Document 6b7QkKEevX7OLDpMe5rkjxw8d

.. _ Physical Chemistry Method No. 70-15 . Job Nos. 0435122 0449122 DETERMINATION OF POLYCHLORINATED BIPHENYLS IN AROCLOR 5460 BY CARBON SKELETON CHROMATOGRAPHY INTRODUCTION Aroclor 5460 is made by chlorinating Santowax R, a mixture of terphenyl isomers. In order for Aroclor 5460 to be used as a hot melt ashesive in food packaging, the level of polychlorinated biphenyls (PCB) in this product must be monitored to know that they are below a given level. PCB's result from residual biphenyl in the Santowax R. PRINCIPLE Direct gas chromatography cannot be used to monitor the PCB's be cause of overlap on the chromatogram between the higher chlorinated biphenyls and the lower chlorinated terphenyls. Therefore, carbonskeleton chromatography is used, in which a micro catalytic hydro genation unit is attached to the inlet of the gas chromatograph. All of the chlorines on the terphenyls and biphenyls in the sample are stripped off by this unit and the hydrogenated biphenyl is then sepa rated from the hydrogenated terphenyls by the gas chromatograph. APPARATUS 1. Perkin -Elmer Model 900 or equivalent programmed temperature gas chromatograph with flame ionization detector. 2. Modified Beroza Carbon Skeleton Determinator (Lab-built from design supplied by Ethyl Corporation). 3. Palladium Chloride Catalyst (Cat. No. 3-8010 Catalyst Charge, $2. 50/each, National Instruments Laboratories, Inc., 12300 Parklawn Drive, Rockville, Maryland). 4. 1/8" O.D. x 2 meter column of 10% SE-52 Silicone Gum Rubber on High Performance Chromosorb W, 60-80 mesh. PROCEDURE The Beroza Carbon Skeleton Determinator (CSD) is filled with several catalyst charges and attached to the inlet of the chromato- DSW 620512 STLCOPCB4094539 .. Physical Chemistry 70-15 Page 2.__________________ graph by inserting the large needle on the end of the CSD through the septum on the chromatograph. The carrier gas line is disconnected from the injection port inlet and rerouted to the front of the CSD. The injection port inlet is capped off. Hydrogen must be used as the car rier gas. Therefore, to provide optimum operation of the flame ionization detector, auxilary helium gas is added to the hydrogen carrier flow going into the detector. A helium flow about equal to the hydrogen carrier flow is suitable. The CSD temperature is maintained at 280C by connecting the heater cord to a Variac with temperature readout on a pyrometer connected to the thermocouple. The hydrogen carrier flow rate is 35 ml/min with helium auxilary flow rate of about 35 ml/min. The column is held at 135C for 2 min. after sample injection and then programmed to 300C at 10C/min. The injection port temperature is 315C and detector 300C. The sample is dissolved in cyclohexane to about a 50% solution and 0.5 ul injected into the CSD unit. They hydrogenated biphenyl, terphenyl and quatraphenyl peak areas are normalized assuming equal response for all three. A portion of Aroclor 5460 was purified by preparative gas chromatography to remove all biphenyls. A mixture of this material containing a known amount of Aroclor 1260 was run through this procedure to confirm that the assumption of equal response in the flame ionization detector for all hydrogenated species is valid. REFERENCES ' Literature references to the operation and application of the Beroza Carbon Skeleton Determinator are as follows: (1) Beroza, M., Anal, Chem. 34, 1801 (1962). (2) Beroza, M. and Sarmiento, R., Anal. Chem. 35, 1353 (1963). (3) Beroza, M. and Sarmiento, R., Anal, Chem. 37, 1040 (1965). APPENDIX Details of the construction of the modified CSD unit are given in figures 1 and 2. These are copies of two diagrams provided by SW 620513 STLCOPCB4094540 . . Physical Chemistry 70-15 Page 3. _____________ _______ Ethyl Corporation. A sample chromatogram is given in Figure 3. MONSANTO COMPANY Organic Chemicals Division Applied Sciences Section St. Louis, Missouri 7/70 E. M. Emery, G. M. Gasser DSW 620514 STLCOPCB4094541 7b- 'S'- tr \ *<0{ '^t. "r y j: ^ r *u, 1;_ "^ c>(/<->f; , t p V h v _ <r< _ ij 3 V* -;$ 2 i , Hi P*vS * i <S ^c VNi Q. * ^ \hl> ** 1 Si >\* nI e^o . 3 S> vT \ 'u ^ ^ ^ ^ l-J VU ^ ?yi * ^ V f* ~ 0 ^-' }3 s '-0 \ vT DSW 620515 <4 * STLCOPCB4094542 76^/S'- V o tQ k STLCOPCB4094543 1 STLCOPCB4094544