Document 6b3mgk0oV0e8xJwXZM2q8NX9m

KNOX, RICKSEN, SNOOK, ANTHONY & ROBBINS One Kaiser Plaza, Suite 850 2 Oakland, California 94612 AUG 241983 A HHERtR/O* N & HE.R..R..O.N. 3 Attorneys for Defendant, COMBUSTION ENGINEERING, INC. 4 5 6 7' 8 SUPERIOR COURT OF THE STATE OF CALIFORNIA 9 COUNTY OF ALAMEDA 10 (4 IS) 893- 1000 O AKLAND, CAw.EORNIA 94612 A. SUITE 850 OROWAY B U ILD IN '" KAISER CENTER 3 N U U H , A N IH O N Y a R O B B IN S 11 ) IN RE: DISCOVERY FOR RELATED ) 12 SHIPYARD ASBESTOS CASES (HERRON) ) ) 13 ) ) 14 ) ) 15 ) 16 No. 795 582 COMBUSTION ENGINEERING, INC.'S RESPONSES TO PLAIN TIFF'S SECOND SET OF INTERROGATORIES ONE KAISER 17 PROPOUNDING PARTIES: 18 CONSOLIDATED SHIPYARD ASBESTOS CASES OF HERRON 19 RESPONDING PARTY: COMBUSTION ENGINEERING, INC. 20 SET NUMBER: TWO 21 Defendant COMBUSTION ENGINEERING, INC. answers and 22 objects to plaintiff's interrogatories as follows: 23 GENERAL OBJECTION APPLICABLE TO ALL INTERROGATORIES 24 COMBUSTION ENGINEERING, INC. objects to these interroga- 25 tories to the extent that they are overboard and unduly burdensome 26 and oppressive in that they seek information which is neither / 1 1 relevant to the subject matter of this action nor reasonably 2 calculated to lead to the discovery of admissible evidence. 3 In particular, COMBUSTION ENGINEERING, INC. objects to 4 use of contention interrogatories in that there are no adversary 5 issues between defendants raised by the pleadings although this 6 defendant reserves the right to prove any and all facts regard 7 ing the mining, supplying, distributing and/or manufacturing 8 of asbestos or asbestos containing products and/or materials 9 at time of trial. 10 This defendant COMBUSTION ENGINEERING, INC. answers 11 interrogatories as follows: 12 NO. 1 13 Frank T. Christenson; Assistant to Vice President of 14 Industrial Sales; C-E Refractories of Combustion Engineering, Inc.; 15 P.O. Box 828; Valley Forge, Pennsylvania. 16 NO. 2 17 Yes 18 (a) Combustion Engineering, Inc. 19 (b) Delaware 20 (c) 900 Long Ridge Road, Stanford, Connecticut 21 (d) Yes 22 (e) Public 23 NO. 3 24 October 25, 1912 - The Locomotive Superheader Co.; 25 March 1, 1921 - The Superheater Co.; December 31, 1948 - Combustion 26 Engineering - Superheater, Inc; April 15, 1953 to date - Combustion 2. M i'll r lU N Y Ot N O B B IN S KAISER CENTER A. SUITE 850 A 4 I 'Engineering, Inc. 2 NO. '4 & 5 `3 Refractory and Insulation Corp. The Insulation Division 4 of M.H. Detrick Co.; Walsh Refractories Corp. 5 NO. 6 6 No. 7 NO. 7 8 During the time that this Defendant was in the business 9 of manufacturing asbestos-containing products, i.e., from 10 mid-1963 through 1972, it maintained no organization charts 11 specifically with respect to such business. CO o !3 O AKLAND, C A -.F O R N IA 94612 2 ,,m 3 "" < 5W zC go <: - pi 1s u S zgS D 5^O< (415) 8 9 3 - 1000 12 1123 Defendant objects to this interrogatory on the ground 14 that it is entirely irrelevant to any of the issues involved in 15 this case. This Defendant was in the business of manufacturing . 16 asbestos-containing insulation products from June 5, 1963 through 17 1972, and the corporate minutes for that entire period of time 18 have been reviewed and there is no mention of asbestos or 19 asbestos-containing products in any such minutes. 20 NO. 9 21 Defendant objects to Interrogatory No. 9 on the ground 22 that it is entirely irrelevant to the issues in this case. More- 23 over. Defendant is a public corporation and its annual report is 24 readily available to plaintiff. Therefore, plaintiff can. 25 if he wishes, obtain such information. 26 //// , 't'K ONE KAISER noci L D IN o UI B ORDWAY 3. ' 1 NO. 10 2 No. 3 NO. 11 ' 4 This Defendant manufactured and sold asbestos-containing 5 insulation products beginning on June 5, 1963 and discontinued 6 such activities in 1972. 7 NO. 12 8 (a) (b) (c) (d) (f) See Exhibit "A", attached hereto. 9 (e) For the most part, these products were white or 10 off-white. Defendant has no records of the various logos used on 11 the packaging, but there were no logos on the product itself. 12 (g) The manufactured asbestos-containing products 13 can be segregated into four categories. A description of the 14 various processes follows: ' 15 (1) Insulating Cements, Fills and Insulating Castabl< 16 Ingredients were proportioned, mixed and bagged. 17 Quality control procedures involved measuring the adhesiveness 18 of the product and measuring shrinkage of a sample which was wet 19 and then dried. Coverage was also measured occasionally. Insula 20 ting castables were tested for modulus of rupture, compressive 21 strength, density and screen analysis. 22 (2) Mineral Wool Block - Griptex 23 This product mix was weighed, mixed with water, 24 extruded to desired thickness onto wire mesh trays. The trays 25 were then dried in an oven; the block removed, trimmed, cut if 26 necessary, and placed in cartons. Quality control involved 4. ` I weighing the block, testing for compressive strength and 2 occasionally for shrinkage at temperatures. 3 (3) Insulating Block 4 The product mix was weighed, mixed with water; the 5 slurry poured into boxes where water was suctioned from the slurry! 6 leaving a "blank" or "slug", 12" x 36" x 6" thick. The slug was 7 put in a curing chamber on trays, then transferred to a drying 8 oven. After drying, they were trimmed and cut into various sizes 9 and thicknesses, then placed in cartons. Quality control procedurjc 10 were to test for density and compressive strength. Shrinkage at 11 temperatures was also tested occasionally. 12 (4) Wet Mix Products 13 These products were weighed, wet mixed and packed in 14 steel drums. Quality control procedures were to test for 15 consistency, moisture loss and screen analysis. 16 (h) Combustion Engineering, Inc. 17 (i) Unknown 18 (_n None - Not applicable 19 (k) Defendant has no records from which it can answer 20 this interrogatory with specificity; however. Defendant believes 21 that during the time this Defendant manufactured asbestos-contain-j 22 ing insulati n products, i.e., from June 5, 1963 through 1972, it 23 obtained raw asbestos from the following companies: Johns-Manvillje 24 Corp., Empire Ace Manufacturing Co., George A. Rowley Co., 25 Asbestos Spray Co., Carey-Canadian Mines, Ltd., Chicago Firebrick 26 Co., Asbestos Corp. 5. 1 (1) Yes 2 (i) and (ii) This Defendant's distributor in 3 California from 1968 through 1972 was Pryor Giggey Co., of Santa I 4 Springs, California. 5 During said period, the following sales were made to 6 the Pryor Giggey Co.: 7 1968 - Griptex Insulating Block, $499.32; Super 711 8 Insulating Cement, $306.00 9 1969 - No sales 10 1970 - Griptex Insulating Block, $3,952.80; Super 711 11 Insulating Cement, $227.80 12 1971 - Griptex Block, $3,868.56; Super 711 Cement, 13 $594.00 14 1972 - Griptex Block, $9,454.32; Super 711 Insulating 15 Cement, $342; Stic-Tite Insulating Cement, $114 16 Defendant has no records prior to 1968. 17 (iii) What records exist are in the custody of 18 Frank T. Christenson. See interrogatory No. 1 19 (m) To the best of this Defendant's knowledge, no. 20 (n) See answer to Interrogatory No. 12 (1) (ii). 21 (o) See Exhibit "A", attached hereto. 22 (p) Sales records. Further, see answer to Interrogator] 23 No. 12 (1) (iii). 24 NO. 13 25 See answer to Interrogatory No. 12 26 //// 6. ' 1 NO. 14 2 See answer to Interrogatory No. 12. 3 NO. 15 4 This Defendant is unaware of what sales may have been 5 made by any company listed on Exhibit "A" other than itself. 6 NO. 16 , 7 This Defendant is unaware of what sales may have been 8 made by any company listed on Exhibit "A" other than itself. 9 NO. 17 10 Not applicable. II NO. 18 12 Not applicable. 13 NO. 19 14 See answer to Interrogatory No. 12 (k). 15 NO. 20 16 This Defendant distributed a product called Weatherkote, 17 which consisted of asbestos fibers in an emulsion. This product 18 was manufactured by the Flintkote Corporation and their name for 19 the product was Thermalkote. See Exhinit "A" for inclusive dates. 20 NO. 21 21 To the best of this Defendant's knowledge, no. 22 NO. 22 23 See Exhibit "A", attached hereto. This Defendant has 24 no records of the various logos that appeared on the packaging. 25 In 1969, the following appeared on the packaging of all asbestos26 containing materials: "CAUTION: This product contains asbestos. 7. * 1 Excessive inhalation of asbestos may be harmful. If adequate 2 ventilation is not possible, wear respirators approved by u.S. 3 Bureau of Mines." 4 NO. 23 5 No. 6 NO. 24 7 Yes. ! 8 (a) See answer to Interrogatory No. 22. In addition 9 see Exhibit "B" attached hereto. 