Document 6b1Dmke8L555p4J153jeY9OZg
/1
its
6
n
6
o e
c vO o
UNITED STATES GYPSUM GOMPANY
GENERAL APPLICATION DETAILS
Preparation and Other Requirements of Roof Decks and Sur faces to Receive All Types of U S G Asbestos Cement Shingles
Construction of roof docks and provisions for satis* factory surfaces to receive USG Asbestos Cement Shingles are not included in the individual USG Asbestos Shingle Application Instructions. Therefore, the following general provisions should be carefully checked by the applicator before beginning work.
Shingles shall not be applied on roofs having a slope of less than 4 inches to the foot.
Minimum Pitch
'
American Method Asbestos Cement Shingles--4" in
12". Hexagonal and Dutch Lap Asbestos Cement
Shingles--5" in 12".
.
Nails
Nails for applying the shingles directly to roof decks shall be galvanized or copper, barbed. I1/* inches long for new work, and with heads not less than inch in diameter.
Nails for applying shingles over wooden shingles
shall be galvanized or copper, barbed. 2 inches
long, and with heads not less than % inch in di ameter.
Nails for fastening down waterproofing felt shall
be galvanized, barbed. 1 inch long, and with heads
not less than 5/j inch in diameter. The discs or caps shall be not less than l1/* inches in diameter and shall be flat. Bell or cup shaped caps should not be used.
Note:
Nails for sheet metal work shall correspond to the type of sheet metal used.
New Wood Decks
Decks should be constructed of matched tongue and groove, well seasoned or treated lumber of uniform thickness. Boards should be dry. smooth, and free from wide cracks or large knot holes, and should be laid close together. Boards should have solid bearings at ends and be securely nailed to each rafter with not less than two face nails, heads to he driven flush with the surface of the boards.
Before applying the shingles, the roof surface shall be swept dean. All loose boards shall be se curely nailed in place and all knot holes or other
openings or cracks 1/4 inch dr more in width shall
be smoothly covered with sheet metal securely nailed in place on one side only. All nails or other projections that might pierce the shingles shall be removed.
Shingles shall not be applied when rain is falling, . nor during weather cold enough to prevent the
work being done in the proper manner.
All material shall be housed or protected from the elements or other sources of damage. Shingles shall be stacked on end on planks off the ground.
Over the entire surface to be covered by shingles,
lay one thickness of
15-pound Asphalt Water
proofing Felt lapping
all seams at hip. ridge
and valley 12" and all
other seams 4". Nail
felt sufficiently to hold
in place until shingles
are applied.
Proper pitch for the shingles at the eaves is obtained by applying a cant strip l/^xP/j" Hush and parallel with the eaves. See Detail No. 1.
FLASHING--GENERAL
All intersections of roofs with vertical surfaces of
every land and all openings in roof surfaces should
be flashed with sheet metaL L e., copper, zinc, lead
or tin. The method should be base and counlerflash- ~
ing--eee detail No. 7, 8 and 9. Base flashing should
be not less than 4" high and should extend not less
than 4" out on the roof. Counterflashing should
turn down over base flashing not less than 4".
When attached to masonry walls counterflashing
should extend back into raggle joints not loss than
1" and be securely wedged in place. Raggle joint
should be completely pointed up with plastic ce-
menL Step-flashing should be used where vertical
surfaces occur on sloped surfaces. Step-flashing
should be formod of separate pieces of shoot metaL
properly inserted in raggle groove and lapped
3" but not less than 2". Step-flashing should not be
soldered.
.'
960 tiOOdOI
i
detail No. 3. Embed shingles that border on val
ley in
Asbestos Slaters* Cement
When two unequal slopes meet the steeper side
will send down a greater quantity of rain water at
a greater pace than the other side. Unchecked, the
water may back up under the shingles, beyond the
edges of the valley flashing.
To act as a check, an inverted "V~ crimp should
be formed in the valley. See detail No. 4, 5 and
6. When laying the valley it is a good plan to
place a wood core under the inverted "V" to pre
vent crushing while the roof is being laid.
No. 2
Valley Flashing
Apply sheet metal valleys to provide an opening not less than 4" wide. The proper width shall be determined as follows: Starting at the top width of
".4 increase the width 1" for every eight feet of
length of the valley. Flashing pieces should be full length sheets and of sufficient width to cover the open portion of the valley and extend up under the roof shingles as far as possible without being pierced by the nails holding the shingles. Flashing should be constructed of one piece with no longi tudinal seams in the valley. Cross seams at the ends of the valley units should be locked * and soldered. Edges should be turned back Vz" and
held in place by cleats spaced not more than 10"
apart and nailed to' the deck with two nails. See
VALLEY FLASHING
No. 3
OP 00*1 0 9 6 2
No. 4
No. 5 [31
No.6
APPLICATION
Chimney Flashing
"
Step-Dashing, as previously described, should he
installed. If the chimney is located on a pitched
rool and will receive on the high side the Dow of
water from the slope of the roof, a "saddle** or "gus
set** or "cricket" should be formed to direct the Dow
of the water around the chimney. See detail No. 8.
CPOO'J 0 9 6 3
Cap Flashing to lap a min. of 2
Flashing to extend up under shingles and up under cap flashing a minimum of 4
Metal covered saddle oriricket
FLASHING FOR CH1MNY~0NSLOPE OF ROOF
No. 8
FLASHING UNDER
DORMER WINDOW
SILL
Siding
Metal Flashing
No. 9
Dormer Window Flashing
Where dormer windows rest on the roof, construct a metal pan and insert to extend 4" down the root
and 2" up the side of the studs.
