Document 6nOnmVBJoeMOm4v5Yn6o2LKg
ESSO CHEMICAL CANADA
P.0 Box 3004, Sarnia. Ontario. Canada N7T 7M5
0950D
SARNIA CHEMICAL PLANT W.D. REID Manager
April 30, 1985 File: 1793
Esso
CHEMICALS
Certain-Teed Corporation Pipe & Plastics Group P.0. Box 253 Sulphur, Louisiana 70663
Re: Survey Results Corrosion in Recovery System
Dear Mr. C. A. Gellner:
Please find attached a copy of the survey results on: Corrosion in the Recovery System.
In Summary:
No. of Respondents: 25
Observations:
Experienced Pit Corrosion In Settling Drum Stagnation Acidic Condition Temperature (>40 F) Iron Chlorides Corrosion Inhibitor Filter Solids Antioxidant Monitor For Pitting
(72%)
YES NO N/C
18 6 1
20 5 -
11 10
4
11 11
3
20 - 5
13 1 11
14 1 10
9 15
1
8 16
1
13 11
1
14 11
-
Cont'd . . . /2
CTL020306
A Division of IMPERIAL OIL LIMITED
2- -
Other general observations: (1) some of the respondents have had success in thwarting pit corrosion by using coatings (e.g. epoxy), glass-lined vessels and even electropolishing. None had any experience with using Titanium or equivalent materials; (2) I sensed a general confusion as to the difference between pit corrosion and chloride stress corrosion cracking. Therefore, some of the respondents who have indicated experience with pit corrosion may in fact be with C.S.C.C. Possibly the questionaire itself added to this difficulty, because the answers to a couple of other questions were also misleading. Any future survey questions should take this observation into account to make the results as meaningful as possible.
As a final note, also find attached a blank copy of the survey questions that may help you when reviewing results as well as a copy of my presentation.
Finally, I thank you on behalf of Esso Chemical Canada for your participation, and if you have any further questions or comments, please do not hesitate to contact me (519-339-2061).
NP/db Attachments
Best regards,
ESSO CHEMICAL CANADA
<n/t
N. Pellarin P.V.C. Technical Supervisor
CTL020307
Company
Quest loot: 1. E*perleed
Materials
3. Mat'l/CcalIngt Successful
1 2 34$ < 7
NO Vet Yet Yes
"
cs/ss
is/ss
CS
cs/ss
C-Cpoay ss/su
C-AI
Yet CS
-
Yet Yet CS SS
- Clectro.
No -
-
). Sett I Inf OruM
Ves Vet Yet 7ei Yet Yes No vet
4. Corrosion In Onr*
No
S. Stagnation flange (hr.|
No
1. Condilions riilcKitll iw. I*M Chlorides (ppn) Iron (pp|
t. Its In Carryover
7 Aid.
-
Vet
1. Other RulId-Up
No
Yet Vet Vet Yet
Yet No *ts Vet
u-)
()
HI
m
KO Mo -
4
4
7- 8
S *4
SO 10 (8 48
80
-
-
trace
Yet
Yes
-
- trace S
Yet
Yet
NO
trace
trace
NO
-
No Poly.
No
NO
-
-
NO ()
NO SO
0.1
-
t. Corrosion lh. U/S 10. filter Solids U/S
No
No
II. Antloaldants U/S pH Change
I?, f Itanium Vessel Experience
ves 1st
No
11. Pitting Monitor Method
No -
NO NO Yes Vet No Yet NO * " (ISM * " "
Yet No VttS Yet H No No
No
No
HO Vet
Yet Yet
Vet
- t " lie) - -
NO No NO No
No No No
Yet (ust
Yet (US)
let (US)
NO -
Yet (us)
Yet -
-
9 10 11 1? I)
Yet No Yet Yet vet
SS
SS -
SS
- - C-Xynar SS
Yet No Yet Vet Vet
Yet No No Ves NO
No No Vet No Yet
-
(I M
(i*)
i
4 No 1-3
40
40 - SO
n
Yet - Yes
Vet - Yet
Yet NO let
Yet Vet
7 Yes Yes
Ves
-
Vet NO Yet Vet (C) |C)
NO No No ves
Yes No Yet No - IM No MO Ko NO
7 so
No Vet
No
No No No
No No Yet NO Vet
-
.
