Document 6b7xv8kjqEQddpBz5wEDyQ9K3

MANUFACTURING CHEMISTS ASSOCIATION 1825 CONNECTICUT AVENUE, N.W. WASHINGTON, D. C, 20009 (202) 483-6126 /\ y APR 3 2 19/4 April 17, 1974 To: TECHNICAL TASK GROUP ON VINYL CHLORIDE RESEARCH Subject: Report on Conference with Industrial BIOTEST Laboratories, April 15, 1974 Gentlemen: As a result of the telephoned information received by MCA from Industrial BIO-TEST personnel last week, a conference at the Northbrook, Illinois offices of IBT was set up at which an oral status report on the chronic in halation studies with vinyl chloride was presented to MCA, industry and federal agency representatives. Those in attendance. and their affiliations, are shown below: Z. G. Bell, Jr. A. S. Cummin E. J. Fairchild J. W. Goode D. E. Gordon W. D. Harris M. N. Johnson, M Flynt Kennedy M. L. Keplinger R. J. Kociba H. L. Kusnetz D. V. Lassiter W. E. Rinehart W. M. Smith J. F. Stara T. R. Torkelson R. N. Wheeler B. M. G. Zwicker R. F. Blewitt A. C. Clark K. D. Johnson PPG Industries, Inc. Borden, Inc. NIOSH Industrial BIO-TEST Laboratories Industrial BIO-TEST Laboratories UNIROYAL, Inc. The B. F. Goodrich Company Continental Oil Company Industrial BIO-TEST Laboratories The Dow Chemical Company Shell Oil Company OSHA Ethyl Corporation Air Products & Chemicals, Inc. U. S. Environmental Protection Agency The Dow Chemical Company Union Carbide Corporation B. F. Goodrich Chemical Company MCA MCA MCA AS I 000017874 2- - Dr. Goode first presented the mortality data and gross observations, and then Dr. Gordon described the pathology observed in the mice. The data, as presented, are shown in the attached tables. There are apparent discrepancies between the total mortality data and the detailed listing of recent deaths. These will be re solved. No test-related pathology has yet been noted in any animals other than mice. Dr. Fairchild, of NIOSH, reported that Dr. David Rail, of HEW, had appointed a committee to coordinate departmental toxicology and related programs, and that under this committee there has been named a subcommittee to develop a "white paper" on guidelines for research to determine "socially acceptable" levels of risk. A report from this subcommittee, which will cover both philosophical (and statistical considerations, is expected in the next few 1 weeks. Dr. Stara expressed the view that the vinyl chloride problem presented industry with a unique opportunity to seek to demonstrate a "no effect level" of a human carcinogen with a sensitive animal model of well-documented validity. Dr. Lassiter expressed a guarded judgment that the mouse data reported by IBT would not lead OSHA to modify the emergency temporary standard, but that it might well cause OSHA to accelerate the rule-making process for the development of a permanent standard. I Dr. Lassiter also reported briefly on the retrospective j morbidity and mortality studies being conducted by NIOSH/CDC j at nine or ten locations (six companies) around the country. ,No epidemiological data were presented. In an afternoon session of the Research Coordinators, it was agreed that the exposure of the mice in the present project should be terminated at nine months, but that exposures of both rats and hamsters should proceed for the initially-planned twelve months. It was further moved, seconded and carried that the chairman appoint a group to begin investigating the cost and availability of facilities of new experiments to be con ducted at lower levels of exposure, with larger groups of animals. He was asked specifically to seek to encourage the National Center for Toxicological Research, at Pine AS I 000017875 -3- Bluff, Arkansas, to offer to undertake such a program. Details of the test protocol are to be left open until after the Rail committee makes its report available. The Research Coordinators asked MCA to call a meet ing of the Technical Task Group on Vinyl Chloride Research as soon as the report of Tabershaw-Cooper Associates on their epidemiological study reaches them. A copy of the MCA news release reporting the Industrial BIO-TEST mouse data has been sent to you in this morning's mail. Sincerely, Kenneth D. Johnson, Ph.D. Secretary Technical Task Group on Vinyl Chloride Research KDJ:mb Tables Attached cc : Mr. A. W. Barnes D. P. Duffield, M.D. Dr. Tiziano Garlanda Vinyl