable the conductors with fillers to make round, but it can also be furnished in parallel construction. Parallel must be specified if desired. Lead sheath, armor, lead sheath and armor or synthetic sheathing can be substituted instead of asbestos braid. Spec ify preference. These Rockbestos A.V.C. control cables can also be made up with No. 14, 16 and 18 A.W.G. conductors. TABLE MD (awg No. 12.19/25) 600 VOLTS TYPE AVA Number of Conductors Stranding Bare Diam. Inches Braid Thickness Finished Diam. Inches Nominal Approx. NW|t in Lbs. per 1000' tSundard Shipping Length Feet Approx. Shipping Weight per 1000' ! 2 3 4 5 6 .7 8 9 10 11 12 13 14 15 10 17 18 19 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 .090 .090 .090 .090 .090.090 .090 .090 .090 .090 .090 .090 .090 .090 .090 .090 .090 .090 .090 40 .280 52 45 .545 145 45 .585 180 45 .645 230 45 .710 260 45 .780 305 45 .780 330 45 .850 380 45 .920 435 45 1.000 470 45 1.000 495 45 1.035 535 45 1.065 580 45 1.095 620 45 1.135 670 45 1.160 705 45 1.205 755 45 1.230 790 45 1.230 815 500'R 500' R 500'R 500' R 500' R 500' R 500'R 500' R 500'R 500' R 500' R 500'R 500' R 500'R 500' R 500' R 500' R 500' R 500' R 65 181 225 228 325 381 413 475 544 588 619 669 725 775 838 881 944 988 1019 TABLE MT (awg No. 9-19/22) 600 VOLTS TYPE AVA **1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 40 .320 80 45 .630 215 45 .670 275 45 .740 340 45 .820 395 45 .900 475 45 .900 535 45 .985 590 45 1.070 45 1.160 45 1.160 45 1.200 670 735 795 845 45 1.235 915 45 1.275 970 45 1.320 1040 45 1.350 1105 45 1.405 1180 45 1.430 1245 45 1.430 1310 500' R 500'R 500' R 500'R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500'R 500'R 500'R 500'R 500'R Q 'Finished diameters fives above ire average. A tolerance of plus or minus 5% is necessary due to variation in process of manufacture. tR--Reefs Single conductor has no cotton braid. Asbestos braid is applied directly over insulation. 'Can be lurniafaed either parallel or cabled with fillers to make round. Specify which. 100 269 344 425 494 594 669 738 838 919 994 1056 1144 1213 1300 1381 1475 1556 1638 RBB 00482 n t Sizes 16-8 ROCKBESTOS A.V.C. LIGHTING WIRE NEC TYPE AVA--ROCKBESTOS A.V.C 600 VOLT SOLID CONDUCTOR MAXIMUM OPERATING TEMP. nOC (230Fl Sizes *4/0 *a t a' APPLICATIONS SPECIFICATION This wire is recommended for lighting and control circuits Construction--Sizes 6-4/0 i in boiler rooms, steel mills, steam runnels, power, chemical 1. Solid Plain Copper Conductor and food processing plants. Also around furnaces, ovens, 2. Felted Asbestos glass lehrs, forging presses, tenter frames, soaking pits--and 3. Varnished Cambric in locomotives, resistors, cranes, steam tables, etc. for circuits exposed to heat. 4. Felted Asbestos 5. Asbestos Braid National Electrical Code Type AVA--listed by Underwrit You can safely use this lighting wire either open wired or in conduit, ducts or raceways which are exposed to heat and ers' Laboratories, maximum conductor operating temperature U0C (230F). *^ moisture, corrosive fumes, grease, oil or fire hazard. It is also Construction--Sizes 18*8 used in electrical apparatus for panel and control wiring to insure performance under severe operating conditions. This construction permits continuous operation under tempera tures ranging up to a maximum of 230F. It has ample moisture resistance for average conditions, but l. Solid Plain Copper Conductor 3. Varnished Cambric 4. Felted Asbestos 5. Asbestos Braid National Electrical Code Type AVA--listed by Underwr^ maximum conductor operating temperatu^ if there is a possibility that circuits may be submerged for long periods use Table CL, Rockbestos A.V.C. (N.E.C. Type AVL) 600 volt lead sheathed lighting wire on page 14. Standard finish colors: Black and white. Authorized stock items: Black, (white also in sizes Nos 10 12 and 14.) ' '' table C600 VOLTS___________________________________________________ TYPE AVA Size Bare Diam. Inches 1st Felted Wall 18 AWG 16 to 8 0 .040 .051 .064 .081 .102 .128 .162 .182 .204 .229 .258 .289 .325 .365 .410 .460 15 15 15 15 15 20 20 20 20 20 Finuhed diameters lives above ere itsiit. Nat itsitd in National Electrical Code. Nominal Thic kness -- Mils VC Insert 30 30 30 30 30 30 30 30 30 30 30 30 50 30 30 30 2nd Felted Wall 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 Asbestos Braid 40 40 40 40 40 40 45 45 45 45 45 45 45 43 45 45 *Nominal Finished Diam. Inches .220 .235 .245 .265 .285 .310 .385 .405 .425 .450 .480 .540 .575 .615 .660 .710 Approx. Net Wgt. in Lbs. per 1000' 28 33 40 50 65 89 135 160 190 230 275 350 430 525 640 785 ^Standard Shipping Length Feet 500'C 500' C 500' C 500' C 500' C 500' R 500'R 500' R 500' R 500'R 500'R 500' R 500'R 500' R 500'R Apprux. Shipping Weight per lOou' 35 62 81 200 437 981 tolerance of plui or tntoui J*> u necessary due to variation in process of manufacture. T--K--Reels 12 RBB 00483 ROCKBESTOS A.VX. 600 VOLT FLEXIBLE CONDUCTOR MOTOR LEAD and APPARATUS CABLE NEC TYPE AVA--ROCKBESTOS A.V.C. MAXIMUM OPERATING TEMP. 110C (230F) APPLICATION This cable was designed and developed to meet the demand for greater resistance to conductor-heating overloads, high ambient temperatures, other destructive conditions and fire hazard. It is widely used in electrical apparatus for coil con nections and motor leads on either AC or DC. Because of its A.V.C. construction it is ideal for wiring transformers, re sistors, hoists, cranes, traction and mill motors which must function under exposure to heat and moisture, corrosive fumes, grease or oil. SPECIFICATIONS Construction 1. Flexible tinned copper conductor 2. Felted asbestos 3. Varnished cambric 4. Felted asbestos 5. Asbestos braid This cable is National Electrical Code Type AVA, maximum operating temperature 110C (2J0F) listed by the Under writers' Laboratories. Rockbestos Motor Lead and Apparatus Cable is available in voltage ratings up to 5000 volts and may be furnished with extra-flexible conductors. Standard finish colors: Black and white. Authorized stock items; Black. TABLE L600 VOLTS TYPE AVA Size Stranding "18 AWG "16 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 250.000 CM 300.000 350.000 400.000 450.000 500.000 550.000 600.000 650.000 700.000 750.000 800.000 900.000 1.000.000 16/.010 26/.010 41/.010 65/.010 I04/.010 133/.0111 133/.0140 133/.0158 133/.0177 133/.0199 133/.0223 259/.0180 259/.0202 259/.0227 259/.0255 259/.0286 427/.0242 427/0265 427/.0286 427/.0306 427/.0325 427/.0342 427/.0359 427/.0375 427/.0390 427/.0405 427/.04I9 427/.0433 427/.0459 427/.0484 Diam. Inches .045 .059 .075 .095 .120 .167 .210 .237 .266 .299 335 .378 .424 .477 .536 .601 .653 .716 .772 .826 .878 .923 .969 1.013 1.053 1.094 1.131 1.169 1.239 1.307 Nominal Thickness--Mils 1st Felted Wall vc Insert 2nd Felted Asbestos Wall Braid 10 30 15 40 10 30 15 40 10 10 30 30 15 40 15 40 10 30 15 40 10 30 15 45 15 15 30 20 45 30 20 45 15 15 15 20 30 30 30 30 20 45 20 45 20 45 30 45 20 20 20 20 30 30 30 30 30 45 30 45 30 45 30 45 25 25 40 40 40 45 40 45 25 40 40 45 25 40 40 45 25 40 40 45 2,S 40 40 45 40 40 45 30 40 40 45 30 40 40 45 30 40 40 45 30 40 40 45 30 40 40 45 30 40 40 45 30 40 40 45 Nominal Diam. Inches .235 .250 .265 .285 310 -370 .430 .460 .490 .520 .555 .630 .675 .730 .790 .855 .955 1.020 1.075 1.130 1.180 1.225 1.280 1.325 1.365 1.405 1.445 1.480 1.550 1.620 Approx. Net Wgt. in Lbs. per 1000' 30 35 45 55 75 100 150 175 210 255 306 385 470 570 700 850 1030 1205 1380 1555 1740 1905 2100 2305 2440 2570 2780 2855 3223 3590 fStandard Shipping Length Feet 500' C 500'C 500'C 500'C 500'C 500'C 500' R 500' R 500' R 500' R 500' R 500'R 500'R 500' R 500' R 500'R 500' R 500'R 500'R 500'R 500' R 500' R 500'R 500'R 500' R 500'R 500'R 500'R 500' R 500' R Approx. Shipping Weight per 1000' 36 41 51 61 81 106 187 218 262 318 381 481 587 712 875 1062 1287 1506 1725 1943 2175 2381 2625 2881 3050 3212 3475 3568 4028 4487 'No^lUced*'Cod."***' A toltnf,n ol plul tainul wtmr, * to variation ir. ptoctu of mamfeom. R-Rttl* RBB 00484 T3 LEAD SHEATHED POWER CABLE NEC TYPE AVL--ROCKBESTOS A.V.C. 600 TO 5/000 VOLT RATINGS SINGLE CONDUCTOR- STRANDED * * APPLICATIONS These Rockbestos Lead Sheathed Power Cables are used for Power and Lighting Circuits exposed to high temperarures in combination with excessive condensation or complete submersion. Use this cable where a conduit run is exposed to widely vary ing conditions throughout its length, particularly in power stations located on tidewater where certain ducts are some times flooded but where another section of the same circuit is exposed to high temperatures. Also around ash pits where the wetting down of the ashes results in abnormal conden sation. The Cables listed in this section all conform to NEMA Standards for Asbestos Varnished Cambric wires and cables with lead sheath. The lead sheath has no effect on the ability of these cables to withstand high temperatures but affords protection against abnormal condensation or complete submersion. SPECIFICATIONS Construction 1. Stranded plain copper conductor 2. Felted Asbestos 5- Varnished cambric 4. Felted asbestos 5- Lead sheath This cable is National Electrical Code Type AVL, listed by the Underwriters' Laboratories and is available in sizes up to 2,000,000 CM. Maximum operating temperatures are as follows: 600 Volt 110C (250F\ 1000 Volt 110C (230F) 2000 Volt 109C (228F) 3000 Volt 106C (222F) 4000 Volt 103C (217F) 5000 Volt 100C (212F) These cables are our Standard Power Cable constructions with a lead sheath instead of an asbestos braid. LIGHTING WIRE LEAD SHEATHED (SOLID) MAXIMUM OPERATING TEMP: nOC (230F) ' !. SOLID PLAIN COPPER CONDUCTOR * 2. PEITEO ASBESTOS ** 3. VARNISHED CAMBRIC 4. FELTED ASBESTOS S. A0 SHEATH Size Diam. Inches TABLE CL Nominal Thickness - Mils ! Lead 1st Felled Wall VC Insert 2nd Felted Thickness Wail : inches 600 VOLTS Nominal i Diam. 1 Inches : Approx. in Lbs. per 1000' * Standard i Length Feet Approx. Shipping Weight per 1000' TYPE AVI 18 AWG *16 i: .040 .051 .064 .081 30 25 i 3/64 .245 1 170 500' R ; 30 25 ! 3/64 .255 ISO 500' R ' 30 25 : 3/64 .270 200 500' R 30 25 i 3/64 .285 220 500' R 10 .102 30 25 ! 3/64 .310 ! 250 500' R 8 .128 30 25 i 3/64 335 i 2S5 500' R 6 .162 15 30 25 3/64 .400 ; 350 500' R 5 .182 15 30 25 3/64 .420 l 420 500' R 4 .204 15 25 ' 3/64 .440 ! 465 500'R .220 15 30 25 ' 3/64 .465 : 520 500'R _ .258 15 30 25 3/64 .495 i 5S5 500' R 1 .239 20 30 30 . 4/64 .575 | 830 500'R 0 00 000 0000 .325 20 30 30 : 4/64 .610 | 940 500' R .365 20 30 30 4/64 .650 1 1070 500' R .410 20 30 30 . 4/64 .695 ; 1225 500' R .460 20 30 30 i 4/64 .745 i 1415 500'R 'Finished diameters given above are average. A tolerance of plot or minus fK it necejury due to variation in process of manufacture. *R--Reeli Not lined m National Electrical Code. 212 225 250 275 312 356 4-5 525 581 650 731 1037 1175 1337 1531 1768 14 RBB 00485 ROCKBESTOS A.V.C. LEAD SHEATHED SINGLE CONDUCTOR POWER CABLE MAX. OPERATING TEMP. 103C (217FI MAX. OPERATING TEMP. 100C (212F) Size Stranding TABLE EL 18AWG 16 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 250.000 CM 300.000 350.000 400.000 450.000 500.000 550.000 600.000 650.000 700.000 750.000 800.000 830.000 900.000 950.000 1.000.000 1.250.000 1.500.000 1.750.000 2.000.000 7/-0152 7/.0192 7/.0242 V.0305 7/.0385 7/.0486 7/.0612 7/.0688 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/-0837 19/ 0940 19/.1055 37/0822 37/.0900 37/.0973 37/.1040 37/.1103 37/.1162 61/.0950 61/.0992 61/.1032 61/.1071 61/.1109 61/.U45 61/.1180 61/. 1215 61/.1248 61/.1280 91/.1172 91/.1284 127/.1174 127/.1255 TABLE HL Bare Dram. Inches .046 .058 .073 .092 .116 .146 .184 .206 .232 .260 .292 .332 .373 .419 .470 .528 .575 .630 .681 .728 .772 .813 .855 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 1.289 1.412 1.526 1.632 Nominal Thickness -- Mils 1st Felted Wail vc Insert 2nd Felted Wall Lead Sheath Thickness Inches Nominal Finished Diam. inches 600 VOLTS 10 30 25 3/64 .270 10 30 25 3/64 .285 10 30 25 3/64 .300 10 30 25 3/64 .320 10 30 25 3/64 .340 10 30 25 3/64 .370 15 30 25 3/64 .420 15 30 25 3/64 .440 IS 30 25 3/64 .470 15 30 25 3/64 .495 15 30 25 4/64 .560 20 30 30 4/64 .620 20 30 30 4/64 .660 20 30 30 4/64 .705 20 30 30 4/64 .760 20 30 30 4/64 .815 25 40 40 5/64 .945 25 40 40 5/64 1.000 25 40 40 5/64 1.050 25 40 40 5/64 1.095 25 40 40 5/64 1.140 25 40 40 5/64 1.180 . 