c_ L w'*T S / C BUSINESS confidential INTERNAL CORRESPONDENCE uc ut- a CHEMICALS AND PLASTICS to (name) COMPANY LOCATION See Attached Distribution DATV P* . BOX Bit TBXAB CITY, TKXAI ft MO January 21, 1975 COPY TO Gentlemen: SUBJECT Vinyl Chloride Respiratory Equipment Based on the proposed permanent standard (which is under study by the courts) our fresh air respiratory equipment needs upgrading as follows: ,1. Emergency self-contained breathing apparatus, demand type (rated up to 100 ppm VCM) should be upgraded to pressure demand type (rated for unknown concentrations and above 3600 ppm). Estimated cost is $60 per unit. 2. Air line respirator Type C, demand, one-half face piece (rated up to 10 ppm VCM) should be upgraded to either: (a) Combination Type C, pressure demand, auxiliary egress cylinder, full face olece (rated up to 3600 ppm VCM). Estimated cost per unit is $315. -0R- (b) Type C, continuous flow, onerhalf face piece (rated up to 1000 ppm). Piped in air supply is required for continuous flow. 3. Additionally, four-hour canister gas masks which provide mobility are needed for concentrations up to 25 ppm VCM. The M-S-A* GMA Canister, part number 461U80, has NI0SH approval TC-l^-G-M. Bulk cost is $11.50 each. Complete mask part number is A61A83. The proposed schedule Is consistent with regulations for other carcinogens. Rationale precludes contamination caused by poor fit couoled with negative pressure. Therefore, all respiratory equipment rated for above 100 ppm VCM is either continuous flow or pressure demand type. Presently, no ucc 048051 4 Vinyl Chloride R spiratory Equip. -2- January 21, 1975 approval has granted the use of a half-face piece with pressure demand. We recommend the Immediate Implementation of the three types of respiratory protection listed above In the Vlnyllte Area. Secondly, a long range plan should be formulated to upgrade the emergency SCBA demand type to pressure demand on a plant-wide basis. Please contact us If there are additional questions. Very truly yours. ec Attachment D. E. Deese Industrial Hygiene Director IJCC 048052 VCM RESPIRATORS PPM VCM TYPE MODE AUX. PACE PIECE Unknown, 3600 * ' $>CBA i i Press. Dem. Pull $60 > 3600 p -- ^Comb. Type C Press. Dem. Aux. Pull or 1/2* $315 i: j J-----* 1000 Comb. Type C Cont. Plow Aux. Pull or 1/2 Type C Cont. Plow Pull, 1/2, Helmet, Hood 1 J* :nimum desirabl ; AIR LINE PR DTECT] ON LEVEL) )100 1 1 ^ Comb. Tyne C ' '"`SCBA** Dem. Dem. Aux. Pull Full 1 11 1-^5 1 1--!. Type C Respirator *<~Hr. Can. Gas Mask*** *i~Hr. Can. Dem. Powered Front or Back Pull Pull, 1/2, Helmet, Hood Comb. Type C Dem. Aux. 1/2 Type C** Dem. 1/2 Respirator 1-Hr. Cart. *l/2-No Approval. Used At Texas City. M-S-A GMA Canister - NIOSH TC-1*UG-8*I, Pt No. K6l*80 ($11**19). Complete Mask Pt No. *6l*83 Desired At Texas City UcC _ 0480^3 DISTRIBUTION To: Mr. M. E. Eisenhour Mr. D. L. Engle Mr. R. L. Frantz Dr. D. H. Glenn Mr. R. E. Graebert Mr. J. L. Hockersmith Mr. J. B. Leverton Mr. R. R. Mayfield Mr. H. A. Mazzolini/ Mr. E. N. Lund Mr. R. E. Peele Mr. F. R. Pierce Mr. R. E. Ross Mr. A. R. Ryrholm/ Mr. B. L. Murray Mr. R. W. Sesler Mr. C. 0. Steinmetz Mr. G. F. Tacquard Mr. J. W. Thompson IMr. W. R. van der Hoeven Mr. R. N. Wheeler Industrial Hygiene Staff V V ' ". *r- -- UCC 048054