666 CHAPTER 40 1965 Guide Arid Data Book cooling tie liquid ammonia from the condenser with the cool refrigerant vapor from the evaporator. This increases the' re^ frigerating capacity of each pound of refrigerant at ho cost except' that of slightly warmer cooling water leaving the absorber. Not. all the auxiliaries described are used in every application. Consideration must be given to the efficiency improvement vs cost of auxiliaries. There is a combination which will yield the best economic balance of initial costs to operating expenses. , The arrangement of components in a 3-ton direct-fired,'air cooled water' chiller is shown schematically in Fig. 9. Influence of Condenser Temperatures Analysis of the ammonia-water cycle shows that unit effi ciency improves with a reduction in the condenser tempera ture. A fuller discussion of this point appears in the previous section on lithium bromide-water cycle absorption units.' Fig. 10 shows the performance of an ammonia-water cycle unit. ,- ., perature of the heat source is used here to control the output of the unit. A discussion of this may.be found in the previous section on the lithium bromide-water cycle.- BASIC ABSORPTION EQUIPMENT The components of absorption systems are, in effect, sta tionary heat exchangers; the only moving parts on such units may be the solution, refrigerant, and chilled water pumps.' These basic components may be arranged into a number of shells, depending upon the requirements of the situation. Units are available having one or more RheH3'fl.nH imT4K<>ry vessels.' '- Evaporators and Coolers .] Evapdratore perform'the'same function'ind in a RimiW manner in an absorption unit as they do1 in's' compression ' unit: they transfer heat from the material to becooled (water'r air,- or brine) to the refrigerant There' are two basic types of evaporators: dry and flooded. In the'dry evaporator the re frigerant is completely vaporized as it passes through; in the flooded evaporator only a portion of the refrigerant is evapo rated. A stirgetank is required to separate the vapor from the liquid. The liquid is returned to . the evaporator, while the vapor continues on in the cycle. In an absorption unit the absorber attracts only refrigerant vapor, in effect, operating the evaporator as a dry evaporator. If an abnormalcondition' should cause-liquid refrigerant to be carried over to the ab sorber, no physical harm would be done;'the unit capacity would be reduced temporarily until the absorber, solution could be restored.to the proper concentration. It makes no difference to. the operation-of the evaporator whether the refrigerant is inside or outside"the coil. The evaporator and the cooler are one and'the same conn ponenti.The beat required to evaporate,the refrigerant is ob tained by cooling the material on the other side'of the coil or (ube.^Coolers used with absorption units may be used as: (1) direct air coolers, and (2)' water chillers. i;.Atr coolers'. When direct air cooling is utilized, the refriger ant is' inside the coil and the air passes over the coiL Cooling and dehumidification are a function of the coil geometry and the tem peratures of the air and coil. The coil surface may be smooth or finned. Smooth-surfaced coils require greater surface than the. Influence of Chilled Water Temperatures Further analysis of die ammonia-water cycle shows the ad vantage of maintaining the chilled water temperature as high* as the load will permit. The previous section on the lithium bromide cycle includes an appropriate discussion. Chilled water temperatures suitable for any air-conditioning application" are available from ammonia-water cycle units. (See Fig. 10.)' _ T ............ By extending the pressure through which the,cycle operates the ammoniac-water cycle may be, used to produce, veryjow temperatures (--50 F) for industrial and process applications. This .low temperature system is sometimes used as aham- monia recovery unit in chemical proces work. Influence of Temperature of the Heat Source. The smaller sizes of ammonia-watercycle absorption-equip ment in use are' operated on-off. The temperature of;the heat source is immaterial in this type of operation; the unit merely runs a greater or lesser portion of the time, depending upon the load. Direct firing is ideal for applications of-thin type; generally used in residences. - - -- . ; Low temperature ammonia-water cycle equipment for'iri^ dustrial work, generally use waste heat - (steara)ivThe; tem^' Fig. 10... . Performance Oiaracteristks'of an"Ammonia' Water Cycle-Water Chiller * 1 h - Absorption Air-Conditioning ana Refrigeration Equipment gooed coil. The finned coil causes a greater pressure drop. .The fins' in addition, must be placed far enough apart to prevent re tention of moisture which is condensed from the air. *2. Water chiller. When the machine is designed as' a water chiller the refrigerant-is outside the coil, ana the water to be chilled is the coil. The coil may be submerged in . the refrigerant or the refrigerant may be sprayed over the coils in a thin fihn A system dulled water pump, separate from the ab sorption machine, is required to circulate the chilled water through the evaporator coils, and thence to the remainder of the air conditioning system. `'M 667 Condensers Condensers for liquefying the refrigerant are of three types: (1) aircooled, (2) water-cooled, and (3) evaporative! These three categories are identical to those used in other refrigeration systems. , 1. Air-cooled. Air-cooled condensers first became popular, on self-contained room air conditioners; and they are now used exclusively on this type of equipment.. t - The conventional air-cooled condenser is a fin-tube coil across which a fan blows air. The hot refrigerant from the generator enters the coil at the top, is condensed, and Sows to a receiver or accumulator. Air-cooled condensers require a well ventilated,' unobstructed location to obtain a constant supply of ambient The principal advantages of air-cooled condensers are. sim plicity, and low operating and maintenance coats.' 