Document 6b4Zw0Xq2qZ6koQx3aNnzv189
CELANESE CHEMICAL COMPANY Chemcel Plant Bishop, Texas
Laboratory Department Summary - May 1973 -
RGB 43-73
Distribution: Messrs.
J. H. Frick - Bishop A. S. Baker W. C. Beyer T. N. Dowdy H. A. Ducote S. W. Fretwell E. J. Heinz L. D. Hinson J. M. Hodges M. A. John C. C. Johnson B. C. Kerr M. Lantau G. C. Lease C. W. Lee W. W. Massey J. T. McMahon
W. O. Me Reynolds
R. G. Pongetti R. H. Prinz G. C. Seaman W. L. Sharp B. F. Smith P. A. Turek R. H. Wile C. H. Wilke r K. A. Wolf
F. T. Talbert J. W. Corley J. M. Ramey T. D. Hunt
-
-
W. H. Tuke
-
F. B. McAndrews
Dr. F. Zitomer
-
W. E. Heinz
-
W. J. Humphrey -
W. T. McNair Dr. D.. R. Napier
-
W. E. Taylor
-
Dr. E. N. Wheeler
-
Central Files
-
Bay City Clear Lake NY CS Newark Terminal Pampa Summit Summit CCCTC CCCTC CCCTC CCCTC CCCTC CCCTC CCCTC
002593
"XELANESE^HEmCAL. COMPANY Chemcel Plant Bishop, Texas
To:
Mr. L. L. Schweers
From: R. G. Brandt
RGB 43-73
June 7, 1973
Laboratory Department Summary - May 1973 -
Status of Laboratory Department projects active during May are described below. Current priorities and department statistics are attached.
M O Support - Becker, Harris
Optimization studies of MO II and MO IV vaporizer blowdowns (to minimize iron entrainment) are complete (AFB 5,6-73, BPH 14,15-73). Work will be directed at evaluating the new high efficiency demister pad and methanol feed purification in the reflux of MO IV finishing column next month.
Water recycle from MS T-280 to T-279 is at the 18 gpm level (a 66% reduction in water recycle) with iron in the finished methanol at the 10-18 ppb level. This is probably the lower limit that can be maintained without sacrificing methanol quality. A report will be issued.
Seven samples of Engelhard silver catalyst were received and will be evaluated (sinter test and bench scale reaction efficiency) to determine if Engelhard can be approved as an alternate catalyst supplier.
Formcel Color Problem - Prinz, Kerr
Formcel colors continue to be a problem in spite of the fact that T-185 over head methanol is being tanked. Current efforts are focused on condensate quality as the probable cause.
Weak Formaldehyde Quality - Castoro, Harris
A report (CC 4-73) was issued recommending installation of static mixers for the TMP Unit and an oil decanter system for the weak formaldehyde unit to reduce unsaturates in the weak formaldehyde.
002594
To: Mr. L. L. Schweers
-2-
June 7, 1973
Paraform Support - Prinz, Lease, Harris
Analytical work is in progress to define which variables affect paraform production rates and quality.
A scale sample from the third stage evaporator reboiler tubes (obtained during boil-out) was identified as polymerized methocel (formalin stabilizer).
Samples of current paraform flake were forwarded to MTDL for applications testing. These tests are being conducted to determine if current flake quality is any different from VPO derived flake.
PE Quality - Kerr
PE color remains marginal as it has since start-up of the weak formaldehyde unit. The colored compounds were identified as polyhydroxy, unsaturated, carbonyl compounds. Formaldehyde and acetaldehyde feed quality are being evaluated.
PE Debottlenecking - Castoro
An analytical method is being developed for the PE-AML stream to measure PE and by-product losses during EVOP studies.
Molybdenum Promoted Nickel Catalyst - Jackson
R-4300 catalyst has been used successfully in 1,3 B. G. for two months. A status report will be issued.
Air Emissions - Jackson
Additional analyses planned to meet TACB reporting requirements include particulates on the PE scrubber (T-299) vent and bag house exhaust. Ash analysis of incinerator feed will also be required to calculate particulate emissions from this source.
In OSHA areas, air analyses for asbestos, MDI, and formaldehyde will be made in the Celcon area.
