Document 6bYez3g2ooVz5LoGXMp7Q5Jym
430
CHAPTER 23
1948 Guide
Table 2. Flow of Ste^& in Pipes
P = loss in pressure in pounds per square inch. D = inside diameter of pipe in inches.
L = length of pipe in feet. d = weight of 1 cii ft of steam. W - pounds of steam per hour.
_______ :
/ PdDt
W = 5220 -A/ /
3.6 \
1 + ."gr
''
P = 0.0000000367 ( 1 +
Pbbssurb
Loss
m Ounces
Col. 1
Pips Sub
s2wV^ Actual Nominal Internal Diameter
Internal Abba or
PlPB Sq Inches
Con. 2
.
f fl*
1 Col. 3
D Ava
B Steam
V'1 Press. rera.
Length
or.PiPB ' IN
Fbst
Col. 4
w-
0.25 ____6_54.2_8__1l 1__
0.50 92'28
1.049 1.380
0.864 1.496
0.536 -1.0 0.187 1.178 -0.5 0.190
20 40
1.00 130.5
m 1.610
2.036 1.828 0.0 0.193
60
2
184.6 2
2.067
3.356 3.710 0.3 0.195
80
3 226.0
2.469
4.788 6.109 1.3 0.201
100
4
261.0 | 3
3.068
7.393 11.183 2.3 0.207
120
5 291.8
3.548
9.887 16.705 5.3 0.223 140
6
319.7 \
4.026 12.730 23.631 10.3 0.2481 .160
7 345.3 - 4h 4.506 15.947 32.134 15.3 0.2701 180
.8
369.1 5
5.047 20.006 43.719 20.3 0.290 200
10
412.7 6
6.065 28.886 71.762 30.3 0.326 250
12 452.0 7 7.023 38.743 106.278 40.3 0.358 300
14
488.3 _| 8
7.981 . .50.027 149.382 50.3 0.3881 350
16
522.0 1 9
8.941 62.786 201.833 60.3 0'415| 400
20
583.6 I 10
10.020 78.854 272.592 75.3 0.452 1 450
24
639.3 12
12:000 113.098 437.503 100.3 0.507J 500
28 . 690.5 14 13.250 137.880. 566.693 125.3 0.557 600
32
738.2 16
15.250 182.655 816.872 150.3 0.603 700
40
825.4
Column 1 X 2X_ 3 X 4 -- lb of steam 175.3 0.645
800
48 904.1 pipe for a given condition.
200.3 0.6851 900
Exainple 1: l oz drop -- 2 in. pipe
80 1167.2 - 1.3 b press. -- 100 ft equivalent length:
1000
160
1650.7 !
130.5 X 3.710 X 0.201 X 1 - 97.2 lb per hour. 97.2 X 4b o 388.8 sq ft equivalent radiation.
1200
320 480
2334.5 2859.1
i Table 1 does not allow for entrained water in low-pressure 1 steam, condensation, in covered pipe and roughness in com-
mertial pipe as found in practice.
1500
2000
2.240 1.580 1.290
1.120
1.000 0.912 0.841 0.793 0.741 0.710 0.632 0.578 0.538 0.500 0.477 0.447 0.407 0.378 0.354 0.333 0.316 0'289 0.258 0.224
Pounds per square inch gage -- 2.04 in. Vacuum, Mercury Column. *>The factor 4 is the'approximate equivalent in square feet of steam radiation of 1 lb of steam per hour.
Steam Heating Systems and piping*
431
Maximum Velocity
The capacity of a steam pipe in any part, of a steam system depends upon the quantity of condensate present, the direction in which the condensate is flowing, and the pressure drop in the pipe. Where the quantity of condensate is limited and is flowing in the same direction as the steam,, only the pressure drop need be considered. When the con densate must flow against the steam, even in limited quantity, the ve locity of the steam must not exceed limits above which the disturbance between the steam and the counter-flowing water may produce object ionable sounds, such as water hammer, or may result in the retention of water in certain parts of the system until the steam flow is reduced sufficiently to permit the water to pass. The velocity at which such disturbances take place is a function of (1) the pipe size, whether the pipe
Table 3.
Comparative Capacity of Steam Lines at Various Pitches for Steam and Condensate Flowing in Opposite Directions
Pitch of Pipe in Inches per 10 Ft. Velocity in Ft per Sec.
Pitch of PlPB
X IN.
X in.
1 IN.
l^IN. :2in.
3 IN.
4 IN,
5 IN.
Capacity Capacity M ax. Vel. Capacity M ax. Vel. j C apacity, Max. Vel. Capacity M ax. Vel. Capacity
1'
M ax. Vel. Capacity Max. Vel. Capacity M ax. Vel.
Pipe
Size Inches
:>
1
2
Capacity Expressed in Square Feet E D R
X 25.0 12 30.3 14 37.3 18 40.4 19 42.5 20 46.1 21 47.5 22 49.3 23
1
imx
45.8 12 52.6 15 63.0 .17 70.0 20 75.2 22. 83.0 23 87.9 25 90.2 26 104.9 18 117.2 20 133.0 23 144.5 25 154.0 27 165.0 28 172.6 29 178.2 31 142.6 18 159.0 21 181.0 23 196.5 25 209.3 27 224.0 28 234.8 30 242.6 31
2 236.0 19 263.5 20 299.5 23 325.5 25 346.5 27 371.5 28 388.4 29 401.1 30
Capacity Expressed in Pounds per Hour
X 6.3 12 7.6 14 9.3 18 10.1 19 10.6 20 11.5 21 11.9 22 12.3 23
1 11.5 12 13.2 15 15.8 17 17.5 20 18.8 22 20.8 23 22.0 25 22.6 26
ix 26.2 18 29.3 20 33.3 23 36.1 25 38.5 27 41.3 28 43.2 29 44.6 31 ix 35.7 18 39.8 21 45.3 23 49.1 25 52.3 27 56.0 28 58.7 30 60.7 31 2 59.0 19 65.9 20 74.9 23 81.4 25 86.6 27 92.4 28 97.1 29 100.3 30
.Data from American Society op Heating and Ventilating Engineers Research Laboratory.
runs horizontally or vertically, (2) the pitch of the pipe if it runs hori zontally, (3) the quantity of condensate flowing against the steam, and (4) freedom of the piping from water pockets which under certain con ditions act as a restriction in pipe size. .
Reaming Important
Three factors of uncertainty always exist in determining the capacity
of. any steam pipe. The first is variation in manufacture, which appar
ently cannot be avoided. The second is the care used in reaming the ends
of the pipe after cutting. The effect of both of these factors increases as the
pipe size decreases. According to A.S.H.V.E. Research Laboratory tests,
either of these factors may. affect the capacity of a 1-in. pipe as much as
20 per cent. The third factor is the .uniformity in grading the pipe line.
All of the capacity tables given in this chapter include a factor of safety.
However, the factor of safety referred to does not cover abnormal defects
orconstrictions nor does it cover pipe not properly reamed.
-.