2. Water-cooled. Where an adequate supply of suitable water is available and its cost is not prohibitive, and where there are no log*! restrictions against its use, the water-cooled condenser, is preferred because of its superior performance. The tempera tures of ground water and city water are, in general, too low to be used directly with absorption equipment since manufacturers' specify minimum entering condenser water temperatures. Cooling water from the condenser discharge may be blended with the incoming water to maintain the water temperature to the, absorber above the specified minimum. l" . An increased recognition of the growing water shortage in the United States has led to increased restrictions on'the use of city'' water for air conditioning and refrigeration purposes. As a result, cooling towers are in almost universal use,-with water.cooled condensers. Absorption air conditioning equipment has. twice the heat rejection of compression type equipment, but does hot require a tower twice as big. A greater temperature rise in the condenser water temperature is economically feasible in absorption air-conditioning unite. The attendant higher temperature of the water entering the tower results in a higher heat dissipation rate for a given tower. ' The temperature of cooling water leaving the tower is a direct function of wethulb temperature. Because the maximum load on the system may coincide with maximum wet-bulb tempera tures, the air conditioning unit may, at such times, operate under adverse conditions, with a reduced efficiency.-In many areas, this combination of adverse conditions occurs for only about 5 per cent of the entire cooling period, and can be disregarded as an important factor in establishing yearly operating costa. Cooling .towers are more completely discussed in Chapter '46. -1 3. Evaporative. The evaporative condenser, provides'another n^DS of conserving water. It is, in effect, a combined condenser aud cooling tower in a single unit. A fan draws air across the conr denser coil which is kept wet by a water spray. .... The evaporative condenser requires a well ventilated, unob structed location to obtain a constant supply of air. Its perform ance characteristics are similar to those of cooling towers. Chapter 42 contains additional information on evaporative condensers. Absorbers The absorber is a-surface contact vessel where the refriger ant vapor can come into contact with, and be absorbed by, the concentrated absorbent. Heat is released in the'procesp, and cooling coils are placed in the absorber to remove thi neat of solution. Absorbers are of two types: (1) submerged coils, where the cooling coils are submerged in the maaa of. absorbent, or (2) spray or film distribution, where the absorbent solution is distributed over the cooling coils in a thin film or Rg. 11 .... Steam Supply Piping spray. The diluted absorbent collects in the absorber sump. In small units, gravity .circulates: this dilute solution to the generator; in-large units, a solution pump is used. ' " Generators . f Generators are heat exchangers using the heat to boil the refrigerant out'of'the dilute solution, to re-concentrate it. Generators may be of two-types:'directly or indirectly heated. Directly heated, generators burn fuel within the unit to pro duce the required heat; the flue gases pass through tubes in the generator .to boil the dilute solution.' Indirectly heated generators use steam, hot water, or hot gases to boil the solu tion. The'steam or hot water may be waste from other proc esses, or it may be produced in a companion low pressure boiler. r The'generator may be designed to operate with sub merged coils or tubes or with spray or'film distribution, just as does the absorber. When the generator is directly heated, provision must'be made for gas and flue connections. If the unit is installed indoors, provisions, must also be made for combustion'air. Refer to ASA Standard Z2l .30-1964, Installation ofGas Appli ances and Gas Piping. ` ' ' ' When the generator is indirectly heated, the supply piping, steam or water, should be .designed in accordance with good piping practice. When steam supply pressure is above 12 psig, a pressure reducing station suitable for' dead-end service should be installed. 'Fig. ' 11 shows' an arrangement of !the fittings generally'used on a steam supply line; in addition, a second steam trap should be placed in the condensate Tine from the condenser. In' high' temperature water applications, the water flow control valve may be installed either at the inlet or outlet of the generator. Control of Generator and Absorber Smaller unitary machines, which are direct fired, meet load variations through on-off operation or by step-input through self-contained water temperature controls. As design chilled water temperature is approached, automatic gas con trols' switch to lowered input settings to match capacity. Large machines meet load variations by varying the'rate of reconcentration of absorbent solution. A thermostat located . in the chilled water line leaving the evaporator senses' load changes' through changes in the water temperature. This thermostat controls'either: (1) anautomatic steam valve that varies steam flow'to the generator,-(2)'an automatic solution valve that varies the rate of flow of dilute :sohition to;;the generator, or (3) the rate of flow of dilute,'sbliiti6a"fo the generator and an automatic steam valve.-When'll decrease in load causes a drop'in the.leaving chilled water temperature: