BIODEGRADATION (BOD/COD)
TEST SUBSTANCE
Identity: Mixture containing perfluorooctanesulfonate which may also be referred to as PFOS, FC-95, or as a component of FC-201F. (1-Octanesulfonic acid, 1,1,2,2,3,3,4,4,5,5,6,6,7,7,8,8,8heptadecafluoro-, potassium salt, CAS # 2795-39-3)
Rem arks: The 3M production lot number was not noted. The test sample is FC-201F. Current information indicates that FC-201F is a mixture of 3.0% PFOS, 36.0% diethylene glycol butyl ether, 36.6% water, 8.25% acrylic foamer, 7.0% sodium octyl sulfate, 6.0% sulfonated alkyl ether sodium salts, 3.0% triethanolamine, and 0.15% tolyl triazole.
The following summary applies a mixture with incompletely characterized concentration o f impurities. Data may not accurately reflect degradation potential of the fluorochemical component o f the test sample.
METHOD:________________________________________________________
Method: DIN-standards according to the instruction defined by the German Standard Procedure for W ater, W aste W ater and Sludge Examination Type: Aerobic GLP: No Year com pleted: 1993 C ontact tim e: 24 days Inoculum : Not noted.
RESULTS__________________________________________________
Chemical Oxygen Demand (COD): Biochemical Oxygen Demand (BOD):
5-Day: 24-Day:
11,000 mg/kg
6250 mg/kg 8250 mg/kg
Rem arks: Report isin German; English summary provided
C O N C L U S IO N S ____________________________________________
No reliable conclusions can be derived from this study. The indication is that the majority of the product components are readily biodegradable.
000318
Subm itter: 3M Company, Environmental Laboratory, P.O. Box 33331, St. Paul, Minnesota, 55133
DATA QUALITY___________________________________________________
Reliability: Klimisch ranking 4. Study lacks description and records of the method followed. The sample purity was not properly characterized and the study lacks analytical confirmation of the amount of fluorochemical proportion in solution. The testing was conducted on a mixture with chemicals having varying degrees of biodegradability, leading to potential misinterpretation of the results.
R E F E R E N C E S _______________________________
.______________
The COD and BOD studies were conducted by the Hygiene Institute for the Ruhr District, Gelsenkirchen, Germany, 1993.
O T H E R ________________________________________________________
Last changed: 6/26/00
000319
EXAMINATION AND ASSESSMENT OF SEWAGE BEHAVIOUR
YOUR LETTER ETC.
Within the framework of the a/m . order the product Light W ater FC-201 F (manufactured by your company) was tested with regard to its biological degradability and its reaction towards higher and
lower trophic levelled aquatic organisms. The mentioned product is a liquid which is miscible with
water in every ratio. It shall be used as a fire extinguishing agent in a concentration range from 1 to
1.5% .
v
.The analytical work was earned out corresponding to the specified DIN-standards resp. to the instructions which are set down in the German Standard Procedure for Water, W aste W ater and Sludge Examination.
The results are described as below by outlining each examination procedure applied. .y
1. BIOCHEMICAL DEGRADATION
The biochemical degradation rate of the product Light W ater FC-201 F (1% aqueous solution) was determined via the biochemical oxygen demand. This procedure does not only show the extent of the microbiological oxidative degradation of the organic compounds but allows statements about the degradation kinetics because of the corresponding graph (ait.: curve) progression.
The chemical oxygen demand was used as calculating quantity with regard to the degradation rate. It was determined experimentally via the potassium dichromate method which can be used as a measure for the complete mineralisation of the product's organical substance (COD=11000 mg O^d). If you use this value as the required oxygen quantity for a 100 % degradation, the biochemical degradation, expressed as BODs (250 mg C yi), amounts to 56,8 %. As you can see from the attached graph on the biochemical degradation kinetics determined manometrically the biochemical oxidation is finished already halfways after four days. The final point of the microbiological degradation of the chemically oxidizable contents is reached -under the chosen test conditions- after 24 days and amounts to 75% . The available data indicate that you can classify the product Light W ater FC-201 F as easily degradable.