30 40 40 6/64 1.265 30 40 40 6/64 1.300 30 40 40 6/64 1.340 30 40 40 6/64 1.375 30 40 40 6/64 1.405 30 40 40 6/64 1.440 30 40 40 6/64 1.470 30 40 40 6/64 1.500 30 40 40 6/64 1.530 30 40 40 6/64 1.560 30 50 50 7/64 1.770 30 50 50 7/64 1.890 30 50 50 7/64 2.005 30 50 50 7/64 2.110 5000 VOLTS Approx. Net Wgt. in Lbs. per 1000' 195 205 225 250 275 325 395 445 490 550 745 875 1000 1125 1290 1490 1985 2240 2445 2665 2925 3095 3780 3870 4130 4250 4515 4720 5030 5140 5395 5540 7135 8140 9210 10120 tStandard Shipping Length Feet Approx. Shipping Weight per 1000' TYPE AVL 500' R 500'R 500' R 500'R 500'R 500' R 500' R 500'R 500'R 500'R 500' R 500'R 500' R 500' R 500' R 500' R 500' R 500' R 500'R 500' R 500'R 500'R 500'R 500'R 500'R 500'R 500'R 500' R 500'R 500'R 500'R 500' R 500' R 500'R 500'R 500'R 243 256 281 312 343 406 493 556 612 687 931 1093 1250 1406 1612 1862 2481 2800 3056 3331 3656 3868 4725 4837 5162 5312 5643 5900 6287 6425 6743 6925 8918 10175 11512 22650 TYPE AVL 10 AWG 8 6 5 4 3 2 1 0 00 000 0000 250.000 CM 300.000 350.000 400.000 450.000 500.000 550.000 600.000 650.000 700.000 750.000 800.000 850.000 900.000 950.000 1.000.000 7/.0385 7/.0486 7/.0612 7/.0688 7/.0772 7/-0867 7/.0974 19/.0664 19/-0745 19/.0837 19/-0940 19/.1055 37/.0822 37/-0900 37/.0973 37/.1040 37/1103 37/.1162 61/.0950 61/.0992 61/.1032 61/.1071 61/.U09 61/.U45 61/.1I80 61/.1215 61/.1248 61/.I280 .116 .146 .184 .206 .232 .260 .292 -332 373 -419 .470 .528 .575 .630 .681 .728 .772 .813 .855 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 15 120 15 120 15 120 15 120 15 120 15 120 15 120 20 120 20 120 20 120 20 120 20 120 25 120 25 120 25 120 25 120 25 120 25 120 30 120 30 120 30 120 30 120 30 120 30 120 30 120 30 120 30 120 30 120 25 4/64 .565 25 4/64 .595 25 4/64 .630 25 4/64 .655 615 500' R 674 500' R 750 500'R 820 500' R 25 4/64 .680 860 500' R 25 4/64 .705 930 500' R 25 4/64 .740 1010 500' R 30 4/64 .800 1150 >00' R 30 5/64 .870 1480 30 5/64 .915 1645 500' R 30 5/64 .970 1830 500' R 30 5/64 1.025 2055 500' R 40 5/64 1.105 2305 500'R 40 5/64 1.160 2544 500'R 40 6/64 1.240 3095 500'R 40 6/64 1.290 3335 500'R 40 6/64 1.330 3565 40 6/64 1.375 3800 40 6/64 1.425 4040 40 6/64 1.465 4280 500'R 40 6/64 1.500 4495 500' R 40 6/64 1.535 4715 40 6/64 1.570 4930 40 6/64 1.600 5145 500` R 40 6/64 1.630 5398 40 6/64 1.665 5570 40 7/64 1.725 6234 40 7/64 1.755 6430 500' R 'Finished diameter* given above are average. A tolerance of plus or minus i% it necessary due to variation in process of manufacture. tR--Reels 768 842 937 1025 1075 1162 1262 1437 1850 2056 2287 2568 2881 3180 3868 4168 4456 4750 5050 5350 5618 5893 6162 6431 6747 6962 7792 8037 RBB 00486 SPECIAL CONSTRUCTIONS FOR ROCKBESTOS POWER AND CONTROL CABLES I I This Rockbestos A.V.C. Control Cable illustrated is one of the many multi conductor cables designed to meet specific requirements in control and power circuits. They are made up as shown or with either lead sheath or armor only as specified and in ratings ranging from 600 to 3000 volts. (Synthetic sheath ings may also be specified for control cables where temperatures permit.) I This type of cable not only protects operation of circuits exposed to heat and moisture and other severe operating conditions, but also increases the flexi bility of wiring systems and makes circuits mote easily accessible. The felted asbestos insulation, impregnated with heat, flame and moisture resisting compounds, withstands high temperatures, corrosive fumes, aging and conductor-heating overloads. The lead sheath protects it from excessive condensation resulting from heating and cooling cycles and complete sub mersion. The spiral bronze armor eliminates the need for conduit, an impor tant consideration in capacity expansion programs, as the cable can be run in troughs, up vertical risers or over and around obstructions. Its flame and heat resistant structure will also maintain vital alarm and control system ciri cuits for longer periods under exposure to flame than other conventional , trpcs- The cable illustrated on this page is a special construction which is typical of ! many "specials" designed by Rockbestos to meet severe oc unusual operating conditions. Its construction consists of: Conduit saving bronze armor covering for protection against abrasion. Impregnated jute serve to cushion the armor and to protect the lead sheath from mechanical damage. I Lead sheathing for protection against immersion or excessive condensation. I Friction tape to bind the cabled conductors securely together to maintain the | lay. INDIVIDUAL CONDUCTORS Coded individual cotton braided conductors for easy circuit identification. Felted asbestos beneath the cotton braid impregnated with heat, flame and moisture resistant compounds. Varnished cambric for high dielectric strength and added moisture resistance Inner wall of felted asbestos to complete the A.V.C. construction serving as a baffle between the varnished cambric and heated conductors. 16 RBB 00487 ROCKBESTOS A.V.C 600 VOLT SWITCHBOARD WIRES t NEC TYPE AVB--ROCKBESTOS A.V.C. TABLE 8--SOLID TABU BS--STRANDED. MAXIMUM OPERATING TEMP. 90C <194F) 1. SOHO OR STRANDED TINNED CORREI CONDUCTOR 2. VARNISHED CAMIRIC 3. FELTED ASIESTOS 4. FUMEFIOOF COnON (RAID FOR SWITCHBOARDS, RADIO AND TELEVISION TRANSMITTERS, MOTOR DRIVEN RHEOSTATS, CONTROL PANELS FOR MOTOR STARTERS, ELEVATORS, FIRE DOORS. CRANES, INDUCTION HEATING APPARATUS, OIL BURNING BOILER UNITS, ETC Standard finish colors; Gray and Black. Authorized stock items: Gray. TABLE B (Solid) Size 18AWG 16 14 12 10 8 6 5 4 "2 0 00 000 0000 Bare Diets. Tnriwi .040 .051 .064 .081 .102 .US .162 .182 .204 .229 .258 .289 .325 .365 .410 .460 600 VOLTS Nominal Thickness -- Mils VC Felted Wall CoROO Braid Nominal Finished Diam. Inches 30 20 16 .175 30 20 16 .185 30 20 16 .200 30 20 16 .220 30 20 17 .240 30 20 17 .270 40 30 17 .340 40 30 17 .360 40 30 17 .360 40 30 20 .415 40 30 20 .445 40 40 20 .495 40 40 20 .530 40 40 20 .570 40 40 20 .615 40 40 20 .665 Apptox. Net Wgt in Lbs. per 1000' 20 25 30 40 55 80 125 150 175 215 260 330 405 495 610 750 TYPE AVB l ^Standard j Shipping I Length 1 Feet Approx. Snipping Weight per 1000' 1 500* C ! 500'C * 500'C ! 500' C 1 500' C 1 500' C 1 500'R 1 500'R i 500'R 500' R 1 500' R i 500' R ' 500'R i 500'R i\ 550000'' RR 25 31 36 46 61 86 156 187 218 268 325 412 506 618 762 937 TABLE BS (Stranded) 600 VOLTS TYPE AVB Size | Stranding 16 AWG 14 U 10 8 6 5 4 3 0 00 000 0000 ! 7/.0192 : 7/.0242 77.0305 7/.0385 7/.0486 7/.0612 7/.0688 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 Bare Diam. Inches .058 .073 .092 .116 .146 .184 .206 -232 .260 .292 .332 .573 .419 .470 .528 Nominal Thickness --Mils vc Felted Wall Cotton Braid 30 20 16 30 20 16 30 20 16 30 20 17 30 20 17 40 30 17 40 30 17 40 30 20 40 30 20 40 30 20 40 40 20 40 40 20 40 40 20 40 40 20 40 40 20 ^Nominal Finished Diam. Inches .190 .205 .225 .250 .280 .360 .380 .415 .440 .475 .535 .575 .620 .670 .730 Approx. Net Wgt. in Lbs. per 1000' 25 35 45 60 80 130 150 185 225 280 345 420 515 630 780 tScandard Shipping Length Feet 500'C 500' C 500' C 500'C 500' R 500'R 500' R 500' R 500' R 500'R 500'R 500' R 500'R Approx. Shipping Weight per 1000' 31 41 51 66 86 162 187 231 281 350 431 525 643 787 975 'Finished diameters given above are average. A tolerance of plus or minus S% i* etcessary due to variation in process of manufacture. tC--Coils, R--Reels 17 RBB 00488 ROCKBESTOS A.V.C. 600 VOLT SWITCHBOARD HINGE CABLE NEC TYPE AVB--ROCKBESTOS A.V.C. MAXIMUM OPERATING TEMP. 90C (194F) 1. STtANOCD TINNED COKM CONOWCTOI a 2. FELTED ASISSTOS < 3. VAINISHID CAMMIC 4. KITED AJIESTOS J. FLAMEMOOF COTTON IIAID FOR HINGE AND JUMPER CONNECTIONS ON SWINGING INSTRUMENT AND SYNCHRONIZING METER PANELS. MOTOR LEADS AND APPLICA TIONS SUCH AS LISTED UNDER TABLES B AND BS. As a companion wire to Rockbestos Switchboard Wire we offer this heat, flame and moisture resisting flexible Hinge Cable. Designed primarily for hinge or jumper connections on swinging instrument and synchronizing meter panels, etc., it is also used in various applications in electrical appara tus to maintain dependable performance. It may also be used for conduit wiring where conditions ate not severe enough to require an asbestos braid. Standard construction employs a flexible stranded, tinned copper conductor, insulated with a felted wall of asbestos, an insert of varnished cambric tape, another wall of felted asbestos, impregnated with flameproof and moisture resisting insulating compounds, and a cotton braid finished with flameproof I compound. Showing application of Rockbestos Table * The diameters of Rockbestos Hinge Cable are approximately the same as those of other Rockbestos Switchboard Wires, and braid finishes are identi BH 600 Volt Hinge Cable to swinging panel. cal to assure matching appearance when used on the same board. Rockbestos A. V. C. Hinge Cable is designated as National Electrical Code Type AVB, has a maximum operating temperature of 90C (194F) and is listed by the Underwriters' Laboratories. It complies with the NEMA Small Wiring for Switchboards Standard and is approved by Factory Mutual Laboratories, switchboard manufacturers and power companies. Standard finish colors: Gray and black. Authorized stock items: Gray. Be sure to specify braid color desired on or der. I TABLE BH 600 VOLTS TYPE AVB Size Stranding Tinned Bare Diam. Inches Nominal Thickness -- Mils 1st Felted Wall VC 1 2nd Felted Insert i Wall CoitOD Braid Nominal Finished Diam. Inches Approx. NecWgt. in Lbs. per 1000' ^Standard Shipping Length Feet Approx. Shipping Weight per 1000' * 18 AWG *16 14 12 10 8 16/.010 26/.010 41/.010 65/.01O 104/.010 133/.01U .045 .059 .075 .095 .120 .167 10 10 10 10 10 10 30 30 1! 15 I? 30 i 15 30 1 u 30 15 30 : 15 16 .190 16 .205 16 .220 17 .240 17 .265 17 .515 25 500'C 31 30 500'C 36 35 500'C 41 45 500' C 51 60 500' C 66 90 500'C 96 *Fimtbd diameter* liven above are sveufe. A tolerance of plus or minus 5% 1# necessary due to variation to process of manufacture. tC--Coils Not listed in National Electrical Code. % ie RBB 00489 ROCKBESTOS THERMOPLASTIC and ASBESTOS 600 VOLT SWITCHBOARD WIRES AND FLEXIBLE HINGE CABLE National Electrical Code Type TA TAEIE XB, SOLID--TABLE XBS, STRANDED TABU XBH, FLEXIBLE STRANDED HINGE CABLE MAXIMUM OPERATING TEMP. 90C (194F) t* a 1. SOLID OE STtANPED TINNED COME* CONDUCTOI 2. THERMOPLASTIC INSULATION 3. PELTED ASIESTOS ' FOR SWITCHBOARDS, CONTROL PANELS AND HINGE CONNECTIONS Standard finish colors: Gray and black. Authorized stock items: Gray. 4. PUMEPROOF COTTON IRAIO TABLE XB (Solid)600 VOLTSTYPE TA Size Bare DiaiD. Inches Minimum Thermoplastic Insulation Mils Nominal Thickness--Mils Felted Wall Cotton Braid ^Nominal Finished Diam. inches Approx. Net Wgt. in Lbs. per 1000' tSuodird Shipping Length Feet Approx. Shipping Weight per 1000' 18 AWG 16 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 .040 .051 .064 .081 .102 .128 .162 .182 .204 .229 .258 .289 .325 .365 .410 .460 20 20 20 20 20 20 30 30 30 30 30 40 40 40 40 40 20 20 20 20 20 20 25 25 25 25 25 30 30 30 30 30 TABLE 9 Size XBS (Stranded)600 Stranding Bare Diim. Inches VOLTS Minimum Thermoplastic Insulation Mils 16 16 16 16 16 17 17 17 17 17 20 20 20 20 20 20 Nom. Thickness -- Mils Felted Wail Cotton Braid .160 .170 .185 .200 .225 .250 .315 .335 .360 .385 .420 .480 .515 .555 .600 .650 20 25 30 40 55 75 120 145 175 210 260 330 405 495 605 750 500' C 500'C 500' C 500'C 500'C 500'C 500' R 500' R 500' R 500' R 500' R 500'R 500' R 500'R 500'R 500' R 26 31 36 46 61 81 150 181 218 262 325 412 506 618 756 937 ____ _____________ TYPE TA Nominal Finished Diam. Inches Approx. Net Wgt. in Lbs. per 1000" ^Standard Shippiog Length Feet Approx. Shippiog Weight per 1000' 18 AWG **l6 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 7/.0152 7/.0192 7/.0242 7/.0305 7/.0385 7/.0486 7/.0612 7/.0688 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 .046 .058 .073 .092 .116 .146 .184 .206 .232 .260 .292 332 373 419 .470 .528 20 20 20 20 20 20 30 50 30 30 30 40 40 40 40 40 20 16 .165 20 500' C 26 20 16 .180 25 500'C 31 20 16 .195 32 500' C 38 20 16 .215 41 500'C 47 20 17 .240 56 500'C 63 20 17 .270 79 500'C 85 25 17 -340 125 500' R 156 25 17 .365 150 500'R 187 25 17 .395 180 500' R 225 25 20 .425 240 500" R 300 25 20 .455 265 500' R 331 30 20 .525 345 500' R 431 30 20 .565 420 500'R 525 30 20 .610 515 500'R 643 30 20 .660 635 500' R 793 30 20 .720 780 500' R 975 TABLE XBH (Flexible Stranded) 600 VOLTS TYPE TA 18 AWG 16 14 12 10 8 6 5 4 3 2 1 0 00 000 , 0000 16/.010 26/.010 41/,010 65/.010 104/.010 133/.OUI 133/.0140 133/0158 I33/.0177 133/.01P9 133/.0223 259/.0180 259/.0202 259/.0227 259/.0255 259/.0286 .045 .059 .075 .095 .120 .167 .210 .237 .266 .299 .335 .378 .424 .477 .536 .601 20 20 20 20 20 20 30 30 30 30 30 40 40 40 40 40 20 16 .165 20 500' C 25 20 16 .180 :5 500' C 30 20 16 .195 31 500' C 3' 20 16 .215 42 500'C 47 20 1* .245 5' 500' C 63 20 17 .290 84 500' C 89 25 17 .365 130 500' R 162 25 20 395 160 500' R 200 25 20 .425 190 500'R 237 25 20 .460 230 500' R 287 25 20 .495 280 500' R 350 30 20 .570 360 500' R 450 30 20 .615 435 500'R 543 30 20 .670 535 500' R 668 30 20 .730 660 500' R 825 30 20 .