lfONSAHTOL XEEIUCAL COMPANY OF ALABAMA IHSPECTIQH DEPARTMEHT
DETERMIHAT IOH 07 POWER FACTOR OF LIQUID DIELECTRICS AT 100 C., 1000 FHEQPEHCY
A. Circuit Arrangement for Power Factor Measurement.
Power Source; 6 volt plate bat tery with Audio Oscillator, Gene ral Radio Type 213B giving frequenoy of 1000 ope.
T from 1000 ops. 080111atr
Capacity Bridge: General Radio Type 216. (M equal to H)
Telephone: Head phones with two stage amplification.
Cv : Variable Air Condenser,1500 MMF capaoity, G.R. Type 246-L.
Cp : Precision Condenser (var iable air), 1500 MMF capaoity, G.R. Type 222-L
Cu : The "unknown" Condenser with
liquid under test as dielectric. Plates of this condenser must be exceptionally well insulated to avoid introduction of errors.
Bridge balance is obtained by simultaneous adjustment of Cp
or Cv and the resistor R.
B. Procedure for Measurements. 1. Power factor is obtained from measurements of the capacity and the equivalent series resistance of a condenser (Cu) which has the substance under test as dielectric.
2. To secure these measurements, balance Cu and Cp (in parallel) against Cv. Record the capacitance reading (Cpa) of Condenser Cp and the resistance reading (Ra) on resistor R.
3. Disconnect Condenser Cu and again obtain balance, leaving Cv undisturbed. Reoord the capacitance reading (Cpb) of Condenser Cp and the resistance reading (Rb) on resistor R.
4. The oapaoitance (Ccu) in MMF of the Condenser Cu is Cpb minus Cpa. The equivalent series resistance (Hu) in ohms of the Condenser Cu is calculated from the equation Ru - (Ra - Rb)(Cpb)^.
' ' (fleuja 5* Calculate power faotor from the following equation where f is frequency in ops. PF in % * (6.28f) x Ru x Ccu x 10"10.
6. Corrections for equivalent resistances of Cp and Cu with air dieleotrio must be made if these are not negligible.
7. During measurements, Condenser Cu and its dielectric under
test are maintained at 100 C.
.