10 (b) 1969 - 1972 11 (c) This Defendant has no records from which it can 12 answer this interrogatory with specificity; however, it is this 13 Defendant's understanding that an awareness of the health hazards 14 of asbestos was the main consideration for using the warning. ' 15 (d) None. ' 16 (e) This Defendant has no records from which it can 17 answer this interrogatory with specificity. 18 NO. 25 19 No. 20 NO. 26 21 Not applicable. 22 NO. 27 23 This Defendant has no records from which it can answer 24 this interrogatory with specificity; however, it believes that 25 its name and logos did appear on the packaging of the various 26 asbestos-containing insulation products. 8 (415) 893- 1000 OAKLAND, C A _.rO R N IA 94612 A. SUITE 850 ORDWAY BUILDING KAISER CENTER -----j m / u i i , m i i n u N T Oc N U B B IN S * 1 NO. 28 2 Warnings were placed on the packaging. See previous 3 answers. 4 NO. 29 5 No. Proper use and application of this Defendant's 6 asbestos-containing products were left to industry practice. 7 NO. 30 8 No. 9 NO. 31 10 See answer to Interrogatory No. 24 (d) and (e). 11 NO. 32 12 This Defendant did not advertise its asbestos-containing| 13 insulation products. 14 NO. 33 15 This Defendant objects to Interrogatory No. 33 on the 16 grounds that it is entirely irrelevant to the issues involved 17 in this case. Moreover, this is an obvious attempt by plaintiff 18 to harass this Defendant, who has been involved in excess of 19 8,000 asbestos claims. To require Defendant to make such lists arjd 20 to product such depositions is burdensome and harassing to this 21 Defendant. 22 NO. 34 ' 23 24 25 26 //// No. NO. 35 No. ONE KAISER 9. 1 NO. 36. 2 No. 3 NO. 37 4 No. 5 NO. 38 6 NO. 7 NO. 39 8 NO. 9 NO. 40 10 This Defendant has no records from which it can answer 11 this interrogatory with any specificity, although this Defendant 12 believes that very little, if any, of its asbestos-containing 13 products was transported to the San Francisco Bay Area. 14 NO. 41 .' 15 This Defendant has some incomplete, material from 1964 16 and some material from 1970 which was informational and given to 17 distributors of this Defendant's asbestos insulation products. 18 Said material is attached hereto as Exhibit "C". 19 NO. 42 20 To the best of this Defendant's knowledge, no. 21 NO. 43 22 No. 23 DATED: August 22, 1983. 24 25 26 Miipert H. Ricksen Attoran/n<eys for Defendant COMBUSTION ENGINEERING, INC. 1 I, RUPERT H. RICKSEN, hereby declare under penalty 2 of perjury that I am one of the attorneys for Defendant 3 COMBUSTION ENGINEERING, INC., a corporation, in the above- 4 entitled action; that said defendant maintains its principal 5 place of business outside of the county in which I maintain 6 my office and place of business; and that for that reason I 7 make this declaration for and on behalf of said defendant; 8 that I have read the foregoing RESPONSES TO PLAINTIFF'S SECOND 9 SET OF INTERROGATORIES and know the contents thereof and the 10 same is true of my own knowledge except as to those matters 11 therein stated upon information or belief, and as to those 12 matters, I believe it to be true. 13 Executed at Oakland, California, this 22nd day of 14 August, 1983. 15 16 17 18 19 20 21 22 23 11. state*, and over the age of It year*, and not a party to the within action; By business address is ONE KAISER PLAZA, SUITE (850, OAKLAND, CA, 94612. Z executed this declaration and served a true copy of the foregoing document by mail by placing same in an envelope, sealed, fully prepaid postage thereon and depositing said envelope in the U. S. Mail at Oakland, California, on the 7 7 day of August 198 3 . addressed as follows: A.C and S. VAN DE POEL STRICKLAND 36 - 14th St, *1316 jakland, CA 94612 ( ) CERTAIN-TEED ( ) GENERAL MOTORS FREITAS, MCCARTHY, BETTINI, et al tARICHAN, RENBERG, et al 960 - 5th Avenue 2350 W. Shaw, St*. *130 San Rafael, CA 94901 Fresno, CA 93711 ARMSTRONG CORK GUDMONDSON, SIGGZNS STONE 235 Montgomery Street San Francisco, CA 94104 ( ) THE CLAREMONT CO., INC. WILD JEFFREY 10 Vinton Court at Grant Avenue San Francisco, CA 94108 ( ) GEORGIA PACIFIC CORP. MARRON, REID SHEEtf One Nob Hill Circle San Francisco, CA 94123 ( ) ASARCO - LAKE ASBESTOS PETTI* MARtiN 600 Montgomery Street San Francisco, CA 94111 f J ASBESTOS CORPORATION < ) SOUTHERN PACIFIC CROSBY, HEAFEV, et. al. 1939 Harrison Street Oakland, CA 94612 ( ) BABCOCK WILSON ANDERSON, GALLOWAY, et al 2201 Broadway *319 Oakland, CA 94612 ( ) BRINCO MINING, LTD. STARK, STEWART, et al 180 Grand Avenue Oakland, CA 94612 CROWN CORK 4 SEAL FoSd MOTOR COMPANY MARK H. ROSENTHAL, ESQ. 3 Embarcadero Ctr.. San Francisco, CA 94111 EAGLE-PICHER WININGHAM, ROBERTS ROGIE 425 California St., *401 San Francisco, CA 94104 ( ) E.I, duPONT, deNEMOURS CO. PILLSBURY, MADISON SUTRO 225 Bush Street San Francisco, CA 94111 Kl FIBREBOARD LAW OFFICES OF RONALD E. HOTHEM 369 Broadway San Francisco, CA 94133 H. K. PORTER - SO. TEXTILE LAW OFFICESOF WILLIAM J. DUKE 433 California St., *330 San Francisco, CA 94104 LEACH SCHNEIDER, APC 2833 Laguna Street San Francisco, CA 94111 ( ) J. P. STEVENS CARROLL. BURDICK, et al 1 Ecker Bldg., *400 San Francisco, CA 94105 ( ) KAISER ALUMINUM CHEMICAL KAISER STEEL CORP. THELEN, MARRIN, JOHNSON, et al 2 Embarcadero Center San Francisco, CA 94111 ( ) BELL ASBESTOS RUSS DANIELS 333 Market Street San Francisco, CA 94133 ( ) FLEXITALLIC GASKET CO., INC. BLEDSOE, CATHCART, BOYD, et al 650 California St., Ste. 2828 San Francisco, CA 94108 Wl KAISER CEMENT GYPSUM ' KINCAID, GIANUNGIO CAUDLE 100 Webster Street, 1300 Oakland, CA 94607 ( J BENDIX CORPORATION Gordon & rees 601 Montgomery Street San Francisco, CA 94111 6ft FLINTKOTE LaFOLLETTE, JOHNSON 320 No. Vermont Ave. Los Angeles, CA 90017 -fc/f ~ KEENE CORP. mullally,"JEDERBORG, et al 436 - 14th Street, *1405 Oakland, CA 94612 ( ' `THLEHEM STEEL LLIAM PARRISH 2710 California St. San Francisco, CA 94115 : ) BIGELOW-LIPTAK CO, COOPER, WHITE COOPER . 44 Montgomery St. San Francisco, CA 94104 ) CASSIER ASBESTOS STARK, STEWART, et al Fidelity Plaza, 14th Fir. 180 Grand Avenue Oakland, CA 94612 CELOTEX BERRY BERRY 1221 Broadway Oakland, CA *1880 94612 ) NORTHWEST COPPER WORKS ELIZASSEN, POSTIL, et al 50 California St., *600 San Francisco, CA 94111 6 OWENS-CORNING POPELKA, ALLARD, et al 1 Almaden Blvd. 8th Fir. San Jose, CA 95113 0 OWENS-ILLINOIS MOKGENSTEIN, LADD, et al 255 California St., 8th Fir. San Francisco, CA 94104 ') PITTSBURGH CORNING HASSARD, BONNINGT0N, ROGERS 44 Montgomery St., <3500 Francisco, CA 94104 1 PLANT INSULATION (PLANT ASB) LEACH SCHNEIDER 2833 Laguna Street San Francisco, CA 94123 (74 FORTY-EIGHTY INSULATIONS ' ' DILLINGHAM MURPHY 225 Bush Street San Francisco, CA 94104 bd GAF - RUBEROID MctUTCHEN, DOYLE, etc. *3 Embarcadero Center San Francisco, CA 94111 06 GARLOCK - COLT LTD. GLASPY, ELLIOTT, CREECH 171 - 12th St., *100 Oakland, CA 94607 ( > GENERAL DYNAMICS PELAVIN, NORBERG, HARLOCK, et al 2 Embarcadero Center, 23rd Fir. San Francisco, CA 94111 ( 1 PPG INDUSTRIES BISHOP BARRY 220 'Bush Street, *350 San Francisco, CA 94104 (*PPG*Non-Sac./Solano Cases) RAYBESTOS MANHATTAN ' kALONEY, CHASE, FISHER *4 Embarcadero, 25th Fir. San Francisco, CA 94111 { ROCK WOOL HFG. CO. Berg piifiLM 615 S. Flower St.,- *1900 Los Angeles, CA 90017 ( 1 RYDER INDUSTRIES JAMES ENGLISH 400 Montgomery Street San Francisco, CA 94104 ( ) SACOHO-SIERRA. INC. SAComa kRG. to?,' Inc. BRONSON, BRONSON MCKINNON 555 California St., St*. 3400 San Francisco, CA 94104 ( ) MUNDET CORK XHERRON & HERROj CROWN/FORD MOTOR CO. BARFIELD, BARFIELD, et al 600 Montgomery One California St., (2125 San Francisco, CA 94111 Street, 33rd Floor >< NATIONAL GYPSUM COMPANY OWEN, MELBYE ROHLFF San Francisco, 700 Jefferson Avenue Redwood City, CA 94063 California 94111 M NICOLET ST. CLAIR, ZAPPETTINI 235 Montgomery St., (635 San Francisco, CA 94104 ( ) NORTH AMERICAN ASBESTOS ERICKSON, MACKENROTH 100 Oak Street Oakland, CA 94607 ( ) SOUTHERN TEXTILE LAM OPPICES'OP MM. J. DUKE 433 California St., *330 San Francisco, CA 94104 ( ) STANDARD ASBESTOS LA POLLETtfE, JSHMSON 320 No. Vermont Avenue Los Angeles, CA 90004 M WESTERN HACARTHUR HARDIN, COOK, LOPER *1 Kaiser Plaza, *171 Oakland, CA 9461 ( ) STATES STEAMSHIP CO. LOW, BALL LYNCH 601 California St. San Francisco, CA 94108 (> THORPE INSULATION JAMES CUSICK 4201 Wilshir* Boulevard Los Angeles, CA 90010 Charlene { ) TURNER NEWALL H)N(5eR, *OOLES " RICKERSHAUSER 612 So. Flower Street Los Angeles, CA 90017 Kay# J PLANT ASBESTOS MARTIN RYAN LAW OFFICES Ordway Bldg., *785 Oakland, CA 94612 SEPCO CORP. RANDOLPH, SELMAN LEVANAS 11620 Wilshir* Blvd. Los Angeles, CA 90025 U. S. GYPSUM JOHN 8. MURRAY, ESQ. 702 Marhsall St., *250 Redwood City, CA 94063 B[foSOUBT3=aBAL INSULATIONS TECHNICAL DATA A DIVISION OF COMBUSTION ENGINEERING. INC. ExhiGiT (E !B. ..gygB'BHTOWBBWWBMPWWIlWftaiaujJi ii usa ssisa.wtcirKW!Ui a ok be a t ASBESTOS ROPE a division of combustion ENGINEERING. INC. . Lflf jr-WWf-*1(iUrTl.l.