Document 6bXyw3Kb6Np2vx68bYkdRzE33
Keeping PCB's Out of the Environment
-- a status report on what we've done, what we're doing, what we will do
HONS 047691 Wm. G. Krummrich plant Sauget, Illinois October, 1972
TOWOLDMONOQ47502
2. Steps to eliminate losses of PCB's
------------ Past Efforts ------------
We have spent $170, 000 to modify equipment in the manufacturing department. Programs include the following:
Installing settling basins and directing all flow to these basins by improved paving, curbing, and sloping. In the manufacturing area, drainage is directed to trenches and piping, and then to one of two 3,000-gallon settling basins. This insures PCB contain ment in case of accidental spill or equipment failure. The heavier, virtually insoluble PCB's will settle to the bottom of the basin, are later pumped into drums, and eventually incinerated.
In the incinerator area, drainage is directed to trenches and piping which flow into a 10,000gallon basin. Recovered PCB's are periodically pumped to storage, and later incinerated.
Rerouting of rupture disc lines and atmospheric vents through catch tanks, or redirecting them to settling basins. This insures that if a rupture does occur, PCB's will not get into the environ ment, but will be contained in a controlled area.
Providing nitrogen blanketing on storage tanks to eliminate any "breathing" of the tanks and result ant PCB escape.
Installing mist eliminators in vapor lines - once again to eliminate the possibility of PCB's leaving the manufacturing area through these lines.
Replacing underground sewers with above-ground sewers, and repairing or combining others, so that we can have accurate monitoring of the effluent from the department. In addition, this will prevent any unknown buildup of PCB's in our sewer systems or any contamination of PCB's into other sewers.
MONS 0*7695
2. Steps to eliminate lotto of PCB'i (continued)
In the plant, we have replaced all PCB fluidt in Therminol unltt and hydraulic tyatema with non-PCB fluidt. Cost of this program wat $80, 000.
-- Exttnsiva Education/Houtalcaaping Effort --
We have conducted an extensive education program with our operating personnel to emphasise - and re-emphasize - the need for control and containment of PCB't within the department.
Much of the success of our efforts depends on maintaining a high housekeeping level In the department. Below it a listing of the kinds of housekeeping responsibilities our operators have assumed:
All pumps are checked for leakage on every shift. Drip pans that collect leaks are emptied Into scrap Aroclor drums.
9 All leaks are reported and documented so that corrections can be made and settling basins observed.
* # "Floor Dry" is used to absorb any liquid Aroclor that has spilled or leaked. If it becomes necessary to flush PCB's to the settling basin, a minimum amount of water is used.
t Sampling drums and scrap*Aroclor drums are quickly palletized, labeled, and trans ferred to the incineration area.
HONS Q<* 7696
2. Steps to eliminate losses of PCB's (continued)
------------ Futur* Plans ------------
As a result of past programs and present efforts, our operations take place in essentially closed equipment, run by personnel following specific operating instruc tions. Key operating controls are monitored and recorded. All product transfers are within closed piping systems.
We believe that PCB losses from the operating department can be controlled to meet the expected EPA guideline as stated in the "Polychlorinated Bi phenyls and the Environment" report of May 1972 by the Interdepartmental Task Force on PCB'i. Average values will consistently be below 0.01 ppb as calcu lated in the receiving water."
t
HONS 0^7697 TOWOLDMONOQ47505
7
.3 Us of sophisticated systems to monitor our effluent
- Past Difficulties------------
Monitoring effluent streams for PCB's ic not an ea*y effort. PCB measurement can be changed dramatically -
by taking the sample at different places along the sewer main,
by changing the level at which the sample is taken (top, middle, bottom of sewer line or box),
by changing the speed at which the sample is taken,
by the varying velocity of the effluent.
Through exhaustive study, we feel we have installed the best sampling facilities and flow instrumentation, so we can continuously and accurately sample the stream and determine any PCB content in it.
In addition, to analyte the stream samples, we have purchased laboratory equipment which enables us to determine PCB content in the parts-per-billion range.
---- Prstnt Monitoring Program---------
Process waters from the Aroclor manufacturing de partment, as well as any overflow from one of the settling basins, enter the plant sewer system at one point. (Plans are to direct overflow from the other settling basin to this same point.)
The stream (200 to 300 GPM) passes through a Parshall flume, where instruments measure the quantity. A continuous sample of department effluent is taken at the flume. These samples are analyzed twice a week, and losses are calculated (in terms of concentration in the receiving water, the Mississippi River) from the flow measurements and laboratory analyses.
The Technical Services Department and department supervision review loss data to determine if corrective action is needed.
A similar procedure is followed to measure effluent from the incinerator area.
TOWOLDMON0047506
HONS G W 69U
4. Loading and Shipping Safeguards
8
-- -- In tht plant ------------
During loading operation*, we follow very specific operating procedures, based on very specific written instructions, to prevent accidental spills. The same is true for filling drums.
All loading and drum-filling operations take place in areas where drains and sewer systems are connected to settling basins.
------------ Aroclor in transit -------------
For additional insurance, we have substituted a safer drum for shipping Aroclors. The metal thickness was increased by 26% (18-gauge drum to 16-gauge drum), and double chimes were added to give strength to the heads.
In addition, we have added specific instructions to our Aroclor labels, as follows:
"This product contains polychlorinated bi phenyls, which some studies have shown may be persistent, an environmental contaminant and, possibly, injurious to certain forms of bird, aquatic and animal life. Extreme care should be taken to prevent any entry into the environment through spills, leakage, use, disposal, vaporisation or otherwise. "
"WASTE DISPOSAL Used plychlorinated biphenyl fluids may be returned freight prepaid for proper incineration at 3? per pound. Ship to: Supervisor, Dept. A-246, MONSANTO COMPANY. SAUCET, ILLINOIS 62201"
HONS 0H7699
4. Loading and Shipping Safeguard! (continued)
"ATTENTION - DO NOT USE IN ANY SYSTEM INVOLVING PROCESSING OR HANDLING OF: Food or food-related product*; Food wrapping or container material*; Pharmaceutical* or animal feed *tuff. ANY CONTACT MAY CON TAMINATE THESE ITEMS TO THE EXTENT THEY MUST BE DESTROYED. "
'IN CASE OF LEAK OR SPILL, CALL COLLECT 618-271-5835. "
9
HONS Q<*7700 TOWOLDMONOQ47508
5. Safe disposal of ased PCB's
We can now dispose of liquid-waate Aroclors
# assuming the organic aolvent in which the Aroclora are contained ia "incinerable", and
0 which are delivered to ua properly in tank cara, tank trucks, or druma.
Thia ia accompliahed through incineration at 2000+F. Coat of the incinerator waa $790,000.
An inatallation permit haa been received from the Illinoia EPA for this Aroclor incinerator. The unit meets all requirements specified by the EPA.
10
HONS 0*7701 TOWOLDMONOQ47509
II
CONCLUSION
r
We feel we have a dynamic program to keep PCB'
from the environment - one which haa produced
excellent rcaulta.
*
We are reducing diachargea to the loweat technically achievable level - and will continue to do ao.
The expected EPA guideline would reatrict PCB loaaca to an amount leaa than 0.01 ppb in the receiving water. We are conaiatently meeting thia expected EPA guideline aa atated in the "Polychlor inated Biphenyla and the Environment" report of May 1972 by the Interdepartmental Taak Force on PCB'a. All our efforta arc directed toward continuing to meet the guideline.
Thia, we feel, ia proof of our aincerity and effectiveneaa in the effort to control loaaea of PCB'a in the environment.
V. J
mqhs o'*1702
TOWOLDMONOQ47510