Document 6w2JEQnjpYzZq6GEj0YwzamXE

Friday March 23, 1094 \ Part 111 Environmental Protection Agency 40 CFR Part 791 Polychlorinated Blphtnyla (PCBs); Manufacture, Proceeelng, Oletrlbutlon tn Commerce and Use Prohlbltlone; Uae In Electrical Transformers; Advanced Notice of Proposed Rulemaking MOMS 214108 11070 Federal Register / Vol. 48, No. sa / Friday, March 23, 1864 / Proposed Rule* ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part Ml I OPTO 12039; TSH-FRL W28-7I Polychlorinated Biphenyls (PCBe); Manufacture, Processing, Dlatrlbutlon In Commerce and Uee Prohibition a; Use In Electrical Treneformere / AOIHCV: Environmental Protection Agency {EPA) action* Advance notice of propoied rulemaking summary: EPA ieeued a final rule which wai pubilehed In the Federal Register of August 25, 1982 (47 FR 37342) that, among other provisions, authorised the Indefinite use of certain electrical transformers containing polychlorinated biphenyls (PCBe) (PCB Electrical Use Rule) Although EPA had knowledge prior to August 25,1982 of a major firerelaied Incident In Binghamton. New York Involving a PCB-Transformer, EPA believed that fires involving this , equipment were rare. Isolated incidents. Thus, EPA did not consider the risks * posed from fires when EPA made lie determination that the continued use of electrical transformers containing PCBe did not pose unreasonable risks to public health or the environment. Recant information from a May 1983 fire-related incident in San Francisco, California Involving a PCB-Tranaformer and September 1983 firs related event In Chicago, Illinois Involvings PQ5T raneformer hei brought into question EPA s earlier assumption that firs* related events Involving PCBTransformers are rare and isolated occurrences. The purposes of Issuing tbit Advance Notice of Proposed Rulemaking (ANPR) ere to eollclt dale specific to the rleke posed by first In vol vlng electrical transformers that contain PCB* and to solicit dels on mechanisms for mitigating or eliminating thssa risks. Depending upon the results ofEPA's analysis of these data. EPA may propose further control measures on the use of this equipment by October 1984. datei: Comments on tha Issues raised in ihie Notice mull be submitted by Mey 22.1984. ADDAFisea: Comments should be submitted In triplicate lo- TSCA Public Information Office (TS-793). Office of Toxic Subtleness, Environments! Protection Agency, Rm E-108, 401 M St., SW,, Washington, DC, 20480. Commend should Include tha docket number OPTS-62035 Comments received In connection with this Notice will be evelleble for reviewing end oopying from 8.-00 e m to 4:00 p m. Mondiy through Fridey. excluding holidays, In Rm. E-107. Environmental Protection Agency, 401 M Streak SW., Washington, D C. rod furthir information contact. lack P McCarthy. Director. TSCA Assistance Office (TS-799), Oflics of Toxic Substances. Environmental Protection Agency. Rm. E-543,401M St.. SW.. Washington, D C. 20480. Toll free: ' (800-424-9085), In Weihlnglon. D.C.: (554-1404), Outside the USA; (Operetor202-554-1404). UFMfH|NTARV INFORMATION! I. Background^ ' ^RFCftor^fe) of the Toxic Substance* Control Ad (TSCA) generalfy prohibit tha uaa of PCB* afttr January 1,1979 Tha ataluta doe*, howavar. aal forth two exctptlone under which EPA may. by ruit, allow particular uaa of PCB* lo continue. Under section 8(e)(2) of TSCA. EPA mey allow PCBe to be used In * "totally enclosed manner." A "totally enclosed manner" is defined by TSCA lo be "any manner which will ensure that any exposure of human beings or the environment to a polychlorinated biphenyl will be Insignificant, a* determined by tha Administrator by rule." TSCA also allow* EPA to authorize the usi of PCB* In a manner other than a totally enoloead manner if the Agency finds that tha uaa "will not resent an unrttsonabls risk of Injury to sslth or the environment." EPA promulgated a rule, which we* published in the Federal Register of Mey 31,1979 (44 FR 31514) to implement sections8(e) (2) and (3) of TSCA. TUe nil# is Hated In the Cods of Federal Regulation* under 40 CFR Pert 781. Tha rule, among other provltton*. designated all Intact nonleaking capacitor*, electromagnet*. *nd transformer*, other th*n railroad transformer*. * "totally anctoaad," thu* permitting thsfrues without specific authorization* or condition* Th* Environment *1 Def*n* Fund (EDF) petitioned the U.S. Court of Appeal* for the District of Columbia Circuit to review number of provision* of Ih* rule, including ths portion of the rule that designated ell intact and nonletking capacitors, electromagnet*. nd transformer* "totally enclosed." (;> vironmenla! Defense Fund, Inc v, Environmental Protection Agency. 838 F 2d 1287). On October 30.1980, the courL among other things, decided the! there wae insufficient evidence in the record to support the Agency'* classification of transformer*, capacitor*, and electromagnet* a* totally enclosed. Th* court invalidated (hi* portion of (he rule, i well ** * number of other provision*, nd remanded the rule lo EPA for further ecilon A* * consequence of the October 1980 decision, EPA undertook * number of rulemaking action* Tha action relevant la the rule which la the aubfect of today's ANPR was published In the Federal Register of August 25,1982 (47 TO 57342) (hereafter, PCB Electrical Use Rule). This nil* amended the May 31. 1879 rule, Th* August 1982 amendment, among other provisions, authorized (he continued us* of PCB-Trensformers [electrical traniformera containing greater than too parts per million (ppm PCBa) In fadliltaa involved tn the handling of food or feed Item* until October 1.1985. and. allowed tha uaa of all other categories of non.railroad alaclrlca! transformer* containing or contaminated with PCBa for th* remainder of their useful lives. In It* August 25,1982 dectalon. EPA made e determination that authorizing the us* of ibeas transformer* for tha remainder of their assful livaa did not preeenl an amreeaonebla riak to public health or lha environment for tha following raaaonr 1. EPA determined that If It did not authorize the uaa of PCBa tn transformer*, tha coat* to the public and United Sietee Industry would be billions of dollar*, primarily aa a result of tha disruption of electrical sarvlca EPA determined thal lha resulting reduction In riak would not outweigh tneee substantial coat*. 2 EPA detarmlnad thal ihe Inspection nd maintenance program* required under lha rule reasonably reduced the exposure risk* associated with tha uaa of PCBa tn PCB Transformers, end the servicing condition* prevented further PCB contamination of transformer*. 3. EPA determined that relaasaa of PCBa lo tha environment and expoaura to human* and biological organism* from mineral ol) transformer* are mtmmal. EPA estimated that theae traniformera contain leaa than 0.15 percent of all tha PCBa uaad in transformer* and release less than one* half of a percent of these PCBs on an annual basis. 4. EPA determined that Ih* costs associated with other risk reduction measures such as accelerated phsse-oul. reducing the PCB concentration in ths dielectric fluid, or providing containment for transformers wars not reasonable when compared to th* potential reduction In release of PCBs achieved. In evaluating ths risks posed by lha ' continued us* of electrical transformer* containing KBs, EPA had considered HONS 214109 Federal Reglator / Vol '48, No, 58 / Friday. March 23, 10&4 / Proposed Rule* 11071 the exposure resulting from leak* end polychlorinated dibentofurene In tha pill* of PCB containing dielectric fluid ductwork of the building. s constituting the principal route of release of PCBi to the environment for this equipment, There wee. however, en Indication that Area involving trenefomtere elao could be responsible for the release of PCS* For example, on February 1,1061, in the Binghamton State Offloe Building In Binghamton. New York, e PCB. Transformer was involved in a fire tn the basement of the building Monitoring, completed after the fire. Indicated (he distribution of PCB*. poiychlorinatsd dibanzofurant, and polychlorinated dlbe mod toxins throughout the interior of the building. The distribution of PCBi (end euepecled oxidation products) throughout the 13- The Sen Francisco Incident, and en even more recent Incident, in the First National Bank Building In Chicago, Illinois in September ism, have prompted EPA to consider reassetaing lie earlier poeitton on theaxpeeled frequency of firo-eeltled incident* Involving transformers that eontain PCBe ' This Advance Notice of Proposed Rulemaking (ANPR) ts the Agency'* first tep In formally eiMesing Ihe public hseltb and environments risks posed by fires Involving electrical transformers containing PCB*. If EPA determine* that th* H*k* posed by Dree Involving transformer* that contain PCB* *re story building occurred vie two vertical sufficiently large, when weighed against ventilation shafts that ren the length of the benefits of this equipment and tha the building end opened Into the coils of oontrol measure*, then EPA will transformer vault In the basement. At propose meaeuree by October IBM to the time, however, EPA believed that reduce or elimlnete theee rieke. fires Involving transformers that contain The pwpos* of this ANPR. then. >* to PCBs were rare. Isolated event*. Tbu*. present certain aveUabi* Information on although EPA mod* determination! that, * she risk# poaed by dm tnvolvtng the uae of electrical transformer* Vansforman that contain PCS*, and to containing PCB* did not pose olJcft data In five major treat'. (1) The unreasonable rieke lo public heeltb or the environment. EPA did not directly consider the public heelth end environmental rieke poted from Un related events. EPA aleo did not evaluate the cost of Implementing risk reduction meeeures to mitigate the risks posed by fires Involving this equipment or factor into Its economic esseeement risks posed lo human health and the environment tn the event of firerelated accident involving en electrical transformer containing PCBe; (2) tha probability of flra-relsted event* occurring that involva alectrical transformer* that contain PCBe, and factor* that may tneraaae thia . eerie tn now-identified coete associated probability. (3) tha reaction* and with the continued uae of these mechaniama of reaction* Involved In the transformers, principally, the high coete formation of PCDFa end polychlorinetad of cleen-up following these incident*. . dlbenzodioxtna [PCDDe) tn fire-related These coete reduce the benefit* Incident* Involving electrical associated with the continued use of tranaformera containing PCBi'. (4) tha theee transformers. cotta and nature of th* cost Incurred by After promulgation of the 1B82 rule, th* ownar of a transformer Involved In a additional Information cam* to EPA'* flre-relatad event; and (3) the attention the! Indicated that PCB- Identification of available option* for Trenaformer fires mey occur more mitigating or aliminating the rieke poaad frequently then previously expected, by fire* Involving electrical tranaformera nnd that PCB-Trineformer fir#hazard* containing PCBe ae wall the coete and arc not restricted solely lo traiufonnsn banaflte associated with thoea option*. Ideated inside buildings. On Mey IS. 1983. In (he On* Market Plaza complex in San Francisco. California, e PCBTreneformer we* Involved In t smoky transformer vault fire Monitoring completed after the fire Indicated the presence of PCBe end polychlorinated dibentofurene (PCDFej In soot from this fire Although the vault housing tha transformer wee located exterior to the building Itself, unsealed conduits front the vault to the basement and outelda air Intaks venlt drew the contaminated moke Into ihe building end allowed for If EPA ia not provided with adequate ' dele, especially In the ereee of Ihe rieke posed In ths event of fire, the probability of theee flree occurring, end the cost* associated with cleen-up following theee Incident*, EPA will make its regulatory Judgment* bated upon the date set forth In this document TTteee dels Indicate that PCB- Transformer fires pose relatively high risk*, occur with unknown frequency end cen result tn relatively high cleen- up costs. * Ihe distribution of the PCBi and IL Transformer Fire Rieka / A primary source of