*in'rV'rTril-'O-tif-'i-f TV--~ * u;p.'i nnnn.w..irl . " ' 500 ROPE IS A COMMERCIAL GRADE. WHITE CHRYSOTILE ASBESTOS FIBER. 1000 ROPE IS A PURE 98/100% WHITE CHRYSOTILE ASBESTOS FIBER. ,.,T|. -VI | ,|| APPLICATIONS OF C-E ASBESTOS ROPE . . HERE ARE SOME OF THE MANY SERVICES ' STEEL MILLS AND FOUNDRIES '' . Uses for C-E Asbestos Rope are almost endless. Sealing molds?-vacuum-pouring equipment (where leakage can ruin an entire billet), sand molds off from pouring ladles,"talking joints in large cores which must be segmented. ATOMIC ENERGY ** _ * * , 1000 is standard in the Industry because it withstands an integrated neutron flux of 10*9 NTV units. MARINE SERVICE. . .. . C-E Asbestos Rope is essential in the Engine Room for general boiler service such as calking, filling and expansion joints, .wrapping hard-to-reach steam lines and in emergencies, for quick repair of damaged steam ' lines. ' GENERAL INDUSTRY . j . Anywhere heat sealing is required, whether heat-treating furnaces, boilers or processing operations. . f POWER PLANTS *. ` Between boiler walls and brick-work to allow for expansion and contraction, wrapping steam and exhaust lines where space limitations preclude formed insulation, covering small ducts, calking hard-to-reach spaces, insulating hot pipes passing through fire-walls and bulkheads. It is the standard for use in grooves for door sealing, between boiler sections, expansion joints and in handling hot gases. ' ASBESTOS ROPE CAN HANDLE EFFICIENTLY AND ECONOMICALLY CHEMICAL INDUSTRIES , C-E lOOrT rope is successfully used as calking rope for bell and spigot joints in chemical lines. Because it contains no organic components, it is used as yarning rope for water lines. In addition to its heat-resistance, the chen.cally inert characteristics have made it a ''standard" in other chemical-handling operations such as packing for carboy-stoppers, and in Cryogenic services, and other applications where this property is required. ` ALUMINUM PLANTS Anywhere the control of heat and sealing is needed-heat-treating ovens, grooves for door sealing, pouring ladles, vauum seals on crucibles, and in many other dry heat-sealing spplications, C-E Rope is recommended. -;v/215-783-CW50..; . TWX-v5i 0-660-4S37.. -= - 'Ijau3si Rfcli-yriMMLi S111 Kilty A DIVtSION OF COMBUSTION ENGINEERING. INC. >* . 'ilHl tl|>W GRIPTEX RLOCK INSULATION HVTWII M J!S; Griptex* is a major development in insulation offering a unique combination of characterises. Special mineral fibers combined with high temperature bonding materials, provide practical advantages. The embossed hard finish surface provides superior handling strength and stronger adhesion of cement finishes. The combination of flexibility and high strength make impaling over welded pins easy, without pre-drilling. The neutral PH of * Griptex Block assures against corrosive action. This particularly is important when used in conjunction with aluminum jacketing. . . . Hydraulic setting cements and castable refractories may be applied directly to Griptex Block without premature loss of mixing water needed for proper hydration. -v ' ; EFFICIENT ` . . The felted fiber core of Griptex Block offers the maximum buffering action against heat penetration up to _ 1800F. The thermal conductivity at 200F. means temperature is .37 BTU; at 600 F. it is .49 BTU. APPLICATION METHODS `' . r - . . ' Griptex may be simply impaled over standard welded pins and secured with speed clips or may be secured in place with metal oands. A sharp knife is the only tool needed to fabricate Griptex to fit irregular shaped equipment. "Simply press over bolt heads and projections without additional cutting. Outdoor applications should be weatherproofed. - . RECOMMENDED USES BOILERS . Drums . - - Headers , Walls . Economizers Air Preheaters FURNACES Heating . Heat Treating Forging Annealing Normalizing OVENS, KILNS & DRYERS FIREPROOFING TANKS & VESSELS TURBINES & PUMPS FAN HOUSING DUCTS & BREECHINGS SPECIFICATION REFERENCES . High Temperature mineral fiber block insulation shall be GRIPTEX complying with the performance requirements of ASTM C-392, Class 2; Federal Specification HH-1-564 and/or Commercial Standard CS-117 .of the U. S. Department of Commerce. . *A C-E trade name. R'f'-i; 1,11 ap ^215^83-0450 - v.Lj JTWX'S1066IW837 | "S'* ; | maussa li'seimMiU 11 HiKSfcSa ? SUPER FINISH STIC-TITE '.i : A DIVISION OF COMBUSTION ENGINEERING. INC. * . . XUgaigV'T^."rs.~c.&.>.' */'', n tir- r i v >*Tnrfr~~iii'ii~TiTf"ii'li--n"r-mnmrTYrrmiT nri>< rwwr nund A SMOOTH, ONE-COAT PLASTIC FINISH INSULATION Super Finish Stic-Tite provides a smooth, hard, fibrous finish covering for insulating blankets, block, standard Stic-Tite and other insulations. It is a dry. finely ground, pure white mixture of high quality mineral wool and diatomaceous earth which, when mixed with the proper amount of water, is ready for instant use. Like standard Stic-Tite, it forms a spongy mass of dead air cells which stops air infiltration and resultant heat loss. . NO ROUGHING COAT-FINISHES SMOOTH ^ ' Super Finish Stic-Tite is applied in a single coaL Jt can "be troweled very smooth for pleasing white appearance. No roughing coat is needed, thereby saving materials and labor. It does not shrink or crack. There is no pointing up or patching necessary after Super Finish Stic-Tite has dried. ' USE SUPER FINISH STIC-TITE WHEN a perfectly smooth, one-coat plastic finish insulation is specified for temperatures up to 1700F. . WHEN necessary to cover blankets, block or standard Stic-Tite in order to provide a smooth, hard, white surface. ' .' ' ' ' --..r ' DOESNT COME OFF ` ., . .' Super Finish Stic-Tite adheres strongly to overhead, vertical and curved surfaces and rounded corners. Once it has dried, the bond is unaffected by vibration, impact or moisture. . .. CAN BE APPLIED ON COLD OR HOT SURFACES . . . ' Because it doesn't shrink during drying. Super Finish Stic-Tite can be applied directly to cold or hot metal or brick surfaces up to 175F. It dries hard, without shrinking, in about 2 hours. When applied to hotter surfaces, a rough coat of standard Stic-Tite is recommended. . ' GOES A LONG WAY .` Super Finish Stic-Tite gives excellent coverage. One hundred pounds cover an 80 sq. ft. surface with a 1/2" thick layer; 120 sq. ft. with a 3/8" thick layer; or 160 sq. ft. with a 1/4" thick layer. This is by far the lowest cost coverage of any other one-coat finish insulation available. HOW TO APPLY SUPER FINISH STIC-TITE 1. Mix Super Finish Stic-Tite tho< jughly with 5 to 6 gals, fresh water per 25 lb. bag. 2. Allow the cement mix to soak for one-half hour before using to insure maximum workability. . . 3. . Mix no more than .will be applied in 4 hours. 4. If any of the batch has dried out. do not remix it with water or fresh, dry material as the resultant finish will not be hard. Use only fresh batches. . 5. For smoothest finish, trowel the cement to at least 3/8" thickness. . 6. Where used as a finish coat over an insulating cement roughing coat, be sure the undercoat has set overnight before applying Super Finish Stic-Tite. 7. Where a given area cannot be finished in a continuous application, the joints should be leather-edged.::^^^.': rn ir ii hi mi tarn SOMMARY OF PHYSICAL PROPERTIES Use Limit ' ' Sintering Temperature Thermal Conductivity Compressive Strength Density . Stability Resistance to' Moisture Resistance to Corrosion Handling Characteristics Up to 1800F. 2100'F. See Accompanying Graph 18 psi 1.25 lbs./bd. ft. Inert * durable Water-repellent Noncorrosive Excellent - THERMAL CONDUCTIVITY-GRIPTEX BLOCK THERMAL CONDUCTIVITY ' . 'MEAN TEMPERATURE-F STANDARD SIZES 6"x12" 6"x18" ' ` * 6"x36" ' 12"x12" 12"x18" 12"x24" 12"x36' 18"x24 24"x36' thicknesses range from 1" to 4 -in 1/2" increments.' TEAR TAPE CARTON . Griptex block is packaged in the new . . . easy open . . . tear tape carton. This easy open carton simply 2ips in half, forming two convenient containers . . . less waste ... less damage . . . less lost time. ,,nvx 4 DfVISION OF COMBUSTION ENGINEERING, INC. iMip'i`*'<iWnVw<Wi<nyM In I * Wl SUPER 711 INSULATING CEMENT ' ^ ^ SUPER 711 Insulating Cement is a. mixture of high temperature mineral fibers specially processed into resilient wool nodules, combined with asbestos and suitable binders to form a high temperature plastic insuiation. Water added according to directions gives a trowelable consistency that Is ready for application on equipment to be operated at temperatures up to 1800" F, t ... WIDE USAGE SUPER 711 is a versatile material for many types of insulatiorfrequirements. Applied over block or blanket insulations, it fills open joints and provides a monolithic surface for whatever type of subsequent finish is specified. Its plastic flexibility permits application directly to regular or curved surfaces - such as valves, fittings, tanks and vessels. .