*95 810 500' R 1012 lFinib<l diameter* given above are average. A (oieraoce of plua or minus i% ia neceitary due to variation in proceaa of manufacture. tC--Coils. R--Reels 'Not listed to Natiooal Eleerrical Code. RBB 00490 1 ROCKBESTOS AIL-ASBESTOS 600 VOLT RHEOSTAT WIRE National Electrical Code Type AIA MAXIMUM OPERATING TEMP. 125C (257F) % i. souo aum com* cokouctok a 3. nine asmstos I. ASMSTOS MAID FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES. INFRA-RED DRYERS, OVENS. ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD. Asbestos rheostat wire was originally produced by putting I two or three braids of asbestos yam on the wire and finishing each braid with compound. This had several disadvantages. For example, its moisture resistance was very low due to the comparatively open covering so that many engineers consid ered that spaced wiring was necessary in order to prevent possible leakage under damp conditions. The labor cost of doing this type of wiring is high. Another disadvantage--though really more of an annoyance --was that in working with this wire a good deal of the compound flaked off and continued to do so after the instil* lation was completed, spoiling the appearance of an otherj wise nice job. The Rockbestos development of the felted and impregnated wall of asbestos insulation was a distinct improvement. In stead of a relatively open covering on the wire, the asbestos is applied in the form of a homogeneous insulation. The dielectric strength is thereby increased. Next, the-impregnat ing compound is an integral parr of the insulating wall, not painted on after the wall is formed. That means that, through repeated heating and cooling cycles, the compound can never fail away from the asbestos. The dielectric strength and mois ture resistance of Rockbestos Rheostat Wire are, therefore, practically constant. And there is none of the usual flaking when working with Rockbestos Rheostat Wire and Cable, with either white or black braid. Because of its comparatively high moisture resistance Rockbescos Rheostat Wire may be bunch-wired with safety, and it is also recommended for open wiring carrying less than 600 volts which is subject to high temperatures or rotting, corrosive fumes. For a 300 volt construction of the same type refer to page 24. This wire is National Electrical Code Type AIA listed by the Underwriters' Laboratories as Type AIA wire and has a maximum operating temperature 125C (257F). Standard finish colors: Black and white. Authorized stock items: Black (white also in sizes nos. 6, 8, 10, 12 and 14. TABLE A 600 VOLTS TYPE AIA Size M8AWC ' iO $ 6 4 0 00 Bare Dam. Inches .040 .05! .004 .081 .102 .128 .102 .182 .204 .229 .258 .289 .525 .>65 .410 .460 Nominal Thickness--Mils Felted Wail Asbestos Braid 50 40 30 40 30 40 30 40 30 40 30 40 40 40 40 45 40 45 40 45 40 45 60 45 60 45 60 45 60 45 60 45 Nominal Finished Darn. Inches .180 .195 .205 -225 .245 .270 325 -355 375 .400 .430 .500 535 .575 .620 .670 Approx. NetWgc. in Lbs. per 1000' 22 26 32 42 56 79 115 140 165 205 255 320 395 485 600 745 tSuodard Shipping Length Feet 500' C 500' C 500'C 500' C 500' C 500' C 500' R 500' R 500' R 500' R 500' R 500'R 500'R 500' R 500'R 500'R Approx. Shipping Weight per 1000' 27 32 37 47 61 84 143 175 206 256 318 400 493 606 750 931 Finiihed diameters given above ait average. A tolerance of plu> or minui 5% it necessary due to variation in proem of manufacture. tC--Coils. R--Reels Nor listed in National Elecrrical Code. 20 RBB 00491 ROCKBESTOS ALL-ASBESTOS 600 VOLT POWER and RHEOSTAT CABLE National Electrical Cede Type AIA MAXIMUM OPERATING TEMP. 125C (257F) 1. ST1ANDEC PLAIN COPPf* CONDUCTOI la FtlTtD ASMSTOS 3 3. ASIESTOS IPAID FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES. INFRA-RED DRYERS. OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES. CORROSIVE FUMES. GREASE. OIL OR FIRE HAZARD. This wire is listed by Underwriters' Laboratories as Type AIA wire. Standard finish colors: Black and white. Authorized stock items: Black (white also in si2e$ nos. 12 and 14). For 300 volt construction refer to page 24, Table RF-300. Rockbestos High Temperature Rheostat Wire, TABLE R 600 VOLTS TYPE AIA Size Stranding Bare Diam. Inches Nominal Thickness -- Mils Felted Wall Asbestos Braid Nominal Finished Diam. Inches Approx. NetWgt. in Lbs. per 1000' -^Standard Shipping Length Feet Approx. Shipping Weight per 1000' 18 AWG 16 14 12 10 8 6 5 4 5 2 1 0 00 000 0000 250.000 CM 300.000 350.000 400.000 450.000 500.000 550.000 600.000 650.000 700.000 750.000 800.000 850.000 900.000 950.000 1.000.000 7/.0152 7/.0192 7/.0242 7/.0305 7/.0385 7/.0486 7/.0612 7/.0688 7/.0772 1'0867 7/.0974 19/.0664 19/.0745 I9/.0837 19/.0940 19/. 105 5 37/.0822 37/.0900 37/.0973 37/.1040 37/.1103 37/.1162 61/.095G 61/.0992 6I/.1032 61/.1071 61/.1109 61/.1145 61/.U80 6I/.1215 61/.1248 61/.1280 .046 .058 .073 .092 .116 .146 .184 .206 .232 .260 .292 .332 .373 .419 .470 .528 .575 .630 .681 .728 .772 .813 .835 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 30 30 30 40 40 40 60 60 60 60 60 75 75 75 75 75 90 90 90 90 90 90 105 105 105 105 105 105 105 105 105 105 40 40 40 40 40 40 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 .190 .200 .215 .255 .280 .310 395 .420 .445 .470 .505 .575 .615 .660 .710 .770 .845 .900 .955 1.000 1.045 1.085 U55 1.195 1.230 1.265 1.300 1-335 1.365 1.395 1.425 1.455 22 28 4u7 64 90 130 155 185 225 270 345 420 520 635 785 920 1080 1245 1405 1570 1730 1890 2080 2240 2415 2560 2730 2890 3050 3215 3375 500' C 500' C 500' C 500'C 500' C 500' C 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500'R 500'R 500' R 500' R 500' R 500' R 500' R 500'R 500'R 500'R 500'R "t t 33 39 53 69 94 162 193 231 281 337 431 525 650 793 981 1150 1350 1556 1756 1962 2162 2362 2600 2800 3018 3200 3412 3612 3812 4018 4218 Finished diameters givtti abovt *> average. A tolerance of plus or minus S% is necessary due ro variation in process of manufacture. tC--Coils. R--Reels **Not listed in National Electrical Code. 21 RBB 00492 ROCKBESTOS ALL-ASBESTOS 600 VOLT FLEXIBLE APPARATUS CABLE *v MAXIMUM OPERATING TEMP. J25C (257F) S II 1. FlfXIILf TINHtO comt CONOUCTOt 2. Flino AJMSTOS 3. AMESTOJ IUJ0 FOR FLEXIBLE LEADS AND CONNECTIONS OF APPARATUS SUCH AS LISTED UNDER TABLES "A" AND "R---OVENS. FUR NACES. DRYERS, AUTOMOTIVE BUS IMMERSION HEATER LEADS. BATTERY LEADS AND ENGINE COMPARTMENT WIRING. This cable is recommended wherever flexible leads or con nections must be used in open*wired high temperature installations. Steel mills sometimes use this cable for motor leads exposed to heat where the possibility of a moisture condition is re mote. it will not deteriorate under constant high ambient temperatures and is highly resistant to corrosive fumes, flame, grease and oil, characteristics which make ft ideal for jumper leads, etc. (For high dielectric strength and moisture resist ance see Rockbestos A.V.C. Motor Lead and Apparatus Cable on page 13.) 1 Automotive bus manufacturers and operators use it foe en- j gine compartment wiring and leads for batteries, crank case and radiator immersion heaters because of its high resistance to heat and flame. (For smaller diameter cable for these applications and diesel locomotive control circuit wiring in quire about special Type ACA engine compartment or con trol cables.) This cable is National Electrical Code Type AIA and is listed by the Underwriters' Laboratories' as Type AIA wire. Maximum operating temperature is 125C (257F). Stand ard finish colots: Black and white. Authorized stock item: Black- This cable an be made up with extra flexible stranded tinned conductor if tequired. For 300 volt construction refer to page 24, Table RF-300. TABLE RF 600 VOLTS TYPE AIA Size 1 Stranding Bare Diana. Inches Nominal Thi ckness-- Mils Felted Wall Asbestos Braid Nominal Finished Diam. Inches Approx. Net Wgt. in Lbs. per 1000' tStandard Shipping Length Feet Approx. Shipping Weight per 1000' IS AWG *16 14 13 10 8 6 5 ' i ; i i : : ; 16/.010 26/.010 41/.010 65/.010 104/.010 133/.01U 13 3/.0140 133/0158 .045 .059 .075 .095 .120 .167 .210 .237 30 30 30 40 40 40 60 60 40 40 40 40 40 40 45 45 .185 .200 .215 .255 .280 -330 .420 .450 23 27 34 49 65 94 135 165 4 i 133/.0177 3 : I33/.OI99 133/0223 1 : 259/.0180 .266 .299 335 .378 60 60 60 75 45 45 45 45 .460 .510 .545 .620 195 235 285 360 0 00 000 0000 i 259/.0202 : 259/.0227 . 259/.0255 . 259/.0286 .424 .477 .536 .601 75 75 75 75 45 43 45 45 .665 .720 .780 .845 445 540 665 810 230.000 CM ! 42V.0242 500.000 . 427/.0265 550.000 1 427/.0286 400.000 i 427/.0306 .653 .716 .772 .826 90 90 90 90 45 .925 985 45 .990 1120 45 1.045 1330 43 1.100 1460 450.000 500.000 1 427/.0325 427/.0342 .878 .923 90 90 45 1.150 1690 45 1.195 1805 500'C 500'C 500' C 500' C 500'C 500'C 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500'R 500' R 500'R 500' R 500' R 500' R 500' R 500' R ^7 32 39 54 71 99 168 206 243 293 356 450 556 675 831 1012 1231 1400 1662 1825 2112 2256 Finished diameters liven above are average. A tolerance of plus or minus 5% is necessary due to variation in procew of manufacture. +C--Coils. R--Reels Not listed in National Electrical Code. 22 RBB 00493 ROCKBESTOS ALL-ASBESTOS 300 VOLT EXTRA FLEXIBLE APPARATUS CABLE National ileetrltal Codo Type AA MAXIMUM OPERATING TEMP. 150C (302P) This cable was originally developed as "Motion Picture Cable" for specific use in motion picture projector lamp houses and sun-arc lamps, but its use has been extended to product and industrial applications requiring extra-flexible insulated conductors that will resist the baking effects of high temperatures. The felted asbestos insulation and the asbestos braid are both impregnated with heat and flame resisting compound to assure the highest possible resistance to heat and maximum flexibility. The braid finish is white. This cable is National Electrical Code Type AA, listed by the Underwriters' Laboratories as Type AA wire and has a maximum operating temperature of 150C (J02F). Strand ed Copper conductors employing No. 27 AWG or smaller strands limited to 150C (302F) by Underwriters' Lab oratories. It will remain flexible under continuous operation at rated temperature, doesn't bum or support combustion even when exposed to an arc, and has typical Rockbestos resistance to-fumes, grease or oil. Standard finish colors: White and black. Authorized stock items: White: TABLE W 300 VOLTS TYPE AA Size Stranding Bare Diam. Inches Nominal Thickness--Mils Felted Wall Asbestos Braid Nominal Finished Diam. Inches Approx. Net Wgt. in Lbs. per 1000' tStandard Shipping Length Feet Approx. Shipping Weight per 1000' *18 AWG 41/34 .047 30 40 .190 **16 14 65/34 .061 30 40 .205 104/34 .077 30 40 .220 12 259/36 .102 30 40 .245 30 41 10 8 6 4 413/36 .130 30 40 .270 58 665/36 .165 30 40 .305 75 1050/16 .205 40 45 3"5 115 1666/36 .275 40 45 .445 170 2 2646/36. .350 40 45 .520 255 1 3332/36 .400 60 45 .610 330 0 4214/36 .440 60 45 .650 410 00 5292/36 .500 60 45 .710 500 000 0000 6713/36 .570 60 45 .780 630 8512/36 .640 60 45 .850 780 500'C 500'C 500' C 500' C 500' C 500'C 500' C 250'C 200' C 200'C 200' C 200' NR 200' NR 200' NR 23 28 36 47 63 80 121 176 262 337 417 507 637 78? Finished diameter* given above are average, a tolerance of plus or minui SEfc ia necetaxrr due ro variation in process of manufacture. tC--Coils NR--Nonreturnable Reel*. Not lined in National Electrical Code. RBB 00494 23 6? rr ROCKBESTOS ALL-ASBESTOS 300 VOLT HIGH TEMPERATURE RHEOSTAT WIRE MAXIMUM OPERATING TEMP.: 200C (392F) -- TABLES A-300, R-300 150C (302F) TABLE RF-300 it t I. SOHO O* STlANPtO FIAIN COFFE4 CONDUCTORS J. tUTCO AU6STQ4 ati J. SlOS **10 FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES, INFRA-RED DRYERS. OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD. CONDUCTORS: TABLE A-300 (SOLID) TABLE R-300 (STRANDED) TABLE RF-300 (FLEXIBLE STRANDED) These wires are listed by the Underwriters' Laboratories as Type AA wire. Standard braid finishes are white and black---colors on special order. TABLE A-300 (Solid) 300 VOLTS TYPE AA Size **18 AWG '16 14 12 I 8 Bare Diam. Inches .040 .051 .064 .081 .102 .128 ! Nominal Thickness -- Mils j Felted | Wall i Asbestos j Braid ` 30 1 40 ! 