information on the cause* of aad circumstance* surrounding flree tnvolvtng transformer* containing PCB* are date compiled from three PCB-Transformer fires in Binghamton. New York. Sen Francieo. Californie; and Chicago, ilhnole In order to endaraUnd better the rieke posed by the.uee of this equipment In the event of a fire. EPA has evaluated tech of these incidents, end oompared the dreumetenom urmnding each fire In order to determine what factor* Increased tha rieke posed from the fire, and what factors, if any, reduced the Hike presented by the fire. EPA eeumes that Ihe risk* posed by fire involving a PCB-Trantformtr are related to ih# decree of diapertlon of toxic chemicals from the transformer Into areas where people mey be preaent Thus. EPA expects that PC8Trensfomer fire* In buildings or near building* nuy poee greeter risk* than PCB-Trenefomer fine In location* such a outdoor alectrical aubatatione. The Agency further aeeuinea that tha greater the dispersion of contaminant* within a building, the greeter the potential for exposure of humans lo thee* contaminant*, and therefore, the higher the rieke EPA hee reached ceritln conclusion* about the rieke poeed by transformer flree. based on theea three case atudiaa. The three Incident* discussed below re the three moat well-cheractarizad and wet]-researched Incident* that EPA I* aware oL EPA I* soliciting similar Information on ether ftre-related Incident* Involving transformer* containing PCB*. A partial lilt of other lea* wflt-known and lets wellresearched incident* that EPA le aware of appear* in Unll 111 B EPA la aollcfUng additional Inform* lion on the** incident*, at well * Inform*lion on other Incident* nol Included on this list 1. Binghamton, New York. At 3 30 a.m. on February S, 1981. a fir* occurred la the (wltchgear adjectni to a PCBTranaformer In tha baaemant mechanical room of tha Binghamton State Office Building Utie building ie an 13 atory office lower that wee completed In 1873. Power to tha building was supplied by two transformer* which contained a coolant fluid conalatlng of U percent PCB (trada nsma Arodor 1234) and 35 parcant mixed tri- and tetrachlorlnatad bamanea. Although tha city fire department* responded within minute*, they did not enter the medianlctl room until the power wee disconnected to the HONS 214110 11072 Federal Raster / Voi. 49. No, 86 / Friday, March 23, 1064 / Propoted Rule* trtnaformera approximately 50 minute* [ter the tire etarted. During thla period, there wae repeated electrical arcing and report* of loud axploaloni occurring in the mechanical room. Smoka generated by the fire wea distributed by convection throughout the building through an open vertical ahafi that aiarted In the mechanical room and ren to the penthouse. Thle concrete block haft contained the sheet metal duct for the exhaust air from the men's restrooms on sit the floors. The shaft was not sir tight, and allowed smoke to escape the apses between the structural ceiling and the suspended celling on each floor of the building As a result, the entire Inside of the building wee coiled with bieck soot. The prob eble eource of the soot was combullion of ths materials in ths witch gssr. The hset of ths firs sppersnliy ctused s ceramic bushing to crack on ons of ths transformers, Mowing approximately 100 gallon* of insulating liquid to drain onto the floor In the vicinity of ths fire. Photographs Is ken shortly eftsr the fire was extinguished ehowed that tha awltch * * gear wee completely destroyed, but thera wae Httla damage to the transformer*? Tha mechanical room was heavily coated with aoot, and puddle* of liquid ramalned on the floor. The heal from the fire wea sufficient lo damage lightly a atructural ateel beam that was directly over the ewltch gear. However, tha fire apparently did not apread to any material other then the awjtch gear lieelf. Elevated levels of PCDFa in ths aoot were reported within a week after the fire. Comprehenalva analyses of ths eoot were performed by Dr. David Stalling of the U-S. Fish end Wildlife Service. Columbia, Missouri, by Dr. Chrisiepher Rsppe of ths University of Umea In Sweden, end by Dr. Pet O'Keefe of the New York Stele Department of Health Leboretoriee. Theee analyte* reported the presence of PCDD*. PCDFe end polychlorinated blphanylenaa [PCBPe). although the amounta found varied from ample lo ample. Initial analyaaa of two tool aamplea by Smith at ol (Ref. 1) reported the presence of 2 8 and 2.9 ppm 2.3,7 9-iatrachlorodlbcnxo-p-dlpxin (2,3.7,9-TCDD) and 324 and 273 ppm 2.3.79-lelrachlorodlbenxofuran (2,3,7,8TCDF). A more detallad enelysla of a homogenized mixture of tool takan from throughout tha building and used in animal feeding atudlea contained 7900 ppm PC8s end the following concentraiione of varloue homologe of PCDF: tatra-18 ppm, penle-2t ppm. hexa2 ppm. hepta-3 3 ppm. and oclt-0.74 ppm Analysis of a tingle aoot ample found 597 ppm total tetra-chlorinated dlbentofuran, 48 ppm 2.3,7,8-TCDF. 3.8 ppm lot*] letra-chlorinated dibenxodioxlna, and 1.2 ppm 2,3,7,8- TCDD. Congener apeclflc analyala of a difTarent Binghamton toot tample found 2.3.7.8 aubatltutad conatituenta to be the moat predominant conganars within ach of the lavela of chlorination of both PCDFt and PCDDa. Additional gampting data on PCB, PCDp and PCDD level* found following the Binghamton fire, well additional Information on tha clrcumalancaa aurrounding thla Incident re preaahted In the Verser report "Expoaure Assessment- Fires Involving PCB Treneformere" (Ref. 1), The Binghamton Stele Office Building remelne closed to nonnel uee. The building hee been extenelvply cleaned by vacuuming end weehing to remove the eoot Analysis of eir atmples. wipe ample* from vinyl welle. and bulk ample* of aprayed-on ceiling insulation have demon* treted that the ratio of the verioua toxic constituent* la not oonatant from one matrix lo another, end that the vaporization end redepoeltlon proceeaaa ere causing gradual redistribution of ths mstsriel within ths building. Betimstss of clean up oosts to date ere between BIS end (20 million. 2. Son Froncitco. Cotifomia. Shortly after 31-00 in on May 18,3983, Are aiarted in the eub-beaemant transformer vault of the One Market Plaza office building complex el the comer of Steueri end Mission Strsete in San FrencJtco. The vault contained three transformers thst wars filled with Aroclor 1242 coolant liquid. Heavy black moke Iseued from the eldewetk grating adjacent to ths building for about thraa hours until tha high voltsga power to the transformer wes Interrupted by the utility. During this threa-hour period, there wes considerable vibration and loud noieee accurring in tha vault that wars described by reporters at ths sosne s "explosions." No information is available on the site of the transformers, but 11 was reported thst only one transformer leaked, end that sfler the fire there were 50 to 80gallon* of liquid in the vault, with the floor and walla of tha vault caked with black soot and liquid* dripping from tha vault coiling The liquid remaining in the transformer contained 0.327 ppm tetrechlorodlbenxofuren (TCDF) end no de (actable telr echlorod tbsnxo-p-djoxin (TCDD). Smoke and soot from ths transformer vault contaminated ihe adjacent switch gear room (through the bus duct) end smell areat of the adjacent perking ' garage end workshop erees (through mall crick* In the concrete block vault 'walla'), Soma of Ihe heavy smoke Iseuing from the eidewalk grating was apparently pulled Into tha building through alraal laval air makeup louver* and into tha ventilating fan* that aupply lr through tha aub-baaement. basement plan level, and floor* 2 through 8 of the Stauart Street office tower. Teat* later indicated that the contamination wee limited to Ihe beaemanl, the elr handling y*t#m through floor 8. end the exterior of the building. The upper floor* of die Stauart Street Tower receive air from ventilating fane mounted In a penthouse above tha 26th floor. Air aamplea Ukan In tha vault alerting week after tha fire measured 320 to 3500 micrograms par cubic matar PCS*, depending on tha reta of vanilla lion through tha vault. (Ambient levels of PCBs in tha atmoaphare have been meeaured and rang* from about 0.1 to 9 nanograma per cubic meter.) The awjtch gear room ad|acant to tha vault had air concentration* high 98 micrograma per cubic meter before ventilation waa tartad, Tha Ban FTanclaco Department of Public Health reatrictad aoceaa to any area having a laval of PCBs In tha air in xcaaa of 3 mlcrogrem per cubic meter, or aurfece contamination in exceea of 3 mlcrogrem PCB* par 100 square centimeters when sampled by wiping with cloth wetted with octane. Although no tunplaa collected in the office* on floor* 2 through 9 ware contaminated above thaaa laval*, tha city requeatad that tha ventilation yatam not be operated becauae of the possibility of aproading contamination to theae dean arata. without ventilation, thaaa floor* could not be occupied. Anelyala of the toot collaclad In the Lranaformer vault and In tha aubbaaement adjacent to the well of the trenaformer vault allowed the presence of PCBa, TCDFa, and TCDD*. A aoot ample taken adjacanl to tha vault howed tha preaenca of 88,000 ppm PCBa. 28 9 ppm .otal TCDFa (6.3 ppm 1 3. 7. 8-TCDF). and 0.324 ppm TCDD (0 059 ppm 2,3,7.8-TCDD). Additional sampling data on PCB, PCDF. and PCDD level* found as a remit of tha San Franclaco fir* are presented in tha Varaar report (Ref. 1). The available report* on the analytic*! result* from One Market Plexa do not apecify tha analytical procedure* nor. in motl caaea, tha detection limit* of tha procedure* used. However, from a compartion of available information on iha contents of Ihe treneformer and tha amount of fluid pillad, and tha laval* of contaminant* measured, it la apparent that tha HONS 214111 Tadarel Register / Vol. 49, No. SB / Friday. March 23, 11184 / Proposed Rules tl0?3 conversion of PCS* lo PCDF* occurred with about tha aarne efficiency in both Binghamton and San Ftanciaco. Estimate* of clean-up ooata to data (provided by th* Pacific Caa and Electric Company) r* between til and 120 million. 3 Chicago. Ulinoit. On September M, 1961. a Bra occurred In a bua bar bctwaan a PCB-Tranaformer and tha witch gear In a transformer vault ander tha plata on tha aama blockaa tha Pint National Bank Building In Chicago, llUnoia. Although powar to tha tranafonaar waa cut after about 10 minute*, amok* continued to Itaua from tha ildewetk grating for about 45 aolnulaa. Impaction of tha transformers aftar tha Ore waa axtlngutahed indicatad that ona of tha four trenaformera In tha vault had leaked approximately 15 gallon* of coolant conflating of 55 parcant Aroctor and 35 percent chlorinated benzene*. 151% aource of the leak waa a email hole In the tranafonMr caelng that waa poaaibly cauaad by electrical arcing Significant PCB eon lamination wag limited to tha vault, tha axhauet air >, duett from tha vault, and to tha exterior urfecea of a email building adjacent to the traniformar vent. Tha highaat reading! outaida tha vault and Ita ' txhaual ayalem wart on a window ata/ tha vault (497 mlcrogrtma par 109 square centimatart) and on an intake air wall grille {752 microgranu par 100 equate canllmatara) and window (398 microgremi par 100 square centimeter*). Tba traniformar veuli waa adjacanl to an underground perking garage and ihartd a ventilating ayalem with the garage and a imeU adjacent building; nowtvtr. none of theta area* waa heavily contaminated The Flrat National Bank Building, about ona .half block from tha veult, waa not contaminated, Although one fiberglaia filter on en air Intake vent on the fourth floor of the Flrel National B*nk Building waa found lo contain bout 90 ppm PCBa, nearby filter! did not thow high lev*!