> l Report on a Replacement forAskarels Silicone-Based Dielectric/Coolant Faces Manufacturer/User Evaluation Using askarels for transformer cooling is dangerous because of the environmental hazards involved, and monitoring, controlling, and dispos ing of PCB's is costly. Mineral oils present a flammability problem, and Oas- and alr-cooted transformers have high operating losses. Whon he must find an adequate substitute for askarels, the power transformer manufacturer 01 user needs an environmentally safe liquid coolant with high temperature stabil ity, excellent dielectric properties, and low flammability. Dow Corning Corp., Midland, Mich., believes that It has developed a silicone coolant* {hat meets these requirements. The coolant, which is much less flammable than typical mineral oils, has a higher (lash point than many askarels. It is sell-extinguishing in static tank burns and simulated catastrophic transformer failure tests. Three years of evaluation have shown that existing transformers can be retrofilled with the liquid success fully. As a result, the company has announced the controlled availability of the material In a cooperative plan to gather additional practical data on a massive scale. Silicone liquids rank among the least hazardous of industrially used chemicals: their low toxicity to aqua tic. bird, animal, and human Hie Is well documented, according to Dow Corning officials. Evaluated by Un derwriters' Laboratory, the silicone liquid coolant for transformers re ceived a flammability classification of between four and five (on an index which lists wateras zero and ether as 100). Askarels are rated at two to three on the same index, and mineral oil, though not listed, would likely be rated between 10 and 20. Data Program Dow Coming's Commercial Ser vice Life Data Program, under which the silicone liquid will be made avail able to the power transformer indus try, provides for the collection and dissemination of performance data on the silicone coolant in targe scale use under many types of operating conditions. II will involve three-way cooperation and exchange of infor mation between transformer man ufacturers and users and Dow Corn ing.The plan Is necessary to Inspire confidence in the liquid as a replace ment for askarels. The primary objectives of the prog ram, which calls for the installation of S00 to 1000 power transformers in the 500 to 10.000 kVA class containing silicone dielectric coolant, are: t) data -- to gather operational informa tion tor three to five years, compile 'Dow Corning S6t Silicon* Tr*nifom)*r Liquid. It It chamlcaily Idanlieal to polydimathyl ailexane liquid* which th* corporation hat prodocad tor 30 yairt, but th# n*w liquid it menufacturad to tightar apaclticatlom lor alactrical uaa. HlQhcunenl faults in closed tanks tilled with (left to right) fate Internal failures In transformers Silicone fluid ox- mineral oil, silicone liquid, and askarel were used to simu- . ploded with less violence than either mineral oil or eskarel. HONS 0 3 5 0 5 2 fnsu/etronfCircuifs - Juno 197G - St Statistical performance records, end distribute results to participants; and 2) approval -- to obtain complete qualification of the silicone liquid as a replacement for transformer asKarels. Dow Corning has presented data based on a concept of full-spectrum safety to Panel 13 responsible for the appropriate National Electrical Code (NEC) sections covering the installa tion of transformers. Simitar presen tations have been made to Factory Mutual, Industrial Risk Insurers, Hart ford Steam Boiler, OSHA, UL, NBS, and others concerned with the safety of elocWical systems. These agencies atso are evaluating silicone liquid in appropriate test programs tocoritirm the safety ot this liquid. Results of those tests will guide the establish ment ot new regulations and revised codes. Presently, three transformer man ufacturers are ready to accept orders tor silicone liquid filled transformers: 6mall Power Transformer Div., Westlnghouse Electric Corp., South Bos ton, Va.; RTE and RTE-ASEA Corp., Waukesha, Wis.; and Ferranti* Packard Ltd., Toronto. Can. All par ticipated with Dow Corning in a STEREOZOOM WITH Now you can dispense with hot little lamps on wlQQiiy arms and fluorescent tubes that soem to fade as you zoom up. * Enjoy the brilliance, high odor temper ature of a 150 watt halogen source conveyed and concentrated by fiber optic ring lamp. Vertical adjustment produces'subtle variations in illumina tion and corresponding 'revelations" ot specimen surface structure. Supplied for H/l Stereozoom and similar Inatrumenta. Applications limited only by your Imagination. HACKER Soi645 1 INSTRUMENTS INC. FairfkeW, NJ. 07006 (201)7261450 Circle No. 95 on Inquiry Card . .tunr* toys Transformer Oil Silicone Liquid Kcel/min. FLAMMABILITY AND FLASH POINT . Flash Point c r 150 30? 277 530 Fire Point c 'F '65 329 316 600 . C(>mt)u$ion 15000 900 Oil Aska'el Silicone DIELECTRIC CONST ANT. DENSITY AND VISCOSITY Dielectric Constant Viscosity $ 75* C (Ceniistokes) Lb /Gilt Imp " US 2 3 5 85 7 1 45 6 1525 127 27 20 96 60 cooperative evaluation of silicone li quid coolants. fled unit if the same temperature rise is f to be maintained. Temperature rises up to 10% higher hsve been observed; ^Element ot Rlakj when silicone was substituted di-* rectly for olt or askarel. If additional Until silicone transformer liquids are accepted fully under the National cooling capacity is not provided, a transformer may have to be derated.! Electrical Code and blanket approval is given by Insurance companies, Maintenance Procedures customers must recognize that there may be an element of risk in placing Standard maintenance procedures silicone filled units in hazardous loca developed for oil or askarel tilled tions. This must be weighed against transformers generally apply to the consequences of strict environ silicone filled transformers. The only mental regulations proposed tor as- check required on the silicone liquid karel spills and the fact that the sole fri is for dielectric strength using liquid supplier of askarel plans to phase out li tilled transformer procedures in ac of production. cordance with ASTM DB77 except Responsibility for proper clear * only one breakdown per cup filling ances with insurance underwriters, should be made. government regulatory agencies, and The dielectric strength of the silt local code authorities rests with the - cone liquid is equivalent to askarel transformer buyer. Three leading fire and oil. The liquid exhibits a high de underwriters -- Factory Mutual. Hart gree of thermal stability. Low volatil ford Steam Boiler, and Industrial Risk ity and resistance to thermal oxida Insurers -- have indicated their wil tion should enable the liquid to main- lingness to approve Individual instal *. tain insulating and other functional lations on a case-by-case basis. Until ! properties for extended periods ot the National Electrical Code is re time at high temperatures vised, it is also necessary to obtain The explosion hazard under catas waivers from OSHA to install silicone trophic fault conditions is not totally filled transformers. The necessary eliminated with silicone coolants. petitions for such approval have been Under catastrophic fault conditions, submitted to OSHA. internal arcing and decomposition of Pumping equipment (or the sili the dielectric coolant can cause viol cone liquid must be selected with ent transformer explosions. Trans care because the liquid does not ade formers cooled with mineral oil. as quately lubricate certain pump de karel. and silicone fluid were sub signs. Poor lubrication will cause pre jected to catastrophic failures byOow mature pump failure and contami Corning. All three dielectric coolants nate the liquid with metal particles. exploded, but only the mineral oil A silicone liquid-filled transformer * iwilt cost more than an equivalent as jkarel filled unit because of the higher f cost of the silicone liquid and be continued (o burn after the explosion, The askarel exploded violently, but quickly self-extinguished Silicono exploded with considerably less viol- cause the difference in viscosities \ ence and also did not continue to I(silicone is higher) wifi necessitate burn, ft limited the arc duration and additional cooling for the silicone til I self-cleared HONS 035053