DIRECTIONS FOR TEST NO. 14-25-52
SUBJECT: POUT Point Of ATOClorS________
METHOD: ASTM D97-30 * Cloud and Pour Point
ASTM Definition
"The pour point of a petroleum oil la the lowest temperature at which the oil Till pour or flow when It la chilled without disturbance under definite prescribed con ditional " The method of teat below follows ASTK directions exactly except that observations are made at intervals of 2?C instead of 5F and results are reported on Centigrade scale*
Apparatus
A skatoh of the assembled apparatus Is attached* R>r details of apparatus see ASTM D97~3
Procedure
Pour the Aroclor Into the clean dry test Jar to a height of 2 to 2-1/4" Insert oork carrying the test j thermometer and adjust so that the thermouse ter Is In the center of the test jar end the beginning of the capillary is 1/8" below the surface of the Aroclor* warm without stirring to a temperature of tfiPC in a bath at 4^C* Cool
to 30C In an air or water bath*
. Adjust temperature of the cooling bath so that
It is 8 to loc below the expected pour point of the Aroclor
and maintain In this range throughout the test* Place disk (e) In bottom of jacket and Insert test jar (with the ring gasket, f, 1 Inch above the bottom) Into the jacket. Disk, gasket and Inside of jacket must be dean and dry*
Beginning at a temperature 10C before the ex pected pour point, at each teat thermometer reading which Is an even number, carefully remove test Jar and tilt just enoug to ascertain whether there is a movement of the Aroclor In the teat jar* The complete operation of removal end replace
ment should not require more than 3 seconds*
If the sample has not ceased to flow when its temperature has reached 8C, place the test Jar direotly In a cooling bath of suitable temperature* As soon as the sample in the test jar does not flow when the jar Is tilted,
hold the test jar in a horizontal position for exactly 5
seconds as measured by a stop watch* If oil shows movement, replace test jar in cooling medium and repeat test at the
next temperature 2c lower*
DSW 330760
7/
STLCOPCB4077404
DIRECTIONS FOR TEST NO. SUBJECT; Fcrar Point Of Aroolora________________
METHOD:
E>97~]>0 Cloud and Four Point
Sheet Ho, t
Continue testing in this manner until a point is reaohed at which the sample shows no Howement when
the test jar is held horizontally for exactly 5 seconds,
note the thermometer reading at this solid point. The pour point is recorded as tee temperature 2PC above the
solid point.
Rotes
The cooling medlima usually employed are shown
below:-
Lower
Approx.
limit
Bout
fbr_
Material Pt.
Cooling Median
Aroolor 1260 2GOC ' ioe A Water .....
Ml'Oedd'cium
Aroolor 1254 10C
Aroolor 1248-6C
Ioe, Water and salt (KaCl) -
Crushed ioe and salt
-12C
Aroolor 1242 -20C Gasoline and solid CO.
~55C
Crushed lee and ealolua chloride crystals may be used 1br temperatures down to -25C.
ABC--hp
9/6/54
DSW 330761 STLCOPCB4077405
SUBJECT ; METHOD
OR TBS'.
14-23-32
Pour^ PpJumt jo f Aro c 10 rs _
ASTM. Designation D97~3
tyy ft
ASSEMBLED APPARATUS FOR POUR.; TEST
a. Test Jar, 4 oz. .oil sample bottle , i 3/16 to 1 5/16" i.a.
b. Test Thermo me ter, "ASTM Cloud & Pour -3^ to +50C." placed
so that beginning of capillary is 1/8" below surface of oil
c. Cork to fit test jar, center bored for test thermometer.
d. Jacket, water tight cvlinder, with inside diameter 3/S to
1/2 in. greater than s.d; of test jar,
-
e. Disk of cork or felt, 1/4" thick, to fit bottom of jacket,
fv Ring gasket, cork or felt, to prevent test jar from touch
ing jacket. Fits test jar tightly and loosely into jacket.
g. Cooling Bath with support for holding jacket vertically,
s. Sample; Height in test jar must be 2 to 2 1/4 inches. 7.
DSW 330762 STLCOPCB4077406