*. The building wae evacuated when amoke wae teen coming from window vent; however, the imoh* waa laltr Identified aa tha exhauel from an auxiliary dieaal generator that itarted when power we* ihut off to the traniformar*. No aneiytei were reported for PCDF* c- PCDOi In th* aoot A number of wipe (ample* were collected in the Flral National Bank Building and from tha air aupply Intake near tha traniformar, but no PCDF* or PCDDi were found. The First National Bank Building waa evacuated at the time of the fire, but reoccupied the following day. Cleaning kui limited to tha transformer vault. Ita axhauet ayatem. and the axterlor of the email building next to tha vtulL B Concluitont Bated on Cota Studies Baaed upon BPA'a evahiatltm of the dmanetance* numunding tha Binghamton. New York; San Francitco. California; end Chicago, Illlnnla Area. CPA beiievea that Area Involving PCB- Tranefonner preterit certain riaka of axpotura of human* and tha ~ environment to toxic contaminant* auch ` ai vo!tLilted PCBa and wrteln oxidation product* of PCBa. Including PCDF. 1. Toxicity ofPCB* and oxidation productt found In eoot In oarllor rulemaking*, EPA baa already concluded that, baaed upon available information, paraon* exposed to PCBa can develop chtormcnr and. that baaed on animal data, thora la a potential for reproductive affect* and developmental toxicity ea well ea oncogenicity in hument exposed to PCBa. Although tha effect* of ctitorecn* are revertibie. SPA doea not oonaidar thla effect of axpoaure to PCBa to be hwlgnlflcant (Raf. 2). According to tha September 12.1M0 Carcinogenic Aeaeaament Group'* (CAC'e) Riak Attnunant on t,3,7.8TCDD (Ref 9), yuaged by reaalt* of toxicity testing In animal* for a variety of efTecta, 2.5.7,5-TCDD fa ona of tha moil toxic chemical* known. Till* aubatanco waa found In aoot eamplea taken following tha Binghamton andSan FrancWw tranefonner fire*. LD velue* of Z.3.7.5-TCDD renge from 0.9 mlcrograma per kilogram orally for tha mala guinea pig to STSmicnwruit oar kilogram dermally for the rabbit, which would dattify thla compound aa tupertoxlc (Rtf. 4). (The acala of acuta toxicity rangea from practically nontoxic lo eupertoxlc.) Dtatha typically occur about ona week or more after treatment. In chronic and acute orel 2.3,7,8-TCDD toxicity vtudlea on several enimal tpaclea, the liver, thymua, and tplaao have conatatantly bean tha target organa. Uver damage. Including necrotic and degenerative change!, lipid accumulation, and Increaaed tlvar weight have been observed Ln mica, rala, and guinea pig* following 1,3,7,8-TCDD treat manU Atrophy of the thymua and apleen he* alio conilitently been found In laboratory anlmeli Other effect* ot 3.3.7,4'TCDd Ingeatlon Include euppresilon of reproduce v* function In rat* and disturbance* of th* hematopoietic ayetera with occasional hemorrhaging in monkeya, rala, and mica (Raf. 3| Ther* are aeveral cancer bloaaaay etudie* of 2,3.7,4-TCDD: {1) A Dow Chemical Company study (kociba ot oh 1975} in mala and tamale Sprague PewJay rata; (2) the Van Millar ti of. (1977J itvdy fo male Sprague DewUy rate. |3) the Toth et cl (1979) study in Swlaa mice, (4) the National Cancer (netitut* (1980 a, b) etudrei in rata and mice; (8) the Pjtot et al f1980) promotion tudy In rata; and () the Kouri et of. (U7g) oocarcfnoganicily study in mice (Ref. 3k In summery, aocotding to lha September I960 CAC riak at*eaamant (Ref. 3), oarefoogenic reeponaei have been lnduoed In mica and rata at vary low dote* of 2JL74-TCDD. In addiUon. XX7.4-TCDO hat bean shown to be a very potent cancar promoter. These reult*. together eritb auggeattve evidence in epidemiologic atudiaa. eonititut* eubetaatial evidence that 13.74-TCDD 1* likely to be a human cardnogen. In addition, on the beat* of a Dow Chemical Company study on 2.3.7,8-TCDD, II appear* that 23.7,8- TCDD I* a more potent carcinogen than fletoxln B, which le one of the moet potent carcinogen! known (Raf. 2). Toxloologleel testing of polychtorineted dibenzoferan* (PCDF*) has been more limited then testing of 23.7.5- TCDD. However. In a study deatgned fo cvehiat* the eoropermtiv* toxlolty ot PCBa end PCDFa, In rata, PCDF* wan found fo be mot# toxic than PCBa (Ret 5). In particular, the result* of thla study indleala that PCDFa produced atvera toxic effects on hematologic end thymfo function*, to ret* fed diet* containing polychlorinated dibanzofurans. severe redaction In erythrocyte counts, hematocrit, and hemoglobin concentration occurred, end blood eater* Indicated hemolytic anemia. Following th* Binghamton fire, several naearchert completed lexicological tatting of loot lamp!** In guinea pig*. Baaed on theaa atudiaa uting Binghamton Stall Office Building (BSOB) tool EPA haa concluded that multiple rxpoaura* to aoot from PCB- Trantformer fire* have tha potential lo roduct toxicity in the thymui, tha emitopoletic ayatem, the atllvery glend duct epithelial and, poaaibly. tha fiver (Raf. 0). It it worth noting that thymic atrophy, bon* marrow depletion, and dlmlnlehed body weight gain, all effects of the aubchronic administration of tha BSOB eoot have been routinely demonstrated in acuta studies in guinea pig* using PCDFa and PCDDe (Raf.). in addition, tha group of guinea piga doaed with 231.1 ppm BSOB loot In hi *ubchroiaic tudy exhibited symptom* characteristic of acute exposure to 2,3,7,4-TCDD and 2.3.7.5- TCDF which include akelatal muscle degeneration, fatty chenge* In HONS 2L4L12 11074 Federal Register / Vol. 49, No. 56 / Friday, March 23, 1984 / Proposed Rule* hepalocytaa, and degeneration of lempereture. Thet ie, the fed that lea* gaitrotnteatlnal tract epithelium (Ref. 6). PCB ia present meene only the I i**a tote) One paper elated that the oral LD of PCDF will be formed etnee low the BSOB aool in guinea plga la 410 concentre Hone alone are not expected lo mtlllgrama per kilogram body weight heve any affect on tha reaction rata, (Ref. 6), which would claaaify thla machanlam of reaction, or product yiald. compound aa vey toxic (Ref, 4), 2 Ditcuti/on offormation of oxidation product* from PCBs There fa There elao appear lo be few fectore preeent tn en uncontrolled flreeltuetion which would ceuee the total deetmction direct evidence of the formation of PCDFa and PCDD* from heating and of PCBs and PCDFa or which would preeent other competing reactions to burning commercial mlxturea of PCBa reduce tha yield of PCDFa. - and dlluenta The direct evidence ia An uncontrolled fire of sufficient from: (l) Laboratory axperimenta temperature (ebout BOO'C) to bum publiahed in chemical and other material* containing PCB* can result in literature, and (2) chemical enelyaea of the formation of PCDFa ea large aa a ,, maleriela at the altea where fliea ware percentage of tha laval of PCB* known to involve tranaformera that originally present In the material. contained PCBa PCBa, PCOFa, and Concentration* would vary with th* PCDDa were *li found tn aome aoot volume of contained combustion gate* apeclmena from both the Binghamton or constituent* of material containing and San Franciaco flraa. (PCOFa and particulat* eombuaUon solid*. Although PCDDt were not analysed for in the aoot high temperature Incineration ia uted lo from the Chicago fire.) dispose of PCBa In oil, PCDFa and Laboratory itudiea provide the beat PCDDa have *tao bean dalactad available Information on the converaion following th* incineration of PCB* in oil. of pore PCBa to PCDFa. In thtte atudiea, Incineration of PCBa require* at 1200'C a number of different PCB congbnerq temperature, e two-second residence and mlxturea of congeners have bean . time, end sufficient oxygen. A* heated and the resulting materials * explained abova, however, laboratory entlyzed for all PCOFa and PCDDa. axperimenta indicate that th* reaction Since a ipectfic PCB compound reacts to temperature for th* formation of PCDFa form a limited number of PCDFa, the ia optimised at around BOO'C. formation of PCDFa Involves Commercial mixture* of PCB* intramolecular elimination of three frequently contain mlxturea of klnda of diatomic molecules, with or chlorobenzene* aa wall a* PCB*. Evan without tome rearrangement of chlorine "pura" PCB may have low 1 atomi on the remaining phenyl rings. concentration* of chlorobanzenea From the products obtained in the PCB resent ea contaminants. Experiment* reactions, the diatomic molecules, *v* shown th* formation of PCDFa and hydrogen, hydrogen chloride, and PCDDa from pyrolyala of mlxturaa of chlorine, are formed from one hydrogen chlorobeniane* In air Other chlorinated and/or chlorine atom in ortho positions compound* including chlorophenola on each of the two phenyl rings. The war* also formed. Amount* of PCDFa optimum temperature range for the ranged aa high a* tan the of a percent for published laboratory experiments was mlxturea of trichlorobanxenaa. Tetra- 000`C. Yields of PCDFa are in the - and pantachloro-bentana mixture* ` percent range from 550'C to 000*C. but formed amount* of PCDF* and PCDDa drop off to tenths of a percent at BOO'C which were two order* of magnitude and 650'C, smaller than th* amount* of tnaae The description and characterisation compound* formed by trichlorobeman*. of the chemical reactions occurring in a PCDF* and PCDDa may also be formed flra in which aroclora (or any other from th* chlorinated phenol* observed commercial mixtures of many PCB ' in tha pyrolyala of chlorinated benzene*. compounds) era burned fa far ntora The reectlona to form PCDFe and complex than the laboratory PCDDa era bimoiecular and tha experlmanle However, the earns axperimenta! concentretiona of reactions observed in the laboratory chforobanzane* war* high. Tha reduced should also occur In flra ailuationa concentration of chlorobanzana aa a where the reactants and reaction contaminant in commercial uses of PCB* conditions are similar lo laboratory would probably nol lead a substantial reaction conditions. Since the laboratory Increase* In the amount* of PCDFs and reaction that result* In th* forma lion of PCDDa formed from burning or hasting PCDFa from PCBa I* intramolecular and the PCBa. The nolebte exceptione are an elimination, th* affect of lower commercial malarial* using concentration* of PCB* (auch a* thoa* chlorobenzene* a* a aolvanl for present in mineral oil transformers) concentrated PCBs, t.e., aakarela. EPA hould have a minimal affect on th* _ beltevaa that the PCDD laval* found in reaction rata or product yield el given ` the Binghamton eoo! aemplaa resulted from tbe oxidation of chlorobenzene* Tha low level PCDDa found following the San Franciaco fire could have been aaaociatad with lha possible praaanc* of low concentration* of chlorobenzene* in the fluid, from peat servicing operations Information ia not avatlqbie on the products resulting from pyrolyzlng chlorobenzene In commercial use* of PCBa. at different temperatures, tn the renge expected to be formed tn uncontrolled burning ` With respect to possible burning or heeling of commercial PCB mixture* at low concentre Ilona In mineral oil, tha flath point and fire point of tha oil might Increase the chenoea of having a fire alert and, ones an oil fire atari*, it ia not unexpected that auch a fire would provide suitable reaction condition* for producing PCDFa and PCDDa (if chlorobenzene* arapresent) from ' commercial PCBa, TH* flash point* and fire point* of both mineral oil and silicon* oil could permit tha heating of dissolved or dispersed PCBa to temperature* comparable to th* temperature* uaad In publiahed studies of thaa* reactions- Thu*. EPA expect* that mineral oil equipment and other type* of equipment contaminated with PCB* may also poae certain riaka In tha avant of a fin from tb* perspective of the formation of toxic pyrolytic product*. ' Compared lo miner*! oil, tha tower flash point and fir* point of silicone oil* (a potential aubttituta fluid for retrofitting PCB Transformers) might reduce the chance* of having a fir* atari. But, ones a silicon* oil fir* starts. It ia not unexpected thet auch a flra would also provide suitable reaction condition* for producing PCDFa and PCDDa (whan chlorobenzene* art present) from commercial mixture* of PCBa present tn tha transformer* *1 low concentrations, EPA la soliciting information concerning tha identification and quantitation of residual chlorinated aromatic hydrocarbon*, resulting from exposure lo open flam* burning of commercial formulation* of transformer fluid* containing PCBa and other chlorinated aromatic hydrocarbon*. EPA ii also aoliciling information on condi tiona actually present in transformer location*, other than open flames, that can lead to tha formation of residual chlorinated aromatic hydrocarbon*. EPA It also soliciting information on substitute fluid* ana th* chemical residue* present following burning of these melariala. S. Populations ol rmk from PCB- Tnnsformorfirot. From it* analysis of tha three flra* in Binghamlon, Saa Franciaco. end Chicago, EPA haa HONS 214113 Federal Register / Vol, 49, No. 56 / Friday, March 23. 