2. REACTION TOWARDS LQWEfl AQUATlC.QBGAfflSMS
A TTC -test with a 1% ready to use solution was carried out to generate a statement (coming dose to practice) about a possible toxicity of the product Light W ater FC-201 F.
r
The method is based on the reduction of 2,3,5-triphenyttetrazonum chloride to red formazan by the dehydrogenases of the living cells (activated sludge), depending quantitatively on the active ceils. By registrating the amount of produced formazan you can conclude immediately on the toxicity of a substance brought into a defined suspension of activated sludge and TTC, if you compare the results to a blank test. The semi-logarithmic graph makes d ear that the formation of formazan, expressed in absolute values, is at first higher than the blank value The further progression of the graph shows a decreasing formation of formazan with an increasing ratio of 1% Light W ater FC-201 F-solution. The blank value is reached at a concentration of 1 ml per 10 mJ total solution. An amount of 8 ml product solution leads to an approximate inactivation of the living cells; the adivity of the dehydrogenase comes almost to an end.
000320
3 . REACTION TOWARDS HIGHER AQUATIC OHQANISM8
'' V
............
..i
The examination oftheproduct lig h t W ater F C 201 F wfth respect to 8s fish toxicity was carried out
accordng to the method described in DIN 38412, part 20 (Rsh test) in a 1% utflBy-solution (a lt: ready
to use 7). A test solution made up of the product and cffluHoriw ater has been stocked with Laudscus
dua in a size range from 5 to 7 cm. The behaviour of the anknals has been watched for 48 hours.
During the test the temperature of the aerated test water was kept at 20 -*/ 1 *C . As a result of the test ft has to be stressed that only a 20 fold diluted testing liquid (1% solution) shows no more
negative effects on the animals.
S'* * f f *
..
4. i
m
m
a
b
x
'>
The product Light W ater FC*201 F is an organically polluted Bquid which is easily accessible to
biological degradation. The result of the TTC-test shows that draining the product through sewers into
a waste water puttying plant has no negative effects on the biological part of a sewage plant
Nevertheless ft has to be ensured that the 1% quenching Squid is diluted with water, e.g. domestic
waste water, In a redo of at least 1:10.
pc c ywi ^
W ater which contains the product Light W ater FC-201 F should not be drawn off into a drainage ditch. In this case the high organical pollution and the toxicity to fish would lead to a negative effect on the water eomposftion.
Signature
-
*
000321
's H ygiene-Institut
des Ruhrgebiets, Geisenkirchen
Institut fr Umwstttygforvi und Umweltnwdfein d raktor Prof. Dr. mad. Martn Exnar
j
; t., : .
. _. .
. Ilypan Initm r'aH c 1 0 1 2 *8 -<SS1?QMrlorgMn
f! i ;afns; A M D eutschland Gm bH ' ; >C arl-S chure-S tr. 1
4 1 4 5 3 Neuss
'V* !" 'J 'v; ; V
< S' - '' ;
Geisenkirchen
Rotthauser Strae 19 45879 Geisenkirchen Telefon (0209) 1586-0 Telefon Durchwahl (0209) 1586- 174/247 Telefax (0209) 1586- 251 45879 Geisenkirchen. 1 3 . September 19S
Dir.Tgb.-Nr. A 3469 E/93/C . Sachbearbeiter: Toiksdor^/ Wei
)
l: -vj"l ,
- s B etr.: .
A bw assertechnische Prfung und Beurteilung hier: Produkt Light W ater F C -201 F
:/ ' ;\
'
Bezuo: Ihr Schreiben vom 2 9 .0 3 .1 9 9 3 , Z .: N M C P /R V -TH
'' :V.V .-V ?-
Im Rahm en der v.g . A uftragserteilung w urde das von Ihrer Firma h erg estellte Produkt
Light W a te r FC -201 F hinsichtlich der biologischen A bbaubarkeit und des V erh alten s
gegenber hheren und niederen W asserorganism en untersucht. Bei dem angesprochenen
; ' - Produkt h an d elt es sich um eine m it W asser in jedem V erh ltn is m ischbare Flssigkeit,
. ; o> .v 'd *8 a*s Feuerischm ittel in einer Konzentration von 1 % bis 1 ,5 % ein g esetzt w erd en soll.
.Tinn
f . -r a r ; r- 's r - '' :
"
"
, ,, ,.
Oie analytischen A rb eiten w urden entsprechend den standardisierten D IN -N orm en b zw .
den in den D eutschen Einheitsverfahren zu r W asser-, A b w asser- und Schiam m urrter-
suchung niedergelegten Vorschriften d urchgefhrt. Oie U ntersuchungsergebnisse w erden
nachfolgend unter kurzer Skizzierung des je w e ils angew andten U ntersuchungsverfahrens
T h d ji ' g ew h lten Testbedingungen b e s c h rie b e n .-.
