Document 6w2p21VMNw73g2pzXq0BRvwvg
Temperature Control
GENERALieirCONTROLS
ISOS (ROADWAY CLEVELAND. OHIO
1368 HARRISON ST. SAN FRANCISCO. CALIF.
DEPENDABLE CONTROL OF TEMPERATURE-PRESSURE-FLOW
There is a GENERAL magnetic valve specifically designed to control each fluid and gas. For example, the GENERAL
K-10 lever action gives it the power to operate dependably on oils as heavy as
No. 6. The K-15 handles refrigerants without corrosion; the B-6 is particularly
adapted to zone control; the K-3B is characteristically suited to gas; the K-12
to ammonia, etc. Please write for com plete catalog.
MAGNETIC GAS VALVE
TYPE K-3B
Primary Applications--Controlling
gas to hot-air furnaces and industrial
boilers; safety shut-off.
The GENERAL K-3B is a two-wire,
straight-magnetic, current-failure valve of
packless construction. Closing with the
flow, the pressure is on top of the seat,
insuring a tight shut
off,indefinitely. Solen
oid is absolutely hum
less--a feature origi
nated by GENERAL
CONTROLS. Manual
by-pass allows for
opening in case of
prolonged current fail
ure. Terminal boxes
may be turned in any
direction to facilitate
KSB
wiring.
The B-55 is a diaphragm valve with an adjustable opening time of from 5 to 60 sec., using the GENERAL current-failure solenoid as the pilot valve.
THERMOSTAT-THE METROTHERM
Adjustable heat acceleration is fea tured in this beau tiful new METROTHERM. Low thermal inertia guarantees instant response to small temperature change ana eliminates under- and over shooting of set tem perature. Luxuri ously finished in sprayed silver and chrome.
REFRIGERANT CONTROL TYPE K-15
Primary Applications--Controlling the flow of methyl, SO Freon or Brine, water, air, gases.
The GENERAL K-15 is a full-ported, current-fail ure, pilot-operated solenoid valve of packless construc tion. Closes with the pres
ELECTRIC SLOW OPENING GAS
VALVE--TYPE B-55
Primary Application--Simultaneous control of gas flow and damper opening.
sure on top of the seat, giving an absolutely tight
shut-off. All materials are
adapted to refrigerants and are non-corrosive.
K-I6
SEMI-BALANCED--TYPE B-6
Primary Applica tions--For water, air, gas, oil; zone control.
The GENERAL B-6 is a semi-balanced, current-failure solenoid valve valuable in the automatic regulation of large flows. Speci fically designed for zone control in hot water heating systems. Humless and quiet in operation.
1112
Temperature Control
The Mercoid Corporation
SOLE MANUFACTURERS OF THE MERCOID SWITCH
Chicago. III. 4201 Belmont Ave.
New York. N. Y. 90 West Street
Boston. Mass. ' 25 Ivy Street
Philadelphia, Pa. 3137 N. Broad Street
COMPLETE LINE OF AUTOMATIC CONTROLS AND MAGNETIC VALVES FOR HEATING AND AIR CONDITIONING
The selection of the right kind of controls is of supreme importance for any type of automatic equipment. All Mercoid Controls are equipped with sealed mercury contact switches. These switches
cannot be affected by dust, dirt or corrosion. Mercoid Controls are dependable under all operating conditions. They require little labor for installation or time for making
* < r~> ,-i -- xt- irvUC
SENSATHERM
Extremely sensitive ther mostat which requires no artificial stimulation to main tain an even room tempera ture. Operates on tempera ture variation of J4 above or below point set (total dif ferential 1 F). Small in size, neat in appearance and un failing in performance.
COMBINED PRESSURE AND LOW
WATER CONTROL .
These instruments guard against the hazard of building up excess pressure or firing into dry boilers. Have visible calibrated dials which show the pressures at which in struments are set to operate.. Easy to install and adjust. Every automatically fired steam boiler needs this protection.
TRANSFORMER-RELAY
A low voltage transformerrelay but also operates as a mercury contact repulsion re lay. Does not hum or chatter. No residual magnetism. De signed to meet severe service conditions encountered with automatic operating equip
ment. Write for Bulletin 110G.
SAFETY CONTROLS
"K" line controls have a number of desirable features which make them pre1 eminent in the field. KMI illustrated herewith, is for burners employing intermit tent ignition. Other types available. These controls offer positive protection against flame or ignition failure.
PRESSURE CONTROL
These instruments are not only reliable over a long period of years, but they are also easy to install and adjust for all operating conditions. Available for steam, hot water and warm air furnaces. These instruments represent a great saving in time as it- is not necessary to do any figuring.
STOKATHERM"
This stoker control oper ates stoker for only the very shortest periods necessary , to maintain a fire while ther mostat is off. Prevents over heating and saves fuel. Auto matically stops stoker in case fire goes out. A Mercoid Stok-A-Timer is also available where a reliable stoker timer is required.
1113