Document 6w5BempgdmEwzVM8qkaZdxBaR

**.. ( 'OOD AND DRUG ADMINISTRATION ' COMPLIANCE PROGRAM GUIDANCE MANUAL PROGRAM 7306.02 CHAPTER 6 - DAIRY INDUSTRY Program Activity: Surveillance, Compliance Problem Code: FH-18 Data Control Code: 6F-320-024 Commodity Code: 17 Project Code: 05 SUBJECT: SURVEY: POLYCHLORINATED BIPHENYLS IN MILK PURPOSE To provide guidance to the districts In conducting a turvey of fluid milk for the polychlorinated biphenyls. BACKGROUND . In 1970 PCB's were detected In milk samples from West Virginia. Follow up Investigation ( revealed the apparent misuse of an electrical transformer fluid containing PCB as a vehicle '. for defoliant spraying operations adjacent to dairy pasturoge as being responsible for the milk contamination. PCB's have also been found to be a component of sealants used to treat silos on dolry farms. Milk contamination has resulted from this source of PCB's. Subsequent Information derived from the total diet studies program, the general pesticide program, and other food surveys has shown the presence of PCB's In fish, milk, eggs, In grayboard used In cereal packaging materials and In the cereal product Itself. Surveys to date reveal that additional data Is necessary to determine the extent of PCB occurrence In milk. Information Is desired to determine the condition of milk used for bottling purposes and milk used for manufacturing purposes with respect to PCB contamination. For the purpose of this turvey "bottling milk" It milk which Is destined for pasteurisation and subsequent bottling for direct consumer use. "Manufacturing milk" It milk intended for use at a raw material In the production of a consumer dairy product (e.g., NFDM, condensed milk, cheese, butter, and Ice cream). OBJECTIVE MONS 094074 .To survey the milk supply on a state by stale basis to determine the extent of PCB contamination of milk for bottling and manufacturing use. TRANSMITSAL NO. 72-8 (2/3/72) originator: Bureau of Foods, Division of Compliance Programs, ' Program Development Branch, BF--323 PACE I PROCRAM 7306.02 ) APPROACH 1, Inspectlonol Districts or* responsible for follow-up Investigations Including Inspections If'necessary to determine the source of any PCB contamination detected. The Districts should work with the Regional Milk and Food Consultants and state and local officials to determine sampling sources and to facilitate follow-up activities. There will be no CP-IP Issuance by EDRO for this program. 2. Sample Collection The'attached distrlct/state sampling schedule has been developed from available Information regarding the milk production of each state for both bottling and manufacturing use. Districts should make every effort to collect the samples as specified and to distinguish between milk for bottling and milk for manufacturing use. It Is recognized that In some Instances the latter will not be possible. Sampling sources should be selected on a random basis to reflect milk production end usage within each state. Samples may be collected from both Interstate and 1 Intrastate sources. - Bottling Milk Manufacturing : District State Samples 4b Milk Samples 12 Total Samples ....... 52 ATL-DO Georgia 5 5 Florida 7 -7 Alabama 314 Mississippi 41 5 Tennessee 6 39 i North Carolina 6 1 7 South Corollna 3 2 5 Kentucky 6 4 10 : 8LT-DO Maryland Virginia West Virginia 13 6 6 1 3 16 17 17 12 TRANSMITTAL NO. 72-8 (2/3/72) PAGE 2 HONS 094075 :' District BOS-DO ' * * State .Maine ' New Hampshire Vermont Rhode Island Connecticut Massachusetts BUF-DO New York .CIN-DO Ohio CHI-DO Illinois DAL-DO New Mexico Oklahoma Texas DEN-DO North Dakota South Dakota Montana Wyoming Colorado Utah DET-DO Michigan Indiana KAN-DO TKANSMITTAL NO. Iowa Nebraska Kansas Missouri 72-8 (2/3/72) PS OGRAM 7306.02 Bottling Milk Samples 19 2 1 9 1 3 3 46 46 17 17 9 9 19 1 5 13 9 1 1 1 1 3 2- 27 18 9 22 6 3 5 8' Manufacturing Milk Samples Total Samols C . _ _ - 19 2 > 1 9 I 3 3 0 46 - 46 2 19 2 19 4 13 4 13 1 20 1 16 0 13 II 2 5 1 1 1. 1 20 3 6 2 2 4 3 5 32 3 21 2 II 23 45 13 19 36 27 5 13 p*oe 3 MOMS 094076 PROGRAM 7306.02 'T&yOUtrlct C >: >. UOSrOO MIN-00 NOL-DO , NYK-DO PHI-DO SAN-DO SEA-DO y/.'./fiio:. , ' ." Slot* California ' Arizona Minnesota Wisconsin . Louttana Arkansas New York New Jersey Puerto Rico Virgin Island Pennsylvania Delaware California Nevada Hawaii Washington Idaho Oregon Alaska Totals Bottling Milk , Samples Manufacturing Milk Samples Total Samples . 20 18 2 2 .22 ' 2..................... 20 02 51 71 122 10 32 42 41 39 80 71 521 8 5 3 52 .- . - 7 0 3- 3 1 1 (If available) 2 1 1 (if available) 2 30 1 31 29 1 30 11 20 2 22 18 2 20 1- 1 11 15 . 9 2 3 1 6 - 5 1 21 9. 