Document 6bYBExka5rx5gkgOjaZGYXGO4

A Gas Chromatographic-mass Spectrometric Comparison of Polychlorinated Biphenyl Residues in the Japanese Quail Brain to an Aroclor Standard by D. J. Calc, Y. A. GnMCHUS,*n<l J. J. Worm an Kxireeiment Sifition ftiorhemtrtry anti Chemistry Department* Snttift Dakota State Univerxiiy, Hrottk ing* S700A Polychlorinated biphenyl (PCB) residues have been discovered in biological tissues in recent years (BAGLEY et al., 1970; OREICHUS et. &l., J973a; KOEMAN et al. , 1969). PCB storage in liver, brain, and muscle has been reported (DAHLGREN et al.. 1971). Analyses of biological residues by combined gas-liquid chromatography (GLC) and mass spectrometry (MS) revealed their patterns to most closely resemble those of two PCB standards, Aroclors 1264 and 1260 (BAGLEY et al. . 1070; GREICHUS et al. , 1973b). However, the biological residue chromatograms had certain changes in their overall patterns as compared to the standards. This study was designed to (1) compare the residue patterns in brains of quail fed Aroclor 1260 to the Aroclor 1260 standard, (2) identify the residue components by mass spectrometry, and (3) determine the specific changes in the biological samples. MATERIALS AND METHODS Seven Japanese quail (Coturnlx coturnlx laoonlca) 7 weeks of age were fed 1,000 parts per million (ppm) Aroclor 1260 for 21 days or until death. Aroolor 1260 was supplied by Monsanto Chem ical Company, St. Louis, Missouri. It was dissolved In soybean salad oil and thoroughly mixed into the diet of Purina Game Bird Chow. Four of the 7 birds died from this treatment, with deaths occurring as early as day 12 of the treatment. The remaining birds were sacrificed on day 22. The heads of all birds were fvoxen for later brain residue analyses. il Brains were removed and wet weights taken on a Mettler bal ance. Whole brains were homogenized and dried in a Florlsilodlum sulfate mixture. Procedures for extraction, purification and quantitation of PCB's were essentially those of GKEICHUS et al. (1973a). PCB's were extracted with 750 ml of 70:30 (v:v) petroleum ether and dichloromethane on a 20 by 600 mm Pyrex f Approved for publication by tho Director of the S. D. Agricultural Experiment Station as paper No. 1195 of the Journal series. 333 uB.iiun A TiMlralogy. Vri*f Nf* York Inr. MQNS 082077 . - ? ft i V;' ' v? ' : -* :r!-. .. i. chromatographic column packed with 50 grama of Florisil. fiO/inn mash (Fisher Scientific Co.). GLC analyses were performed on a Varian Aerograph HY-FI Model 600 D gas chromatograph with an 8 me 3Ni detector. A borosllicste glass column, 1/8 inch o.d. x 5 feet in length, was packed with a 1:1 mixture of 15% QF-1 Silicone (Fluoro) and 10% DC-200 Silicone on 80/100 mesh Chromosorb W (H/P A.W. DMCS). The nitro gen carrier gas was operated at a flow rate of 40 ml/min, and the operating temperatures for Injector, column, and detector were 210 C, 190 C, and 280 C, respectively. The PCB's in the standard and brain were identified by GC/MS. The appropriate m/e values of the molecular ions were observed to determine the number of chlorines contained in the PCB's. Chlorine numbers were verified by the relative Intensities of the peaks in the molecular Ion clusters. Brain extracts were pooled for MS an alysis. The instrument used was a Flnnlgan Model 3000 Peak Iden tifier GLC/MS equipped with a Gohlke separator. A 1/8 Inch i.d. x 5 foot boroslllcate glass column was packed with 3% 0V-1 on 60/ 80 mesh Gas Chrom Q with a helium carrier gas flow rate of 40 ml/ min. Temperatures of the column, injector, and accessory were 200 C, 210 C, and 210 C, respectively; and the ionization poten tial was 70 ev. Statistical treatment of the peak area percents for peaks of similar