30 40 11 3300 i 40 i 40 : 50 40 i 30 1 40 'Nominal j Approx. Finished i Net Wgi. Diam. J in Lbs. Inches 1 per 1000' .180 .195 .205 .225 .245 .270 ! l j | i 18 22 28 38 52 69 tStandard Shipping Length Feet 500'C 500'C 500'C 500'C 500'C 500' C | Approx. : Shipping Weight : per 1000' : 22 ! 28 33 > 45 . 57 79 Finished diameter* given above are average. A tolerance of plot or minus s% is necessary due to variation in process of manufacture. tC--Coils TABLE R-300 (Stranded) Size i,, . Bare Diam. Stranding Inches IS AWG 16 14 12 10 8 7/.0152 i .046 7/.0192 ! .058 7/.0242 \ .073 7/.0305 ! .092 7/.0385 i .116 7/.0486 ! .146 300 VOLTS TYPE AA Nominal Thickness -- Mils ! 'Nominal i Approx. tStandard i Approx. ------ Finished ; NetWgt. Felted J Asbestos > Diam. Wall Braid Inches 1 per 1000' Feet per 1000' 30 ! 40 ; .190 ' 50 j 40 30 i 40 .200 .215 : I 30 ' 40 ' .235 1 50 ! 40 i .260 1 30 40 .290 i 18 1 500' C 25 1 500'C : 29 1 500' C ' 44 j 500' C 54 1 500' C 72 500' C : 24 28 35 45 60 83 TABLE RF-300 (Flexible Stranded) 300 VOLTS (Maximum Operating Temp. 150C) TYPE AA *`18 AWG *'16 14 i: 10 s 16/.0I0 26AOIO 41/.010 M/om 104/.010 133 '0 til ' . .045 .059 .075 .095 .167 30 40 30 40 50 40 50 : .io 30 40 30 ; 40 .185 .200 .215 .235 .260 .307 ; 1 ' i 1 IS 500' C 23 ' 500' C 40 ' 500' C 40 500' C 56 ' 500' C 75 p 500' C Fmijhed diameter* given above are average. A tolerant* of plua or minus Not luted m National Electrical Code. <i neeetsiry due to vitiation in proem of manufacture. +C--Coili 24 28 35 46 61 88 24 RBB 00495 ROCKBESTOS ALL-ASBESTOS 300 VOLT FIXTURE WIRES Noflona/ Electrical Code Type AF MAXIMUM OPERATING TEMP. 150C (302F> WHITE ASMSTOS INSULATION IACX AMESTOS INSULATION SOLID COLOR (RAID SOLID COLOR (RAID WITH MARKER FOR LIGHTING FIXTURES, SUN LAMPS, OFFICE EQUIPMENT, RADIO APPARATUS, LEADS FOR SMALL MOTORS AND TRANS FORMERS, MINIATURE SWITCHBOARDS, ETC. These heat resisting fixture wires are used for lighting fix tures, sun lamps, office equipment, radio apparatus, leads fot small motors and transformers, miniature switchboards, etc. They are approved by the Underwriters' Laboratories for lighting fixture wiring and bear their labels. For fixtures where the wiring is concealed in stems or brack ets, the PLAIN type wire is recommended. It has no braid. Made in blade and white to indicate polarity. When wiring is exposed, such as on a chain pendant fixture, ie BRAIDED wire is recommended. Made in solid color raids and solid color with marker thread to indicate polarity. ORDERING INFORMATION Standard Packing: Both plain and braided fixture wires are put up on metal spools and in coils, and where quantity warrants (5000 to 10,000 feet depending on size) on fac tory reels. Rockbestos plain fixture wire is furnished in standard colors, black, white and ted. Green, yellow, gray, orange and brown can be furnished to order. Authorized stock items: Black and white. Rockbestos braided fixture wire is finished in standard colors, mahogany brown and black in glazed cotton. Other colors and polarity marker threads can be furnished to order. In ordering specify: A.W.G. size and stranding. Whether plain type or braided type. If plain whether half the order black, other half white finish, or all one color. If braided type, whether half order solid color braid, other half with marker or all one way. Color of braid. TABLE FS Size i t | 18AWG | 16 ! 14 : 12 . 10 iplain) Stranding 16/30 26/30 41/30 65/30 104/30 Bare Diam. Inches .045 .059 .075 .095 .120 300 VOLTS Min. Felted Wall Mils ] -Nominal i Finished [ Diameter i Inches 31 j .110 31 ! .125 31 1 .140 47 : .190 47 i .210 Approx. Net Wgc. in Lbs. per 100O' 10 14 20 34 48 ^Standard Shipping Length Feet 500' S 500* S 500'S 500' S 500' C TYPE AF Approx. Shipping Weight per 1000' 12 l? 25 37 51 TABLE FSB (BRAIDED 300 VOLT TYPE AF 18AWG : 16 14 12 ` 10 16/30 26/30 41/30 65/30 104/30 .045 .059 .075 .095 .120 31 1 .140 31 . .155 31 : .170 47 i .220 47 i .240 12 500'S 14 16 500'S 19 22 500' S 25 37 500' S 40 52 500' C 55 Fmijhed diameters given aBnve are avenge. A tolerance ( plus ot minus 5Cr it necessary 4u to vitiation U process of manufacture. tC--Coils. $--Spools RBB 00496 25 27 RBB 00498 ROCKBESTOS A.V.C. 600 VOLT MINING CABLE MAXIMUM OPERATING TEMP. U0C (230F) 4 >* I. FLEXIBLE TINNED COFFEE CONDUCTOI 2, FELTED ASIESTOS 1 1. VAENLSMED CAMEEIC 4. FELTED ASMSTOS 1 ASBESTOS ItAIO FOR ALL INTERNAL CIRCUITS Of ELECTRIFIED MINING EQUIPMENT This original Rockbestos A.V.C Mining Cable was designed to meet requirements for a cable that would operate depend ably under the unusual conditions prevailing in the mining industry and is not a National Electrical Code Standard. Similar in construction to Rockbestos A.V.C. Motor Lead Cable, but made to diameters that fit equipment bushings properly, its impregnated felted asbestos insulation and heavy asbestos braid withstands conductor-heating overloads and the heat of resistor grids in the tightly sealed compart ments of permissible equipment. It won't burn or carry flame. won't bloom, rot or flow under exposure to grease or oil, and has ample resistance to moisture and the destructive action of alkaline water. Standard of leading mining machine manufacturers for de pendability and safety since 1928, it is widely used by mine electricians to keep equipment in full-time operation and reduce maintenance. NOTE: This cable is not designed or intended for use as drag or reel cable. To avoid error specify Table ML, Rock bestos A.V.C. for use in cutters, loaders and locomotives. Standard finish colors: Black and white. Authorized stock item: Black. TABLE ML 600 VOLTS Size Stranding Bare Diam. Inches Nominal Thickness -- Mils 1st Felled Wall VC Insert 2nd Felted Wall Asbestos Braid Maximum Finished Diam. Inches Approx. NetWgt. in Lbs. per 1000' 14 AWG 41/.010 .075 10 40 10 27 1/2 .273 40 12 65/.010 .095 10 40 10 27 1/2 .294 51 10 104/.010 .120 10 40 10 27 1/2 .313 6i S 133/.01U .167 10 40 10 27 1/2 359 95 6 133/.0140 .210 10 40 5 I33/.OI58 -237 10 40 4 I33/.0177 .266 10 40 3 133/.0199 .299 10 40 10 27 1/2 .405 10 27 1/2 .428 10 35 .473 10 35 .506 135 160 195 235 2 133/0223 .335 10 40 10 35 1 259/.0180 .378 15 40 15 45 0 259/.0202 .424 15 40 15 45 00 259/.0227 .477 15 40 15 45 .546 .620 .669 .716 285 370 450 550 000 259/0255 .536 15 40 15 45 .779 675 0000 259/0286 .601 15 40 15 45 .849 825 250.000 CM 427/.0242 .653 20 40 40 45 .988 1020 300.000 427/.0265 .716 20 40 40 45 1.056 1195 350.000 400.000 450.000 427/0286 427/0306 427/.0325 .772 .826 .878 20 20 20 40 40 40 40 45 40 45 40 45 1.115 1.172 1.226 1370 1545 1730 500.000 427/0342 .923 20 40 40 45 1.274 1895 "Minimum diameter *2*/j<7c of maximum diameter. *C--Coil*. R--.Reel* tStandard Shipping Length Feet 500'C 500' C 500'C 500' C 500' R 500' R 500' R 500' R 500'R 500' R 500'R 500'R 500'R 500' R 500' R 500' R 500'R 500'R 500' R 500' R Approx. Shipping Weight per 1000' 45 56 72 100 168 200 243 293 356 462 562 687 843 1031 1275 1493 1712 1931 2162 2368 26 RBB 00497 ROCKBESTOS TYPE ACA 1000 VOLT LEAD and HOOKUP WIRES TABLE EMA 1000 VOLT LEAD WIRE MAXIMUM OPERATING TEMP. 90C (194F) <mmhi..hrw STRANDED TINNED COPPEK SYNTHETIC TAPES FELTED ASIESTOS GLAZED COTTON HAID.UCOUEI FINISH This 1000 Volt ACA Lead Wire had its inception in appli cation wiring with the advent of cold cathode--slim line-- and mercury vapor fixtures where the initial starting voltages exceed 300 volts, thereby eliminating the use of 300 Volt AT Wire. It had a distinct advantage in its small diameter. Because of this feature, it has also found usage in some in dustrial instrumentation and control circuits in conduit when its use does not conflict with the requirements of the National Electrical Code. Additional uses for this wire are foe automotive bus engine compartment wiring and diesel locomotive circuit wiring. Rockbestos 1000 Volt Lead Wire is constructed with non flowing, thin-walled, helically applied synthetic tape and felted asbestos insulation. This construction covered with a glazed cotton braid lacquer finish results in a small diameter wire with high dielectric strength. This wire strips easily and is resistant to heat, cold, flame, moisture, grease and oil. TABLE ZM 1000 VOLT HOOKUP WIRE MAXIMUM OPERATING TEMP. 125C (257Is) stranded TINNED COPPER synthetic TAPES felted ASIESTOS lacquered CLASS IIAID Here is a Hookup Wire which has developed many product and electrical maintenance applications. It is similar in con struction to the 1000 Volt Lead Wire shown on this page with the exception that it is covered with a lacquered glass braid overall and is recommended for applications in which abrasion resistance requirements are less severe than for Table EMA. This hookup wire was originally developed along govern ment specifications for a glass braided wire suitable for use within electronic devices and instruments which would have high dielectric strength, small diameter and stability in a broad range of operating temperatures. Like Table EMA on this page, Rockbestos 1000 Volt ACA Hookup Wire is resistant to heat, cold, flame, moisture, grease and oil. It can be terminated easily because it strips cleanly and withstands the heat of soldering. This wire can be color coded as illustrated bv the use of colored tracers inserted in the white glass braid. TABLE EMA (cotton braid) 1000 VOLTS | Stranding Size 14 AWG | 19/0142 12 1 19/.0179 i Bare Diam. Inches 071 .090 Nom. Thickness--Inches Svmheuc Tape Felted Wall Braid Thickness .010 .010 .020 .020 .0125 .0125 TABLE ZM (GLASS BRAID) 1000 VOLTS 'Nominal Finished Diam. Inches .156 .175 Approx. Net Wgt. in lbs. per 1000' 23 31 TYPE ACA tStandard Shipping Length Feet Approx. Shipping Weight per 1000' 500' C 500' C 28 36 TYPE ACA 18 AWG 16 14 12 10 j 16/.010 26/.010 41/.010 65/010 104/.010 .045 .059 .075 .095 .120 .0065 .0065 .010 .010 .010 .0085 .0085 .0085 .010 .010 .0075 .010 .010 .010 .010 .090 .109 .132 .155 .180 8 *1000' 12 '*1000' 19 **1000' 28 **1000' 42 *1000' 'Finished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variations in process of manufacture. +C--Coils. **Non*Rerurnabie reels or metal spools 12 16 23 32 48 27 RBB 00498 ROCKBESTOS A.V.C. Aftft wrst T U1MIMA ROCKBESTOS THERMOSTAT CONTROL WIRE l. CMAMCLCO corn* CONBUCTO* 3- fOlAIUEO mtlD AJWSTOS 3. COATED STEI1 AKMOK FOR LOW VOLTAGE SIGNAL, INTERCOMMUNICATIONS AND ALARM SYSTEMS, FUEL BURNER CONTROLS, GAS BURNER SAFETY PILOTS, OVENS, HEATERS, FURNACES, INDUSTRIAL DRYERS, AIR CONDITIONERS, APPARATUS, ETC. The wiring of the control systems of early automatic coal and oil burning installations formerly gave frequent trouble. To get shcit runs it was