- EASY TO APPLY . ... .. . SUPER 711 has excellent adhesive qualities. Its increased stickability means a better job in less time, from wet to dry. Will not slip or roll under trowel application and may be easily gun applied. This superior .. workability is a result of fine mineral nodules, special manufacturing methods and quality control. _ MAXIMUM COVERAGE - LOW SHRINKAGE .- . .' . .. * * SUPER 711 Insulating Cement assures maximum coverage and low shrinkage. The resilient nodules of mineral fiber do not collapse when mixed with water. See table of Physical Properties for coverage. . RECOMMENDED USES ' . * * ' - ` ' '' . . .' ' boilers;. . : Drums *' " Headers Walls . Economizers - Air Preheaters OVENS. KILNS & DRYERS VALVES & FITTINGS TANKS & VESSELS ` FURNACES Heating Heat Treating Forging Annealing Normalizing TURBINES & PUMPS FAN HOUSINGS DUC'.o 8t BREECHINGS SPECIFICATION REFERENCES . SUPER 711 Mineral F.iber Insulating Cement conforms to ASTM C-195-48; Federal Specification HH-C-168 (Class C); and/or Commercial Standard CS-117 of the U. S. Department of Commerce. . J" 15-783-0450 ^ Vr-^V^T.VVX -510-66CMJ83I ... mriiuML rROBERT Ifcb Or SUPER 711 INSULATING CEMENT * . Service Temperature * Water Ratio . Dry Coverage Material Requirements ' Compressive Strength ' Density (Applied and Dried) Shrinkage (Wet to Dry, by Volume) Thermal Conductivity Reclaimable to Adhesion to Steel (Wet) Adhesion to Steel (Dry) Corrosion Resistance to Steel Shipping Containers (Sewn Closure) 1800F. 12 gals, per 50 lbs. bag 50 sq. ft. 1" thick per 100 lbs. 2 lbs. per sq. ft. 1" thick 45 psi 24 lbs. per cubic foot 15% See Chart 1000F. 6 psi 9 psi- ' Non-corrosive 50 lb. paper bags Tabulated values represent typical performance levels of SUPER 711 Insulating Cement - Trowel Grade. SUPER' 711 Grade Cement consists of the same basic materials that smaller mineral wool nodules are utilized to facilitate application. .' . ' THERMAL CONDUCTIVITY OF SUPER 711 INSULATING CEMENT THERMAL CONDUCTIVITY - (BTU in . / s q . f L . / F . / h r . ) ~rt'j ij^; MEAN TEMPERATURE - F. "vu.> .w y.-'mi. ;n WJl `LSm&i uvLiu.1T iFUrt'te U U^umUiCcJ A'division OF COMBUSTION ENGINEERING, INC. UTILITY THERMAL FINISH CEMENT Utility Thermal Finish Cement is composed of high quality mineral fiber, hydraulic binders, and other suitable materials. Utility combines the flexibility, high temperature resistance, and excellent insulating qualities of uniformly nodulated mineral fiber with the strength, low shrinkage, and smooth finish of hydraulic setting cement. The result is a quick setting, smooth finish, thermal resistant, single layer insulating finish cement. For temperatures up to 120QF. QUICK SETTING ' .. . Utility insulating Finish .Cement develops a smooth, durable, protective finish within a few hours after, application and without the presence of heat. Subsequent drying produces no excessive surface cracking or shrinkage in thickness, and occasional wetting does no damage after hydraulic set. Long drying periods under normal conditions are eliminated. Saves time in applying weatherproofing paint, or other finishes. Jobs are easier to schedule; scaffolding costs are reduced. ONE COAT APPLICATION ** .. Utility is normally applied in a .single layer application. A second layer is needed only when multiple layer thicknesses are specified. Utility is virtually an all-purpose insulating finish cement, designed primarily for use over Griptex block or blanket insulations. Utility is widely used for insulating valves, fittings, heated equipment, and as an anti-sweat insulation for cold water tanks, pumps, etc. - Utility trowels with a good key on block insulation, blanket insulation and insulating cement. It has good wet adhesion to clean steel surfaces, such as valves and fittings. PLEASING APPEARANCE ` . . ' " . Utility dries to a smooth, fight reflectant surface which as an interior finish, requires no further treatment. Utility, "however, is easily painted if desired. Outdoor applications should be weather protected. Low temperature applications require a vapor seal type finish. . . ' EXCELLENT THERMAL QUALITIES . Utility has a "K" factor of .79 at 600F. mean temperature. This excellent insulating value as compared to ' other finish cements is a very desirable advantage when figuring job and operating costs. PHYSICAL PROPERTIES " Service Temperature ` Water Ratio (Trowel Application) Dry Coverage (Trowel Application) Setting Time Material Requirements (Trowel Application) Compressive Strength (Air Cured) * Compressive Strength (@ 1200F.) Density (Applied and Dried) Shrinkage (Wet to Dry) "K" Factor at 600F. Mean Temperature Corrosion Resistance to Steel Surface Treatment Shipping Containers (Sewn Closure MIXING - ' 1200 F. , ' . 7 gals, per 50 lb. bag 37 sq. ft. 1/2" thick per 50 lb. bag . 2 to 4 hours average conditions. . 1.3 lbs. per sq. ft 1/2" thick. 135 psi. 105 psi. . 35 lbs. per cubic foot. Negligible. .79 Btu. . Non-corrosive. Easily painted or weatherproofed /hen required. 50 lbs. paper bag. Utility Thermal Finish Cement should be mixed in a clean mortar box or mixer, using approximately 7 gallons of water per 50 lbs. bag for a good troweling consistency over most blocks, blankets, or insulating cements. Because of the hydraulic binder. Utility should not be mixed with water more than two hours in advance of its application; With cold mixing water (below 60F.) it remains workable up to 4 hrs. STORAGE Store in a cool, dry location until ready to use. Lite k^ifcirir\iwik> a ujii/ *3 hU 1 PEPERMISEAL - THERMAL COAT A DIVISION OF COMBUSTION ENGINEERING, INC ] liwwCSHKSp^ b llsyuifj'iiMi it in m <i <.ljBg"T!Lim'uia'iBBtXiw Kui'wirrjBi.ii wi awMtuwuJ Basically there are three types o' asphalt mastics used in the insulation field. They are usually classified as water emulsion, solvent cutback, or chemical dispersion types. The thinning agent or dispersion chemical determines which basic classification will be given a particular product, and dictates the end use of the resultant product. It is important to know which thinning agent is used to determine the useful qualities of a particularly blended asphalt mastic. The quality and/or type of basic asphalt determines the service temperature of the product involved. , WATER EMULSION ASPHALT MASTICS - v , The water emulsion type of asphalt weather coating such as Thermal Coat, is normally a blend of - ' petroleum asphalt, asbestos fiber and Bentonite clay, emulsified in water. ` " t- ' ... . Water emulsions are primarily used as a breathing mastic, i.e., if suitable pressure is built up beneath its . surface, moisture present will pass through to the atmosphere. However, atmospheric pressure is normally not sufficient to pass moisture back through to the insulation, except, of course, on low temperatury work. In this case, a vapor barrier type mastic such as Duriseal is essential. . -. ' Summer grade water emulsions, becuase of the water present, will freeze and should be protected at all times prior to and during application. Alcohol is usually added to Winter grade emulsions. The amount used determines the resistance - to freezing of the resultant product. Water emulsions should always be . stored and used at temperatures above freezing in any event. A water emulsion that has been frozen is '' useless and will "alligator" if applied. ' . .