19M / Proposed Rule* 11075 identified el* populetion* thet mey be et building* that when they occur In type* of building* Fire* Involving PCB- risk in the event of e fire involving PCB- outdoor location* auch ** electrical Treneformer* et Industrie! facilities mey Treneformer* The flret group ere eubetatione From this preliminary pose lesser rieke, because fewer pereone pereone preeent in e building or pouibly entlyeie, ii eleo appear* thet one of the ere generally present end EPA expect* in en edjeceni building el the time of e primary factor* thet contribute to the thet these treneformer* ere often in fin. The eecond group are firemen end riek* noted by Are* Involving' piece* thet ere toon open, where any other emergency reeponee pertonnel trenefomer* that contain PCB* In malfunction* would be rapidly reepondlng to the fire. The third group building* in the preeence of ventilation Identified. EPA solicit* comment* on the ere onlooker* preeent during the eh* ft* or ductwork In the vicinity of t reletiv* riek* posed by treneformer* extinguishing of the fire, end the fourth treneformer that t* Involved In * fir*, in located In office building*, shopping group ere pereone involved in the clean both Blnghemton and San Frandtco, mella, hotel* and motel* versus up following the fire. The flnel two ventilation equipment or ductwork In transformer* located In Industrie] groupe ere pereone reluming to the the vicinity of the trantfonnar* facilities or electrical eubeietJon*. building following elatn-up, end, significantly contributed to the Finally, EPA believe* thet there I* one pereone expoeed to equipment, diipertlon of PCB* end oertein eutomobllee. etc thet mey heve been oxidation product*. Including PCDD end contemfneted during the Fire. PCDF Into the building. In addition to theat incidante posing A eecond factor that appear* to certain rieke to pereone preeent in or Increeee the riek* posed by Are* around buildings involved in thee* Area, involving PCB-Treneformer* I* the EPA bellevee that thee* incident* mey failure of protective device* auch at eleo poe* riek* to other populetion* end circuit brttker* to Interrupt the flow of to the environment. Specifically, electricity Into a treneformer. in both depending upon the location end Binghamton and San Frandeco. there 1* frequency of thee* incident*. EPA evidence thet tugged* that power believe* that the diecherg* of . continued to be provided to thee* contaminated weter (ueed to contain treneformer* for eom* Um* after the thee* fire*] containing PCB*. PCDFe, end Initial malfunction. There 1* apeculetion PCDDe Into the water eyetem could po'ep that thin factor contributed to the certain riek* to other populetion group* * formation of additional toxic pyrolyet* * well. EPA I* epeclflcelly eoticltlng product*, by creating axe*** nett and del* on the rieke noted to hument end other condition* condudv* to the the environment from the diecherg* of formation of thtea oxidation product*. water ueed to contain thee* flret. EPA A third faclor that appear* to Inert*** to!Idle Inform*Hon on other potential populetion* thet mey be et riek In the the rieke poeed by Art* Involving PCB- ` Trantfonnar* If Amman being unaware event of * fir* Involving t treneformer thet contain* PCB*. that they art reepondlng to a Are Involving a PCB-Treneformer. in both f Potential for expatun to PCB* ond Blnghemton tnd San Frencieco, there 1* oxidation product* from fin*. evidence to tugged that the Bremen Monitoring for PCB*. PCDFe and/or who Initially reaponded to the Are* wtr* PCDDe we* completed efter the not ewer* that PCB-Treneformer* were February ft, 1001 Blnghemton fire, the involved. Thue, thet* Bremen mey not Mey 10,1901 Sen Francisco fir*, and the heve followed certain precaution* that September Zft. 1003 Chicago fir*. PCB might be coneldertd to be appropriate contamination we* found in *11 three given the potential rieke poeed In the Incident*, end PCDFe end PCDDe were court* of extinguishing auch a Are. For Identified In aoot temple* from both the example, Aimed eecount* of the Sen Blnghemton end Sen Frencieco flret (*** Frendtco Are Indicate thet haevy black Unit 11 A. for tummtry of templing smoke poured out of the underground dele). sidewalk vault housing the PCB- Sampling dele accumulated following - Treneformer*. Thee* etmt Aimed the Binghamton fir* dearly Indicate* the account* indicate thet reeplrttory potential for exposure to PCB*. PCDFe, protection wee not used by Bremen end PCDDe by firemen, building present above the treneformer vault occupant*, end other* In the vicinity of a during their response to the Are. Further, PCB-Trensformer fire. Sampling from the these filmed account* eleo indicate the Sen Frencieco fire eleo aupport* a preeence of eeveret elmilarty - determination thet PCB-Treneformer unprotected civilian onlooker* In the fire* pose certain riek* of expotur* to PCUe. PCDFe, and PCDDe. ere* during the extinguishing of Ih* fir*. A related rector that mey be relevant EPA eoltcit* additional del* on PCB, to the degree of riek poeed by Are* other factor that may increase the risk* poeed by PC8-Ttan*fonner Are*, Thla factor 1* the lack of knowledge on the pert of many parson*. Including Bremen and other emergency response pertonnel, State end loce) authorities, and person* occupying that* building* about the potential riek* posed in the event of a Are Involving treneformer* thtt contain PCB*. in Blnghemton, Ben Frencieco. and Chicago, little structure! damage occurred to the building* ** * reeult of thee* Are*. For the moat part,' damage wee limited to tmokt demeg*. In thet* case*. * conscious decision wet mad* by authorities el the scene to analyse for the pretence of PCB* and cart* In oxidation products before allowing r*-ooeupency. Without this decitfon on the pert of authorities present at tht teens of other tlmller fires. It It possible thel thtt* other building* mey have been prematurely re-opened for occupancy. Pert of the reason for thla genaral leek of knowledge about the risk* posed in the event of PCB-Traneformer Art* mey bt the lack of a coordinated effort to accumulate Information on similar Brae whan they occur. Currently, there ie no EPA requirement that Are* Involving PCB-Trtnaformart be reported to the Agency. EPA solicit* comment* on the, benefit* of maintaining an EPA PCB- ' Treneformer Fir* Reporting eyetem a* wall a* comment* on other mechanisms for Informing people of the hazard* poeed by these Incident* EPA also solicit* Information from knowledgeable perils* on He analysts of whet feclor* increeee the risk* posed by fires involving PCB-Treneformer* ** welt a* comment* on other factor* retent during the Binghamton, Sen rendeco, end Chicago fire* (or other flreel thet mey have Incretitd the risk* poeed by thee* Are*. PCDF, end PCDD level* meetured Involving PCB-Treneiormar* i* the type ft. Factor* that appear to have following PCB-Treneformer fire* of building In which the transformer 1* decnoted the riek*poeed by fine. EPA ft Factors that appear to increase located. EPA believe* thet PCB- believe* thet other feclor* mey exist neks posed by fire*. From EPA'* Trtneformer Area In office building* and that In contrast to the factor* listed preliminary analytic, it appear* thet shopping melt* mey poe* greeter risk* to above, limit the risk* poeed b PCB- PCB-Treneformer flret may pot* high the public, because of the concentration Traneformer Are*. That is. although the rUke when they occur near or Intid* of people normally preeent (n thee* Blnghemton end Sen Frencieco Aral are HONS 214114 11078 Federal Register / Vol. 49, No, 68 / Friday, March 13, 1984 / Proposed Rulea com I da red to poae certain riaka, both of I III. Probability of Fbe* Occurring these site* are office buildings, 13 are theie Incldenli had the potential to poae 1 Involving Transformer* That Contain much greater rlaka For example, one (-in - -r chopping mails, 5 are induatriet facililiea, end 3 are holela or motel* factor that limited the rlake eaeoclated with the ftree In Binghamton and Ban Fraoeiico wea the time of the firea. Both Area occurred during period* when theae bulldingt were, for the moat part, unoccupied In contreal, the Chicago Are tn September 1963 occurred In the Flrat National Bank Building during a period of high occupency. However, in thla Incident, power to tha Ireneformer wae nif after about ten minute*. In Binghemton and San Franciaco. the tranaformara remained anerglxad for 10 minutea and three houra, reapectivaly. EPA la aolictlng information on other fectora that may heve mitigated tha rlake poaed by firea involving PCBTrenaformara. C Cleon-Up Costs Following PCB Transformer Fires Given tha well-aatabliahad toxicity of PCBa. and the preaanca of malarial* that are more toxic then PCB* in the eoot ' from a Are involving a PCB-Trana formek owner* of PCB-Tranaformara involved In PCB-Trenaformar Area hava Invaatad up A. Tht Number and Location of Transformers Containing PCB's 1. Aiio contained in the August ts, 1982 rvlemaiing record. Tranaformara are uaed axtenaively by electric utillliaa end other induatriet to trenamlt end diatrlbute electric power efficiently. Some trenaformar* daalgned for uaa with PCB* contain between 80 and 70 percent PCBa; other*, daalgned to contain mineral oil dielectric fluid ere contaminated with PCBa from peat aervicing and manufacturing actlvttle*. An aatlraata of tha numbar of utility owned PCB-Tranaformer* waa previously provided to EPA vie an Ediaon Electric Inetituta and UtHldae and Solid Weata Adviaory Group (EEl/ USWAC) aurvey of tha utility induatryThaaa data war* preaentad In tabular form in tha Propoaad PCS Electrical Uaa Rule, published In the Federal Register of April 22.1982 (47 FR17428). In tha Auguat 25.1882, PCB Electrical Uaa Rule, EPA uaed theae data, in combination with axiating data from an arlier rulemaking to aatlmata tha total number of PCB-Trentformer* in service Over 00 percent of the PCSTransformers Hated in thie limited survey era owned by utilities (Ref 8). EPA believe* that the etlimetei of Ihe number of {n-aervlc* PCB-Transformer* uaed In the Auguat 25,1082 rule era alill valid today However, In order to evaluate fully )ha bazarda poaed by Area Involving transformer* containing PCBa, EPA need* more detailed Information on PCB-Tranaformera. Tha data needed include data on: (1) The type*.of building* In which PCB-Tranaformera are uaad, (2) tha numbar of PCBTranaformar* uaed in each building, (3) tha age* of the tranaformara, (4) the ages of the buildings, (5) tha location of the PCB-Tranaformera asrvtng the building*, and (6) tha ownarahip of tha PCBTranaformera. EPA solid)* Information from other building owner* similar to that provided by Equitable Ufa Aasursnca. aa wall aa from Stale and local municipalltlat. EPA also solicit* information on the costa of requiring PCB-Transformer owner* to report to EPA the number and locations of PCB-Transformars- to S20 million each to enaur* the eefety and to eatimata tha diatribution of thaaa B. Result* From a Surrey ofEPA of person* returning to occupy these tranaformara among utility and non Regional Offices building* For a full analyale of meaaurea taken * part of the ctean-up of the Binghamton Are, tea "The Binghamton State Office Building Clean up. a Prograaa Report Update. 