often installed dos* to, ot actually resting on, hot water or steam pipes and the heat naturally deteriorated ordinary insulated wire to the point where trou ble frequently occurred. Cases are on record where serious damage has resulted from faulty control wiring. Abrasion, too, has always been a source of trouble when fish ing ordinary control wire, particularly in buildings already up. Sharp corners, brickwork, plaster, protruding nails and rough beams all tend to damage the insulation. With these conditions in mind, and with the wide adoption of automatic fuel burning systems, a large manufacturer of heat control apparatus asked us to design a wire which would be heatproof and abrasion resisting--and Rockbestos Ther mostat Control Wire was the result. Rockbestos Thermostat Control Wire is very sttong mechan ically because of its firm felted asbestos insulation and its rugged, abtasion resisting spiral steel armor or metal braid. It is heatproof and will not dry out under heat or with age. It eliminates fire hazard because it cannot burn. Neicher can tats damage it as has been known to happen occasionally with unprotected wires. Where resistance to abrasion or protection against rodents is not essential, a cotton braid may be speci fied instead of metallic sheath. With these advantages it is of value for control and intercommunicating systems or for any similar application where a low voltage, multi-conductor cable is required. Rockbestos Thermostat Control Wire is designed to be useJ at low voltages, usually fed by a step-down transformer. For this application the 12 i/2 mil wall insulation is generally used, rfowever, some users prefer the 25 mil insulation thick ness for its added mechanical and dielectric strength. Where this cable is to be used direct on 115 vole circuits a minimum insulation thickness of 31 mils is recommended. Data for cables with all three insulations is listed in the table below. Noth: The metal braid covering mentioned in the fourth paragraph is an optional suggestion. TABLE TC 127* mil. TABLE TCC 25 mil. TABLE TCS 31 mil. Nominal Wail Thickness Finished Diameters* (Inches) Size A.W.G. Number of For Low Voltage Service Conductors 115 Volt Service 12V2 Mil O. D. 25 Mil O. D. 31 MU O. D. 16 2 16 3 16 4 16 5 18 18 3 IS 4 18 5 .175 .185 .210 235 .155 .165 .180 .205 .225 .240 .270 .305 .205 .215 .240 -275 .265 .285 .315 .355 .245 .260 .290 .325 Approximate Weights per M Feet (Pounds) For Low Voltage Service l2'/j Mil 25 Mil 115 Volt Service 31 Mil Net Ship. Net Ship. Net Ship. 35 41 43 49 47 53 46 52 56 62 62 68 58 64 69 75 79 85 69 75 84 90 97 106 26 30 34 40 37 43 34 39 43 49 49 55 43 49 53 59 61 67 50 56 64 70 75 81 Finished diameters given above ate average. A tolerance of plus or minus i% is necessary due to variation in process of manufacture. Standard Shipping Lengths (Feet) Coils 500 500 500 500 500 500 500 500 28 RBB 00499 ROCKBESTOS INDUSTRIAL HEATING CABLES # TABLE LH MAXIMUM LEAD SHEATH TEMP. 350F. TABLE LHV MAXIMUM LEAD SHEATH TEMP. ldS'F. U-L. Approved by report for pipe heating applications SPECIAL ALLOY WIE FELTED ASSESTOS LEAD SHEATH SPECIAL FELTED AHOY Wl ASSESTOS VAINISHED CAA.M/C lEAO SHEATH FOR THE CONTROLLED DISTRIBUTION OF MILD HEAT TO PREVENT FREEZING OF WATER, WASTE PIPES, EAVES TROUGHS, DOWN SPOUTS AND VALVES--TO INSURE FLOW OF VISCOUS FLUIDS, OILS, PAINT, CHOCOLATE. ETC. This Rockbestos heating cable was originally developed to force the growth of early spring plants in hothouses. After its introduction to florists, market gardeners and amateur horticulturists, it found its way into industry as a useful heat source for the distribution of even mild heat. It performed to better advantage and more economically than spot or strip heaters. Pliable, easily bent and formed, it can be threaded through apertures or made to conform to irregular shaped objects. It is best used wrapped around pipes and cov. ered with a good standard pipe insulation for greatest economy. We can only touch on a few typical applications to which our customers have put this heating cable, but they will give you a good idea of the varied uses to which it has been put. in many plants the cable is used as a safeguard against frozen water pipes making unnecessary the rearrangement of piping or costly replacement. Waste pipes, eaves troughs and down spouts can also be kept free and clear of ice. Paint, soap, varnish, ink, chocolate, molasses and sulphur, to name a few, can be kept at fluid temperatures insuring against irregular flow and clogged conveyor pipes. Wet pipe sprinkler systems located in unheated areas are easily heated and kept at non-freezing temperatures that assure positive operation. Steel nulls use it around roll-necks to prevent rhe lubricant from congealing and a utilities'engineer wound the cable around the pipes connecting the conservator tank to the main tank of a conservator type transformer, covered it with lagging, and eliminated congealing of oil and freezing of condensate. The resistance of Rockbestos Industrial Heating Cable is approximately 0.5 ohms per foot. In order to keep the temperature low enough so that the insulation will not be injured, the generally recommended length across 115 volts, is 60 feet. The recommended wattage limit is 7 watts per foot. At 110 volts a 60 ft. length is rated at 400 watts, 6.66 watts per ft. Across 220 volts use a 120 ft. length for the same current value and double the total wattage. Caution-. Do not use Table LH where maximum voltage exceeds 120 volts to ground. Table LHV is suitable for 440 volt service in 240 foot lengths and is U.L. approved by report for pipe heating applications. When installed permanently, Rockbestos Industrial Heating Cable should be cov ered by some form of heat insulating material for operating economy. Precise temperature control is established by means of a low piiced thermostat available from a number of manufacturers. We will be glad to refer you to several. The characteristics of this particular heating cable are given simply because it is a standard product and usually available from stock. We are equipped, however, to make up heating cable characteristics to your specification. Furnish complete details concerning temperature desired, heat dissipation, etc. with inquiry. In applications where this cable is used close to physi cal contact with personnel, the lead sheath should be grounded. Other industrial heating cables are shown on the follow ing page. Typical installation of industrial beating cable to pipes using insulation and thermostat for precise temper ature control. TABLE LH and LHV Table Approx. A.W.G. Size Conductor Bare Diam. Inches Approx. Resistance Ohms per Ft. ; 1 ; Nom. Thickness Insulation Mils Lead Sheath Inches Nominal Finished Diam. Inches Approx. Net Wgt. in Lbs. per 1000' Standard Shipping Length Feet Shipping Weight in Lbs. per 1000' LH LHV 19 Nickel .034 Chrome Iron 19 Nickel .0*4 Chrome Iron 5052 j 40--Asbestos 5/64 .5052 . 21--Varnished Cambric 5/64 .215 .240 143 60, 120 and 240 ft. lengths and in bulk 160 on Reels Finished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variation in process of manufacture. 178 on Reels 200 on Reels 29 rBB 00500 ROCKBESTOS SPECIAL INDUSTRIAL HEATING CABLE TABLE LHT TABLE LHG 4 * THESE ROCKBESTOS HEATING CABLES ARE TYPICAL OF THE SPECIAL CONSTRUCTIONS DEVELOPED TO MEET THE SPECIFIC REQUIREMENTS OF OUR CUSTOMERS. THEY ARE SHOWN ONLY TO ILLUSTRATE VARIED CONSTRUCTIONS SUCCESSFULLY DEVELOPED FOR INDUSTRIAL AND PRODUCT USES WHERE THE APPLICATION OF A CONTROLLED HEAT SOURCE WAS NECESSARY. CONSTRUCTION 1. Special Alloy Wire 2. Felted Asbestos 3. Teflon Tapes 4. Felted Asbestos 5. Lead Sheath Here is a special lead sheathed heating cable designed to solve a problem in the manufacture of refrigeration units. The problem was to speed the time required in the deicing cycle without appreciable temperature rise in the cold cham ber. The answer here was to design a heating cable suitable for higher voltage operation than our Table LH industrial heating cable shown on page 29. This heating cable con struction has successfully solved this problem. It is suitable for 440 volt service and has a maximum Sheath tempera ture of 350F. CONSTRUCTION 1. Special Alloy Wires 2. Felted Asbestos 3. Teflon Tapes 4. Felted Asbestos--Silicone Treated 5. Glass Braid--Silicone Treated Along with the trend toward outdoor power plants came the need for protecting high temperature steam and gage lines from freezing during shutdown periods. Rockbestos Field Engineers called in to study this problem designed this special construction to be applied between the layers of pipe insulation. This provided an ideal solution as the sili cone treated insulation and silicone treated glass braid con struction withstood the high temperatures developed during the normal operation of steam lines and when steam lines were not operating provided a heat source of sufficient temperature to keep the condensate from freezing. This heating cable is rated at 440 volts and has maxi mum operating temperature of 500F. Rockbestos Heating Cable Designs can be developed :o solve your electrical hearing problems--furnish complete data cov ering temperature desired, heat dissipation, etc. with vour inquiry. 30 RBB 00501 ROCKBE5TOS HEATING CABLE KITS and THERMOSTATS ROCKBESTOS HEATING CABLE KITS for Roof De-icing--Pipe Heating and Sail Heating Applications FOR THE HOME-ON THE FARM- (N MOBILE HOME PARKS Available in 3 Handy Sizes: 60 ft. kit (30 ft. loop)--460 watts 40 ft. kit (20 ft. loop)--260 watts 20 ft. kit (10 fc. loop)---130 watts Complete instructions with each kit. operate on 110-120 volts AC or DC THESE LEAD SHEATHED HEATING CABLES WITH FLEXIBLE NON-HEATING CONNECTOR PERMIT: Repeated "plug-ins" without damage to the cable Unlimited uses thru weatherproof construction Bectec heat conductivity than non-metal sheaths Easy application to irregular shaped objects A COMPLETE UNIT ready to plug into any standard 110-120 volt AC or DC outlet ROOF DE-ICING: This cable serves as a source of mild heat to prevent che formation of ice dams which cause destructive leaks on building or house roofs, including gabled roofs. The current is turned on only when rain or snow is expected and the temperature drops below freezing. The kits come in 20, 40 and 60 ft. lengths (the latter com plete with 8 shingle damps), depending upon the overhang of the eaves. With average house construction one 60 ft. kit will protect 20 running feet of roof. PIPE HEATING: Electric heating cable can easily be applied to water pipes, whether buried in the ground or exposed, to give positive protection against the damage caused by freeze-ups or broken pipes. For maximum coverage of pipe length, the cable should be applied parallel; but where greater protection is needed in low temperatures, the spiral method can be used. When applied this way, the cable will increase the heat applied because of the greater concentration of heat. SOIL HEATING--HOT BEDS and COLD FRAMES: The heating kit serves as a dependable heat source in hotbeds, cold frames and propagating benches to stimulate faster growth for plants and cuttings. Cuttings will root and plants will grow 20 to 30 times faster this clean scientific way. Once the cable is installed, it may be left in place indefinite ly. To insure proper seed germination a thermostat is necessary to accurately control the heat. For this purpose we recommend using Rockbestos Weatherproof Thermostat LT-56 adjustable for temperatures of \0T00F. ROCKBESTOS WEATHERPROOF THERMOSTAT LT-56--with Pilot Light Indicator Automatically Controls Temperatures in Electric Heating Cable Kits for Maximum Economy in Power Consumption Quickly installed Automatic protection Multiple control PIPE HEATING APPLICATIONS: The thermostat should be mounted directly on the pipe itself, selecting the coldest spot along its length. Five feet of cord leading from the thermostat U provided for connection to a 110-113 volt AC power source. Secure the thermostat to the surface of the pipe with a suitable