-
(US)
Holt? ISP >K US C P fl/PN U/S
trtsodtwn phoiphitt - h/drogwlnonc - ottrasonlc - c ivtl l< * phtnol - radiography and pen. - upstream
Iftf llqwldt
14 IS 14 i; : 19 30 31 33 .31 34 3S
loins
Yd Yes Vet vet SS CS SS CS
CS/SS
SS
CS
Yet No Yet Yet
No Yet NO No No Vet
id (U
NO Tfl Yet Yes
Yes
SS
Cl V3A (SS) SS (304)
C-Cpoay
Cl
NUd Steel
Vet Its Vet Vet Yes vet
No Yes No No NO Ho
NO Yes No Yet Yet Yet () . <) in ( Ho.) (-id
NO `
AtSI SS
No
No
(>
MO * cs
Yes NO
Yes IM
1 . 100 -
-Yet -
NO
40-40 Yet Yet
Yet
Yet
-.
Yet
10 * NO MO
Vet
Yet
Yet -
N Vet
.4
SS 8S --Yfl Vet
Yes Yet
NO Yes
7.S No too An*.
IS Yet 31
Yet No
NO NO
NO No
3 3- 3 - SO An*.
S I.S vet
Vet 0.)
-
Yet Ho Vet
Yet ret
NO
NO No No
Ves 100 Vet Vcl ves ves
NO
No -
NO Yet
Vet
Ho
No
NO
No Yet Vet
NO
Vet --
MO Yet
Yes
No
NO
NO
Yet
* (C) - * * *
No
NO No NO No
HO NO NO NO
No
No Yet Ves - No NO
No NO NO
l: 18 k: t N/C: 1 CS: S SS: 9 CS/SS: 3 Cl: 1 h/i.
Coatings: 4 CS: 3 SS: ` Cl: 1 C lec tropol 1 thing: 1 N/C: 10 (IAS
V: 30 N: S N/C:
V: 8 H: IS N/C: 7
V: II n: 10 N/C: 4 flange: 1 hr. to 4 months lyp lc a 1: 8 - hr.
AcldlCt II latkt II N/C: 1
flange: Mi. lo
lOI'f
1: 1] Hi 1 H/C: II
V: 14 N: 1 N/C: 10
V: IS N: 7 N/C: )
V: 13 N: 7 a/t: 4
v: 9 n: IS N/C: 1
V: 8 N: 14 N/C: 1
V: 1) *
V: -
N: H N/C: 1 N: ?S N/C:
No No Vet Ytl
- - (us) (us)
No Ho Vet No
- - (us) -
No Yet
No
-
/fi
-
NO v: 14 n: || n/C;
- V: Hi - M/Cl
CTL020308
VINYL CHLORIC SAFETY ASSOCIATION 1984
Vinyl Chloride Recovery System Corrosion Risk Management Survey
1. Have you experienced pit corrosion problems in the recovered monomer system? In what materials of construction.
2. What materials and/br coatings have you had success with? Problems with?
3. Do you use a settling drum system to remove water from recovered monomer?
4. Have you experienced pit corrosion in the settling drum?
5. Does the water sit stagnant for extended periods of time? How long?
6. Is the environment in drum acidic?pH? warm? ______ Ave. Temp. ? with Cl' present?ppm? with Fe present?ppm______ ?
7. Have you experienced resin carryover to the drum?
8. Have you experienced any other form of build-up? 9. Do you add corrosion inhibitors in or upstream of the drum?
10. Do you filter solids upstream of the drum?
11. Do you add antioxidants to the recovered monomer upstream of the water settling drum? Does this affect water pH?
12. Do you have experience
*-k*'
recovered monomer service?
of tit^njinn in the
12a. Was it satisfac>:n*yC
CTL020309
.../2
Vinyl Chloride Recovery System Corrosion Risk Management Survey (Continued)
12. Do you monitor equipment for pitting? With what method? (eg. radiography)
YOUR RETURN ADDRESS FOR SURVEY REVIEW IF DESIRED.