.... . -V
1 . Biochem ischer Abbau
i i 'fc "
Oie biologische A bbaurate des Produktes Light W ater F C -201 P (1 % ig ) w urde ber den biochem ischen S auersto ffb ed arf auf m anom etrischem W ege e rm itte lt. L etztg en an n te V er: fah ren sw eise s te llt nich t nur ein M a f r den oxidativen A bbau der organischen In h altss to ffe a u f m ikrobiologischem W ege dar, sondern l t aufgrund des entsprechenden K urvenveriaufes auch Aussagen ber die K inetik des A bbaues zu.
Trger des Hygiene-tnsttuts: Verein zur Bekmpfung derVlkskrannnenen im RuftrtoWengei eV, Gefeenkircften
1011 0 0 0 3 2 2
FIRE-HYGIENIC EXAMINATION (Brandhygienische Prfung) .
In your a.m. letter you invited us to do the fire hygienic examinations and assessment of the extinguishing agent called Light W ater FC-201 F. which is manufactured by your company.
The test report is intended to be presented to the registration office for extinguishing agents; ft is no assessment by means of fire engineering The product to be tested is a Are extinguishing agent f r w f on surfactants and alcohols; it shall be used as a foam.
le s t re n te
a i c o m p atibiuty o f -m s ex tinguishing agemt so lu tio n s w ith s m n and y es
To detect possible irritant effects of the extinguishing agent Light W ater FC- 201 F on skin and eyes, white rabbits were used for experiments. Diluted solutions of the product in concentrations of 1 and 10 weight percentage were applied to the sensitive inner skin of the ear and underneath one eyeOd of the animais.
The results of the experiments showed that no irritant effects could be detected on the skin treated with a/m solutions. Therefore, you can assume that skin irritations can be widely excluded during the use of the extinguishing agent The pH-vaiues of the solutions are of a magnitude of 8.1 to 8.4; in this range skin usually tolerates the solution without irritations.
The examination of irritant effects regarding the eyes showed that only the 10% solution caused minor reddening of the eye's mucous membrane on the first experimental day; the irritation ended the following day. The 1% test solution didn't cause any irritations.
b t COMPATIBILITY OF THE FOAMED EXTINGUISHING AGENT
The effect of the foam of the extinguishing agent Light W ater FC-201 F on skin was tested with a heavy (?) foam. This foam was produced by means of a 1% solution and with the help of a modified wet extinguisher. In the experiment guinea pigs (with the exception of theft1heads) were exposed to the foam for 10 minutes. Afterwards the foam was removed manually and the skin of the animals dried with warm air. These tests with the extinguishing agent Light W ater FC-201-F showed no negative effects on the animals. Apart from this result it has to be pointed out that inhalation of this kind of foam may lead to suffocation; It shouldn't be sprayed at people directly.
c) With regard to possible toxic effects of the fire extinguishing agent Light W ater FC-201 F on mpmmals toxicological tests were earned out for orientation with a collective of 15 whfte mice. The animals were kept on dried food and received a 1% solution of the mentioned extinguishing agent as the only drinking possibility. During the experimental time of 14 days and the subsequent observation interval of two weeks, no damages were detected in comparison to a group of control animals.
SUMMARY
______
On the basis of the known test results and the data given to us, there are no reservations against the planned use of the extinguishing agent Light Water FC-201 F from a fire hygienic point of view.