wire or cord, passing it through the small "ears" on either side of the thermostat. Simply plug the thermostat cord into your power source and plug the heating cable into the back of the thermostat plug When pipe covering is used, extend pipe covering to cover thermostat, leaving only dial exposed for setting. Set the thermostat for the temperature at which heating is to start (approximately 37F. for pipe heating) and thermostat is ready to operate. HOT BEDS. COLD FRAMES or PROPAGATING BENCH APPLICATIONS: The thermostat may be mounted within the frame itself when air temperature control is all that is requited. When used to control soil temperatures, the thermostat itself may be buried, allowing the dial and setting knob to be exposed for final dial setting. The weather-proof construction provides protection against moisture encountered in wetting che soil at required in tervals. . SPECIFICATIONS Ratme Temperature Range 15 amps on 115 volts AC }05F to 100CF maximum Cord Length 3 feet from outlet to thermostat Thermostat Construction Weather proof moulded plastic enclosure Pilot Light Built into thermostat plug--light glows when heating cable is calling for heat. CAUTION: Do not install with cable touching itself in any application RBB 00502 31 STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES Many companies have requested suggestions for a standard specification to aid them in the ordering of Rockbestos wires and cables. The following specification has been formulated for that purpose and covers Rockbestos A. V. C. and AU-Asbestos constructions described in this catalog. NOTE: This specification is in accordance with the requirements of the National Electrical Code and the National Electrical Manufacturers Association Standards for Asbestos and Asbestos-Varnished Cambric Insulated Wires and Cables with which all Rockbestos wires and cables of standard construction comply. I General (a) Purpose: The purpose of this specification is to insure the furnishing of wire and cable of the proper quality, manufactured in accordance with accepted practice. (b) Scope: This specification covers the construction and test requirements for asbestos-varnished cam bric and all-asbestos insulated wires and cables. (c) Materials and Workmanship: AU materials and workmanship employed in manufacturing wires and cables to this specification shall be of high quality so as to provide a finished product best suited for the purpose intended. (d) Applications A.V.C. Insulations. These wires and cables are suitable for operation at the specified voltages in either open or con duit installations in locations where they must operate under both heat and casual moisture con ditions. If wire or cable is to be installed where it may operate under excessive condensation conditions or be submerged, lead sheathed type should be specified. All-Asbestos Insulations. These wires and cables are suitable for operation at the specified voltages as exposed wiring in high temperature locations where little or no moisture is encountered. II Conductors (a) Solid: Solid conductors shall be either plain, tinned or lead alloy coated copper in accordance with current ASA or ASTM specifications. (b) Stranded: Stranded conductors shall be bunched, concentric or rope lay as required, The make-up of stranded conductors shall conform to current ASTM specifications. The individual strands shall be as specified for solid conductors in 11(a). (c) Conductors other than copper shall be specified to meet individual requirements. III Insulation (a) Asbestos 1. Material: The asbestos insulation shall consist of selected quality, long fibre, chrysotile asbestos commercially free from foreign particles of dirt, cotton seed and metallic oxides. It shall be well carded to prevent lumps and irregularities in the finished wire or cable. The asbestos insulation shall be applied to form a smooth, felted wall of uniform thickness as specified in the tables. The asbestos insulation after extraction of the impregnating compound shall contain not less than 80% by weight of asbestos. The total iron content shall not exceed 4% by weight of the asbestos. 2. Impregnation: The asbestos insulation shall be dried and saturated with a flame and heat resisting compound or a flame, heat and moisture resisting compound as specified. The compound shall consist of suitable high grade ingredients and shall retain its initial qualities during the normal life 0 & 32 RBB 00503 STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES 9 (b) 1. 2. of the wire or cable. The compound shall develop no injurious chemical action within itself or with any component parts of the wire or cable. Varnished Cambric Material'. The varnished cambric insulation, when used, shall consist of a high grade varnished doth substantially free from blisters or other imperfections. Application-. The varnished cambric shall be applied with lubricating compound between layers and to the wall thickness specified. IV Separators Unless otherwise specified, suitable separators may be used over the conductor or between component layers of insulation. V Braids (a) Asbestos 1. Material: The asbestos yarn shall be of selected quality, long-fibre, chrysotile asbestos contain ing not less than 80% by weight of asbestos. The total iron content shall not exceed 6% by weight of the asbestos. 2. Application-. Asbestos braids shall be applied to conform to current NEMA standards. 3- Finish: Asbestos braid shall be finished with a suitable flame and heat resisting compound or sat urated and finished wdth a flame, heat and moisture resisting compound as specified. (b) Cotton Marker Braids for Multi-Conductor Control Cable Marker braids shall comply with the current requirements of ASA specification for Cotton Braid for Insulated Wire and Cable for General Purposes--Code Braids (commonly known as NEMA Class A braid). (c) Finished Cotton Braid for Outer Covering 1. Finished braid shall comply with the current requirements of ASA specification for Cotton Braid for Insulated Wire and Cable for General Purposes--Standard Braids (commonly known as NE MA Class B braid). 2 This cotton braid shall be finished with a flame and heat resisting compound oc saturated and finished with a flame, heat and moisture resisting compound as specified. VI Metallic Coverings Coverings such as lead sheath, spiral, basket weave and interlocking armor, when required, shall com ply with current NEMA specifications for metallic coverings. VII Cabling (a) For cables consisting of more than one conductor (except flat twin cables) the individually insu lated conductors shall be concentrically cabled together. The lay of the conductors in each layer shall not exceed 16 times the pitch diameter of that particular layer. The direction of lay of the conductors in each successive layer shall be reversed. (b) Where circuit identification is required it shall be accomplished by coloring the insulation or by the use of marker braids. (c) When required, fillers shall be used and shall be of jute or asbestos, drv or impregnated with a moisture resisting compound. (d) In cables with coded conductors or w'hen required for manufacturing reasons, a tape shall be ap plied over the cabled conductors. VIII Tests A. Physical a 1. Dimensions-. Inspection for dimensional requirements shall consist of four determinations, two to 33 RBB 00504 STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES be made near each end of the sample of which the average shall comply with the requirements giv en in the tables. The measurements of cable % inch diameter and smaller shall be made with a ratchet micrometer having 14 inch diameter faces. For cable larger than % inch diameter the meas urement shall be made with a circumference tape. Each determination, when made with a micro meter, shall be the average of two measurements made at right angles to each other. 2. Resistance to Flame-. All wires and cables made to this specification shall have fire resisting prop erties so that the test specimens will meet all of the requirements of the Underwriters' Laboratories standard vertical flame test. B. Electrical 1. Initial Dielectric Strength (a) Single Conductor. Initial dielectric strength tests shall be made on 5-foot lengths of finished wire or cable with the center 3-foot section wrapped with metal foil. Voltages as indicated in the tables shall be applied for 5 minutes on wire or cable rated 600 volts or over, and for 1 minute on wire or cable rated 300 volts. (b) Multi-Conductor-. Initial dielectric strength tests shall be made on full reel lengths of finish ed cable by applying 2^ times rated voltage between each conductor and all others for 5 minutes. Also an initial dielectric strength test shall be made on 5-foot lengths of finished cable, with the center 3-foot section wrapped with metal foil. Voltages as indicated in the tables shall be applied between each conductor and all others and metal foil, and between all conductors and metal foil, for 5 minutes on cable rated 600 volts and over, and for 1 minute on cable rated 300 volts. (c) Metallic Covered Cable-. Initial dielectric strength tests shall be made on full reel lengths of metallic covered cable by applying 21/2 times rated voltage between conductor and covering on single conductor cable, and between each conductor and other conductors and the metallic covering on multi-conductor cable for a period of 3 minutes. 2. Dielectric Strength After Flame (a) A sample of wire or cable having been previously subjected to the flame test shall be prepar ed with the charred area of sizes No. 6 and larger wrapped in metal foil, and sizes smaller than No. 6 buried in iron filings or fine shot. Test voltages applied for 1 minute shall be as follows: (1) Asbestos-varnished cambric insulated wires and cables rated at 600 volts or more, U/2 times rated voltage. (2) All-Asbestos insulated wires and cables rated at 600 volts, 21/2 times rated voltage. (3) 300 volt rated wires and cables, 1000 volts. 3. Dielectric Strength While Immersed A 5-foot sample of finished wire or cable having flame, heat and moisture resisting finish shall have the center 3-foot section immersed for 1 hour in tap water at room temperature, and while still im mersed shall withstand a dielectric test of 2 times rated voltage applied between conductor and water for 1 minute. IX Sampling (a) Each of the required tests shall be made on one sample of each size and type of wire or cable from each lot of 10,000 feet or fraction thereof. (b) If a sample fails to meet a prescribed test requirement, two additional samples shall be taken from the same length. If the two additional samples meet the test requirement then the lot shall be accepted. If either of these samples fail the length may be rejected. (c) If any length is rejected for failure to meet a requirement, then a sample shall be taken from each length of the balance of the lot and subjected to the particular test requirement to determine acceptance or rejection of that length. ^ ' 34 RBB 00505 SWITCHBOARD WIRES and FULL REEL TESTS Type Page SPECIAL TESTS FOR SWITCHBOARD WIRES (IPC6A Standard 5-28-357) (NIMA Standard WC-t-551 Des crip tion Rated Voltage Initial Dielectric Tests Period Test potentials (KV) to of Test be applied to sizes Voltage 18-8 6-2 M/0 Minutes AWG AWG AWG Standard Flame Resistance Test NEMA AVC 6-788 Dielectric Failure Test NEMA AVC 6-80D1 Leakage Resistance Bend--Dielectric Test Test NEMA AVC 6-80D2 NEMA AVC 6-80DA AVB 17 Switch- 600 5 3-0 4.0 4.0 board Wire AVB 18 Hinge 600 5 3-0 -- -- Cable TA 19 600 3-0 4.0 5.0 Wire TA 19 Hinge 600 Cable 5 3.0 4.0 5.0 X Shall withstand not Sample with ends Two 90 bends on a less than 15,000 volts sealed and foil bands 15" sample in the conductor to metal 2" apart exposed 16 same plane 2" apart X foil on an unbent hours at temperature around mandrel hav sample. Voltage rais- not less than 25C ing same diameter as ed at uniform rate of in closed chamber sample. No rupture from 500 to 1000 containing open ves- of covering and shall X volts per