566 CHAPTER 31 1965 Guide And Data Book Table 2 .; Gradar Equivalents of Rectangular Ducftfor Equal Friction and Capacity 0taeufam fat lodm , /jr Dud Design , ToWe 2___ Circular Equtvatunh of Rectangular Ducb for Equal Frtctioo aud Capacity {Conefaded) 1 OinMmioed b Incfcct 567 SS 88383223 SSS323 3 8 8 8 8 8 8 8 8 8 8S S 8S SSSS8 gggSfB 8 Dynamic losses vary substantially as the square of the mean velocity of foe air, and are therefore conveniently ex pressed as a fraction of the velocity head: mftere _. . . Ht " dynamic pressure loss, inches of water. V mean velocity of air flow, feet per minute. C = an experimentally determined constant (dynamic loss coefficient). . Where different areas are involved, subscripts are used to denote the area to which the coefficient applies, as Cr for inlet area, C for outlet area, and C* for orifice area. The dynamic loss coefficient C is dimensionless and repre sents the number of velocity heads lost at the conduit transi tion or bend. Values of the dynamic loss coefficient for elbows and other duct elements have been determined experimentally and are given in Tables 3 and 4. It should be noted, however, that absolutely reliable dynamic loss coefficients are not yet, available for all duct elements, and the information available for pressure losses due to area changes is generally restricted, to symmetrical area changes. . Fig. 7, which shows the relation of velocity pressure to velocity for standard air (F- = 4005' can-be conven iently. pgod to find, the total dynamic pressure loss for any duct element with inown dynamic loss coefficient C. PRESSURE LOSSES IN aBOWS Dynamic-loss coefficients are nearly independent of the air velocity and' are affected by the roughness of the duct Walls only in the case of bends, for winch the dynamic loses are often grouped with the friction losses to facilitatedesign An ASiLRAE survey* of available data has indi cated`that tiie method of expressing the combined dynamic and friction losses due to an elbow as equivalent to the loss in a length L of similar straight duct is justified for design purposes, owing to the relation of the loss to the correspond ing friction factor/. , Fig. ,8 gives the additional equivalent length of duct in terms of widths W for elbows in- rectangular ducts; Fig. 9 gives.the equivalent length of duct in terms of diameters D for round ducts. When these curves for additional. equivalent length are' iised; the straight lengths of dnet between elbows should be measured to the intersection of their center lines. Example 6: Use of Fig. 8 for the calculation of elbow kisses. : - Givea the portion of a duct system shown in Fig. 10, determine the pressure loss between points A.and D. Air at standard tiohs is,being supplied at the rate of 2000 efrn .in 6 by 24in. galvaniseddnct of average construction. Elbows No. 1 and-Z have center l'n* radii of 18 and 9 in., respectively.