Document 6dbQXp1vOEZMg1xB0mBopdQ1
Monsanto
KtJm Copy/
MONSANTO RKStARCM CORPORATION / DAYTON LABORATORY / OAYTON. OHIO 4MOT
r\SC * Davton
iPirt /HCTOMl
RfRORT NO :
MPA-311
Analytical
TTH 01 MPOAT
RECEIVED
. RIPORT
JOI PROJCCT NO. OATS:
n* 00 COVCRCO:
3 Ji. (5n 1 2
July
iis:
JUL 2 7 ' --
""SSSSrKS**
TITtl:
ANALYSIS Of MOIJNP St RUM SAMPLtS FOR TCBs.
AUTHORS:
Key u. Nohlc, Frederick D. Hilenan
FILE COPY
A. report on th,,e ana.lysis L-oiJf fP.LC-Bi s Ri-nMOhuaanfSOseUrumfll is presented. Serum samples from 10 donors were analyred for PCBs. Results are presented in this report.
z / A
it
ii
Technical Appro
J. trod
Search Gnnp 'Leader CC/MS Technology Leader
Approv ed by:
Robert F. Ivory
CJ
Environmental Analytical Sciences
Center Service Project Manager
Approval date:
7'f'71/ f2*
RESTRICTED-DISTRIBUTION*fsemtoverj
COMPANY CONFIDENTIAL TNIWMbNMMrflkNnMMACMMNMlNMinilMMMlN
MONS 022515
D I S TH I [ U T l O
COPYWUMMW
I
V. G. Bard J, J. Brook,
3 F. P. Hilcaan
4 R. K. Noble
$ .1. P. k i l son
t> R. F. I vo rv 7 (>. Kutler
8 C. Rouish 0 i. !.. it* 1 i-r;ir
10 lent r.ii! : .Is*
11 Techr. . .i! lie per: *
L 1 i IM! V
fin
1250
1250 1:50
G3*G 1250
C2KB G-'kr, t::r.F 1'5c R5C
ABSTRACT ONLY
*. K. Flitcraft 12SP
R. N. Scott
1KI
NOilJj:
r jhut ion of this report is restricted. Request* for .iJh:tirnal copies should be made through the principal
contact at the Monsanto location involved or the Manager. Lr.\ ircnr.cntal Analtyical Sciences Center, I'ayton Lahorator i\r. tc:., Ohio.
( C ) \ f I [' ! \!l,`.
MBM.' ho town MW M upon loqpoati QNm WW report to control. Woo. Davton.
HONS
022516
ANALYSIS OF HOUND SERUM DONORS FOR PCBs On 22 June 1992, samples of blood serum were obtained fro* 10 donors at the Mound facility of Monsanto Research Corporation (MRC*Mound). These saaples were then transported to the Dayton Lab (MRC-Dayton) for analysis of serua PCB levels. Full QA/QC was run on this set of saaples as discussed in the meeting of 14 April 1982 in St. Louis. This entailed duplicate analyses as well as low and high spikes for each sample. Samples were analyzed according to the attached method (MRC Method *2413PREP RO). The low spike of the serum samples was at 42.4 ppb of PCB distubuted among 37 separate chromatographable peaks and ranging from 0.10 ppb to 3.22 ppb with a median spike level per peak of 0.94 ppb. The high spike was at a level five greater than the low spike. The results of the analysis for these ten donors are given in Table 1. The average subtracted blank as 1.0 ppb. The minimum detection limit varied from sample to sample in the
range of 1 and 2 ppb.