second. se! of water. Remov- not break down at ed and 200 volts D.C. less than 5000 volts immediately applied conductor to metal between bands. Leak- foil, filings or shot. X age resistance shall Voltage raised at uni- fc* not less than l form rate of from megohm per inch 500 to 1000 volts length per inch of per second. circumference. Test required only of sues 8 AWG and smaller. Type AVL AVA AVL TESTS TO BE MADE ON EACH FULL REEL LENGTH (1PCIA Standard S-28-357) (NEMA Standard WC-1-55) Page Description Conductors Single Multi-Conductor Lead Sheath Rated Voltage Full Reel Dielectric Test NEMA AVC 6-80A2 and A4 "Test Voltage (KV) 14 Lighting Wire X - X 600 1.5 10-U Control Cable - X -- 600 1.5 15 Power Cable X -- X 600 1.5 On Type AVL Single Conductor Cables voltage shill be applied for 5 tninures between conductor and lead sheath. On Type AVL Multi-Conductor Cables voltage shall be applied for J minutes between conductors and between the outet layer of conductors and lead sheath. On Type AVA Multi-Conductor Cables voltage shall be applied for 5 minutes between conductors. RBB 00506 3S TESTS ON SAMPLES OF FINISHED CABLE (IPCEA STANDARD S-28-357) Type AVA AVL AA AIA AF Pages 12 9 9 13 11 14 15 15 25 22 23 24 27 Description Lighting Wire 1/C Power Cable Motor Lead & Apparatus Cable Control Cable Lighting Wire 1/C Power Cable .. .e > Apparatus Cable Rheostat Wire Power & Rheostat Cable Apparatus Cable Fixture Wires (NEMA Standard WC-1-55) Rated Voltage 600 600 5000 Initial Dielectric Tests--(Kilovolts) * NEMA AVC 6-80A Standard l Minute Flame Dielectric Tests (kv) Test Period Minutes All Sizes 18-16 AWG l-W/o AWG 250 1000 MCM Resistance After After Above Test Flame Immersion 1000 NEMA NEMA NEMA MCM AVC 6-78B AVC 6-80B AVC 6-80C _ 3.0 3.0 _ _ X 0.9 i.: -- 3.0 3.0 4.0 5.0 X 0.9 1.2 --* -- 12.5 12.5 -- X 7.5 10.0 600 600 600 600 5000 300 600 600 600 300 5 -- 3.0 3.0 4.0 -- 5 3.0 -- -- -- -- X X 0.9 0.9 1.2 1.2 Not Requireo--See Test on Full Reel Lengths 1 1.0 -- -- __ 5 1.5 -- -- __ 5 1.5 -- __ __ __ 5 1.5 -- -- __ __ X X X X 1.0 0.9 0.9 0.9 1.2 1.2 1.2 Tests as required by Underwriters' Laboratories Standard for Flexible Cord and Fixture Wir On single conductor cables volute shell be applied between conductor end metal toil wrap. On multi-conductor cables voltage shall be applied between conductors and between the outer layer of conductors and metal foil. Voltage shall be applied between conductor and metal foil, iron filings or fine shot as required. Voltage shell be applied between conductot and water. | 36 RBB 00507 ALLOWABLE CURRENT-CARRYING CAPACITIES OF INSULATED COPPER CONDUCTORS IN AMPERES , (Botvd on Room Ttmptrature of 30C. 86F) NATIONAL ELECTRICAL CODE--TABLE 310-12 I NATIONAL ELECTRICAL CODE--TABLE 310-13 Net mere than three conductors In Rocowcy of Cable or Direct loriolI Single conductor in tree Air Size AWG MCM Rubber Type R Type RW Rubber TsBr Type RU RUH Type RUVP (14-2) (14-2) rhHiw RH^Iw See note 9 See note 9 Thermo R&P plastic Type T Thermo plastic Type TV Paper Tbcmoplastic Asbestos TTaTA Var-Cam Type V Asbestos Var-Cam Type AVB Ml Cable RHH* Asbestos Var-Cam Impreg nated Asbestos Tir {14-S> Asbraos Type A (Id-*) Type AA 14 12 10 8 6 4 3 2 1 0 00 000 0000 230 300 350 400 500 600 700 750 800 900 1.000 1.250 1.500 1.750 7.000 15 20 30 40 55 70 80 95 110 125 145 165 195 215 240 260 280 320 355 385 400 410 435 455 495 520 545 560 15 20 30 45 65 85 100 115 130 150 175 200 230 255 285 310 335 380 420 460 475 490 520 545 590 625 650 665 25 30 40 50 70 90 105 120 140 155 185 210 235 270 300 325 360 405 455 490 500 515 555 585 645 700 735 775 30 35 45 60 80 105 120 135 160 190 215 245 275 315 345 390 420 470 525 560 580 600 680 785 840 30 40 50 65 85 115 130 145 170 200 230 265 310 335 380 420 450 500 545 600 620 640 730 30 40 55 70 95 120 145 165 190 225 250 285 340 CORRECTION FACTOI FOR ROOM TEMPERATURES OVER 30C. 86F. Size AWG MCM Rubber Type R Type RW Rubber T#r Thermo plastic Asbestos Type RU RUH Type TA Impreg Type RUW <14-21 r|w 114-2) rh-Kvp $A Var-Cam Type V Asbestos Var-Cam nated Asbestos Asbestos Txr Type A (14-8) See note 9 Asbestos See note 9 iSRr Var-Cam ITl <14- Type AA Type Thermo Type AVB plastic Type T TypeTW Thermo plastic Type THW MI Cable RHH* SlowBurning T=rr 14 12 10 8 6 4 3 2 l 0 00 000 0000 250 300 350 400 500 600 700 750 800 900 1000 1250 1500 1750 2000 20 25 40 55 80 105 120 140 165 195 225 260 300 340 375 420 455 515 575 630 655 680 730 780 890 980 1070 117' 20 25 40 65 95 125 145 170 195 230 265 310 360 405 445 505 545 620 690 755 785 815 870 935 1065 1175 1280 1383 30 40 55 70 100 135 155 180 210 245 285 330 385 425 480 530 575 660 740 815 845 880 940 1000 1130 1260 1370 1470 40 50 65 85 120 160 180 210 245 285 330 385 445 495 555 610 665 765 855 940 960 1020 1165 1450 i 71 3 40 50 70 90 125 170 195 225 265 305 355 410 475 530 590 655 710 815 910 1005 1045 1085 1240 .. 45 55 75 100 135 180 210 240 280 325 370 430 510 .. , ., 30 40 55 70 100 130 150 175 205 235 275 320 370 410 460 510 555 630 710 780 810 845 905 965 .... 1215 -- 14(73 CORRECTION FACTOR FOR ROOM TEMPERATURES OVER J0C. 86F. CF 40 104 .82 .88 .90 .94 .95 45 113 .71 .82 .85 .90 .92 50 122 .58 -75 .80 .87 .89 53 131 .41 .67 .74 .83 .86 CF 40 104 45 113 50 122 55 131 .82 .71 .58 .41 i .88 | .82 .75 .67 .90 .85 .80 .74 .94 .95 .90 .92 .87 .89 .83 .86 60 140 70 158 75 167 80 176 .58 .67 .79 .83 .91 60 140 .35 .52 .71 .76 .87 70 151 .43 .66 .72 .86 75 161 .30 .61 .69 .84 80 176 .58 .67 .79 .83 .91 .35 .52 .71 .76 .87 .43 .66 .72 .86 .30 .61 .69 .84 90 194 100 212 120 248 140 284 .50 .61 .80 90 194 .51 .77 100 212 .69 120 24* .59 140 28-i .50 .61 .51 .80 .77 .69 39 The current-carrying capacities (or Type RHH conductors for sizes AWO 14, 12 and 10 shall be the same as designated for Type RH conductors in this Table. 0 NATIONAL ELECTRICAL CODE (NOTES TO TABLES 1. Ezplonetien el Tobies, for eipioaotie* of Type letters, end ter recognised tire el tondutfers for the toriovt cendwcter intuleiieni, tee Sectient 310-2 end 310-3. for intielle'iee reevirementi. tee Section 310-1 through 310-7. end rhe various Articles of this Cede, for flexible cords see Tables 400-9 end 400-11. 2. Application of Tables, for epee wiring on insulators and for conceded knob-end-lube work, the allowable current-carrying coeeciliei of Tablet 310-13 and 310-15 shell be used, for ell Other recognised wiring methods, the allow able current-carrying capacities el Tables 31012 end 3)0-14 shall be used, unless otherwise provided in this Cede. 3. Aluminum Conductors, for aluminum conductors, rhe allowable current carrying ceoocittet shell be in accordance with Tables 3)0-14 and 310-15. 4. bare Conductors. Where bore conductors d'e used with insulated conduc tors. their allowable currenl-cerrying capacity shell ba limited to that per mitted far the insulated conductors el the seme site. 5. Type Ml Cable. The temperature limitation on which the current.carrying capacities el Type Ml cable ere based, is determined by the insulating materials used in the end seel. Termination fittings Incorporating vmmpregnated organic insulating materials are limited to 8S*C. eeeratien. 6. Ultimate Insulation Temperature, in no cate shall conductors be associ ated together in such e woy with respect to the kind el circuit, the wiring method employed, or Ihe number el conductors, thgt the limiting temperature of the conductors will be exceeded. 7. Use of Conductors With Higher Operating Temperatures. Where the room temperature is within 10 degrees C .el ihe maximum ollewoble operating ternperalure of the Insulation, it is desirable to use on insulation with e higher maximum allowable operating temperature; although insulation can be used In e room temperature approaching its maximum allowable operating tempera ture limit if Ihe current is reduced in accordance witn rhe Correction Factors far diHereni roam temperatures. I. hSere Than Three Conductors in a gateway an Cable. Tables 310-12 and 310-14 give Ihe allowable current-carrying capacities let net mere then three conductors in a raceway or cable. Where the number el conductors in e 310-12 and 310-13) raceway or cable exceed* three. toe ollowobto <vrf#n*carrying cabde'y tech <ondv<ror MtoM bo reduced o thdvn in too following Table* Number of For Coni of Volvo* In , of 4 to d 80 7 to 24 ... 70 25 to 42 60 45 ond obdv* 50 Except5on--When conductor* of different mtem*. o provided to $eci>0 200-3. oro inttolled in o common rocewov too derating factor* shown above apply to the nvmbor of F#w#r ond lighting J Article* 210, 215, 220 and 230) con* dvetors only. 9. Where Typo IH-EW rubber tosuloted wiro it uiod in wo' loco'toM 'ho oliowdblo curroni'carrytop cQOecilie* then bo tod' of Column 2 * lob'ot 3)0*12 torevgh 310-15- Whoro utod m dry leco'ient the allowable current carrying copoc'rie* thdll bo thot of Column 3 to Tebloi 3)0*12 through 310*15. 10. OvorcwfTOAf Protection. Whoro too srendord relines ond *#ffing* of ovorcurroot device* do net correspond with the refines end letting* Oltowod for conductors, too not' hiehor tiondord rating end sotting moy be utod. 11. Neutral Conductor. A nou'rel conductor which corries only too enbel* onced currenr from otoor conductors, es <n toe cost of normolly balanced circuits of tore# or more conductors, shell not bo counted m determining current-carrying coeaci'ie* es provided for in Note 8. In o 3*wre circuit consisting of two photo wires end the nevtrgl of a 4*wiro, 3*photo system, o common conductor corries approximately the semo current os the other conductor* end is not therefor# considered es o neutral conductor. 12. Voltage Drop. The dltowoble current*earning cooocitiet in Tobies 310*12 through 310*15 or# based on temperature elone end do nor toko voltage drop imp considerotien. 13. Deterioration of Insulation. It should be noted thot even toe best gredes of rubber insulation win detorioroio in lime, to r*entuolly wilt need to be reploced. 37 RBB 00508 CONDUIT SIZE TABLES Percent Occupancy Allowed by NEC. (For Rewiring see page 39) f) i. 4 TABLE C 600 VOLT A.V.C. LIGHTING WIRE i Cable Number of Cables in Conduit Size Inches 1 2 3 4 $ 6 7i8 9 Minimum Size of Conduit 18 .220 16 .235 14 .245 12 .265 1/2 1/2 1/2 3/4 3/4 1 1/2 1/2 3/4 3/4 1 1 1/2 5/4 3/4 3/4 1 1 1/2 3/4 3/4 1 1 1 I l i l 1/4 11 ) 1 1 -4 | ] 1 '4 1 i 14 11 1 14 1 14 1 1 '4 10 .285 1/2 3/4 3/4 1 1 i 1 1/4 i i 1/4 1 1 1 '4 1 1 1 4 8 .310 6 .385 t/2 3/4 3/4 1 1/2 1 1 1 1/4 l 1/4 1 1/4 t 1 1/4 1 1/2 ' i 1/4 i 1/2 , 1 1 '2 12 1 i; 5 .405 4 .425 .450 .480 I .540 1/2 1 1 1/4 V 1/4 1 1/2 1 1/2 2 2 *2 y y1/2 t 1/4 1 1/4 1 1/4 1 1/2 > ' y1/2 1 1/4 l 1/4 l 1/2 l 1/2 2 2 .2 i ; 3/4 1 1/4 1 1/4 l 1/2 * y3/4 1 1/4 1 1/2 2 2 2 1/2 1/2 . , 2 12 1. 2 *> 3 y1/0 .575 3/4 1 1/2 1 1/2 2 2/0 .615 1 l 1/2 *> *> 2 1/2 2 1/2 2 1/2 > 1/2 ; |5 13 3 2VO .660 1 > y 2 1/2 2 1/2 3 > '3 3r 4/0 .710 1 2 2 1/2 .3 ! 5 l2 >i: TABLE E 600 VOLT A.V.C. POWER CABLE Cable Size Cable Inches 11 2i Number of Cables in Conduit 3I 4i 51 6j " 89 Minimum Size of Conduit IS .235 1/2 1/2 3/4 3/4 1 1 I 14 1 14 4 16 .250 1/2 3/4 3/4 54 1 1 ! 1 14 1 14 14 .265 1/2 3/4 3/4 1 1 V \ 1'4 1 1 -'4 1 14 12 .285 1/2 3/4 3/4 1 1 1 1/4 i 1/4 I 1/4 1 14 10 310 1/2 3/4 3/4 1 ! 1 -'4 : i.'4 i 1 '4 1 1/2 I 12 s ,t5() t/2 1 1 1 1 '4 1 1.4 1 !4 t 1. 2 1 1 '2 y<! .405 1/2 1 1 1/4 1 1/4 1 1,2 1 12 ** ** 2 2 y.430 1/2 1 1/4 1 1/4 1 1'1 l 1/2 2 y4 455 3/4 1 1/4 l 1/4 1 1.'2 l 1-2 - * 2i: > 480 3/4. 1 1/4 1 1/4 l 1/2 ** *> 2 1 '2 2 12 2 515 3/4 l 1/4 1 1/4 y y y 1 '2 2 1.2 2 12 1 25S5 3/4 1/2 1 1/2 y 2 1/2 2 1.2 J 3 21 0 .625 1 1 1/2 2 - 2 2 1/2 ; 3 2.-0 6"0 1 *2 y 1/2 2 '2 ; 3 3 l2 yy 2i 3 0 40 "20 -so 1 1 1/4 1/2 3 3 ; 3 1 '2 3l2 2 1/2 3 3 3 1 '2 3 1/2 4 2250 : S,5 1 1/4 2 1/2 1/2 3 3 1-2 5 K2 4 4 412 too oto 1 1/4 *> 1/2 2 1/2 3 '2 4 4 4 1/2 4 :; 350 .985 1 1/4 3 3 1/2 3 1/2 4 4 1/2 4 i : 5 1U0 ; 1.030 1 1/2 3 3 3 lO 4 4 4 l '2 3 5 450 sou 550 001) 650 700 "50 .S(ll) S50 `>1)0 >5,1 1000 1 2'0 1 too 1 "5(1 2000 . 