* . i . * Water emulsions usually are suitable only for trowel application and are used wherever a breathing mastic b ' required. Because they lack tke adhesive qualities and resiliency of a cutback type mastic, they should be mechanically bonded to poultry netting except on extremely small surfaces. They should be used in ' * conjunction with a cutback or dispersion type flashing compound. Water emulsions can only be repaired , with such types of mastics since they do not bond to themselves. It is imperative that they be repaired as soon as possible if a break in the applied surface should occur to insure service life of the product . Thermal Coat may be applied at temperatures up to 200F. and will withstand a maximum temperature of 45QF. after drying. . ' . . .' ' CAUTION: j. `. '' . Water emulsions are soluble in water and should not be applied if there is a possibility of rain washing the ' product within twelve hours of the initial application time. Keep Winter Grade above 20 F. CHEMICAL DISPERSION TYPE ASPHALT MASTICS i, * * ' Chemical dispersion type asphalt mastics, such as PERMISEAL, incorporate a unique combination of the desirable qualities of the water emulsion and cutback types. They normally' consist of petroleum asphalt dispersed in a non-flammable chemical with suitable fillers, blended in one consistency suitable for brush, trowel or spray applications. Containing non-flammable solvents, they are fire-safe for use around open flame, welding torches and similar hazardous job conditions. They have the breathing characteristic of a water emulsion for a period of sixty to ninety days after application. This controlled curing process prevents shrinkage of the surface film and permits trapped moisture to escape. The result is a flexible, blister free, vapor seal type coating of exceptional toughness. A good chemical dispersion product is not affected by freezing and resists most acids and alkalies. However, solubility in water is a factor,' depending upon humidity conditions, for a period of eight to twelve hours or longer after application. The anodizing and rust inhibiting agents contained in PERMISEAL make this product excellent for metal protection purposes. PERMISEAL has a useful service temperature up to 300F. and a maximum of 400F. CAUTION: ' `' Dispersion type mastics should be treated the same as water emulsion types, in that they should not be applied if there is a danger of rain washing within eight to twelve hours of the application time. Under proper temperature and humidity conditions, PERMISEAL will be dry to touch in four hours or less. WEATHER COATINGS AND SEALERS CLASSIFICATION ' WATER EMULSION THERMAL COAT ` CHEMICAL DISPERSION PERM1SEAL Application Method Maximum Temperature Application Temperature Coverage Wet Coverage - Dried Trowel or Flash Coat Brush or Spray Coat * - Reinforcement when required General Use Adhesive Strength Curing for Best Results ' Flame Resistance Freeze Resistance Corrosion Resistance Vapor Resistance . . 1 Packaged Shipping Weight . . ` Trowel _ <50 F. ' 40F. to 200F. 5-6 sq. ft., 1 /4" thick/gal. 5-S sq.ft.. 1/8" thick/gal. ' 1/4" thick wet . Trowel only ' -v "v ` -* Poultry netting Breather type weater coating ` Should be bonded to poultry netting Avoid low temperature and high humidity conditions Non-flammable ' Protect from freezing ,. " Not inhibited - - .. *** , . Will breathe * -/ 5 Gal. 50 Gal. ' . Steel Container . J . 55 lbs. 550 lbs. .' ' Brush-Trowel-Spray 400F. .. 40 F. to 200 F. . 10 sq.ft.. 1/4" thick/gal. 10 sq. ft.. 1/8" thick/gal. 20 sq.fL, 1/16" thick/gal. ' .- 1/4" thick wet . '. . Brush or Spray two 1/8" thick . - wet coats reinforced as req'd. ' Suitable fabric Weather coaling and sealer for . , . ' . insulation, masonry steel, alum. Excellent after curing on clean dry surface Avoid low temperature and high humidity conditions -- Non-flammable . -' Not affected ' Inhibited against rust and corrosion Will breathe during 2-3 month curing period. - then becomes vapor-seal 5 gal. and 54 gat. (plastic liner) steel container ' 45 lbs. 480 lbs. ` T ll t H.1 ___ ___ a bryisioN of combustion engineering, inc. DURISEAL PROTECTIVE COATINQS .-I J 2*:miXy7?Z< wisn^aarm*0O*&+p.\^:r*,*Pi*wy+A*rMm ivarvuwi i >iv;mw Type T-178, '.'*278 Duriseal Protective Coatings are special blends of mastics, combined with asbestos fiber and mineral fillers to provide an excellent sealing material. Applied over masonry settings, they dry slowly to form a black, fire-resistant, air-tight film that is impervious to water exposure, chemical attack and normal abrasion. Duriseal Coatings also are used in conjunction with Detrick Thermal Coat where a flexible flashing compound is required to seal joints around openings, as a calking compound, and for low temperature stack linings to prevent corrosion. " . STANDARD TEMPERATURE GRADES {To 400 F) ' For surface temperatures that will not be operated in excess of 350-400F the Standard Grades are recommended. Standard Type T-178 is made to a semi-viscous, troweling consistency. HIGH TEMPERATURE GRADES (To 700 F) . When surface temperatures will exceed 400F during operation, but not in excess of 700F, Duriseal High Temperatury Coatings should be used. ` .` \ . ` . *` . '' ` ' EASY TO APPLY . ` Duriseal Coatings may be applied over any cool, clean, dry surface, using suitable membrane between spray coats and for patching purposes. Where used, membrane should be lapped 4" at all joints or around patch applications. For ease of application, the best workable temperature range is 50F to 10DF Storage temperature should not exceed 100F.Duriseal Protective Coatings require no thinning. . . COVERAGE - / Material requirements are estimated on wet coverage of approximately 5 to 6 square feet (1/4" thick) per gallon. ' '. CONTAINERS . .. Duriseal Protective Coatings are shipped in 5 or 55 gallon steel containers. CAUTION: ' Surface during application should be above 100F for indoor applications or 130F for outdoor applications. Provide adequate ventilation and do not apply in vicinity of open flame, welding arcs, etc. 5-7S3-0450J. -.-jV..TW XT5i 06R0-"4 837 \?-v. rta a u o I A DIVISION OF COMBUSTION ENGINEERING. INC. 0^ Vir....... PYROSCAT* ?*-,.r?SRWPr!'Wj* US~~rrr FOR FIREPROOFING STRUCTURAI. STEEL Pyroscat is s special formulation of high-temperature aggregates, asbestos fibers, hydraulic binder and other materials. These ingredients are factory blended to a uniform dry mixture that is ready for application after mixing with water at the job site. Pyroscat is adapted to application by spraying, casting and trowelling techniques, depending on job conditions. . . USES: . . ` ' ' Pyroscat provides a lightweight, fire-retardent protective treatment for structural steel columns, beams, tower skirts, LP gas tanks, and other exposed applications in refineries and chemical plants. Pryoscat sets up to `a hard, durable sheath capable of withstanding for hours the 2000F. flame temperatures and high-pressure water streams commonly encountered in industrial fires. RECOMMENDED THICKNESSES: * . ` 'Fire-retardent materials are customarily rated in Hours, based on a given thickness used and on the method of application. For example, fire ratings for steel columns represent the number of hours required for heat from a "standard fire",to penetrate the protective treatment as applied, and to increase the steel column temperature to a critical level (1200F.) The thermal conductivity and heat capacity of a material are of some importance in an ASTM Fire Test. But the ability of the complete treatment to withstand thermal shock without destruction is one of the most significant factors in determining practical fire ratings in industrial installations. . The Pyroscat thicknesses recommended below were determined by physical tests on a series of sprayed, cast and trowelled applications. Tests included direct exposure to 100 psi hose pressure, both before and after subjecting the Pyrosdat treatment to severe flame conditions. .. THICKNESS OF PYROSCAT . 1" . ' 1-3/4" 2" '' APPROX. FIRE RESISTANCE RATING 2 Hours ' 3 Hours (UL-R-3960) 4 Hours ADVANTAGES OF PYROSCAT - ' SAFER WHILE FIGHTING FIRES .. . Many concrete aggregates and common bricks used for fireproofing purposes will spall and shatter when they are heated and subjected to hose stream. Pryoscat remains virtually unaffected after direct flame* exposure and saturation with a 200 psi hose stream. LIGHTER WEIGHT . . . Pyroscat weighs less than 55 lbs./cu. ft. in place, compared to approximately 150 lbs./cu. ft. for conventional concrete fireproofing. Excess dead weight is eliminated. As usually sprayed or trowelled in a protective sheath, Pyroscat weights about 1/10 as much as formed concrete - at equivalent thickness per running foot. . . *A C-E trade name. rsaeMSawawoaa m -- <|||I 11--md \ i l ........... I I I I I bm i 1.1 .ampTM i i II j C-E:REFRACTORIES.'A-DIVISION-OF/COMBUSTION ENGINEERING. INC,-. .r..:;-'.i-V..V^:r2I5:783;0450-U,-:. 1 *-.f. VALLEVlFORGE; PENNSYLVANI A*.1B481 510-660-4837 T;- Jai'LWW 'ADVANTAGES OF PYROSCAT (Continued)' S*PRAY, CAST OR TROWEL . . . Pyroscai especially formulated to permit installation by spray, trowel and costing techniques, depending on local job conditions. No other fireproofing material is as versatile from an application standpoint. Employs conventional supporting materials and placement. Only the one fireproofing material is required no need for subsequent finishing layers nor heavy mastic coatings. DURABLE AND WEATHER-RESISTANT . . . Pyroscat develops great strength from its selected high-temperature aggregates and hydraulic-setting binders. It withstands continued cycles of saturated freeze-and-thaw weathering tests. '. SUMMARY OF PHYSICALPROPERTIES *t Coverage (Trowelled) Material Required (Trowel Application) 1.1 cu. ft./50 lb. bag 45 lbs. per cu. ft. . Air-Cured Weight (After Hydration and Drying) Compressive Strength - Air-Cured ' Compressive Strength After Firing at 1500F. Lineal Shrinkage - Air Cured r Lineal Shrinkage After Firing at 1500F. Density After Firing at 1500<>F. ^ usion Temperature - ' s'* Thermal Conductivity (k) at 1000F..Mean Temp. Setting Time ' ' Mixing Water: 54.5 lbs. per cu. ft. 1650 psi 1.5% ` Less than 1% 1.5% . 