MAIL RESPONSES TO: 1746J/jrw
M.L. Marson Esso Chemical Canada
P.O. Box 3004 SARNIA, Ontario . N7T 7M5 CANADA
Telephone: (519) 339-5944
CTL020310
CHEMICALS
VINYL CHLORIDE SAFETY ASSOCIATION MEETING - 1984
SUBJECT: CORROSION IN RECOVERY SYSTEM
SPEAKER:
N. (Nino) Pellarin PVC Technical Supervisor Esso Chemical Canada
CTL020311
CHEMICALS
VINYL CHLORIDE SAFETY ASSOCIATION MEETING - 1984
CORROSION IN RECOVERY SYSTEM
BACKGROUND:
- TWO 316 SS INERTS DRUMS IN RECOVERED VCM OPERATION. UPSTREAM PIPING PRIMARILY CS.
- DRUMS ARE EXPERIENCING PIT CORROSION.
- PITTING IS REPAIRED BY LIGHT GRINDING AND WELDING.
- CONCERNS:
(1) INTEGRITY OF DRUMS: LEADS TO ENVIRONMENTAL RELEASE. (2) REPAIR TECHNIQUE: LEADS TO CSCC.
CTL020312
CHEMICALS
VINYL CHLORIDE SAFETY ASSOCIATION MEETING - 1984
CORROSION IN RECOVERY SYSTEM
MECHANISM: - CORROSION PROTECTION FOR SS DRUMS PROVIDED BY OXIDE LAYER. - IRON CHLORIDES CHEMICALLY "BREAKDOWN" THE OXIDE FILM. - STAGNATION PREVENTS RE-PASSIVATION. - HYDROCHLORIC ACID ATTACKS THE UNPROTECTED SITE. - A PIT DEVELOPS. - PROPAGATION ASSISTED BY THE ELECTROCHEMICAL EFFECT. - FACTORS THAT ACCELERATE PROCESS: (1) ACIDITY (2) TEMPERATURE
CTL020313
CHEMICALS
CORROSION IN RECOVERY SYSTEM
VINYL CHLORIDE SAFETY ASSOCIATION MEETING - 1984
FIG. 1: BREAKDOWN OF OXIDE FILM
FIG. 2: FORMATION OF n!T< CTL020314
CHEMIC,
VINYL CHLORIDE SAFETY ASSOCIATION MEETING - 1984
CORROSION IN RECOVERY SYSTEM
CORRECTIVE ACTIONS:* - SHORT-TERM: PURCHASED GL VESSEL TO REPLACE MAIN SS DRUM. ONE DRUM OPERATION TO PREVENT STAGNATION.
- LONG-TERM:
CONSIDERING HAYS OF CONTROLLING OR ELIMINATING FACTORS.
CTL020315
CHEMICALS
VINYL CHLORIDE SAFETY ASSOCIATION MEETING - 1984
CORROSION IN RECOVERY SYSTEM
SURVEY: 16 RESPONDENTS
- OBSERVATIONS
YES NO N/C
EXPERIENCED PIT CORROSION (80S) IN SETTLING DRUM STAGNATION ACIDIC CONDITION TEMPERATURE * 40F IRON/CHLORIDES CORROSION INHIBITOR FILTER SOLIDS ANTIOXIDANT MONITOR FOR PITTING
13 3
7 72
6 82
6 82
14-2
8-8
78 1
4 11 1
87
1
11 4 1
NP/db 0277D
CTL020316