000323
HYGIENE-INSTITUT DES RUHRGEBIETS, GELSENKIRCHEN Institut Kg Umwelthygiene und Umweltmedizin
Blatt 2
Als B erechnungsgre im H inblick au f die A b b au rate diente d er nach der K alium *
dichrom atm ethode exp erim en tell fes tg e s te lite chem ische S au ersto ffb ed arf (C S 8 = 11 0 0 0 m g 0 2/l), d er als M a f r die vollstndige M ineralisation der organischen Substanz
des Produktes herangezogen w erden kan n . Z ie h t m an diesen W e rt als die f r den 1 0 0 % igen A bbau erfo rd erlich e S auerstoffm enge h eran, so b etrg t der biochem ische A b-,
bau, ausgedrckt als BS8 5 ( 6 2S 0 m g 0 2/I) 5 6 ,3 % , W ie der als A nlage b eigefgten gra
fischen D arstellung ber die au f m anom etrischem W eg e e rm itte lte biochem ische A bbakin etik entnom m en w erd en kann, is t die biochem ische O xidation nach einem Z eitrau m *. von 4 T agen bereits zu r H lfte abgeschlossen. D er Endpunkt des m ikrobiologischen A b baues der chem isch oxidierbaren In h altssto ffe ist unter den g ew h lten V ersuchsbe dingungen nach e tw a 2 4 T ag en erreich t und b etrg t 7 5 % . A ufgrund der vorliegenden D aten kann das P rodukt Light W a te r F C -201 F (1 % ig) als biologisch g u t abbaubar einge stu ft w erden.
2. V e rh a lte n g e g e n b e r n ie d e re n W a sse ro ra a n ism e n
Um praxisnahe A ussagen ber eine ggfl. vorliegende T o x iz it t des zu untersuchenden Produktes Light W a te r F C -201 F gegenber niederen W asserorganism en m achen zu
knnen, w urde ein T T C -T e s t m it einer 1 % igen Gebrauchslsung d u rch g ef h rt. Das V er
fahren beruht d arau f, d a die D ehydrogenasen der lebenden Z eilen (B elebtschlam m ) 2,3,5-T rip h en yltetra zo iiu m c h Io rid (TTC ) zu rotem Form azan in q u an titativer A bhngigkeit zu den jew eils aktiven Z eilen reduzieren. A u f diese W eise l t sich durch die m engen m ige Erfassung des g eb ild eten Form azans eine unm ittelb are A ussage ber die T o x izit t eines S to ffe s , den m an in eine d efin ierte B elebtschlam m /TTC -S uspension einbringt, m achen, w en n m an die Ergebnisse m it denen einer Parallelprobe verg le ic h t, die diesen S to ff nicht en th lt.
W ie die sem iiogarithm ische grafische Abbildung verd eu tlich t, lie g t die Form azanbfldung, in absoluten W erten au sg ed r ckt, zunchst ber dem B lin d w ert. D er w e ite re V e rla u f d t f _ Kurve belegt dann, d a m it zunehm enden A n teilen an 1 % ig er L ig h t-W ater F C -1 0 2 FLsung eine A bnahm e der Form azanbdung, die bei einer K o n zen tratio n von c a . 1 ,0 m l /
1 0 ml G esam tisung den B lin d w ert e rreich t, e in tritt. M en g en an teile von 8 m l an Pro
duktlsung fhren sch lie lich zur annhernden In a k tiv it t der lebenden Z ellen und zum w eitreichenden Erlschen d er D eh yd ro g en asen aktivitt.
000324
Trger des Hygiene-insntuts: Verein zur Bekmpfung der Voikskranknetten im Ruhrkoniengebiet e.V.. Geisenkirenen
-3"
HYGIENE-INSTITUT DES RUHRGEBIETS. GELSENKIRCHEN Institut fr Umw^ttnygitn und Umwaltmedlzjn
> .B latt 3
3 . V erh alten gegenber hheren W asserorqanism on
Oie berprfung d es P roduktes Light W a te r F C -201 F hinsichtlich fisch to xisch er Eigen* schften erfo lg te m it H ilfe des in der D IN 3 8 4 1 2 , T eil 2 0 beschriebenen V erfah ren s (Fischtest) an einer 1 % ig en G ebrauchslsung. Danach w urden 5 cm bis 7 cm lange Goldorfen (Leuciscus idus) in die aus v .g . Produkt und Verdnnungsw asser hergestellten Testlsungen ein g e s e tzt und das V erh alten d er Tiere 4 8 Stunden lang b eo b ach tet. ) W hrend der V ersu ch sd au er w u rd e die T em p eratu r des b el fteten T estw assers a u f 2 0 C 1 C g e h a lte n . A ls T esterg eb n is is t im vorliegenden Fall fe s tzu h a lte n , d a erst bei einer 20-fa c h e n Verdnnung der 1 % ig en T estfl ssig keit keine nachteiligen A us w irkungen a u f die ein g esetzten T iere m eh r zu erkennen w aren .
4 . Zusam m enfassung
Das Produkt Light W a te r F C -201 F s te llt eine organisch belastete Flssigkeit d ar, die dem biologischen A bbau g u t zugnglich is t.
