Document 6b7jx97g8NEYX3qLXDr4e00BE

American Society of Heating and Ventilating Engineers Guide, 1935' the air is still (no wind), then for the same material fi and/Q are the same, and/i = /0; but if the outside air is in motion, then fQ is always greats than fi and will increase as the wind velocity increases. Values for f ja still and moving air have been determined for various building materials at the University of Minnesota under a cooperative research agreement with the Society1. The range of values for ordinary building materials is: comparatively small and for practical purposes may be assumed constantfor either still air or any given wind velocity, particularly in view of the' fact that the surface resistances usually comprise only a small part of the total resistance of the construction, except in the case of thin, highly; conductive walls. In determining basic heat transmission values for, building construction, it is customary to use that value of f0 which will occur when a 15-mph wind blows parallel to the outer surfaces considered.! Table I. Conductances of Air Spaces a at Various Mean Temperatures Mean Temp Deo Fash 0.128 Conductances op Air Spaces fob Various Widths in Inches 0.250 0.364 0.493 0.713 1.00 ---- 1.500 20 30 40 50 60 70 80 90 100 110 120 130 140 150 2.300 2.385 2.470 2.560 2.650 2.730 2.819 2.908 2.990 3.078 3.167 3.250 3.340 3.425 1.370 1.425 1.480 1.535 . 1.590 1.648 1.702 1.757 1.813 1.870 1.928 1.980 2.035 2.090 1.180 1.234 1.288 1.340 1.390 1.440 1.492 1.547 1.600 1.650 1.700 1.750 1.800 1.852 1.100 1.148 1.193 1.242 1.295 1.340 1.390 1.433 1.486 1.534 1.580 1.630 1.680 1.728 1.040 1.080 1.125 1.168 1.210 1.250 1.295 1.340 1.380 1.425 1.467 1.510 1.550 1.592 1.030 1.070 1.112 1.152 - 1.195 1.240 1.280 1.320 1.362 1.402 1.445 1.485 1.530 1.569 1.022 1.06S 1.105 1.149 1.188 1.228 1.270 1.310 1.350 1.392 1.435 1.475 1.519 1.559 VoI35Cri929)ReSiBtanCe f Air Spacea by F' B- Row'ey and A. B. Algren (A.S.H.V.E. Transactiok, : The conductances of air spaces at various mean temperatures and! widths, for ordinary building materials, are given in Table 1. These! results were likewise obtained at the University of Minnesota under a co-: operative research agreement Vith the Society. Values for k and C, the conductivity and conductance of building ma-! terials and insulations, are given in Table 2 as taken from the published; values of various investigators. It should be noted that values of k and; C as well as of U are dependent on the mean temperature, and it is.; therefore desirable that the investigator determine heat-transmission j values under conditions approximating those existing under actual con-- ditions. Recommended values for calculating the coefficients of trans-! mission of various types of construction are marked by an asterisk in J Table 2. I __)?artaACe Condactanaa as Affected by Air Velocity, Temperature and Character of Surface, by F. B.4 Rowley, A.B. Algren and J. L. Biackshaw (A.S.H.V.E. Transactions Vol. 36, 1930). See also reference* i at end of chapter; 106 Heat Transmission Coefficients and Tables The coefficients ore express Material n,,, an hour ter square fool ter degree Fahrenheit ter 1 in. thickness, unless otherwise indicated. Description Ss S I p || O gsg a5 fi p- p gg sS o s gs !1 os PS j Authoritt MaIoNRY materials Brice-------- --~ Brickwork^-- Damp or wet--.--........... ............... - Typical--------------------------------------------------- Ccrosa Concrete-------------Cinder Blocks6----:---- Typical-------............. ............... .............. Typical (8 in.). .....-- -.......... ------ Typical - , -'....... .................... ....-.......-- 1-2-4 mix.---------:--------------- ---------- iioTo 14376 a Typical gypsum fiber concrete, 87.5% Special concrete made with an aggregate Concrete Blocks*------ ------- ''* (1? in) ______________ ______ Special concrete block made with an aggre gate of hardened clay---4 x 8 x 16 in.. Special concrete block made with an aggre gate of hardened clay--8 x 8 x 16 -in.. 40.0 50.0 60.0 70.0 51.2 101.0 74.0 74.5 Typieal hollow clay (4 iol)------------------------- ____ fain)* . fa in ) Hollow clay (2 in.) H-in. plaster both sides 120.0 Hollow clay (4 in.) J4-in. plaster both sides 127.0 Hollow clay (6 in.) J^-in. plaster both tides 124.3 Solid gypsum------------------------------------------ Toe or Te&azzo...'.---------- Typical flooring________ ____ -- 51.8 75.6 75 69 75 75 75 75 5.00* 9.20* 5.00* 12.00* 5.20* 0.62f* 0.51t* 12.00* 9.46 11.35 to 16.36 1.06 1.44 1.80 2.18 74 1.66* 70 3.98 _ l.OOf O.SOf* 0.20 0.11 0.20 0.08 0.19 1.61 1.96 0.08 0.11 0.94 0.69 0.56 0.46 0.60 0.25 1.00 1.25 0.66t 1.51 0.30t 3.33 _ 12.50* 0.08 _. 12.00* 0.08 __ l.OOf* 1.00 0.64t* 1.57 0.60f* 1.67 0.58f* 1.72 0.40f 2.50 0.31f* 3.23 110 l.OOf 1.00 100 0.60f 1.67 105 0.47f 2.13 0.46f 2.18 70 1.66 0.60 76 2.96 0.34 12.00* 0.08 (2) (3) (4) (5) (3) 3(3) (3) (4) (3) _. (3) (3) -- -- -- -- -- __ (2) (2) (2) (4) (4) Authorities: 8. Bureau of Standards, tests based on samples submitted by manufacturers. *A. C. Willard, L. C. Iichty, and L. A. Harding, tests conducted at the University of Illinois. J. C. Peebles, tests conducted at Armour Institute of Technology, based on samples submitted by manufacturers. *F. B. Rowley, testa conducted at the University of Minnesota. A.S.H.V.E. Research laboratory. E. A. Allcut, tests conducted at the University of Toronto. rLees and Choriton. Recommended conductivities apH conductances for computing heat transmission coefficients. fFor thickness stated or used on construction, not per 1-in. thickness. For additional conductivity data see Table 14, Page 63,1934 A-S.1LE. Data Book. 6Recommended value. See Heating, Ventilating and Air Conditioning, by Harding and Willard, revised edition, 1932. One air cell in the direction of heat flow. *See AJJ.H.V.E. Research Paper, Conductivity of Concrete, by F. C. Hougbten and Carl Gutberlet (A.SJLV.E. Trans actions, VoL 37, 1931). * The 6-in., S-in., and 104s. hollow tile figures are based on two cells in the direction of beat flow. The 12-in. hollow tile is based on three cells in the direction of heat flow. The 16-in. hollow tile consists of one 10-in. and one 6-in. tile, each having two cefla in the direction of heat flow. /Not compressed. Roofing, 0.15-in. thick (1.34 lb per sq ft), covered with gravel (0.83 lb per sq ft), oombined thickness assumed 0.25. 107