can blow to a point far away, wc get tfic idea we can draw in from far away. Wc cannot Mathematically speaking, wc "blow" about 30 times farther than wc can "suck." This is because air is drawn in uniformly from all directions, from almost a sphere surrounding the source of suction. But when you blow, the moving air is confined to a tube-shape^ pattern, or narrate cone, so its influence reaches a relatively long distance from the discharge point.
2. Place an exhaust hood so contaminated air is drawn away or down and away from the operator of the dust-making tool. In other words, don't use an overhead or canopy hood (like a conventional kitchen range hood) flint will draw the contaminated air up past the operator's nose. An exception: when particles arc driven off in a fixed direction, as by a pedestal grinding wheel, locate the hood so the dusty air shoots into it.
3. A simple smoke tube will show vis ually how air is moving in a room, and will quickly settle many an argument.
4. Be sure every local exhaust system lias an air cleaner. Wc can no longer use the outdoor atmosphere as a trash collector.
5. A disease like silicosis is caused by breathing dust that gets into the far reaches of tlic lungs. This means it's the particles of extremely fine size that arc important-- sizes of something like one-half to three microns in diameter (one micron equals 1/25,000 inch).. Such dust settles by gravity very slowly. A one-half micron particle in still air takes over three hours to fall one foot So the inhalablc dust of health sig nificance is wafted by air currents almost as though it were a gas.
The final step in a local exhaust project is all 'too'oftcn neglected. After the system i&nitibfalled and set in operation, its per formance should be checked to see it meets engineering specifications--correct rates of air flow, duct velocities, negative pressures, etc. Its performance should be rcchcckcd periodically as a maintenance measure. Proof of success is for the exhaust system to bring the concentration of harmful air contaminants to below their respective threshold limit values. Therefore, air samples should be taken and evaluated periodically during the life of the system.
Local exhaust ventilation is commonly used for controlling dust and otlitr air-borne
contaminants at grinding wheels, saws, spray painting, electroplating, degreasing, pickling, abrasive blasting, conveyor belt transfer points, welding, chemical laboratory hoods, and sources of other operations. Industry could not profitably conduct these processes without it It is ideal for such discrete, major sources of air contaminants.
For many small, scattered sources, general ventilation to dilute the contaminant in the room air is the only economical control measure. How much air to exhaust to pro vide safe ventilation by dilution can be cal culated with some precision. If you know, for example, how many pints of a certain solvent evaporate in a given time, a simple formula will tell how many cubic feet of outdoor air must be brought in to keep the solvent vapor in the room down to a safe level. By directing the pattern of flow so the incoming outdoor air first passes over the workmen, then goes through the con taminated area and finally outdoors, venti lation by dilution becomes rather effective. But this depends in large part on whether the pattern cf flow is encouraged or opposed by the direction of movement of outdoor air, for the latter can easily override man made indoor air currents.
There is one fundamental that sounds so simple it seems presumptuous to mention it, and yet it is forever being disregarded, even by otherwise good engineers. You can not remove air from a building by local or general exhaust without having replacement air enter to take its place. Otherwise the building will be under vacuum. (As a matter of fact, in wintertime all too many buildings arc.) Supply air systems that deliver tem pered outdoor air distributed through duct work with diffusers having adjustable louvres mounted eight or 10 foot above the floor arc a must, when air is exhausted for con taminant control.
They arc just as essential when exhaust systems arc used to remove hot air for reasons of employee comfort. In a large flat-roof plant, for example, hot air b often released by one or many roof exhaust fans. Here a makeup air system is also called' for, and there is even more reason for delivering it by ducts and diffusers so the men get direct cooling from the incoming air, which is' generally cooler and more comfortable than tlic in-plant air. Further heat relief