7 4 1 369 146 515 < ~ V ... ' TAANtMITTAL NO. 72-8 (2/3/72) n6 4 HUNS 094077 I PROGRAM 7306.02 '" V*................. . ` ' ' Samples should consist ofjfquarts of fluid milk collected from route collection trucki (bulk form milk pick-up) on completion of pickup or from collection station points prior to further dilution of the milk at the processing plant. If milk Is received In cons at the processor, somples should be collected from the holding tanks prior to process. Plastic containers or containers in which the contents come Into contact with rubber or - cardboard closures or Inserts should not be used In the collection of samples for PCB analysis. One quart Mason jars, which have been washed to rinse out cardboard particles or other foreign matter which may interfere with PC8 analysis, may be used. Tin foil should be Inserted beneoth the |ar lid and screw top to prevent milk contact with the rubber gasket. - Aseptic technique (sterile ladles) should be used In collecting samples for this survey to avoid adding to the bacterial lood of the bulk milk from which the sample Is collected. Samples may be official or Investigational. Collection reports should be flagged "PCB ' Milk Survey" and should Include the following Information. I. Slate where collected. , 2. Point of collection (e.g., route truck, holding tank, etc.). 3. Volume of milk sampled. 4. Number of producers represented. ' 5. Type of milk (e.g., bottling, manufacturing). . 6. Milk route number or patron(s) can number. 7. Route truck number or license number. See Inspector Operations Manual, Chapter 4, Sections 443.2, 452.2, 454, and 454.3 for guidance In sample handling, shipment, and notification of receiving laboratory. 3. Sample Analysis Analyze samples for PCB, orga'nochlorlne and orgbnophosphorus pesticide residues using appropriate PAMVol. I methodology for extraction, cleanup, and GLC determination: extraction 2ll.l3h(l) (4/1/71 revision) cleanup, 211.14a,d (4/1/71 revision); EC-KCLTD GLC, 321. Infect approximately 3 mg milk fat equivalent for GLC. Analyze 20% of the District sample quota (with a minimum of four samples) for the chlorophenoxy acid residues. - Determine residues of pesticides in the usual manner. Evaluate EC-GLC chromatogram of 6% Florist) eluate for presence of PCB and pesticides. If presence of PCB Is indicated, complete analysis using the necessary treatment of extract prior to GLC determination. TRANSMITS AS HO. 72-8 (2/3/72) PACK 5 ttOAii 09 <,0 78 PROGRAM 7306.02 In most Instances whan both PCS and DDT and analog ore present, the PCS and organo- chlorine pesticides require separation by chromatography on Silicic acid (Armour and *: Burke, JAOAC 53 , 761 (I970)| prior to determination. In some Instances dehydrochlo rination of DDJ and TDE to their respective olefins (Sawyer and Krause, LIB 1249 (Jan. 8, 1971)), or a combination of dehydrothlorlnation followed by oxidation of olefins to the respective dichlorobenzophertone (Mu I hern, et al, JAOAC 54, 548 (1971)1 will permit quantitation of PCB without.column chromatographic separation. Appropriate treatment will depend on the PCB (Aroclor(s)l indicated present, the particular pestlcide(s), and the relative amounts of PCB and pesticides. Aroclors 1221, 1232, and 1242 divide between the petroleum ether and polar solvent eluates from the silicic acid column, but residues of these Aroclors can possibly be quantitated In the presence of DDT and analogs, and would not necessarily require column chroma tographic separation from these pesticides. Previous experience Indicates that PCB residues in cows' milk will be more similar in GLC pattern to Aroclors 1254 or 1260. Quantitate PCB residues by electron capture GLC or by use of halogen specific mlcrocoulometric or electrolytic conductivity GLC detectors. Compare the total area response from the PCB residue to the totol area response from a known weight of the Aroclor with most slmllor GLC pattern. However, If the GLC curve shows that the PCB residue clearly consists of components of more than one Aroclor, if possible quantitate the residues separately using the appropriate Aroclor reference for the respective portion of the GLC curve. When PCB residue Is 5 ppm or above in the fat, confirm residue identity by GLC with halogen specific mlcroeoulometric or electrolytic conductivity detectors anc|/or demonstration of the residue's stability to boiling alkali. Additional confirmatory analyses are left to discretion of the Laboratory Director. Limit of detection for PCB residue In milk fat is approximately 1.5 ppm (as Aroclor 1254), when using a 3 mg sample Injection and EC-GLC operated at the above conditions. Report PCB residue in terms of Aroclor(s) used In quantitation (e.g., 2 ppm Aroclor - . 1242 and 3 ppm Aroclor 1260). '" PCB residue levels In milk fat should be rounded off to the nearest 0.1 ppm. vnANSMiTTAL NO. 72-8 (2/3/72) PACiC 6 HONS 094079