retention times in the standard and brain chromatograms consisted of the t-test for paired and unpaired data as appropri ate (STEEL and TORRIE, 1960). RESULTS AND DISCUSSION Comparison of the quail brain chromatograms with the Aroclor 1260 standard chromatograms revealed some gross changes In the pat terns. Representative chromatograms are ahown in Figure 1. Quail brain peaks with relative retention times (rrt's) of about 72, 84, 122, and 160 were significantly smaller (p<0.01) than the corre sponding standard peaks (Table 1). There were no peaks at rrt's of 46, 100, 113, or 228 In the biological samples. New peaks oc curred in the brains at the rrt of 238, and occasionally at 108. Brain peaks were larger (p<0.01) at rrt's of about 147, 176, 107, 280, and 336 than the corresponding standard peaks (Table 1). BAILEY and BUNYAN (1072) found that pigeons (Columbia llyla) and Japanese quail metabolized PCB's at a rate generally dependent on the amount of chlorine in the molecule. They suggested that some lower chlorinated isomers are metabolized very rapidly. Many 334 M0NS 08207a of the peaks representing lower chlorinated compounds disappeared from the tissue of Japanese quail fed PCB's (KOEMAN et, al.., 1969), and In the eggs of mallards(Anas platyrhynchoa) fed Aroclor 1254 (HEATH et al. , 1972). Considerable diminution of the first two major chromatogram peaks occurred In tissue samples, eggs and feces of ring doves (Slrgp.tojella riaorlq) fed 10 ppm Aroclor 1254 (L1NCER end PEAKALL, 1973). Rats administered Aroclor 1254 metabolised the shorter retention time components to a greater ex tent than the longer retention time components (GRANT et al., 1971). Figure 1. GLC tracings of the brain residues In Japanese quail fed 1000 ppm Aroclor 1260 and the Aroclor 1260 etandard. Average retention times (p.p'-DDE - 100) are given above the component peaks. Conditions: 1/8" o.d. x 5* glass column with 1:1 mixture of 15X QF-1 and 10% DC-200 on 80/100 mesh Chromosorb W operated at 200 C with a nitrogen gas flow rate of 40 ml/min. 336 /'---La .vA * r-er*.*1- Comparative GLC and mass spectral data for the components of Aroclor 1260 standard and Aroclor 3260 brain residues in Japanese quail. Aroclor 1260 Standard Quail Brain Peak Cl Area rrt1 m/e no. % 46 290 4 -- Nanogran %s -- Response factor3 -- Peak rrt -- _m/e Cl Area _ _no . % Nanogram %_ 70 324 5 82 324 5 100 324 5 2.8 3.6 2.6 2.7 4.7 3.8 0.0009 0.0012 0.0015 72 __ 84 324 __ 0.1** 5 1.8** 0.1 2.2 358 6 113 358 6 7.8 122 358 6 6.6 147 358 6 11.6 160 392 7 3.9 177 359 6 10,2 197 392 7 6.0 228 358 6 3.3 12.3 14.1 4.9 12.4 9.3 0.0004 0.0018 0.0012 0.0012 0.0012 0.0015 108 122 147 160 176 197 -- 358 358 -- -- 392 ~ 0.1 6 0.3** 6 17.1** -- 0.3** -- 17.0** 7 10.8** 0.7 24.4 0.4 24.1 19.2 392 7 8.7 9.8 0.0011 238 2.7 282 392 7 17.5 426 8 11.0 0.0006 280 392 426 7 27.8** 8 341 392 7 11.3 4.2 0.0003 336 392 7 16.4** 364 426 8 7.4 4.0 0.0005 366 426 8 5.9 ^ Retention tines relative to p,p'-DDE=lOQ as measured front first appearance of solvent peak. 19.7 5.8 3.5 *- fercent of total quantity of standard injected into gas chromatograph as taker, from WBB and MC Call 11972). 3 Detector responses (ng PCD/area) to the standard components. `'Significantly different from the standard at the pcO.Ol level. Loss of a peok at tha rrt of 228 was observed in wild cor morant (PlmJacrocorax auritus) carcasses and eggs, and in wild pollcan (Pelecanus erythrorhynchoa) fat (GHElCHUS et al.. 1973b). A peak appeared in cormorant carcasses at rrt 237 and in pelican fat at 234, which does not correspond to any peak In either Aroclor 1294 or 1260. This may correlate with the new peak at rrt 238 In the quail brain of this experiment. The more highly chlorinated compounds