Im H inblick au f die A b leitu n g des Produktes ber die K analisation in A bw asserreinigungs anlagen ist aufgrund d er Ergebnisse des T TC -V ersuches festzu stellen , da dann keine nachteiligen A u sw irku n g en a u f den biologisch arbeitenden T eil eines K lrw erkes zu er w arten sind, w en n s ich erg este llt is t, d a die 1 % ige Lschflssigkeit m it anderen W ssern, z.B . huslichen A b w ssern m indestens im V erhltnis 1 :1 0 verd n n t w ird . .
In V o rflu ter sollten W s s e r, die das P ro d u kt Light W a te r F C -201 F e n th a lte n , n ich t ab g eleitet w erd en , da sie aufgrund der hohen organischen Belastung so w ie der Fischtoxizi t t zur nachteiligen V ern d eru n g der W asserb esch affen h eit fhren w rd en .
ysassi Landesfeuerwehrschule NRW Am ti. Prfstelle fr Feuertschmittel u. -gert Telgte
Anlagen
D er D irekto r des In s titu ts r.A .
000325
Trger aas Hygiene-Instituts: Verein zur Bekmpfung der Volkskrankheuen kn RunrkohlengeOiei e.V.. Geisenkirenen
OQ0326
B E S ie O P Y AVAILABLE
Mg Form azan/m g S chlam m trockenm asse 15 14 13 12 11 10 9
8 7 6 5 4
**3'
2
1
T
31 0,1
Hyglene-lnslilul des Rutugebleis zuGelsenkirchen
Toxizittsbestimmung wit 2,3,5-Triphenyltetrazoliumchlorid(TTC) Firma: 3N Deutschland GmbH, Neues Produkt: Light Water FC-201 F (l%ig)
T"
- V'** '-''`Hi,'
TT
1,0 angewandte Henge/lOml
000327
, BEST-COPY AVAILABLE
} I
/
!#
^ `H ygiene-Institut
des Ruhrgebiets, Gelsenkirchen
| | Gelsenkirchen
Institut fOrUmwaanygiene und Umweitmedizin
DireWoc Prot. Or. mad. M ann Exner
BEST COPY AVAILABfcE-TL
V'iV ' ' "*. ! - i v;llyganatniwurPoatfacniQl.g4-S4Sai2G*atfar*rcran
:iu 3 M D eutschland G m bH C ari-S ch u rz-S tr. 1
4 1 4 5 3 Neuss
Rotmauser Strae 19 45879 Gelsenkirchen Telefon (0209) 1586-0 Telefon Durchwahl (0209) 1586- 1 7 4 /2 4 7 Telefax (0209) 1586- 251
45879 Gelsenkirchen. 13. September 1 9 i
D ir.Tgb.-N r. A 3471 E/93/C Sachbearbeiter. Tolksdorff/ W ei
B etr.:
Lschm ittei Light W a te r FC -201 F hier: Brandhygienische Prfung und B eurteilung
Bezug: Ih r Schreiben vom 2 9 .0 3 .1 9 9 3 , Z .: N M C P /R V -T H
Im Rahm en des v .g . Schreibens b eauftragten Sie uns m it der brandhygienischen Prfung und B eurteilung des von Ihnen hergestellten Lschm ittels m it der B ezeichnung L ig h t W ater FC -201 F.
D er hier zu erstellende Prfbericht ist nur zur V o rlag e bei den Zulassungssteilen f r F euerlschm ittel b estim m t und s te llt keine Beurteilung in brandtechnischer H in c h t d ar.
Bei dem zu r berprfung anstehenden Produkt h an d elt es sich um ein a u f der Basis von T ensiden und A lkoholen aufgebautes Feuerl sch m ittel, das als S ch au m zu m E n s a tz kom m en soll.
y&SSS^SiSSSSESS&SSS
a . H a u t-u n d A u aen vertro lichkeit von Lschm itteBsunoen
-
Z u r Erm ittlung der m glichen R eizw irkung des Lschm ittels L ig h t W a te r F C -2 0 1 F
gegenber der H au t und den A ugen sind w ei e Kaninchen zu V ersu ch szw e cken
herangezogen w o rd en . Im vorliegenden Fall w urden verdnnte Lsungen des Produk
te s m it K onzentrationen von 1 G e w .% und 10 G e w .% au f die als em pfindlich be
kannte O hrinhenhaut und unter ein A ugenlid der T iere a p p liziert.