1983" (Ref. 7), and "Invaatigatlon of tha Contamination Remaining in tha Binghamton State OfAca Building Following Completion of Preliminary Clean up, October 20.1982" (Ref. 6). Theae coat*, for tha clean-up and removal of contaminated materiel* containing PCBa, PCDFa. and PCDDa found after theae Incident* can ba factored into the economic enalyela of the beneAt* of the continuad uae of PCB- utility owner*. . In the Auguat 26,1962 PCB Elactrlcal Uaa Rule. EPA aatimatad that tha utility industry owned approximately 59.000 inaervica PCB-Transformer*. EPA aatlmated that 22,489 of thaaa transformer* are located In non* substation location*, such aa In and round buildings and industrial facllltiaa. Tha 39.000 tranaformara repraaant about one-third of all PCBTranaformara i n service. EPA aatimatad that about 90,000 PCB-Tranaformera are non-utility owned tranaformara. EPA also estimated that there are over 10 million mineral oil transformer* In the electrical utility Industry and about Ava In October 1983. EPA conducted a telephone aurvay of Ita raglonal office* across tha United State* In an attempt to obtain additional Information on tha frequency of fln-ralatad event* involving transformers that contain PCB* (Ref, 10), From thla informal aurvay, EPA teamed that in tha period from February 1961 through September 1963, there were at least IS flra-ralatad incident* Involving tranaformara that contained PCB* (lis Include* tha Binghamton An. tha San Franciaoo lira, aod tha Chicago fira). EPA uses tha term "flra-ralatad Incident or avant" because In many Tran*former* Earlier analyae* of the million in all other application*- Thaaa caaea It ia not clear whether an actual benefit* of tha continuad uaa of thee* mineral oil transformers may contain Are occurred In tha vicinity of the tranaformara. completed in aupport of relatively tow level PCB* (lea* than 500 transformer. However, ihera appear* to tiie Auguat 25,1982 PCB Elactrlcal Uaa ppm PCBa) a* a result of contamination be full spectrum of flra-ralatad event* Rule, did not lake Into contldaratlon the from past servicing activities, that can occur in tha vicinity of a cotta of clean-up in the avant of a PCB- Traraformer Are, 2. New information on PCB- transformer. EPA believe* that minor Transformers. In lata September 1983, a arcing with no apparent volatilisation of In Unit V of tht* Notice. EPA ha* preaented preliminary estimates of the coat* of clean-up in combination with estimate* of the probability of *uch an occurrence, and preliminary ealimaia* of the coal* of varlou* control maaaure* designed to mitigate or eliminate the risk* poaed by PCB-Tranaformar Aree. major building owner in the Unitad State*, tha Equitable Life Assurance Society of the United State* (Equitable Life Assurance), approached EPA with Information on PCB-Transformars present in its building*. The survey conducted by Equitable Life Assurance indict tea that of the over 500 building* owned by this corporate building owner, PCB* or formation of oxidation products la at on* and of tha spectrum and a Binghamton-like event 1* at the other end of the spectrum. It is not deer whether condition* short of a Binghamton or San Francisco situation can also lead to the volatilization of PCB* and tha formation and/or distribution of toxic oxidation product* approximately 38 site* ere tervicad by of PCB*. EPA solicit* data on what other about 277 PCB-Tranaformera. Flftaan of fire-relalsd conditions, short of tha MONS 214115 federal Register / Vol, 49, No, 56 j Friday, March 23. 1984 / Propped Rule* 11077 condition* present during Dree like estimate!' 3-4 Are-related incidenta per Binghamton or Sen Frenciico, cen alto 1.000 PCB-Transformer* per year end 2 lead to the volatilization of PCBa and 3 Ars-reiated Incidents Involving PCB- the formation and distribution of PCDFa> Tranaformars par Are department par PCDDs, and other toxic oxidation year, product*. r If ona assumes that there are 140.000 According to the reault* of tht* PCB-Transforms)* In service (a* talephone turvay, thare ware two Ara- estimalad by EPA in tha August 25.10B2 elated Incident* in region I (both in PCB Electrical Use Rule), than. 3-4 Art- Boeton. Maeeschuaells). thraa incidents related Incidents par yaar per 1,000 in Region 11 (in New feraey, Albany, transformer* would yield an estimate of New York, and Binghamton. Naw York), between 420 and 500 Art-relatad two incident* In Region IV (in Incidents par year. If ona assumes that Cl*arwatar and Miami. Florida), one alinon-subatation PCB-Transformers incident In Region V (In Chicago, (H4.4M) art located In or around Illlnoi*), one incident in Region VI (in building*, than, 3-1 Are-relatad Incidents Corpus Chritti, Tax**), ona Incidant in par year par UOOO non-substation Region VII (In Kanaa* City, Kanaaa], two tranaformar* would yield an aatlmata of incidanta In region VIII (in Denvar. between 342 and 455 PCB-Transformer Colorado), and four Incidenta In Region Are-relatad Incidant* per year in, IX (in California) (Raf. 10). buildings. Thu*, in a two-year period, without IT ona assumes that there la an any formal EPA machanlam that average of 10 major Are department required tha reporting of Area Involving Jurisdiction* per State, end a total of el tranaformar* containing PCBa. Aflaen least 510 jurisdictions in tha Uni tad incidant* war* reported to EPA regional -States, than, a 2 or 3 Are-related ofTicaa, Detailed Information on all of tranaformar Incidanta par Are thaia incidant* la not readily available.. . department ytalda an estimate of In many caaat, monitoring for tha 'between 1.020 and 1,530 Ara-reletsd preaanca and distribution of PCBa and PCB-Treneformar Incident* par yaar. pyrolyai* products does not seem to In addition, from data oollected In nave bean undertaken. Finland on PCB-Transformer Are*, tha Tha cau*** of tha** IS Ore-relatad Director General of tha Finnish Institute incidant* are also not always known. of Occupational Health (FIOH) Whan csuta* ware msntionsd by survey estimated that that* may ba aa many as retpondsnta. they included: (1) 1,120 such Incidanta In tht United State* Shortage* In bus-bar*, (2) switchgear each yaar. This Is based on tha malfunction*. (3) electrical shorts or assumption that tha frequency of Ara ruing of the transformer, and (4) high rat* lad events In th* United States voltage cabl* burning. One of tha more would bs tha earn* aa that In Finland. disturbing incidant* described by ona of EPA haa contacted the Director General the rsglon* wet a cas* in which refuse of FIOH to obtain additional data on th* present in th* vicinity of a transformer baaia of hia aattmataa. caught Are aa a result of sparks from an Information compiled from th* arcing transformer. Tha Are itself began National Fire Incidant Reporting System In the refuse beneath tha tranaformar. (NFIRS). a computerised data bass and, II eventually caused tha rupture of managed by the National Fire tha Iraneformar eating. ,, ' Administration, indicates that than EPA aolicite additional data from were 1.405 transformer Ares In calendar knowledgeable partita on tht yaar 1052. Thass data are not, howavar, clrcumetancae surrounding tha Ara* paciflc to PCB-Transformer* EPA is in related Incident* described above, EPA tha process of obtaining accaas to this e!*o solicit* Information on the data base for purposes of determining circumstance! (unrounding other tha percentage of theea Ares that incident! that EPA may not ba aware of, Involved PCB-Transformer*, especially information on tha caueae of the firee and tha Information and distribution of contaminants. D. /long* of Eetimotet of the frequency of PCB Trantformar Firaa C Other Estimate! ofFir* Frequency EPA hee developed a range or preliminary cellmates on ths frequency Informs] discussions bstwesn EPA of Are-raleled incidents Involving PCB- represent stives and representatives of Trsnsformars. Ths lowsst estimate Is ths General Service* Administration eight par year basad on report* lo EPA. (GSA). regional Are department*, and Tha hlgheet preliminary aatlmata. 1.530 the Netlonel Fire Admlnlelrtllon have Are-related Incident* per year, it arrived yielded some preliminary eatlmalee of at by assuming thst Are department* tha frequency of flra ralatad Incidanta throughout ths United Stales responds Involving PCB-Tranaformera. EPA has n average of 3 PCB-Transformer Are- obtained tha following Informal related incident* each, per year. Other preliminary eatlmalee include 600 incidenta per yesM*s*um*e 4 flrareleled Incidents par yaar par 1.000 PCBTranaformars). 1.120 Incidents per year (assumes probability of a Are In the United Slate* la equal to tha probability of Are In Finland), and 1.406 incident! per year (assume* ell transformer Ares reported to tha NFIRS are PCBTranaformar Ares). EPA aolidta data on tha validity of the aattmataa provided above, aa wall ae data to aupport other estimate* of tha frequency w Am-raiatad incidents Involving electrical transformers that contain 1 i of PCB Transformer* sod 1 i Availability of Substitute* fPCBa PCBa war* orginally used as dielectric Auid In altetrical transformers primarily because of their flra-raaletenl properties. Traditionally, PCB-Tranaforman war* placed tn locations where concerns for Art safety were paramount. Evan today, PCB-Tranifotmara that art In atoraga for ra-uaa art placed In or around building* whan Art eafaty la a concern. Other dielectric Auid*. such aa mineral olL have superior electrical properties to PCB*. but their Are realatant properties re not as good as PCBa. Thus, any consideration of phaelng out PCB-Transformera must ba accompanied by an analysis of tha Araresistant properties and potential toxicity of combustion product* of substitute Auid* In addition. EPA must vslueta tha adequacy of tha electrical properties of thasa substitutes. 0. Substitute Transformer! In Its August 1982 PCB Electrical Us* Rula, EPA condudad that adequate substitutes axis! for PCB In Indoor transformer locations. Tha following units summarize available information on tha Are safety and electrical alTtcacy of substitute transformers, end discusses available Information on the toxicity of ubetitut* dielectric fluids in combustion situations. There are tlx general types of substitutes for PCBs In transformers: Silicons*, hlgh-tsmpsrstura hydrocarbons (MTH). chlorineled hydrocarbons. non-PCB ttksrels. fluorocarbons, and mineral oil. The following eummarizes dale tvellable to EPA on tha fire safety, toxicity in the even! of e Are. and electric*I efficacy or each typa of substitute fluid. Thera are aavsral phyalcal/chamlcal properties ofauballlute dlslectrlc fluid* that art uaad a gulds In determining Are safely. Thee* properties are tha HONS 214116 11078 Federal Register / Vol. 49, No, 58 / Friday, March 23. 1984 / Proposed Rule* euloignillon temperature. Iht flash point, nd In* fir* point. Th* minimum temperature *i which a ful burs I* Into flames whan lh* stimulus I* thermal I* referred lo as th* autoignition lemptralure. Th* temperature at which first llamas appear from a free radical eource auch sa an arc, spark, or Oam* la raferred lo aa th* flash point. Th* Rr* point Is a slightly higher temperature at which flames are auatalnad Currently, Ihs National Electrical Cod* requires a minimum Or* point of SOO'C for unvaultad electrical transformers, Th* property of having a fir* point higher then 300*C allows classification of fluids as "less flammable transformer fluids" by Factory Mutual Research Corporation (FMRC) During the past few years. FMRC. with th* assistance of industry and government, has developed a philosophy for hazard reduction, performed experimental end theoretical research, and has issued a last sequeno* for recognition of less flammable transformer fluids. ' Th* first requirement of the FMRC Is thet Iht fluid have * fire point of at feast 300*C. This temperature Is sufficiently high to afford resistance lo small Ignition aourcaa, such as matches, but 1* still low enough lo be met by eeveral classes of commercial fluids, including silicons oil, The next requirement iathattha transformer bs located within a dam that is at least four times tha area of the transformer lank and is deep enough to contetn all (he fluid In the event of a spill Should th* fluid become Ignited, end ii Is assumed thet It will be, and become fully Involved in flame*, thl* Insures that the Asms* will not epread along the floor. The final requirement le a maximum allowable rat* of convective beat release. In a nonflammable building with nonflammable contents, lh* rlak of extensive fire loss ia mainly to tha structure itself. If tha calling over iha lira Is overheated, collapse of tha roof could occur Heat release rets* have been messuiad by FMRC for several fluids. l. Silicone*. Silicones refer to a family of relatively Inert liquid orgenotiloxene polymer* used ei electric*] Insulation. Although ellleone-fllled transformers 1 have been used slnca 1072, In th* last (Iva years, their us* has Increased significantly. They are superior to miner*! oil end non-PCB askarels In thermal stability