1.0-5 1 115 1 165 1 205 1 240 i ;-5 1 510 1 545 1 3-s 1 104 1 454 l 465 1 6 10 I "64 1 SNtl 1 '>S4 1 1/2 y t 1/2 1 1/2 y22 2 2 2 2 1 '2 2 _3 5 3 3 1/2 3 \/2 3 1/2 3 1/2 3 1/2 4 4 4 -1 1'2 4 1/2 4 4 3 3 1/2 ) 1/2 3 1/2 3 1/2 3 t/2 3 1/2 4 4 4 4 4 1/2 5 5 6 3 i.': 1 '2 4 1 4 4 1 '2 4 1 -2 41 4 t '2 41 s 5 6 6 6 -- 4 4 4 1. 2 4 '2 4 '2 4 -2 5 5 5 5 6 6 6 _ -- 4 1 '2 4 '2 s 5 5 4 6 6 6 6 6 6 -- 4 1 -'2 4 5 < 6 6 6 6 (4 6 5 5 6 6 6 6 6 _ -- -- -- _ -- -- 6 6 (> 6 6 6 -- -- -- -- -- -- _ -- -- -- 38 RBB00509 CONDUIT SIZE TABLES TABLE EL Cable Size Oble Diam. Inches 18 16 14 12 10 8 6 5 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1250 1500 1750 2000 .270 .285 .300 .320 .340 .370 .420 .440 .470 .495 .560 .620 .660 .705 .760 .815 .945 1.000 1.050 1.095 1.140 1.180 1.265 1.300 1.340 1.375 1.405 1.440 1.470 1.500 1.530 1.560 1.770 1.890 2.005 2.110 LEAD SHEATHED A.V.C. POWER CARLE TABLE CL LEAD SHEATHED A.V.C. LIGHTING WIRE No. Cables in Conduit 234 Minimum Size of Conduit 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 1 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 l 1/2 1 1/2 2 2 2 2 2 *> 2 1/2 2 1/2 3 3 3/4 3/4 3/4 1 1 l 1 1/4 1 1/4 l 1/4 1 1/4 1 1/2 1 1/2 2 > 2 2 1/2 2 1/2 3 3 3 3 3 3 1/2 3 1/2 3 1/2 3 1/2 4 4 4 4 4 4 1/2 5 5 6 6 3/4 3/4 3/4 1 1 l 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 2 2 2 2 1/2 2 1/2 3 3 3 3 3 1/2 3 1/2 3 1/2 4 4 4 4 4 4 4 1/2 4 1/2 4 1/2 5 6 6 6 1 1 1 1 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 2 2 2 1/2 2 1/2 2 1/2 3 3 3 1/2 3 1/2 4 4 4 4 1/2 4 1/2 4 1/2 4 1/2 5 5 5 5 5 6 6 -- able Size 18 16 14 12 10 8 6 5 4 3 2 1 1/0 2/0 3/0 4/0 Cable Diam. Inches .245 .255 .270 .285 .310 .335 .400 .420 .440 .465 .495 .575 .610 .650 .695 .745 No. ables in Conduit 234 Minimum Size of Conduit 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 1 3/4 3/4 3/4 3/4 3/4 1 1 1 1/4 1 1/4 1 1/4 l 1/4 1 1/2 1 1/2 2 2 2 3/4 3/4 3/4 3/4 1 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 I 1/2 2 2 2 2 3/4 I 1 1 l 1 1/4 1 1/4 1 1/4 l 1/2 l 1/2 1 1/2 2 2 2 1/2 2 1/2 2 1/2 COMBINATIONS OF CONDUCTORS TABLE NO. 3 NEC P*r Cent Area of Conduit or Tubing Number of Conductors Over 44 Conductors (not lead covered).... 53 31 43 40 40 Lead-Covered conductors ............ 55 30 40 38 35 For rewiring existing raceways for increased load where it is im practicable to increase the size of the raceway due to structural conditions .................................... 60 40 50 50 50 MAXIMUM CABLE DIAMETERS FOR PERMISSIBLE CONDUIT FILL Size Inches 1/2 3/4 1 1/4 1 1/2 2 1/2 3 1/2 4 5 6 NOT LEAD COVERED No. Cables per Conduit 1 j y|3 .450 .598 1.000 i 1 | .243 -323 .412 .545 i '. .234 Ml -523 1.170 1.505 1.795 2.232 | .634 1 .814 ; .9-2 : i 1.206 | 61(7 .785 .935 1.161 2.585 2.930 3.281 i 1 398 . 1 345 ! 1.585 \ 1 524 j 1.776 : 1*06 3.675 1.9S* ! 1 910 4.415 j 2.390 j 2.296 4 .195 .260 .331 .437 .510 .654 .781 .969 1.123 1.273 1.425 1.596 1.920 LEAD COVERED No. Cables per Conduit l 23 4 .458 .609 .776 1.025 1.195 1.535 1.832 2.275 2.635 2.985 3-345 3.745 4.500 .239 .318 .405 .535 .624 .801 .956 1.187 1.375 1.559 1.745 1.955 2.350 .225 .300 .382 .505 .588 .755 .902 1.120 1.295 1.470 1.646 1.843 2.215 .190 .253 322 .426 .496 .637 .761 .945 1.094 1.240 1.389 1.555 1.870 REWIRING No. Cables per Conduit 1 23 4 .479 .636 .811 1.070 1.248 1.602 1.913 2.375 2.750 3.118' 3.490 3.910 4.700 .276 .367 .468 .618 .721 .925 1.105 1.371 1.588 1.800 2.015 2.257 2.715 .252 335 .427 .564 .658 .844 1.008 1.251 1.450 1.643 1.840 2.060 2.480 .218 .290 .370 .489 .570 .731 .873 1.084 1.255 1.423 1.593 1.784 2.145 RBB 00510 39 CURRENT RATING CORRECTION FACTORS FOR VARIOUS GROUPINGS OF CABLES OR CONDUITS {I. P. C. E. A. PUBLICATION No. P-29-2261 . .1 These tables list correction factors for the I specific groupings of conduits and cables and are applied to current ratings determined by the NEC Tables on page 37. Simply multiply the current rating by the correction factors for the specific groupings of conduits or cables. Number of Conduits Horizontally Vertically 2 3 4 5 6 For Cables in Conduit--Values of K 12 34 1.00 0.92 0.85 0.82 0.80 0.79 0.94 0 87 0.81 0.78 0 76 0 "5 0.91 0.84 0.78 0.74 0.72 O.'l 0.88 0.81 0.76 0.73 0.71 0.70 5 0.87 0.80 0.75 0.72 0.70 0.69 6 0.86 0.79 0.74 0.72 0.70 0.68 Number of Cables Horizontally Vertically 1 2 3 4 5 6 For Cables in Air--Values of K 1 234 1.00 0.89 0.80 0.77 0.75 0.74 0.93 0.S3 0.~6 0.72 0.70 0.69 0.87 0.79 0.72 0.68 0.66 0.64 0.84 0.76 0.70 0.67 0.65 0.63 5 0.83 0.75 0.69 0.66 0.6-1 0.62 6 0.82 0.74 0.68 0.65 0.63 0.61 Note--Th* correction (actors apply only when the spicing bcmcen cible or conduit turfices is not greater thin cable oi conduit diameter, or less than one-quarter of cable or conduit diameter. Minimum Bending Radii for Rockbestos Wires and Cables This catalog shows many "standard" and "special" Rockbestos wires and cables and be cause both construction and diameter determine the Bending Radius, information on any specific wire or cable will be furnished on request. 40 RBB 00511 TERMINAL and JOINT INSULATION FOR A.V.C. CABLE In general, no special precautions are necessary in the insulating and waterproofing of terminals or joints in A.V.C. cable runs. This is because of the additional ther mal capacity of thermal ends and joints, plus the fact that in general such terminal ends or joints are in cooler ambient locations than the main run of the cable. In this type of location it is common practice to use rubber tape and friction tape as a means of insulation. For large sizes of A.V.C. cable where a splice is neces sary, it is advisable to build up the joint with layers of varnished cambric tapes prior to the application of the rubber and friction tapes. In wet locations where lead covered A.V.C. cable is used, the same practice is used except that the friction tape is treated with a glyptal varnish or Irvington oil stop. The illustration below shows a recommendation for such a cable splice. In all high voltage, i.e. over 600 volts, all terminal ends and joints should be insulated with varnished cambric tape before applying the rubber or friction tapes. The friction tape should be treated with either glyptal varnish or Irvington oil stop. Where it is necessary either to terminate or make a jomt in a high ambient temperature zone, we recommend that the joint or terminal end be insulated with layers of var nished cambric tapes wrapped with asbestos listing. List ing can be coated with wax or covered overall with friction tape. SUGGESTED METHOD OF SPLICING AVA OR AVL CABLE 1. Prepare cable ends and joint with standard soldered or mechanical connector. 2. Paint connection and adjacent insulation with compound such as glyptal varnish or Irvington Oil Stop. 3. Apply layers of varnished cambric tape with glyptal varnish or Irvington Oil Stop between layers to fill up space even with braid or lead sheath. 4. Apply two layers of rubber tape, and then two more layers of friction tape with glyptal varnish or Irvington Oil Stop between all layers and over surface. Extend rubber and friction tape over at least two inches of the cable sheath or braid which previously had been painted. 3. In case of lead sheathed cable where joint will be in wet location, a lead sheath and wiped joint may be used. % RBB 00512 BARE COPPER WIRE DATA ALL DATA TO ASTM B-258 RESISTANCE (BUREAU OF STANDARDS) f\ Size AWG Dim. laches Circular Mils LBS/1000' FT/LB OHMS/1000' 1 20C (68F) : Sire AWG 4/0 .460 211.600 640.5 3/0 .410 167.800 507.9 2/0 -365 133.100 402.8 I/O .325 105.600 319.5 1.561 1.968 2.482 3.130 .04901 .06180 .07793 .09827 : VO 3- 0 1 '0 1 .289 83.690 253.3 2 .258 66.360 200.9 3 .229 52.620 . 159.3 4 .204 41.740 126.4 3.947 4.977 6.276 7.914 .1239 .1563 .1970 .2485 1 3 4 5 .182 33.090 100.2 6 .162 26.240 79.46 7 .144 20.820 63.02 8 .128 14.510 49.98 9.980 12.58 15.87 20.01 3133 3951 .4982 .6282 6 8 9 .114 13.090 39.63 10 .102 10.380 31.43 11 .091 8.230 24.92 12 .081 6.530 19.7- 25.23 31.82 40.12 50.59 792! 9989 1.260 1.588 9 12 13 .072 5.180 15.68 14 .064 4.110 12.43 63.80 80.44 2.003 2.525 15 .057 3.260 9.858 101.4 3184 15 16 .051 2.580 7.818 127.9 4.016 16 17 .045 2.050 6.200 161.3 5 064 * 18 19 .040 .036 1.620 1.290 4.917 3.899 203.4 256.5 6.385 8.051 18 20 .032 1.020 3.092 323.4 10.15 20 21 22 .028 812 2.452 407.8 12.80 : .025 640 1.945 514.2 16.14 ; 23 .0226 511 1.542 648.4 20 36 : .020 404 1.223 817.7 25 67 24 25 28 29 30 31 , 32 .0179 .0159 .0142 .0126 .0113 .010 .0089 .0080 320 253 202 159 128 too >9.2 64.0 , .9699 -7692 .6100 .4837 .3836 .3042 .2413 .1913 1031. 1300. 1639. 2067 2607. 3287. 4145. 5227. 32.37 40.81 51.47 64 90 81 83 103.2 130.1 164.1 ` ' 26 2S 29 30 31 52 33 34 36 i 37 ! 38 ! 39 ; .OO't .0063 .0056 00i0 .004 ' .0040 .0035 .0051 j 1 j 504 39.7 31 4 25 0 20 2 16.0 12.2 9.61 ' ' ' .1517 .1203 .09542 .07568 .06001 04759 .03774 .02993 6591. 8310. 10480. 13210 16660 21010. 26500. 33410. 206.9 260 9 329.0 414.8 525-1 659.6 S31.8 1049. i ' 34 35 56 37 38 39 40 42 RBB 00513 RETURNABLE REEL DATA a REEL DIMENSIONS -- INCHES Flange (A) .......................................................................................... Traverse (T) ........................................................................................ Drum (8) ............................................................................................ Max. Width (W) ............................................................................... Vol. Cu. Ft............................................................................................. Approx. ,l 1-- All Wood ............................................................ Weight UM- Wood-Steel Drum ............................................. 42 12 24 18% 19.1 130 185 48 15 24 21% 29.0 184 48 24 24 30% 40.6 250 275 60 32 32 40% 84.4 500 500 66 32 32 40% 102 550 : ; i ] : ' 66 36 40 45 114 650 650 72 j 36 ; 40 . 45 135 790 790 -2 36 4S 45 135 820 820 Cable Diam., laches .500 .520 .540 .360 380 .400 .420 .440 .460 .480 .500 .550 .600 .650 .700 .750 .800 .850 0 .900 -950 1.00 1.05 1.10 1.15 1.20 1.25 1-30 MAXIMUM CAPACITY FOR SOLID COVDt.'CTOR OR LEADED CABLE 1.35 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 NOTES: 1. Clearance (X) meets IPCEA Standards on -300" diameter and over. 2. Use max. dia. of cable to determine reel size. 3- All capacities shown in this table meet a recommended drum diameter (B) equal to 14 times the cable diameter. For all leaded and solid conductor AVA cables, the recommended drum diameters (B) are 18 times the cable diameter--see above solid line. 4. All reels with leaded cables (30" flange and larger) to be wood lagged. Lagging adds the following to reel weight: Size Reel Wgt. of Laggiag Lbs. Size Reel Wgt. of Laggiog Lbs. 8080 7190 6300 5670 4990 4530 4100 3710 3460 3170 2890 2410 1980 1680 1450 1300 1120 976 891 777 716 629 582 543 Recommended Maximum Capacity--Feet Pei Reel 10714 9938 8883 8129 7447 6682 6133 5670 4691 3910 3360 2840 2490 2170 1910 1760 1560 1380 1280 1140 1060 9070 7500 6260 5380 4540 3980 3470 3060 2810 2490 2210 2050 1820 1700 9630 8490 7250 6440 5730 5090 4730 4224 3770 3540 9810 8300 7460 6700 6000 5360 5190 4630 X -- Clearance between top layer of cable and flange edge. 9590 7800 6940 6130 5680 5100 4560 4230 8370 7540 6790 6310 5710 8980 7950 7220 6420 5740 5270 4730 4380 477 946 1510 445 888 1420 418 841 1350 394 747 1190 345 706 1130 326 672 1070 308 594 949 292 565 905 278 541 864 262 516 825 231 456 728 Cable Diam.. laches 1.80 ................. 1.85 ................. 1.90 ................. 2.00 2.10 .................... 2.20 .......... 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3180 2990 2690 2540 2400 2160 2050 1950 1760 1670 1600 1530 1370 1320 1270 1090 1010 938 4110 3990 3530 3440 3020 2950 2570 2510 2460 2120 2080 2040 1740 1710 1680 1390 1350 1100 3810 3550 3200 3020 2840 2570 2420 2300 2190 1970 1880 1800 1710 1550 1480 1360 1260 1090 1010 941 880 762 714 671 5170 4850 4400 4150 3770 3580 3400 3070 2930 2650 2540 2430 2360 2110 2030 1870 1630 1520 1420 1230 1160 1090 1030 894 3950 3670 3440 3120 2920 2750 2490 2360 2230 2120 1920 1830 1740 1660 1590 1380 1260 1170 1080 941 874 818 764 718 625 588 42x12 48x15 48x24 80 90 101 60x32 66x32 66x36 72x36 210 240 270 300 RBB 00514