Analyses of butanol vent scrubber (T-192) vent were reported in JMJ 7-73.
Analysis of incoming acetaldehyde tankcar vents after unloading shows that
the AcH content varies from 1.6 to 12. 7 mole >. A report will be issued
002595
To: Mr. L. L. Schweers
-3 -
June 7, 1973
ASTM Support - Dow
Analyses of several urethane grade esters were performed in support of ASTM.
Propyl Acetate Quality - Brandt
A recent evaluation of propyl acetate produced from Carbide propanol in January shows that long term storage stability is poor. Even the best ester we made during this run developed considerable concentrated residual odor after four months. Re-examination of propyl acetate retains from the last three runs show that the last run had worse storage stability than the first two. These-findings aren't too surprising since the propanol being purchased
from Carbide was getting progressively higher incC methyl valeraldehyde
content.
We cannot recommend any further propyl acetate runs using Carbide propanol unless a significantly better grade can be obtained.
Condensate Reuse - Harris
MS process condensate was evaluated and found acceptable for boiler feed after de-aeration (C02 removal).
Weak formaldehyde pressure column (T-275) residue was evaluated. The stream contains 0.27% acid, 2500 ppm carbon, and 9 ppm iron which appears to rule out further reuse.
Waste Treatment Studies - Me Reynolds
Bench scale studies on six plant sumps were completed during the month. Four sumps representing about 10 gpm effluent were found acceptable as feed to the BOD plant. These were MH-2 Sump, TO-2 Sump, Celcon Pilot Plant Sump, and MO III Sump. Two additional sumps representing about 45 gpm were unacceptable as BOD plant feed. These two were Polyol Sump ('v'25 gpm) and TO-1 Sump ('v-20 gpm). A report will be issued.
Future work will be directed toward identification of the individual streams which make the Polyol and TO-1 sumps unacceptable. The Main sump will also be evaluated after it has been cleaned of nickel catalyst.
Anaerobic tanks are being fed a mixture of polyol, paraform, and Celcon sumps to determine effectiveness of this pre-treatment approach. One
002596
To: Mr. L. L. Schweers
_4 -
June 7, 1973
anaerobic system was constructed with packing to support the bacteria, second anaerobic system was constructed without packing and utilizes a stirred vessel to maintain bacteria in suspension.
The
RGB/bb Attachments: 2
R. G. Brandt
002597
June 7, 1973
CURRENT PROJECT PRIORITIES
Priority
Waste Treatment Formalin Quality Paraform Debottlenecking and Quality Pentaerythritol Quality (Color) Formcel Color Problem Propanol Support Post Aldol T-135 Res. Recovery Pentaerythritol Debottlenecking and Efficiency TMP Debottlenecking Weak Formaldehyde Recovery Celcon Support MO Optimization New Silver Catalyst Supplier MS Steam Savings Molybdenum Promoted Nickel Catalyst T-135 Chloride Balance Air Emissions
1 1 1 1 1 2 2 1 2 2 1 1 1 2 1 1 1
Chemist
Me Reynolds Lease Lease, Prinz Kerr Kerr Kerr Kerr Castoro Castoro Castoro Gary Becker, Harris Becker, Harris Becker Jackson Jackson Jackson
002598
June 7, 1973
STATISTICS
Chemical Section Samples Instrument Section Samples Celcon Section Samples
Total
May
4, 637 1,873 2,267
8, 777
YTD
23,642 10, 807
8, 175
42,624
Prev. YTD
24,062 11,190
9.663
44,915
Sample Shipping - Domestic - Export - Celcon - Other
T otal
175 5
10 30
220
843 28 75
141
1,087
842 32 42 64
980
Technicians Overtime - Hours Chemical Instrument Celcon Special Problems
Total
21 0
311 16
348
375 65
866 34
1,340
367 259 241 187
1,054
Shipments (No. of orders) Delayed Shipments Quality Waivers Customer Complaints Customer Complaints Accepted
942
0
o.
2
1
3,919 11 0 6 4
'
3, 567 16 13 9 8
* 44% HCHO to Carbide - Resin made from the material had a red color
50% HCHO to Georgia Pacific, Albany, Ore. - High parafo:rm content in the formalin.
002599