and, unlike mineral oil, will not degrade to form sludga. They also hava firs points above JOQ'C. Combustion of silicons*, whether by arc-induced explosion or spray mist ignition, produces fluocculant silicon* dioxide particles ind globules of silica- gall. Breakdown products during arcing In the absence of oxygen are eilicoo* dioxide, hydrogen, and hydrocarbon*. Another disadvantage of HTHs is the Increased vUooelty compared with the! Water, carbon dioxide, end carbon of mineral oils. This higher viscosity st monoxide are eleo produced In the norms! operating loads esusts slightly presence of oxygen. Silicone fluid* are self-extinguishing when burned in a higher operating temperatures end could possibly shorten lbs Ufa of Iha pool, since cruel la formed which transformer mothers th* flame*. - 3. Chlorinated hydrocarbon*. Silicon* transformer fluid* also have some disadvantages, They absorb Chlorinated hydrocarbons refer to s group of chlorinated aliphatic moisture from the air vary rapidly and hydrocarbons. Th* primary chlorinated extreme care must be taken to transfer " hydrocarbon being considered for um it the fluid without contact with the a electrical Insulating fluid it atmosphere In order to **< proper perchlorosthylane. Ins primary electrical properties. Product literature advantage ofperchloroethylene It its from on* silicon* fluid manufacturer nonflammability. . roughly stlmatss that at 100'C, sUloone Breakdown producla from complete fluids will circulate S or 6 time* more combustion during arcing Include slowly than askaral or mineral oil. This hydrogen, chloride, carbon, carbon slower rat* of circulation may hava monoxide, carbon dioxide, and water. Implications on tha ability of th* fluid to Deta ere not available on th* products dissipat* beat of Incomplete combustion of chlorinated 2. High-temperature hydrocarbon* aliphatic hydrocarbons. (HTH). EPA utaa th* term HTH lo refer 4. Non-PCB atkanit. Non-PCB to mtnerel oil* with a fir* point higher Aikarel ia a generic term for a group of than S0O' C. This category of fluids synthetic, fire-f*(latent, chlorinated Includes high temperature asters that are aromatic hydrocarbon* primarily used In railroad transformsre. - (chlorobenzenes) used aa electrical Tha primary advantage* of HTH* are Insulating fluid. The primary advantage* high Are point low toxicity, of the aon-PCB etkaral* are their blodagradability, and the long usere nonflammeblllty end lower costs history compered with other transformer compared to HTH* and silicone*. Thee* oil*. The higher fire point of HTH fluids fluid* an treated tha tame at PCB- mitigates somewhat tha fire hazard askarels In tha National Elactrical Cods. normally associated with tha uaa of At mentioned in Unit 1LB.1 of thl* mineral oil tot indoor location*. Notice, however, experiments have HTH* are refined from paraffinic-typa shown tha formation of PCDFs and base oil. Breakdown product* from PCDDt from th* Incomplete pyrolysis of complete combustion during arcing In mixture* of chlorobenzenes tot air. tha absence of oxygan an hydrogen, Amount* of PCDFs ranged high aa carbon, and hydrocarbons. Products produced In tha presence of oxygen tenths of a percent for mixtures of trichlorobeneenee. Include water, carbon dloxida, and 5. Fluorocarbon*. Fluorocarbon* hydrocarbon*. Data are not available on (specifically Freon 113} are being lasted the products of incomplete combustion for use at a transformer fluid. EPA ia of HTH*. soliciting Information on tha fire safety, Ester HTH* are used primarily In railroad transformers or where elsetrie* I efficacy, and toxicity of freon fluids in fir* situations. transformer* muel (tart up under vary 0. Mineral oil. Mineral oil it a refined cold conditions Because there cost ts mineral insulating oil lo which additive* higher than other HTH* end they offer such at oxidation-inhibitor hava bean no real advantages in Indoor location*, added. It It used in the vast majority of it Is likely thet ihe perefUnlc HTHs will outdoor transformers. ba (he metsrials of choice for lhasa uses. If fire safety war* not a consideration, The viscosity of si least soma HTHs mineral oil-filled transformers would decrease* more rapidly than other transformer fluids under Iha action of increased temperature* associated with overloading. Inis properly allow* probably be uetd in all applications. Mineral oils costa last than PCBt, have better heal transfer properties, are considerably lighter In weight, and form greater cooling during overload conditions. Tha primary disadvantage associated with tha usa of HTHs Is that thay hava a noncorroalve products under conditions of electrical arcing. Tha ma|or disadvantage of mineral oil it its flammability dut to a low flash higher heat release rate than other. substitute*. This mean that tha HTHs point. If arcing occurs, the complete combustion breakdown products are wlltburn at over twice the temperature of silicone fluids, thus, potentially causing more damage In an indoor fir*. hydrogen, methana, other hydrocarbons, ctrbon monoxide, and water. Data are not available on the products of HONS 21411? Federal Ragiatof / Vol. 48, Ho. gg / Friday, Match <3. UM / Prnptww1 Ration 11071 Incomplei* combuatlon of miner*] oil. Exparlaaca with ratrofllUag PCB- Thi National Fir* Cod* mquim. with Tranaforman aloe* ft* of lha tom* exception*. that ofl-feoadattri Aufuat S. WZ FO BaotrienJ Uaa Rule traniformara to*Irfri Moan ho yAnead ladleetee (hatrakoflUiag *rift klkona* In vault*. Bacauaa trf On coot of tnaulhng tranfonaan In vuafc*. Oik it * disadvantage of adoaial oA tranaformara. A* ooncfcadvd In VA'i Angnat A 1M2 PCB ELactrical Ut* Rota. EPA ballavta that edoqaet* nhcmut** aadd for PCBt la Indoor tranafonnar loco Kona from th* panpacttv* rf On aafaty and electrical efficacy. EPA k aoHdtlm information, however. on th* tuxidty of aubatltut* awiafomwr fluid* In combuation alt** Ilona. Specifically, KPA ft aollcltln|data on (ha products of inoomplala combustion of aubitituta dielectric fluid*. C JUtroftiling PCB Tran*farmn to radaaalfy tnaaforaara ea noo-PCS k not practical at thk time, k all anly ana tranaformer ratroflflad with kllnnni fluid baa bate able la mash mad maintain Wvala seder *0 ppm. ~ Companlaa nnnUrtori during tha peat few moathe bar* an spaed that ratrofUltad to___- - ' thao 10 ppat PCBa k Howtvac meat to maintak kv ba oaotwffaoftk la many I. HTHi. Than an atx HTH aoldbaflua companies thai maybe--ad a wtaafotmar dkkflkk Wrida. Thee* ara alaa two prodnom aaU by two edma companlaa that aahan mtxad arift other 1. introduction. Two |n*T*l typa* of prodacW may ha mod ea HTH ' ubatltutaa for PCB* la troraforwwra tranafonnar flidda. Thiaa of tha alx land out (ha boat rawoRll fluid*aaapanlfMkofcaaedriband (baa candidate*. Thaa fluid* art aflkonao , , ara attan. Aa Mattonad aorhar, the and high tamparahot bydrocaibona - . (HTH), Tha principal question* to ha ` la railroad tranafoimora. oonaidarad art tha eoat of ratio(HI vartut tha value of (ha ranutnlrq Ufa of tha transformer and tha ouiiffication of tha fluid `lata flammable" for tnauranoa purpose*. Othar fluid*, toch a chlorinated hydrocarbon*, fluorocarbon, and minor*] oil may ba utod In naw tranaformara bait art inappropriate for ratrofllilng bacauaa tha daelan of tha PCB-Tloitafonnat* doaa not fit tha propartlaa of tha fluid*. X. Siliconot. Thara ara ala effloona fluid* aold by alx dlffarant companlaa for uaa dialactric fluid. Poor of th* tlx flufda have baan approvad by Factory Mutual "lt* flammabla" fluid*. Slllconaa have a higher vlaeoatiy than Tha after three ftrida ara i vtaooua ftaa dm tlhoattaa at loarar tamparatria*.but thla man rapidly at higher tamperaturaa. According to aa HTH manufactnrar; thla properly allow* lha tranaformara to bo ratroSUad with, HTH without any derating. At tower normal load temperature*, however, dw tranaformara do na hotter. Thaaa flulda ara oamptately compatible with tha material* diet malt* up PC8Trxnaformar*. and thay are soluble la PCS*. Thao of duaa flulda ara npptovad by Factory Mutual aa "taaa CacrunabU tranafomar fluid*," and the Bra point of tha third k ever 100* C. PCBa and art tharafon not quit* Aa with sUlcontt, It doaa not worn comparable a coolant For thk practical to nt/oflll to maintain PCI reason. tl la poaalbla that tranaformara concamration* undtr 50ppm. However. ralrofillad with atllcono would havu to II la poaalbla and coit-affactlv* la maay ba derated. According to ont aflleoM eaaaa to maintain oonoantrationa under fluid manufacturer. If tbc tranafonaar wart fully leaded, a darallna not BOO ppm. Tha coat variable* are about tha aama foraltlcona flulda, axoapt, exceeding ftva paream could ha nacaaaary. l! ha* baan mantlontd In tha lltaraturt that a Utkin* probitm could bo created bacauaa alllcon* fluid* era not compallbl* with afllcona rubber itakala and tha eoaffictant of aupanalon of itlcon* flulda I* *0 parcaot (raatar than that of PCB*. In actual practice, however, tha altlcona taakat* art raplacad durtn* rairofilllng, Further, avan thou*h tha coafflclanl of aupanalon It malar than that for PCBa, (he *r*ator HTH flulda raqulra annual taatinf and poaalbla fUlarint to ranwva atolaturo or parilculatoa. _ Bacauaa tha paraffinic HTH* havu ' high convactlva and radiant beat ralaaaa rata a. tha owner'* inauranca company may r*command mora alrinfant Inatallatton requirement*. EPA la aollcllln* comment* on tha Information provided above parialnln* to utllltla*' axparianc* with ratrofllling, and the ability practically toraduca PCB toTublllly of tha flllar ** [nllrogan] la concanlr* Ilona to below SO ppm by alllcon* atlmlnala* that axpoctad retrofitting. increata In praiaura. Atnffwn afdAamatitv Sayobiny Opboni for PCB-Tmtfamon 1. Chamupemc*. Thar* an two catogark* of daaa-up aorta that EPA comldarad la evaluating th* coat- ___ " afuarioaaapttont fcrPCB- " (.Tnaftrat___ _ _ _ of apffla from tranafonnar*. In Ik August SS. mu PCB ftectrkal U*a Ma. BPA aawwiod that (kl parrum of PCB Trunafarmart felled yau. and that 477 parcant of the** talluraa maultad In p4U. EPA aaauiuaJ thnl an ovmtga ofH540 wna apant por year par apUL Tha aacoad oakgory efdaan-np coak k tha coat* aaaoclttad with thaetaan-up ef cakatioplik faUuaaa. For purpoaaa of the loBowlnt anaVata. EPA aaanmaa a cat*atropbJc failure rata of OXri pamanl par year, and that daan-up ooala art gx ndlllon par Incident Thaaa oaata war* not factored Into lha Agancy'a aeonoak nalyala complatod lor tha Aunat U. I9tt PCB Bodrical Uaa Rule. EPA praamt* ranya'of caHmaiaa of die prcbabllliy of eataabophlc faHerat In Unit m.C Them probanflltiaa mnfa from 0.0000 parcant par yaar (about Incident* par year) through 144 parouat par yaar (about 14*0 Inddanta par year]. (Additional tabUa (that inoorporat* tower probebflltla* of eakitrophk flraa) ra proaantad In lha preliminary coalaffactivtnaaa analyaii complalad far thk ANPR (Rat 11}.) BPA'a aatimata of daan-up oaata octalad with cteatrophic avanla wu derived from aatlmataa provided from lha Blnghamtoa and San Frnndaeo Incident*. Furthar, la th* analyak ptaaaalad below, EPA auumaa that little coal la normally aaaoclatad with daan-up foliowin* non-PCB tranaformer flraa In cat** wbarc litlla atructural damaga occur* to tha butidlng involved In th* tin EPA 1* aollctttnj data on tha coat* aaaoclttad with daan-up following flraa In tranaformara that do not contain PCBa. X Companion ofchan-up coak vinui pnau-out ooitl. Th* following tabla uaa* a population of 114.400 anils (EPA'a alimala of tha oumbar of newubatatton PCB-Tranaformara) and an aatimata of equipment Ufa of M yaar*. and compare* pnata-cui coat* to clean up cotta avoided If phaaa-Mt waa Implamaotad over n l-ytar parted, over a 10-yatr period, and overt 10-yaar period. EPA did not eonaidar Immsdlala phaaa-oul bacauaa tavaral parton* Indicated that manufacturing capacity waa tnauffidant to allow for thla option. HONS 214118 11080 Federal Register / Vo). 49, No. 88 / Friday. March 23, 19B4 f Proposed Rule* For full description of th* assumptions used In th* following analysis, and for a more datallad analysis of phaaa-out cotta vartua clatn-up coals avoldad **t "Preliminary Study and CoatEffaetlvanaaa Analyaaa of Altamatlva Rafulatlona for indoor FCB Transformers. Fabruary 1994" (Raf. n). Taou i--pmuuinabt ooaT-emcnvtMH oa AiTtoNATtva PCS AcowunoN* son PHtU-OUT OP UTtUTY-OwXtO AaiMML TiuMaaonutnt { !