39.1 lbs. per cu. ft. ' 2200 F 1.50 Btu . 4 to 6 hours , . .' ', ' .' ' . ,- For Spray & Trowel Consistency For Casting Consistency 3-1/2 Gal. water/50 lbs. bag 5 Gal. water/50 lbs. bag . . Curing: Pyroscat is a cementitious material 'and should be kept moist during the curing period of 72 hours ' longer. wfciHtf&CTureae; A# DIVipfON OF COMBUSTION ENGINEERING. INC. .)'ji.i,t>r>nw*<w>v<rf.~i3ii;Tani.w<ywN wra Jl AIR-CHECK BOILER WALL COATING CEMENT ELIMINATES AIR INFILTRATION PREVENTS HEAT.LEAKAGE SAVES FUEL INCREASES BOILER EFFICIENCY 1 Air-Check .Cement is an asphaltic-asbestos fibre mixture in plastic form for covering the outside of both fire brick and red brick boiler walls. It is also used for pointing up cracks .in boiler walls. Its safe, effective limit of usefulness is 350F. .' Air-Check Cement is tough, rubbery, plastic, easy to apply. A 3/16" thick coat troweled over the surface," dries to a thickness of slightly more than 1/8". It remains semi-plastic even though in service for a number of years. C-E REFRACTORIES.-A-;DIVISI0N-'0F..C0MBUSTI0N:ENG1NEERING,'INC......:.:...^.^^iC-215-783-0450 v..;-^i.yri.^ivALLEY^FORGEPENN5YL'VANjA`M94B1 6.S23 BtlWU B UrBUWl DIVISION OF COMBUSTION ENGINEERING. INC. ALL PURPOSE PLASTIC INSULATION Stic-Tite; and Super Stic-Tite plastic insulations 8re the most versatile insulating materials known. Mixed with water, right on the job. they adhere to any clean surface-and stay on-at all temperatures to 1800 F. They are light, strong and unusually durable. . - ' ' Both' Stic*Tites are a powerful barrier against heat loss. Composed of a special mixture of mineral wool arid diatomaceous earth, the applied and dried material forms a spongy mass of billions of dead air cells, uniform In size and well isolated from each other. This stops air infiltration and resultant heat transmission. ." HOW TO SELECT THE RIGHT THICKNESS - '. Estimate the operating temperature of your installation, (hot face). Follow the hot face temperature ' (bottom of chart) vertically until it intersects the line connecting the cool face (left hand column) or B.t.u. [ loss (right hand column). Use the amount of Stic-Tite indicated on the curve nearest the point of intersection. . ' ' * For example, assume operating temperature is 825F. and a cool face of 139 or 126 B.t.u. loss is desired. Follow the 825 line vertically until it intersects the horizontal 139 and 126 B.t.u. loss lines. The ' intersection -is nearest the 3-1/2" Stic-Tite curve. Therefore. 3-1/2" of Stic-Tite should be used. At the same operating temperature if a cool face of 124 or B.t.u. loss of 95 is desired, the intersection would be nearest the 5" Stic-Tite curve. Therefore, 5" of Stic-Tite should be used. ' - ' . zio. HEATtOSSTHKOUCHINSWATIONB.T.U. Ft* SO. FT. Ft* H*. ,8 8 8 8 ~ HOT FACE TE>*>E*ATUES DEG. FAW. 8 WHERE STIC-TITE IS USED Air Heaters Burner casings Boiler, front, side and rear walls Breechings Cookers _ Drum heads - Elbows F.anges ' F~ed water heaters Furnace and Oven; walls, floofs, roofs Gas generators Hot air ducts - CAN BE USED ON ALL SURFACES Hot air lines Hot piping Hot water heaters Kettles Reaction vessels Regenerator faces Steam heaters Steam pumps Tanks ' Tube doors . Uptakes . Valves and fittings All irregular surfaces Stic-Tite adheres strongly and permanently to metal (special inhibitors help prevent rusting of metal surface), tile, brick, insulating block and blankets or other clean surfaces, hot or cold. It can be used in diflicult places where other types of insulation are unsuitable-on intricate piping, on elbows and flanges,' on slanting vertical or curved surfaces and rounded corners. Stic-Tite provides a monolithic, seamless, jointless covering which can be troweled perfectly smooth for appearance. \ J ^.-VC-E REFRACTOR I ES"A-;DiyiSlON.pF.-COMBUSTION EN GIN EE RIN G.:l N CrVj-;r-^l 3 V*:1 * ................r^rrW'^ ** a k$-nta * ji h-183^0450^: ^ TVk5inw/nY^f**-'- *. * * `EXCELLENT ADHESlON-HcALLY "STAYS ON" 8 . Stic-Titc adheres permanently without lifting bff or shaking,loose even when subjected to sever vibration, abrasion or impact. STOPS HEAT LOSS The spongy moss of dead air cells checks air infiltration--prevents heat loss. Since dry Stic-Tite does not shrink or form cracks, the high insulating efficiency is never impaired. ' EASY TO APPLY '* ' .. .. Stic-Tite, mixed with the proper amount of water, forms an easily workable, plastic mass which can be troweled or safely applied with the bare hands. The usual practice is to apply first a roughing coat over the t l ; area to be covered, then trowel smooth around joints, over the surface and elbows, curves, etc. , LARGE COVERAGE . . ^ * ` Since Stic-Tite dries with practically no shrinkage (an inch of Stic-Tite applied wet remains practically an . inch thick when dry), less is required to provide sufficient insulating thickness. Mixed and applied as directed, 100 lbs. of the material cover45 sq. ft. with a 1" thick layer. - - ,-r;, ' _ . ` - CAN BE REUSED . ` \ . If used at temperatures below 900F., old Stic-Tite can be removed from equipment, crushed, mixed with clean water .and reapplied like-new Stic-Tite. This makes equipment repairs less costly since the insulation ' can be saved. Reclaimed Stic-Tite is equal to the new product in insulating efficiency, adhesion and ' . plasticity. ' . - * SAVES LABOR AND MATERIALS . ` Stic-Tite is so easy to apply on all types of regular and irregular surfaces and over other insulations that ' labor cost is very low. Skilled men are net needed. Since Stic-Tite adheres so strongly, reinforcing wires * : and other supports are unnecessary when ;,:sed up to 1-1/2" thick. .. < CONVENIENT PACKING * .' . ' Stic-Tite is shipped dry in heavy, lined, dustless paper bags containing 25 lbs. and 50 lbs. each. It does not deteriorate in dry storage--can be kept indefinitely if dampness or wet places arc avoided. ' HOW-TO APPLY / , . . 1. Each 50# bag should be mixed with 12 gallons (100 lbs.) of fresh water. . 2. After thoroughly mixing, Stic-Tite can be applied immediately, but better results can be obtained by allowing it to soak for at least a half hour or longer. . . ` 3. All surfaces to be covered should be free of paint, dust, dirt and grease. 4. Roughing coats can be applied by hand or trowel or combination of hand and trowel. - 5. If hot surfaces are to be insulated with Stic-Tite, the material should be spotted in place with a trowel and dragged down to a feather edge. The spotted material will dry quickly and then a rough ' coat about 1" thicx can be applied over and between the spots. . .. 6. On cold surfaces for covering up to 1-1/2" thick, after being mixed according to directions on the bag, Stic-Tite should be applied by spreading it over the surface to as even a thickness as possible. After the rough coat has dried out, a finish coat up to 1/2" thick can be applied over the rough surface and finished with a trowel tr- a smooth, attractive finish. Stic-Tite can be used up to 1-1/2" thick without reinforcing. 7. For covering over 1-1/2" thick, apply a rough coat about 1" thick. When rough coat is dry apply another 1" coat and continue unlit desired thickness is obtained. Esch coat should be dried before additional coats are applied. Prior to application of finish coat, we recommend reinforcing with #20 gauge 2" mesh chicken wire. 8. 'Finish coats should be applied from 1/4" to 1/2" thick, troweled to a smooth, hard finish. Where desired, Stic-Tite finish can be painted. Best results are obtained by painting with a glue sizing and paint over this. . 9. If more Stic-Tite is mixed than can be used, the left over material can be laid aside and remixed with water at a later date when it is required. HEW service i umpcraiure 12QCTF. -` 'Water Ratio (Trowel Application) 7 gals, per 50 lb. bag. Dry Coverage (Trowel Application) 37 sq.ft. 1/2" thick per 50 1b. bag ,Setting Time * 2 to 4 hrs. average conditions. Material Requirements (Trowel Application) 1. 3 lbs. per sq.ft. 1/2" thick. Compressive Strength (Air Cured) Compressive Strength (@1200F.). 135 psi. 105 psi. ' .' '. Abrasion Factor (Air Cured) 98 seconds (MHD Method 102). Density (Applied and Dried) 35 lbs. per cubic foot. Shrinkage (Wet to Dry) Negligible. . ` "K" Factor at 600 F. Mean Temperature . 79 Btu. . ' Corrosion Resistance to Steel. . Non-corrosive. ... . ._ Surface Treatment " ... ,, . Easily "painted, or weatherproofed/". .JT when required. ' -*_.