' V "
.
000328
. ,r
Trger des Hygiene-JnsntuB: Vera zur Sekmofung derVoikakrankneiien im flutvkotenge&iei e.V, Geisenidrcften
-2 -
HYGlENE'INSTmjT DES RUHRGE3IETS, GELSENKIRCHEN
Institut (Or Umwetthygiene und Umweltmedizin
.fig ja p ) 1 ;
__________
Blatt 2 .':"*
A ls Ergebnis der durchgefhrten V ersu ch e is t festzu stellen , da bei den m it v .g .
Lsungen behandelten H autpartien keine R eizerscheinungen zu b eo b ach ten w a re n
. und som it davon ausgegangen w erden kan n , da beim E n s a tz des L sch m itteis Irri
tatio n en der H au t w eitgehend auszuschlieen sind. Die p H -W erte d er Lsungen be
w egen sich in einer Grenordnung von 8 .1 bis 8 ,4 und so m it in einem B ereich , der
von der H au t blicherw eise noch reizlos to le rie rt w ird .
j
)
D ie berprfung der Reizw irkung im H in b lick au f die A ugen erg ab , d a nur die *
1 0 % ige Testisung am ersten V ersu ch stag eine leich te Rtung d er A ugenschleim
hute hervorrief; die v .g . Irritation klang jedoch nach einem Tag ab . Die 1 % ig e
Testlsung lste keine Reizerscheinungen aus.
b . V ertrg lich keit des verschum ten Lschm rttels Die Reizw irkung des verschum ten Lschm ittels Light W a te r F C -201 F a u f die H aut
is t anhand eines Schw erschaum es u n tersu ch t w o rd en , der aus ein er 1 % ig en V er
dnnung m it H iife eines m odifizierten N alschers erzeu g t w u rd e. Im V ersu ch w urden M eerschw einchen m it A usnahm e des Kopfes 10 M in u ten lang v .g . Schaum ausgesetzt. Danach w urde der Schaum m anuell en tfe rn t und das Fell der T ie re in einem W arm luftstrom g etrocknet. N ach dem Ende der Versuche w aren bei den ein g esetzten Tieren keine nachteiligen A usw irkungen des zu untersuchenden Lsch schaum es Light W a te r F C -201 F fes ts te llb a r.
Unabhngig hiervon is t an dieser S teile jedoch darauf h in zu w eisen , d a die Inhalation von Schum en dieser A rt zum Ersticken fhren kann, und da M enschen n ic h t d irekt angesprht w erden sollten.
c . Im H inblick au f die sugetiertoxikologische W irkungsw eise des F eu erl sch m ittels
Light W a te r FC -201 F sind o rientierende, toxikologische U ntersuchungen an einem
K ollektiv von 15 w eien M usen d u rch g ef h rt w orden. D ie T iere w rd en bei
T ro cken fu tter gehalten und erhielten als ausschlieliche T rin km g lich keit eine 1 _____
% ige Lsung des genannten Lsch m ittels. A ls Ergebnis dieses V ersu ch es is t
festzu h alten , da w hrend der 1 4-tg ig en V ersuchszeit so w ie im
N achbeobachtungszeitraum von zw e i W o ch en gegenber einer G ruppe von
K ontrolltieren keine Schdigungen fe s ts te llb a r w aren .
000329
Trger aas Hygune-msotuts: Verein zur Bekmpfung der Volkskrankheuen im Runrkofflengefiiet e.V.. Getsenkirctwt
-3 -
Zusam m enfassung
A ufg ru n d d er vo rlieg en d en U ntersuchungsergebnisse und d er uns zur R ezeptur Ober lassenen D aten b esteh en gegen d ie g ep lan te V erw en d u n g des Lschm ittels Light W a te r F C -201 F aus brandhygienischer S ic h t keine Bedenken.
f
D er D irekto r des Institu ts i-A .
V e rta g Landesfeuerwehrschute NRW AmtL PrOfsteSe fr
FeueriSschmittel u. -gerate Telgte
V. 0 0 0 3 3 0
WM T r n a Hxnion irntttuae Verein zur Oeteimofunu der VofcstoanWioiten imRutwkohlengeoiet e.V:. Getsenkkcnen