HONS
TABLE 1
RESULTS OF MOUND SERUM DONOR ANALYSIS FOR PClj
Donor
1
> J s 6 1 9 10
Sample iPPb >
4.1 5. 6 4.1 2,4 2.0 3.7 1." 4.1 6. 3 6. 7
Replicate
IppM
6.6 5.6 1 .: 2.4 2.4 :. s 2. 2
4.0 4.7 8.1
Averi|e
(PPb>
5.5 5.7 :.9 2.4 2.2 S.2 2.0 4.1 S. 6 7.4
Low Spike recovery
S7.SI 1001
98.71 78.25 1025 91.05 75.41 87.85 lilt 74.15
Ave 90.75 o -12.45
High Spike recovery
66.45 61.61 73.35 ST.St 89.71 70.35 61.11 66.45 71.51 65.51
09.1'. 8.oi
2
MOHS 022518
MRC Method >24-13-Prep-RO
Title
Analysis of Polychlorinated Biphenyls in Blood Serua
Noaenclature:
In this paper, the tera "PCB" will be used to refer to any coabination of the 209 different
chlorinated biphenyls. The tens "class" will refer to PCI's having the saae degree of chlori nation regardless of the positional substitution of the chlorines. The ter* "isomer" will refer
to a PCB haring a specific arrangement of the chlorines in the biphenyl.
Appli :ation:
This nethod is applicable to the analysis of part per billion (ppb) levels of PCBs in blood serua based on a ng/aL basis. This
aethod can be applied to the analysis of trichlorobipheny1s through decachlorobipheny1.
Precision and Accuracy:
The precision and accuracy for this analysis will je derived froa the QA/QC data.
Safety:
Persons handling PCBs (and any other cheaicals) should faailiarize theaselves with current safe handling procedures for those chemicals.
Authors:
Roy h'. Noble, Cynthia
Heflin
Approved:
Bate:
-- J/
/*/*_
Scope and liaitationi of Method:
This aethod is applicable to the analysis of PCBs in blood serua. The aethod has been successfully applied in this laboratory under
the conditions set forth in this paper. However, this does not iaply that this aethod can be used in another laboratory without
validation within that laboratory.
Equipment and Reagents:
1. Silica Gel, Fisher chroaatographic grade, 100/200 aesh or equiva lent.
2. AgNOs. Eastman Kodak Co. X491
3. Distilled deionlsediHaO, supplied in house.
3
HONS 02E5H
4. Ns,SO., anhydrous, granular. S/9 IIAI 3191.
5. All solvents are Burdick and Jackson, "Distilled in glass grade".
6. Aroclors 1249, 1254, ar.d 1260 from Monsanto Conpany, St. Louis MO.
7. PCB isoners iron Ultra Scientific Inc., Hope, Rl.
4. Ccntrific Centrifuge* Fisher *04*978.50.
9. Vacutainer Blood Collection Tubes lOaL. plain, sterile red top. S/P - B-29S3-54.
10. SmL Serological pipette, sterile, disposable, glass S/P - P464 15.4
11. 15nL culture tube, - (16 X 125 am) disposable with teflonlined screw cap. S/P T-13S6-S.
12. Genie krist Action Shaker. Vortex Mixer
13. Burrell krist Action Shaker.
14. Glass kool - untreated Supelco *2-0584.
15. 50 ml Centifuge tube * disposable, glass Corning 8060.
lb. hater Bath - S/P 6990.
17. Sea Sand - Fisher S-25.
18. Auto Sampler Vials - '1.8 nl glass with teflon - lined screw caps. Supelco *332-86 and 3-3210.
Sampling:
Hunan blood samples will be drawn by a certified medical technolo gist, nurse, or nodical doctor. Each sanple will be drawn in an individual plain, sterile vacutainer and sent to the Dayton Lab following appropriate shipping and preservation procedures. Upon arrival at the laboratory site, each sample will be centrifuged at 3000 rpn for 10 minutes to separate serum from the red blood cells. A 2nL aliquot is then tranferred by a sterile disposable pipet to a ISnL teflon lined screw capped extraction tube. The extraction tube was previously cleaned with hexane and baked over night at 600*C in a glassware oven. Refrigerate samples at 4*C until proceeding with extractions.
Extraction and Clean-up Procedure:
1. Remove samples in extraction tabes from refrigerator and allow to warn to room temperature.. If appropriate spiko the sample with a standard solution of KBs in diaethyl sulfoxide (BMSO).