* Shipping Containers (Sewn Closure) "50 lb; paper bag. ' - - - Mixing '. Utility Thermal Finish Cement should be mixed in a clean mortar box or - mixer, using approximately 7 gallons of water per 50 lb. bag for a good troweling consistency over most blocks, blankets, or in sulating cements. Because of the hydraulic binder. Utility should not be mixed with water more than two hours in advance of its application. With cold mixing water (below 60Fl, r*it remains workable up to 4 hrs. STORAGE . 'T-.V Store in a cool, dry location-"' until ready to use. .. _ . Utility Gunned on Balloon Flue'. _ . r* "e-tfr*" REFRACTORY Sc INSULATION CORPORATION 625 ILLINOIS AVE. AURORA, ILLINOIS PORT KENNEDY PENNSYLVANIA UTILITY THERMAL FINISH CEMENT Jtility Thermal Finish Cement is composed of high quality mineral fiber, hydraulic binders, aiid other suitable materials. Utility combines the flexibility, high temper ature resistance, and excellent insulating qualities of uniformly nodulated mineral fiber with the strength, low shrinkage, and smooth finish of hydraulic setting cement. The result is a quick setting, smooth finish,, thermal resistant, single layer insulating- finish cement. For temperatures .up - to 1200F. . ' QUICK SETTING , * ' I f #j Utility Insulating Finish Cement develops a smooth, durable, protective-finish within a . _ few hours after application and without the presence cf heat. Subsequent drying produces no excessive surface cracking or shrinkage in thickness, and occasional wetting does no damage after hydraulic set.. Long drying periods under normal conditions are eliminated. Saves time in applying weatherproofing, paint, or other finishes. Jobs are easier to schedule; scaffolding costs are reduced. ONE COAT APPLICATION Utility is normally applied in a single layer application. A second layer is needed only when multiple layer thicknesse s. are specified. Utility is virtually an all -purpose insulating finish cement, designed primarily for use over Griptex block or blanket insulations. Utility is widely used for insulating valves, fittings, heated equipment, and as an anti-sweat insulation for cold water tanks, pumps, etc. # . Utility trowels with a good.key on block insulation; blanket insulation and insu- Tating cement. It has good wet adhesion to clean steel surfaces, such as valves and fittings.' . '` . .. PLEASING APPEARANCE ' * ` '* ' V - '* ' . ` Utility dries to a smooth, light reflectant surface which as an interior finish, requires no further treatment. Utility, however, is easily painted if desired. Outdoor applications should be weather protected. Low temperature applications require a vapor.seal type finish. - EXCELLENT THERMAL QUALITIES - Jtility has a "K" factor of . 79 at600F.mean temperature. This excellent insu lating value as compared to other finish cements is a very desirable advantage when figuring job and operating costs. t W j i ha t I 4 <~l > 4 W A W I . ^u.iut \^uU unliun V.UIU UiVMIiUH yjSnfer. SUPER 711 INSULATING CEMENT ; ^/^jYowelor GunGrad* -i>- &?:?$&' SUPER 7.11 Insulating Cement is a mixture of high temperature mineral fibers specially processed into resilient wool nodules, combined with asbestos and suitable binders to form a high temperature plastic Insulation. Water added according to directions gives a trowelable consistency that is ready for application onequipment to be operated at temperatures up to 1800F. WIDE USAGE , SUPER 711 is a versatile material for many types of insulation requirements. Applied over block or blan ket insulations, it fills open joints and provides a mono lithic surface for whatever type of subsequent finish is specified. Its plastic flexibility permits application directly to regular or curved surfaces -- such as valves, fittings, tanks and vessels. EASY TO APPLY '. SUPER 711 has excellent adhesive qualities. Its increased stickability means a etter job in less time, from wet to dry. Will not slip or roll under trowel appli cation and may be easily gun applied. This superior workability is a result of fine mineral nodules, special, manufacturing methods, and quality control. MAXIMUM COVERAGE - LOW SHRINKAGE ` ' SUPER 711 Insulating Cement assures maximum coverage and low shrinkage. The resilient nodules of mineral fiber do not collapse when mixed with water. See table of Physical Properties for coverage. RECOMMENDED USES BOILERS Drums Headers Walls . Economizers ' Air Preheaters FURNACES Heating Heat 1Y eating Forging * Annealing Normalizing . OVENS, KILNS & DRYERS VALVES &. FITTINGS TANKS &. VESSELS . TURBINES & PUMPS FAN HOUSINGS DUCTS &. BREECHINGS -SPECIFICATION REFERENCES JPER711 Mineral Fiber Insulating Cement conforms to ASTM C-195-48; Federal Specification HH-C-168 (Class C}; and/or Commercial Standard CS-117 of the U. S. Department of Commerce. _______. Mnv 1 Q Service Temperature . Water. Ratio Dry Coverage - * Material Requirements Compressive Strength Density (Applied and Dried) Shrinkage (Wet to Dry, by Volume) Thermal Conductivity . Reclaimable to ' .* ' Adhesion to Steel (Wet) - Adhesion to Steel (Dry) 7 Corrosion Resistance to Steel * Shipping Containers (Sewn Closure) % 1800F. 12 gals, per 50 lb. bag 50 sq.ft. 1" thick per 100 lbs. 2 lbs. per sq.ft, l" thick 45 psi 24 lbs. per cubic foot . 15% See Chart ' `1000F. ' 6 psi ~. 9 psi ; lion-corrosive . : 55 lb. paper bags . .. Tabulated values represent typical performance levels of SUPER 711 Insulating Cement - Trowel Grade.. SUPER 711 "Gun'1 Grade'Cement consists of the same basic materials that smaller mineral wool nodules are utilized to facilitate appli cation. ' -- . '' ' j THERMAL CONDUCTIVITY OF SUPER 711 INSULATING CEMENT 200 400 600 800 1000 1200 . 1400 . MEAN TEMPERATURE - F. " '' REFRACTORY 8c INSULATION CORPORATION 625 ILLINOIS AVE. AURORA, ILLINOIS V PORT KENNEDY ' PENNSYLVANIA V.UU1 UUHIIUU A. Surface Preparation . .. 1. Remove dirt, scale or loose paint from the surface to be treated, then apply rust preventative paint or coating when specified. 2. For trowel applications to columns and beams,, form 3/8" rib lath (or paper-backed lath) to box-in the member. Apply rib`lath with ribs turned in and spanned from flange to flange. On members 14" and larger, first weld 1/ 4" rods across the flanges approximately 12" to 18" on centers to provide additional support for the lath. Secure the lath in place with wire or bands. For gun application, .use 2x2 #16 paper-backed-lath such as Steeltex. - a) ' Provide 2" firestops on columns at 8' to 12' intervals (or as other wise specified). Form the metal lath into a horizontal shelf ex tending to and supported at the web. Apply Pyroscat 2" thick in the opening. Provide similar stops at the top elevation of thefire- proofing. -\ b) . - Plasterer's corner bead may be wired to the metal lath, forming and supporting it to attain the total Pyroscat thickness specified. Corner bead shall be of the type having open-mesh legs to facili- tate complete filling of the corners. The corner bead may be spaced the proper distance from the flanges by means of corner clips, rods, studs; or Pyroscat may be spotted-in to space the corner bead at specified fireproofing thickness. B. " Application of Pyroscat ' 1. Mix Pyroscat to recommended consistency with clean, fresh water, before application. Refer to mixing instructions on the bag and use no more water than called for. Mix Pyroscat to a homogeneous plastic .. mass; avoid over-mixing, particularly with mechanical mixers. a) Apply Pyroscat well into the metal lath, installing approximately 1/2 the total thickness in the scratch coat. Leave the first coat rough or scratch the surface. ` b) On the underside of beams, the application may be in three coats. Apply a thin scratch coat first to improve adhesion. . . c) If corner bead was not applied previously, wire it in place when the scratch coat has set. 2. Letthe scratch coat harden until well set (4 to 6 hours or longer), then double-back with the finish coat. Apply it flush with the corner bead. Sponge-float the surface to a textured finish or as otherwise specified. a) When application of the finish coat is deferred overnight or longer, wet down the scratch coat thoroughly before proceeding with th finish coat* * Pyroscat is a cementitious material; to develop its strength, keep it moist . * for 72 hours or longer. Depending on atmospheric conditions when applied, ' the required water retention may be accomplished with wet burlap, periodic . ' " , water spray or a hydrostatic (resin-base) sealer. 