< !> ! Om J2L fwSrSnSmAt ioto ttmm Mm ii mm m ..... MO-I * nrt i MM Wl 4fit i jm* mm mmmm 3 Ruroftiling. EFA haa complatad a prallmlnary analyala of tha coata of ratrofllllni PCB-Tranaformar* to raduoa PCB concantratlona to balow 500 ppm. EFA aallmataa that ratroflU coat* will ring* from 110.730 to 832.034 par '' transformer, depending upon tha aiaa of. tha tranaformar. Thaaa estimate* do Includa tha coata of dtapoaal of PCB fluid, but do not tnduda any conaldaratlon of a loaa of aftlctaney or dtratlnt aa a raault of tha ratroflll. An aatlmata of tha total coata of requiring th* ratrofllllni of all PCB* Tranafomar* {114,409 in aarvlco non* aubalallon transform*!*) to balow 500 ppm la about glJS billion. Thta can ba comparad to an aatlmata of claan-up coata avotdad of about |1.7 billion. This aatlmala of claan-up coata avoldad aaaumaa that ratrofmad tranafonnat* that contain laaa than 300 pm PCBa that ara fnvolvad In flra-ralalad lncidanta would not raautt In tha formation of PCDFa or PCDD* In auffldant quantllia* to trigger major claan-up effort*. EFA do** not know whathar this la a valid naumption EPA la soliciting data on lha polanllal for tha former of PCDFa and PCDD* In PCB-ContamlMlad tranaformar*. EPA alao complatad a prallmlnary annlyal* of th* coat* of ratrofilUnf of PCB-Tranaformar* lo raduc* tha concentration of PCB* to parcanl. An aatimala of tha total coata of requiring retroflllfni of all non-aubatatlon PCBTranaformtr* to 6 percent PCBa la about ti 3 billion. EPA la alao aollcillna data on the formation of PCDFa and PCDD* In thla category of tranaformar*. For additional Information on th* coata of requiring retroflllng, aea "Preliminary Study and Coat-Effecllveneaa Analyaaa of Alternative Regulation* for Indoor PCB Tranaformar*. Fabruary 1994" (Raf. HI- 4. Fm haiard Intpoelioni Following rang* from 92400 lo 15.000 par tha tranefotmar fir* In San Frendsco. tranaformar location (Rtf. 11). the owner of the transformer Involved In In addition to doting off tranaformar tha fit* (Pacific Gaa and Electric location* through tha uaa of aalanto, Company (PC*E)) Inatltvtad a fir* EPA ballavoa that th* uaa of amok* hazard lalatad Inapaction program for datadora and other aanaor* In PCB-Tranaformar*. This program tranaformar location* to craata an early conaiatad of Impacting all network PCS- warning ayatam may ba beneficial In Traniformer* on a regular and fraquant mitigating th* rtrlu from Hr** Involving bull, using mw tachniqoea auch aa tranaformar*. Further, the mm of a heat Infrared aanaor* lo dataot patanttal * tanaltlva or amoka-aanaltlva baffling dafacti ("hot apots") In tha tranafonnart ayatam In ventilation duct* exiting tha and alactrteal tqulpment In th* era* of tranaformar lecatioe eould radoc* th* th* tranaformar*. In addltloo. for spread of contaminant* vta thla rout*. Increased Hr* protection. PCAE lnitallad For sddlttonal Information on th* aaoondary disconnect ewttcbat at PCB- economic* of Implementing th*N type* Tranaformar location*. of liak nducUon maaaurva. aa* EPA balltvat that completing tranaformar fir* hazard Inspections of PCB-Tranaformar locatfoM may b* th* Initial alas In a program lo raduoa tha likelihood of rutur* Area Involving thla equipment and lo mitigate risk* aaaodatad with thaaa Hr** should they occur. Other factor* oonaidarad In a tranaformar fir* hazard Inspection might tnduda a consideration ot Th* ag* or th* tranaformar and tha igalnltiianc* history- tha location of tha tranaformar. tha location of ventilation equipment or ductwork In th* vicinity of tha tranifoRMr. and the presence of combustible* In a tranaformar vault or near a tranaformar location. EPA la adidtlng data on tha ` affactlvanaa* and cotta of ualna Infrared aanaor* to Identify potentially Faulty equipment, EPA I* alao tollciting data on th* affactlvanaM and coata of other almilar lachnotoglaa, and information on th* affactlvanaaa and coata of kwlaQlng and using secondary dlaconnaot witch** axtarhsr to tranaformar location*. EPA la aolidting commanto on Its Uat of factor* to b* oonaidarad In Hr* hazard Inapaction*, and comment* on th* ability lo reduce th* polanllal for Hr** by completing Hr* hazard ImpedIona and Instituting appropriate corrective maaaurai. EPA la aolidting Information on other factor* that ahould ba Indudad In a PCB-Tranaformar Hr* hazard Inspection, and information on th* costa of conducting auch Inapacttona. "Preliminary Study and CottIffadivanata Analyaaa of Alternative Regulation* for Indoor PCS Tranaformar*. Fabruary 1M4" (Raf HIEPA la aolidting information on available amok* and Are control tachnoioglaa. thair application to PCBTranaformar Hr* iltu*lions, thair ability to raduoa th* rtaka aaaodatad with thasa Hr**, and th* oeala aaaodatad with lotlailiog thaaa ayatam*. 9. Reporting ofPCS-Trantfomor flnt to EPA. EPA la solidting oommant* on th* benefit* of Instituting a PCB- Tranaformar Hr* reporting system within lha EPA- EPA baHava* that spodflcally requiring th* reporting of thaaa Incident* would Incraaaa th* general level of knowledge about how thaaa Incident! oocur. th* drcumatanca* surrounding these Inddanta. and th* nature and level of rtaka posed by th*M Inddanta. EPA t* aolidting comment* on th* ooau aaaodatad with requiring such reporting, and th* boMfita lo public baeltb from such a system. EPA solicits commonts on th* machanlca of such a ayatam. Including comments on conaldaratlon* auch (1) Who would ba reapontlbi* for reporting lbs nr*. (X) whan th* report muat b* Wad. and (t) what lyp** of Information must b* reported. 7. Rotitlrollon ofPCB.Ttvniformtrt with fin dtpartmontt. PC9E. In talaphon* conversation with EPA. Indicated that It routinely Inform* fir* departmanl* of tha location of PCBTranaformara In lha utility ayatam. 9 Fin/tmoko control Uohnolpgit*. Repreaentallvaa of tha fntarnationol PC5E. In addition lo completing Hr* Flraflghtara Aaaodatlon and hazard Inspection*, haa committed to repraaantatlvaa of flra department* have easting off all opening* through It* Informally Indicated to EPA thair dealt* network vault*. Presumably, thla la to aea thla pracllca Inslltutad being dona lo reduce tha spread of nationwide. EPA ballavaa that tha rlak* amok* lo araoo adiacent to tha poaad to flraman and byalandara during tramformar location tn tha event of a PCB-Tranaformar firs* could ba fir* EPA haa obtained a prallmlnary significantly raducad If tha Initial rang* of aattmaleo of lha cotta raaponaa team la aware that th* fir* associated with aeallng off tranaformar Involves a PCB-Tranaformar. and that location* lo raduc* lha apiaad of that* art certain rlak* associated with contaminated amok*. That* animate* extinguishing such a Hr*. HONS 214119 ir / Vol. <8, Ho. H f Friday. March tb, IW f Prapoaad fluiaa 1M81 EPA li tolldtlng comraanto an toe effective!)*** of aupplytng thit Information to Dr* oapartmana boa ft* narapecUv* of reducing th* dak* paaad from the** lacldaata I* fframan and byatandwi EPA to alao anllnUIng data on th* mil if pcbvkUo* foaua data a Dr* daparia*at fonadtcttona. B. UUliti** Thai Hava Mode Dacieloa Vatantartly to Photo Out PCBrnniforme/o 1. PCM PG*E hit deddod to rvptac* ft* an PCB-Tnntfonaor* ta tba 6*a Franctaco or** on * priority b**l* by December Of 3SB7. According I* PCAB. 40 PCB-Tranafonnarv la vault location* r* to b* nplaoad by Juna ml IBM. and 46 PCB-Tranaformara tat U klgh-ria* ' building* *r* to b* rvpUcvd by fun* 34, 10*4. Th* remaining PCB-Traaaformen r* to be rwnovad by tb* December 10*7 data. In th* biterir*. PC*I la oompUtn* PCB-Tranaformar (Ira bawd IniMcUona. aaellni opening* la vault*. . ana pl*cfn| tacondaiy dlacoonact awilchaa at PCD-Tranaformar location*. A Florida Powar andlight Florida ' Fowar and light Company (FPCCj baa alao commltlad to raplaetng It* 4M PCB- Tranafoman. fat Saptambor IttL FPLC nnounoad Ita plan* to opand man than SIS mlllloo la tooth Florida over a fiva- Eaar partod to rapiac* thla aqoipmaot Mali* on lha priority aytltm far tb* removal of that* trtnafonnor* wta not available to EPA. but. EPA la InUraatad lo obtalnln* thla typ* of information. I. Barton Bditon. Aooordtit| to a lattar datad Aufuat *, 1SOI from Boatoo EdUon Company (BBC) to a property management firm. EEC (a I* lb* ptoeata of davaloplni program* for fit* ordarfy llmlnatlon of PCS aqelpmaal from Stair ayat*m. DEC Indfcato* that they baft alrtady bagtm lb* txamlneUou of (ranaformar vault* la bolldlnga for purpoaa* of datannlnbig what work w9 b* required and who* H mop bo achaduled. EPA hoa a* briber dttafla oo BEC'a daclalon or on Ita priority ayatom for the removal of thla laripmaaL EPA la aollel* In* additional Information. EPA la (olldtlng Information from other Militia* or building ownar* that hava mada tha dadilon to ramova PCS* Tranaformara from thalr praaaot location*. and data on tha baala for making tba daclaiona to phaa* out thla aqutgmanL [ VI. Summary of Data Naada for Propoaed Rule A. Pitk* Pend by FSret 1 Number, location, andownerthip of PCD- Trontformert EPA la aoUcItlng Information on lha typaa of bulldlnga lo mhhfrPCS-TtmM amkwafKSI each building, tha not of tba I tha aga of tha tranaformara. ( of thoPCE-Traoriiin ni wring h* li illh^i aialtki i aiaMfri aflba Oauafur--ra. EPA la afro "**"*"-* Inform* don an toe location af PCD Trarafarnwrv other than thoa* praamI te or dfraedy aandcfr^ britdMp. 1. Pepukitcee enpoeed. type* of chemtaak, madlank efeapatma. EPA la aofldtlng tobwaliewoapoytobitoa* potantlally axnoted to PCBa and PCSoxidotto* proooett lo lb* onto! of a fc*. and tba favaft #f chtaitoal* t* avbtah lb* population* an palanilaity I. Moult* of ttpmam * I oxidation product*. EPA la aallrtdng Information on tb* potanOal aaotaa of axpoaur* la PCS* and lhafr onfdaSon product* to to* avast *f a Sao iaalvtag_ thla aquipaiacx. EPA it aoUdttng infoimalion on tha tola of vanllLHon equipment and ductwork to tba dlapanloo of ICS* airi ovldotloo product* from PCS-Tranafomam Involved In fin*. andSan Praac/ooo data. XPA to aoUdUng oommant* on 111 aoahrai* of tba Binghamton and San Fkandan* fim and on th* reprvaantatjvcoaaa of tboa* flra* from (bo parapactivr of evaluating jhanotur* of tb* flak* poaad when a PCS-Ttantfoimar la'tnvolvad In a Bra- aalatad Inctdmt . S. Information an tha ritkspondby tha fin th Chicago. EPA I* aondHqg addition*! data oat tha cau*** of and dreamrtanea* aowoondtog to* September 1M Chicago fin, arwaB aa Information on tba iMta poaad from thla 4. Information on other firo-nlattd incident* irrroMng PCS-Trantfonoen. EPA 1* aotldttng data on other PCSTranafonnar flra-ralatad Incktont* to addition to dot* on Binghamton. Sea Frandaco. and Chicago. EPA la aoflctting data on Bio tlmo. data, and location af th* ineidnb th* can** of tha Incident Bta extant and avanua of amok* tmvafr lb* location of ventilation equipment relative to lb* location of tha fir* th* typ* of equipment Involved In tba bidden!: tha eg* af lha equipment: th* typ* of building In which lha Incident occurred: th* number of people praaant In thq building at th* time of tho Incident: tba time elapaad between to* beginning of tha flra and tha raapona* of tha fir* department: lha time required to da-anargli* th* tranaformar, th* afTactlveneat of th* circuit breaker oa a protection davtc* In the Incident tb* potential for lha formation of oxidation product* auch a a PCDF and PCDDt lavala of PCBa. PCDF*, PCDO*. and otoer axrtalkm and pyrofyata product* owaaurad In tha butMtng fetkrwing th* fira: to* aatan of any dean-ap undertaken Mowtng the incident; and, to* oaatv of riaan-op foOtrwtng toa Inddant. T Photon that may Increate/deereaee tha rieke pored by KB-Trantformere in the event ef a fire-tehted incident. EPA I* aoticKBif Information on factor*, auch a* lha iallur* of protactian device*, th* boallon of vmrilktion equipment, tha typ* of buUdtog to which a fir* occun. ate. that may tocraaaa th* rlak* poaad to human* and lb* environment bom flra* towitotog PCS-Tramafbniiara. In addition, EPA 1* aoHciUng mtormatton on lactam toot ouy dam*a* to*** riaka. Bxpoteree and riekareauHing from contaminated water atfirm. EPA I* aabetttog oommant* an axpoauro* and rlak* that may (vault from water oantamlnatad at Era*. Contmnlnalad water nay rvmdl from tot appMonlton of