have longer retention times (Table 1). The relatively larger size of the peaks with longer retention times In brain tissue would Indicate that these more highly chlorinated compounds were preferentially stored in the brain lipids over the less chlorinated compounds, and/or were less readily metabolized. WEIU) and MC CALL (1972) determined the nanogram percent of PCB in each CC peak by combined CC-MS analysis and analysis by GC with a Coulson electrolytic conductivity detector. This allowed tho determination of the empirical formulae for the compounds and tho absolute amount of chlorine repreaented by each peak. Mean response factors (ng PCU/area) for each peak were determined in the present experiment by analysing known amounts of 7 standard# and measuring the peak areas. Brain samples were chromatographed end peek areas were multiplied by the corresponding response fac tors, giving the PCB nanogram quantities for the peaks in the brain. Comparison of the nanogram percentages of the standard peaks with the peaks in the brain revealed the same trends as compari son of the peak area percentages (Table 1). The nanogram percentague for peeks et rrt's of about 72, 84, 122, and 160 were smaller in the brains than In the standards, and the nenogram percentages for peaks at rrt's of 147, 176, 197, 280, and 336 were relatively larger In the brain. However, the differences in peak area per centages and nanogram percentages from standard to brain were not in close agreement for most peaks, indicating the Importance of determining detector response to the various components. Others havo stated the importance of this (ROTE and MURPHY, 1971; WEBB and MC CALL, 1972). Nanogram quantities were not determined for the peaks in quail brain at rrt's 108 and 238, as there were no corresponding standard peaks for determination of the necessary response fac tors. As a result, the remaining brain nanogram percent values are slightly higher than if these peek values had been included. 337 hONS The results of this experiment Showed that qualitative and quantitative changes in the Aroclor 1260 standard occurred with in the bodies of the quail, and tre lens chlorinated compounds In comparison to the more highly chlorinated compounds were stored In relatively smaller quantities In the brain and/or were more readily metabolized. ACKNOWLEDGMENTS The authors thank Lauren Poppen and Barbara Ammann for tech nical assistance, and the Society of the Sigma Xi for the grant-inaid-of-research. Oklahoma Panhandle State College kindly pro vided facilities for the housing of the quail. LITERATURE CITED SAGLEY, G. E., W. L. REJCHEL, and E. CROMAKTIE. J. Assoc. Offic.. Chen. 32. 251 (i7t>). BAXLEY, S. and P. J. BUNYAN. Nature 238, 34 (1972). DAHLGREN, ft. B. , Y. A. GREICHUS, and U. L. LINDER. J. Wlldl. Mgmt. 35, 823 (1971). ANT, D. L., W. E. J. PHILLIPS, and D. C. VILLENEUVE. Bui. En viron. Contain. Toxicol. 6, 102 (1971). GREICHUS. Y. A., A. GREICHUS, and R. J. EMERICX. Bui. Environ. Contain. Toxicol. 9, In Press (1973a). GRS1CHUS, Y. A., J. J. WORMAN, M. A. PEARSON, and D. J. CALL. Bui. Environ, Contarn. Toxicol. In Press (1973b). HEATH, R. G., J. W. SPANN, J. F. KREXTZER, and C. VANCE. Pro ceedings XV International Ornithological Congress, 475 (1972). KOENAN, J. K., M. C. TEN KOEVER DE BRAUW, and R. H. DE VOS. Nature 221., 1126 (1969). LINCER, J. L. and D. B. PEAKALL. Environ. Pollut. 4, 59 (1973). ROTE, J. W. and P. G. MURPHY. Bui. Environ. Contam. Toxicol. 6, 377 (1971). STEEL, R. G. D. and J. H. TORRIE. Principles and procedures of statistics. New York: Me Graw-Hlll (I960). WEBB, R. G. and A. C. MC CALL. 164th Natl. Meeting A.C.S., Symposium on PCB's, New York, N. Y. August 28 - Sept. 1 (1972). 338 *QNS oaio82