2. Following the curing period and when visual moisture has dried, apply a . suitable flashing material at all intersecting joints and exposed endB of members treated (Duriseal T-178 Coating). . .. . ' 3. Pyroscat may be painted with (1) masonry paint, (2) two coats of asphaltbase aluminum paint, or (3) other finishes as specified for operating conditions involved. (Note: When conventional masonry paint of the hydrating-type is used, wet down the Pyroscat before painting to insure proper . hydration). . - " . ALTERNATES FOR TOWER SKIRTS (VERTICAL) . A-2 Attach a layer of 1" x ln square mesh reinforcing, positioned l" away from the - skirt, i. e., at the approximate center of the fireproofing thickness specified. a) - Trowel or gun Pyroscat solidly through openings in the square mesh, bringing the scratch coat out approximately 1" thick. Start at the bottom of the skirt and work upward. Leave the surface rough, or scratch it when trowel applied. ' . ' ' b.) Screed strips may be attached temporarily over the Square mesh reinforc ing, to accurately gauge the thickness of the second layer. c) When fireproofing is applied to skirts of heated vessels while they are in operation, heat conducted to the skirt may prematurely dry the initial layer * of Pyroscat. Wet the first coat thoroughly, particularly at the top, before applying the final layer. * . ALTERNATES FOR HORIZONTAL TANKS A-2 * Bolster bars are preferred for anchorage of the reinforcing mesh. The bolster bar selected would have legs extending from the tank surface approximately one-half of the total thickness of Pyroscat to be applied. Form the bolster bars to fit the tank curvature, then weld or wire in place circumferentially approxi mately 3` on centers. Wire the reinforcing mesh to the bolster bars. C-3 When tanks so fireproofed are to be operated below ambient temperature, suit able vapor-sealingtreatmentis recommended after the Pyroscat has been cured, dried and flashed. REFRACTORY & INSULATION CORPORATION 625 ILLINOIS .AVE. AURORA, ILLINOIS . - PORT KENNEDY PENNSYLVANIA uju.iminjj.1k f V M WifcffcilWtl Pyroscat is a special formulation of high-temperature aggregates, asbestos fibers, hydraulic binder and other materials. These ingredients are factory blended to a uniform dry mixture that is ready for application after mixing with water at the job site. 'Pyroscat is adapted to application by spraying, casting and trowelling techniques, depending on job conditions. USES: . Pyroscat provides a lightweight, fire-retardent protective-treatment for structural steel columns, beams, tower skirts, LP gas tanks, and other exposed applications in refineries and chemical plants. Pyroscat sets up to a hard, durable sheath capable of withstanding for hours the 2000F. flame temperatures and High-pressure water streams commonly encoun tered in industrial fires. -' RECOMMENDED THICKNESSES: \ Fire-retardent materials are customarily rated in Hours, based on a given thickness used and on the method of application. For example, fire ratings for steel columns represent the number of hours required for heat from a "standard fire" to penetrate the protective treatment as applied, and to increase the steel column temperature to a critical level (1200 F;). The thermal conductivity and heat capacity of a material are of some impor tance in an ASTM Fire Test. But the ability of the complete treatment to withstand thermal shock without destruction is one of the most significant factors in determining practical fire ratings in industrial installations. The Pyroscat thicknesses recommended below were determined by physical tests on a series of sprayed, cast and trowelled applications. Tests in cluded direct exposure to 100 psi hose pressure, both before and after subjecting the Pyroscat treatment to severe flame conditions. Thickness of Pyroscat 1" 1-3/4" u Approx. Fire Resistance Rating 2 Hours 3 Hours - (UL-R-3960 4 Hours ADVANTAGES OF PYROSCAT Safer While Fighting Fires .... Many concrete aggregates and common bricks used for fireproofing purposes will spall and shatter when they are heated and subjected to a hose stream. . Pyroscat remains virtually unaf fected after direct flame exposure and saturation with alOOpsihose stream. May, 1964 *An R It I trade name. * * Lighter Weight. ... Pyroscat weighs less than do auo. , w... _ tp approximately 150 lbs./cu. ft. for conventional concrete fireproofing, bxcess r dead weight is eliminated. As usually sprayed or trowelled in a protective sheath, Pynoseat weighs about 1/10 as much as formed concrete - at equivalent thickness per running foot. * .. Spray, Cast or Trowel.... Pyr.oscatis speciallyformulatedto permit installation by spray, trowel and casting techniques, depending on local job conditions. No . other fireproofing material is as versatile, from an application standpoint. Em ploys conventional supporting materials and placement. Only the one fireproofing material is required - no need for subsequent finishing layers nor heavy mastic coatings. ' ,^ Durable and Weather-Resistant.... Pyroscat develops great strength from its selected high-temperature aggregates and hydraulic-setting binders. It with- ` stands continued cycles of saturated freeze-and-thaw weathering tests. SUMMARY OF PHYSICAL PROPERTIES: Coverage (Trowelled) . . . 1.1 cu. ft./50 1b. bag Material Required (Trowel Application) * 45 lbs. per cu. ft. Air-Cured Weight (After Hydration and Drying) Compressive Strength - Air-Cured 54. 5 lbs. per cu. ft. 1650 psi Compressive Strength After Firing at 1500F. Lineal Shrinkage - Air Cured ' Lineal Shrinkage After Firing at 1500F. 1.5% Less than 1% 1.5% Density After Firing at 1500F. 49.1 lbs. per cu. ft. Fusion Temperature 'o Thermal Conductivity (k) at 1000 F.Mean Temp. 2200 F 1. 50 Btu Setting Time 4 to 6 hours Mixing Water: For Spray & Trowel Consistency 3-1/2 Gal. water/50 lb. bag For Casting Consistency 5 Gal. water/50 lb, bag Curing: "Pyroscat is a cementitious material and should be kept moist during the curing period of 72 hours or longer. . REFRACTORY & INSULATION CORPORATION 625 ILLINOIS AVE. AURORA, ILLINOIS PORT KENNEDY PENNSYLVANIA 1L' 'V. . .SL*LA7IKC BLOCK ------- f 1=) f'12`'Insulating Block (R) ,* Vw *19 Insulating Block (R) ' . vi) Griptex* Mineral Wool Block (D) (=:) Kaiser M. Block (D) C-E START ESTIMATED STOP PERCENT AND . TYPE OF ASBESTOS *" CONTAINER 1963 1966 4.5(A) Cardboard Carton 1963 1966 4.6(A) Cardboard Carton 1964 ' 1972 . 2.0(C) Cardboard Carton Unknown 1971 2.0(C) Cardboard Carton INSULATING CEMENTS ,(n) .Stic-tite* (R) 1963 X 6/27/72 - 38.6-42.2(0 50 lb bags <D> (a) Super Stic-tite (R) . ,r 1964 1964 8/30/72 6/27/72 9.89-10(0 50 lb bags * o `. . 1964 8/30/72 (a) Super Finish Stic-tite_(R) 1963 6/27/72 11.5-13.1(0 50 lb bags (m) Super Finish (R) 8/10/65 1/10/68 14.2(C) 40 lb bags Cm) Super 711(D) * . 1964 ` 6/27/72 13.7(C) 50 lb bags (n Kaiser Mineral Wool Cement (D) 1964 1971 13.7(C) 50 lb bags Cm) Utility Thermal Finish Cement (D) 1964 2/28/72 4.75(0 50 lb bags ^m) Casing Cement (D) 1964 1969 4,9(0 50 lb bags, m) MED Finishing Cement- (D) 1964 1968 68.03(C) 50 lb bags m) Pyroscat* Fireproofing Cement (D) 1964 6/8/72 3.0(C) ... - 50 lb bags m) Eilite Insulating Cement (D) 1964 1968 9.1(C) . . 50 lb.bags m) A-1199 Insulating Cement (R) m) SDK 50 (R) 1963 ' 1963 1966 1966 _ 43..4(C) ' 0.4(A) . ' 50 lb bags 50 lb bags m) Buck Stay1 Cement A-1360 (R) 1965 1966 0.8(A) 50 lb bags m) Castablock* (R) 1965 1/19/66 1.2(A) 50 lb bags a) Stirrup Cement (R) ' 1965 1966 42.7(C) 50 lb bags a) Calcrete 30 (D) 1964 1970 7.8(C) . 50 lb bags ISCELLAKEOUS PRODUCTS ' 3) Asbestos Rope (D) 1) Permiseal (D) (fibers in emulsion) 3) Weatherkote (R) (fibers in Emulsion) ^Thermal Kote since 1976) 1964 1964 1963 1965 1975 1977 100.00(C) tied 100 ft coils 1/2 to 3" in diamete: Anprox. 5 4 54 gal. 3.0(C) steel containers Approx. 5, 30 6 55 gal. 3.0(C) steel containers Annrox. 5, 30 & 55 gal. MISCELLANEOUS PRODUCTS .(m) Block Stick (R) ' (in) Gunisul Cm) Mix A (R) (m) Fibrous Adhesive (D) (o) Hytempt Flexible Compound (R) (m) Expansion Joint Material (R) C-E START 1963 ESTIMATED STOP 6/28/72 PERCENT AND TYPE OF ASBESTOS 22..0(C) 1963 1963 1964 1963 1966 6/27/72 1965 1972 ^ Approx. 1.0(A) 6.0(C) 13.1(C) . 30.0(C) 1963 1966 100.0(A) CONTAINER 6 gal. steel ' containers 50 lb. bags 40 lb. bags Steel container 5 gal. steel containers 25 lb. bags INSULATING REFRACTORIES (m) Light Wate 22 (W) 1969 6/26/72 10.0(C)/ 27.0(C) 50 lb. bags r IISCELLANEOUS PRODUCTS DISTRIBUTED BY C-E :d' K-12 Calcium Silicate Block :d) K-12 Calcium Silicate Pipe Covering d) K-20 Insulating Block d) Kaylo 10 Calcium Silicate Block d) Kaylo Calcium Silicate Pipe Covering ' d) Kaylo 20 Block . d) J-M Thermobestos Calcium Silicate Block d) J-M Thermobestos Calcium Pipe Covering d) J-M Asbestos Cloth J-M Asbestos Gasketing 1963 1963 1963 1963 1963 1963 1963 1963 1963. 1963 1969 1969 1969 1969 1969 ' 1969 1969 1969 1969 1969 Unknown Unknown Unknown Unknown Unknown Unknown ' Unknown Unknown Unknown Unknown e; RJ - R & I - Port Kennedy, Pennsylvania D) - Detrick - Aurora, Illinois *J) - Walsh - St. Louis, Missouri a) - manufactured d) - distributed 3) - containing chrysotile A) - containing amosite *) - Trademark '