water daring flrafi^tttag, lb* rupturing of pipe* andm high temper*tint, mm poiiibiy ntbar tonne* tncludijiq wataa from ctoan-up oparttiaaa foDenrtng tba flra. Contaminated water may enter a*w*r ayatama fboto aardiary and atom aawae ayaltma) and way wn off directly to aurfact water. Contamination of aowtra, traatmanl work*, atudga* and aurfae* water may raaulL EPA aolidta information and data on th* diatribadoo of PCBa and other taxi* ohamicalt through auch routaa. Including tb* aaod* of diatrfbuUon and anvtroamanlal fata; actual or antldpotad conooniralion lavala In water, aludga, traatmanl ayatama and biota: advene afiaota oat and continuing riak to 3----throuffa drinking water or Ingaatkw of oontaminalad food: rlak to atbar organ!aa* throat I* th* oparailon of aawaga traalmaoi aytianu: and lb* aoata ofdaaa-up. B. Frequency ofFire-RelatedIncident* SPA la aollciUng oommant* from building owner*, fir* department*, uillltla*. and other partita on too accuracy of EPA't nationwide aallmatat of tha frequency of Ora-nlatad Inddant* Involving PCB-Tranaformara. EPA It alao inlaraalad In dale on tho frequency of that* flra* varaua lha aga of tba tranaformara involved C Formation ofReaction Product* 1. The reaction product* found following PCB-Ttmtformorfire* EPA it aollclllng information on too typo* and lavala of oxldatlon/pyrolytlaf Incomplel* comboatfon product* that ar* found following flra-ralatad Incident* Involving PCB-Tranaformara. HONS 214120 110M Federel Register / Vol, 49, No. M / Friday, March 23. IBM / Proposed Rules 2 Tht rtactiOJU ond m*ci\aiutmt of nocuono tnvolrod In thoformation of rooctianproduct*. EPA1* soliciting Information on Ihs reactions and mechanisms of rooctlon Involved In tho formation of oxldatlon/pyrolysli/ Incomplete combustion products from PCBTrsnsformsr Am. 1. Th*polontial for th* formation of rooetion productt followingftnt involving PCB-Contaminotod Trontformon EPA to soliciting data on tha potential for tho formation of toxic rstctlon products from first Involving PCB-Conlsminstsd Transformers. D, Coots and Natur* of Coot* Asoodatod With Cloon-Up EPA la solicitinginfotmstionon tho cotta Incurred by owners of PCBTransfortnan Involved In Ara-ralatad Incidents. These costs Include the eosts of analysis. Ihs costs of dtsn-up and rsmoval of oontamlneled materials. Ihs coals of lawsuits filad by damaged partlas. and the coat* of teplarii^ the dsmagad vault and/or transfomarfs) following the Incident. EPA Is also soliciting data on the else of the area, cleaned, the levels remaining after dasn-up, and other explanatory Information on how clean-up money was spent. and why cleeo-up required the amount of money used. Cooto and Bonofito ofRogulotorjr Option* 1. Bonofito ofPCBt. EPA 1* soUdtlng specific information concerning whether transformer Ore Incidents hove been reduced over tha put 40 years due to PCB ussgs, whether this usage bas made s significant Impact on reduonglbe dollar cost* from building fires, and whether such usage ha* mulled la any appreciable saving of human Ufa. 2. Subotituto trontformon. EPA la aollchlng Information on the toxidty of substitute dielectric fluids In the exeat of o fire, ) BatrofUHng. EPA la aofidUng Information on the Are safety, ilecfcrtosl efficacy end toxidty (In Ihe event of a firs-ralcied Incident) of RCBTrmaformare that have bean retrofitted with non.PCB fluid. EPA Is alee soil citing comments on Iba PEDCa Environmanlal Inc. study of aubatiluto irontformart end dielectric fluids. 4 tdontifying high rioh trontformon. EPA le soliciting Information on who! comMiutee o high risk PCB-Tranaformar from tho peraptcllva of haunts posed In Ihe svenl of o fire-related Incident, and methods for Identifying such a transformer, EPA la soliciting Information On the costs associated with Inspecting ell PCB-Trsnsformer locations to determine which PCS- Traneformera would poet higher risk* In tha event of PCB-Trensformers that may be considered to be high risk transformers. k PCB-Tranofonoorphaoo-oot cooto. EPA la soliciting infonutioa on tha coats to transformer owners of requiring the phase-out of all PCB-Transformere over a-. 10-. or iB-y*ar periods. EPA 1* also soliciting comment* on the Potman Haves and Bartlett PreUmmafy Study and Cost-Effectiveness Analyse* of - AJtsmttiv* Psgiilsttnns for Indoor PCS- Transformers (Rel n) t. Phoot-out cooto ofhigh ritk PCB- Ttonoformoro, EPA It soliciting information on the easts to transformer owner* of requiring tho phsse-oot of PCB-Truneformen that IsQ within the high risk categorisation. 7. Fin hosarrfinunction program*. EPA Ic soUdting information on what factor* should be Included In * PCB- Tranaformer fin hasard inspeetloa and on tha affsedvanaataf Inspection* and ubeaquant oomettva msssurut In redudng Ihs probability of first and litigating the risk* posed when fine do occur- EPA I* also solidting Information on tha oosts aasodatad with completing thee* tnspectioa* end the ooets associated with Implementing oorractive measures following Inspection. . A reliability andoffocUvoetoo of oarty dotoOlon dorlcoo and omoko control iochnohoioo- EPA la aoUdting infonnatlon on tns offsetiveoeas of early detection device* la reducing the risks associated with PCB-Treneformer fin- related Incidents. EPA I* also solidttna informstion on tha availability of smoks contra) technoloflet to rtduoa the spread of tha contaminated smoke fawn fine Involving PCB Tranefortnen. EPA ts soliciting data on tha affsetiveness of thoao technologist la the avanl of an site(itcal power failure, which aflat accompanies PCB-Tranaformar file rsla led Inddents. . BEffoetlronoooandoootoofPCB- Trarttformtr pro reporting system. EPA la soliciting information on Ihe costs and benefits oflnatltutlng an EPA PCB- Trsniformsr fir* reporting system. 10, Rogiotratlon ofPCB-Tnmtformtn with fin doportmont furlodictlono or with EPA. EPA la soliciting dote on tho costs end benefits of reglslaring PCB- Trsnsformer firos w'.h local fire dsperlmsnt* or with regional offioae of tha EPA. n. Utilitiot that an phaolng out PCB- Trontformon. EPA Is solidting Infonnatlon from oil utiliilo* that have mad* the decision to phase out PCB- Tronstormers EPA Is interested In obtaining Information on the ration*)* for instituting those phsae-oul programs. VD. fiafesenose ID userA. OfH OD. v*f*ar. Inc, "Exposar* Assessment; Plraa Involving PCB-Trsesfomtsrs" (lanssfy i*M). - (t) WA. ORt HERO. Ttstpons* ts Comments On Haallh Bffoelt of PCB* sefcoiltad by tha Chemical Manaftctursn Assodsttoe and tha Rdlsoa Elsetrie tnsUtvta' (Aaguit IS t*u) (>) UBEPA Caidnofinic Assssiraonl Croup. Tha Caietoogmle Assasamant Croup t Risk Siaewm.ni an Itt.s- ' THrhlsrephsePXyi Aostlo Add *. T| (l4A.-Trtch*loropliaiiuxr) Propionic Acid (Sthrsi) SJJA-Tstrochtofodibsmo-r- UtoxJa (TCDOr [Bsplsmbar ItlNOl (i| Cesaren and DouQ, (tars) Toalcology tha salt tstoacs of hrisons.* MacMillan PubiUUngCo. Ina, yp tS-Sl IS) OtshL R. SSorlla. M, Puked*. H. (1*7*) "Camparativs Toxidty af Ntyeklorinatad RTphsavts end Dftmeshriua to Rais.' Tuxteelogy end Applied fberemsmlngy. 41,11-tt. (a) URRPA Oprg, HERO. Tbs Texldty af Root From PCB Ttaatformw Pin** (Ososmbs* m, lsea). (T) OCR. (tan) The Binghamton Rials Who* Mldins Qsoti w A Proyee* RspsrT Update.* Albany. NY.- New Ysrit Watp Offtoaef General Random flanasnURi) (*) Vsrssr, levmtigsUsn *f the Cealamlnartoa RsmatMag m tbs Btnghamtoa Risls Ofllas PuiMtog PsUorring Camplsdea *f Prehmtoary Clooo-sp" (Oetsbar 10. tsan (*j Tbs RqoiUbl* Ufa Aaswtao* Rodsty of the United Ruta*. Uttar Is David Deli, BPA Tqattsbla Ufa Asswanos Rarvsy' (Octobers. ISIS) (10) URRPA OPT*. BD, Tommary of Regional Data an PCR-Tranafarmor Ptreo" |OctobarlRl*Ol) (11) URRPA OPTB, RIO. MB, "PreUmtoaiy Study and Coat-ERbcUvMw Analyass at AltamaUv* RagulaUona for Indoor PCB Transtormats' (Pahtatry lias). (II) UREPA OPTR, RTD. PROCs ' Knvlrownanlal. ht, *tub*Utotos for PCBs ' tor Us* In Indoar llsttricsl Traasfaimsri* (Jannsfy ISM) (13) Mltrt Cwpsratton. "Eovtroniasntal Assaaseianl of PCBs to ihs Atmosphere,* Tsbtot Ml and Ml (April 1*71) (14) Ruaar. Hans Redolt `ToraaStloe af Polychlorinslsd Dlbrmiofurtn. (PCOPs) and Dlbsniop-Dioxin* (fCOD.) horn tha Pyrolysli of CMerobsnssn**' (117*) (15) Rusor. Han* RudoH, "Formation of Polychlorinatsd Dlbonsofnrans (PCOPs) from the Pyrolysis of PCBs' (1S7S) (IS) Russr. Han* Rudolf 'TormaUaa aI Polydilorlnslod Dtbsnsofnrans (PCOPr) from the Pyrolysis of Individual PCI fVin. RuloreoVIng Rooord | '^rPTisIssuIng th* following Hot of document* which consilluto* tho record tor this rulemaking, and rsqusst* commsnls on any other documents that should be Included. Document* wiU continue to be added to lb* record os HONS 214121 Fatftfii Ragfetor { Vol. 4fl. No. 58 / Friday, March 13, IftM / Propoaed Rule* 11083 appropriate, |nchidln| information tha National Fin Intldant Reporting aubminad In tatpon** n thl* ml*. Sytiam for 1982" (Novanbar 10, i3). A. Pnvloui Ruttmakinf Rscordi (3) USEPA. OPTS. EED, TalapHona Communication* batwaan DmIm (1) Official rolameUni rooordJfrom Kaahnar. EPA. and Cary Cired. Vantur* "PolyehJorlaittk Biphenyl* (PCS*) County Fir* Protection Dtatrtct Manufacturing, Procaaatnfl. Dtatributton "Frequency of PCB-Tranaformar Fbaa" bn Commerce and Ur* ftohibilion Hula" (Aufuat 22, 1923) publithad In lit* Federal Rayiatar of May ll.l7*(44FRHM4) (4) USEPA. OPTS. EED, Totaphona Communication* batwaan DanlM (2) Official nlamaklni record from "Polychlorinated Biphenyl* (PCBafc * Kaahnar. EPA. and Maf PtatrOM. Pacino Caa and Elactrtc. Information on FCB> Diapoaat and Martini Final Rajulatioc" fublithad In tba Fadaral Ragiatar of Tranafonner Fin In Son Prondaoo" (December t. 1M|. ~ abruary 17.1972 (43 FR 71|. 13) Official mlamakintrecord Iran Polychlorinated Mpbanyla (FCBa): - Mtaufaetam, ProemInk DtatribaUcn, and Um la Cteaad and Controlled Waala Manufacturing Proeayaat" publlabad In tKa fadaral Roylatar ol Oslobar 21,1M2 (47 FR 46NO) 14) Official rulamaklnjiacoH from Polychlorinated Blphaayb (FCBa); Manufacturing. Proeaaalnt. DUtribuDen In Commero* and Uaa Prohibition*; Um In Electrical Kquipmant" publithad In tha Fadaral Regular of Auguai 22. lgM (47 FR 17942). - (I) Unltad Stataa Daportmant of baigy- Contar for Pin Raaaerch, "Devofopmant of FUmmobUtty thttaria for Ttenafanmar Diolactric Fluid*" (March 1M0). (a) Pacific CM and Electric Company. Lattar in Mr. Harry Saraydarian, USEPA Ration DC "PCS TTOnafannar FIro in Son Frondaoo" (Jaita 10. 1N2). (7) PadRc Car and Electric Company, Uttar to Mayor Dianna FainaMn, "Plan to Remove FCB-TmaafonMTt" (June Ml 1M3). (*) USEPA, OPTS. EED. Rawed of MaoUis batwaan EPA and Dow 8. Support Docvmfit* `Comini, `TtatroflUfnaaadPGR (11USEPA. OPTS. EED. Taiaphont Cmanunlcatloni between Dan1m Kaahnar. EPA. and Patar CUlaon. G8A. 'Tratjuancy and Natufa of PCS Tramformar Flraa" (Odobar 4. IMS). (t) USEPA. OPTS. EEO. Tataphonc TruafonMr Flraa" (September 30, MM). (*) Chemical Raiulatton Reporter. Article on PCSTranaformar ITroa. UA Cun Expact 1.110 Tmuformar Fbaa Rich Year. Ftnaiah Sdontlat Tati# NOW (September 23. INI). Communication# batwaan DaaiM (to) form* Rantanon, Director Krohnar. EPA, and David Endloott, General. biaUtnto of Occupational National Fin Admlniatratlon. "Data In Health. Utter to Don Clay. VA. "(netdanoa of PCB-Tranafotmat Flr*" (Novambar 23,1M3). (11) USEPA. OPTS. EED, Racord of Moating batwaan Bob Waalln of Venar and DanlM KMhnar, EPA. "PCSTraiuformar Flraa baua" (weak of September M, INI). (12) USEPA. OPTS EED. Telephone Continualcation batwMH Lao Kokotika, EPA and Slav* Farrow, USEPA Region V11L "PCB-Traoafonaar Flraa and Belated Inddanta" (October 121M3). (ill Bueer, H. a (1479). Tormation of Mychtorfnoted Mauofurana IPCDFa) ana Dibetuo-p-dtexin* (PCDDt) from the Pyroiyala of Cholorobaaionaa." Chamoaphtrv No. 2 1J~424 (14) TU Now York Tlreae. "Florida Utility Will Raptaoa Tronaforman Made With Toxic PCB'*H (Tkanday. September 21M2). (Ill USEPA. OtRea of Water Refutation* and Standard*. Criteria and Standard* DtvMon. "Ambient Water Quality Criteria for 12.72Tafeachoiordibanao-p-dioxJa" (February 1M4). liat of Bdbfocta In at CP* Part Tti Hamdan* material*, Ubattng. PolyeMortnatad biphenyl*, Reporting and raeordkaoplnf requirement*. Earironaeantel protection. Dated: March 11M04. pu aw KJW outam oca* ran m m HONS 214122