'4
HONS 022520
2. Add laL of aathsnol to the sanples to donaturo aorua protoins.
]. Add SaL of hexane to the extraction tubes and aix on a vortex ixer.
4. Agitate on a waist action shaker at naxiBuai speed for 10 inutes.
5. Separate serua and hexane layers by centrifugation at 1000 rpa for 10 ainutes.
6. Pool hexane extracts for each saaple in a second ISaL screw cap tube containing laL of nonane, and narked at a volune of laL.
7. Repeat steps 1 through 6 two tines.
I. Concentrate all extracts to laL by evaporation under purified nitrogen in a heated sand bath (60*C).
9. Prepare liquid chronatographv colunn by inserting a glass wool plug into a SnL disposable pipet, then filling the pipet with
2 cn of anhydrous sodiun sulfate. 1 cn of lot silver nitrate deactivated silica gel previously prepared according to the nethod of Lanparski et aK ' Top this colunn with an additional
2 cn of anhydrous soJTun sulfate and prerinse the colunn with lOnL of hexane.
NOTE:
In preparation of the AgSOj-silica gel colunn it is
inportant that the Lanparski procedure be followed exactly to obtain reproducible colunn packing. For
that reason, a brief outline is given below but one should
faniliarize thenselves with the full procedure. Chroaato-
graphic grade 1002200 aesh silica gel is rinsed with w7SaL nathanol, and then with w7SbL nethylene chloride,
and baked overnight at 1S0*C under nitrogen purge. The silica is allowed to cool to anbient teaperature under
nitrogen purge and a known asraunt is weighed out. Silver nitrate is then weighed into a separate beaker so that
the aaount of silver nitrate equals ten percent of the total weight of the silver nitrate plus the silica gel.
Siaiiarly distilled deionized water is weighed out so that tho weight of the water equals 30t of the total
weight of the silica gel plus the water. The water is then added to the silver nitrate and this solution is
then slowly added to the silica with stirring to produce a unifornly coated silica gel which is allowed to stand
for a niainua of SO ainutes. The silica gel prepared by this nethod is then baked in an oven under nitrogen
S
HONS 022521
pur| at 40*C for 10 ninutes and the temperature Is than increased. at*d.2*C/minute until, raackiag a final tem perature of 1ZS*C where It is held for a minimum of
IS hours. Tfca 101 AgNOj silica gtl is stored in an aaber glass bottle insidt a dcsicator until use.
10. The sanple Is than placed on the head of the prerinsed column
and eluted with 30aL of hexane which is collected in a SOnL centrifuge tube preaarked to a voluae of lal.
11. The eluant is than concentrated to laL as in step S and subaitted for GC-EC analysis.
11. A known aaount of internal standard, octachloronapthalene(OCK), is added to account for differences in final voluae and vari ation in the electron capture response over the course of the analytical runs.
IS. The saaple is analyzed by capillary coluan gas chroaatography-
elrctron capture detection with splitless injection technique us ini; the following conditions:
gas chromatograph: Varian S700 coluan: 30 a wide bore SE-54 (or DB-SJ sold by Jgb
Scientific
injector teap: :sdc
detector teap: 350C
initial teap:
110C
prograa rate:
3C/min.
final teap:
2'5eC
linear flow velocity: 10.g ca/sec of 101 Methane
901 Argon
head pressure: 9 psi
A ainiaua of throe standards at different levels are run for each set of saa^les. These standards contain the OCX and a mixture of PCBs representing a broad rang* of PCBs in the chlorine classes analyzed. These standards were previously calibrated by GC-MS and GC-F1D against individual isoaer stand ard for each class.
14. Calculations are performed on a peak by peak basis using a least squares regression analysis. Prior to the regression analysis all areas are normaliied using the OCX to account for differences in final volumes and electron capture sensi tivity changes over the coarse of the GC runs.
deference:
1. 1. L. Lampsrski, % 4. Bestrick and K. M. Stahl, Anal. Chen.. SI, 14SS (197).
HONS 022S22