Chloride Management Contacts AS I 000017876 TABLE 3 Mouse Mortality Data DATE Controls FM February 10, 1974 28 GROUP TI Til FM FM 6 26 24 Till A- FM 78 April 12, 1974 5 11 9 31 13 7 13 18 AS I 000017877 JnduAtfaul Bl .) - TEST J?GAX),uit(yueA-, 5t%c. 1810 frontage road NORTHBROOK. II IlMOIS 60062 Summary of Tu 1 nors in Viny' ''hlor ide Exposed Mice IBT Number fab3 -03222-MCA TABLE XX faH.uy, Animal No., Sex PI is topa Biologic Findings Lung Liver Skin Date of Death Male ; p Female ' L 3 Fcma le M'M Female A A (s)* HS (s)** AA (s). Metastatic Skin Tumor HS (3) Metastatic Skin Tumor EC (para-aural) 3-20-74 3-24-74 EC MC+ (Femoral region) 3-30-74 1. r Female 139 5 Female ;< 0 Male j ' r.?, Female I * fa 0 Female 1 5 9 F emale T IfI 1938 Female 15 3?. Female 1562 Female 15 98 Female } 405 Male 1494 Male } 574 Female 15 31 Female 1588 Female 15 93 Female 150 5 Female 1565 Female 1409 Male 1543 Female 15 44 Female 154b Female 15 35 Female 14 32 Male 14 77 Female , , . .. __ Metastatic Skin Tumor IIS (s) AA (s) HS 1IS (s) AA (s) HS (s) AA (s) AA (s) AA (s) AA (s) AA (s) AA (s) AA (s) AA (s) HS (s) 1IS (s) IIS (s) HS (s) HS (s) IIS (s) HS (s) AA (s) A A (s) AA (s) AA (s) AA (s) AA (S) AA (s) HS (s) HS (s) HS (s) HS (s) HS (s) I1S (s) I-IS HS (s) AA (s) AA (s) HS (s) A A (s) HS (s) Meta static Skin Tumor ? EC( Abdomen) 3-5-74 3-18-74 3-25-74 4-2-74 4-5-74 EC 8* MC (Inguinal Region) 4-9-74 LS<> 3-6-74 3-7-74 3-8-74 2-25-74 3-22-74 3-22-74 EC k MC (Femoral region) 3-23-74 3-25-74 3-30-74 4-3-74 4-3-74 4-5-74 4-5-74 4-5-74 MC (Axillary region) 4-5-74 4-7-74 4-8-74 EC (Para-Aural) MC ( Abdomen) EC( Pelvic region) 4-9-7 ASI 000017878 Group T-I T-II T-III TABLE III 9rufaAt/iial BIO - T E S T JlaJs&iaJjiymA, 9m. 1810 FRONTAGE ROAD NORTHBROOK, ILLINOIS 60062 Summary of Mortality & Tumor Data Among Vinyl Chloride Mice IBT Number 663-03222 (MCA) No. Mortalities with Neoplasms Location of Tumors Lung Liver Skin Metastasis-> Lun; 4 (1 Male, 3 Females) 2(50%) 2(50%) 2(50%) 2 6 (1 Male, 5 Females) 3(50%) 4(66. 7%) 2(33%) 1 19 (4 Males, 15 Females) 17(89. 5%) 17(89. 5 %) 3(15.8%) Key to Symbols * Alveologenic Adenoma of J unp (AA) ** Hemangiosarcoma of Liver ( US) *** Epidermoid Carcinoma of Skin (EC) + Mammary Carcinoma of Skin (MC) (3 Lymphosarcoma of Thymus (s) Multiple tumors of indicated type .4- 4 i < t'K AS I ooooii 819 MANUFACTURING CHEMISTS ASSOCIATiqty, . g 1825 CONNECTICUT AVENUE, N. W. WASHINGTON, D. C. 20009 FOR RELEASE ------------------------------------------------------------------------------------- CONTACT: For Immediate Release Richard F. Blewitt (202) 483-6126, ext. 282 WASHINGTON, D. C., April 16 -- The Manufacturing Chemists Association (MCA) announced today preliminary indications that vinyl chloride exposure has produced angiosarcoma -- a liver cancer -- in mice at several exposure levels. Industrial Bio-Test Laboratories, Inc., who are conducting the MCA-administered vinyl chloride animal exposure study, informed MCA that their work -- although very preliminary at this point -- tends to confirm the findings of Professor Cesare Maltoni, an Italian scientist who found that vinyl chloride exposure in rats caused cancer. MCA immediately notified the Occupational Safety and Health Administration, the National Institute for Occupational Safety and Health and the Environmental protection Agency of the preliminary test results. In the MCA-administered study, rats, hamsters and mice are being exposed seven hours a day, five days a week, to 2500 parts per million (ppm), 200 ppm and 50 ppm. After seven months of exposure, angiosarcoma has been observed in mice at all levels, but not in rats or hamsters. (more) AS I 000017880 Page 2 of 2 Professor Maltoni reported at the OSHA hearings on vinyl chloride February 15 that he had observed the liver cancer in rats exposed four hours a day, five days a week, to 250 ppm for up to 12 months. However, he did not find the cancer in testing at the 50 ppm level. The animal exposure study is continuing. Another MCAadministered study on the chemical, documenting the health experience of present and former employees who have worked with the material, the results of which also will be released, is expected to be completed in the near future. Further vinyl chloride testing is under consideration. ### MCA-3339 AS I 000017881