On new roois. omit the roof boards on the dormer overhang until the main courses of the shingles are applied. On old roois. provide a space oi ", in order to secure the proper clearance for the ap plication of the new shingles Oil the main roof at points where the dormer overhang occurs. See de tail No. 10, 11, 12 and 13.
Perspective of" Flashing Pan
Shin No. to
DETAIL OF METAL PAN FOR DORMERS RESTING ON ROOF
[]
No.ll
around the nails and strike the ollseL This will cut or draw the nails. Remove the old shingle and se cure a new one in place by driving one nail through a hole punched in the center of the shingle. Then slip a small piece of copper over the nail head and bend slightly to hold in place. See detail No. 14.
No. 12
METHOD OF REMOVING AND REPLACING BROKEN AMERICAN METHOD SHINGLES
No. u
USG Hexagonal Shingles
With hexagonal shingles, straighten up the storm anchors as shown in detail No. 15. Slip the ripper up under the broken shingle and hook around the nails, then strike the offset with a hammer and the nails will be cut off or drawn. Place a small piece of sheet copper over the storm anchor at "C" and nail it to the rooL Notch new shingle as shown, slip it in place and then bend down the storm anchors.
t j9 6 0 tiO O J'J '
REMOVING AND REPLACING BROKEN SHINGLES
No. 15
Little or no maintenance is required on asbestos cement shingles. Occasionally shingles become broken and must be replaced.
U S G American Method Shingles
To remove USG American Method Shingles easily, slip a nail ripper under the broken shingle; hook it
USG Dutch Lap Shingles
With Dutch Lap Shingles, bend up the storm an chors at "A" and "B". See detail No. 16. Shatter the broken shingles by a hammer blow on the cen ter. then remove the pieces. Insert the ripper under overlaying shingle and remove or cut off nails "C".
[S]
METHOD OF REMOVING AND REPLACING BROKEN DUTCH LAP SHINGLES
No. 16
"D" and **E". Insert a new storm anchor in a new
shingle. If it has been found that the old nails can
not be withdrawn, notch the new shingle at nail
holes as shown. Slide the new shingle into place
over storm anchor at "B", raising overlaying shingle
'in nllrrmr msprtmn at **F" of new storm anchor in
new shingle, then bend dowiTsfbnn anchors at~"A".
"B" and "F." completing the job.
RIDGES AND HIPS Ridge and. Hip Roll Construction
Apply one l"x 2" furring- strip, edgewise, centered
on ridge or hip. The furring strip shall'be high enough to give proper support to the ridge or hip roll but not raise it off the surface of the shingles. Project the strip 1" beyond the ridge or lower ends of the hips* The main body shingles on each side of the ridge or hip should be cut to fit snugly against each side of the furring strip. Cover the ridge or hip with a narrow strip of waterproofing felt, projecting the felt out on each side and under the adjacent shingles. See detail No. 17.
' Application of Ridge or Hip Roll
The first section of the ridge or hip roll is 4et at the lowest point and secured with two nails, one near the lower end. and one at the upper or small end. At the latter point, nail through a copper ridge or hip roll clip, nail them at the upper end.and then all following sections of ridge, or hip roll are placed as follows: Set them in position against the ridge or hip roll clip, nail them at the upper end and then bend the copper clip down into position as shown. The lower end of the hip may be filled with Asbestos Slaters* Cement or a piece of shingle cut to fit
On ridges, start the application of the ridge or hip roll at the end opposite the direction of prevail ing winds or storms; on dormers, start at the iront .and on hips at the lowest point
CPOOH 0 9 6 5
DETAILS OF APPLICATION FOR* BOSTON FUDGE OR HIP
No. 19
No. 20
No. 21
Boston Ridge or Hip
Apply two l"x2" furring strips, flatwise, one on each side of the ridge or hip. Cut main body shingles to
fit against the sides of the strips. Then apply a 6"
strip of waterproofing felt and lap the ridge or hip shingles over it Allow a 2' head lap and 7" weather exposure on the shingles. Alternate or "weave" the long edges of the shingles and secure each with two nails. Point up all Joints with Asbestos Slaters' Cement. See detail No. 19 and 20.
-
Mitred Hip
n
When this construction is used the hip should be ^
reinforced with extra flashing strip of waterproofing
felt, or preferably, sheet metal (copper). Shingles **
must be carefully mitred and applied in a bed of ^
Asbestos Slaters' Cement and carefully pointed ^
up with the same material. See detail No. 21.
Cutting and Punching
.
USG Asbestos Cement shingles may be cut by scor ing with a sharp pointed awl and then breaking
m
Score shingle with sharp toot
Place shingle over straight edge and strike with fist or hatchet
METHOD OF CUTTING SHINGLES
No. 22
Notching Attachment
Punch for
face nails
No. 23
ASBESTOS SHINGLE CUTTER
Adjust
/here for thickness of shingles
over any square edged surface. See detail No. 22., Holes may be punched with a sharpened nail set or bored with a hand drilL
To make straight cuts, score thp shingle with the point of a chisel or hatchet blade. Then place it over a straight-edge and strike the overhanging part several blows with a hatchet or the fist. (A saw may also be used ior cutting but it involves unnecessary labor.) For circular or angular cuts, place the. shingle on a firm, smooth surface and punch holes in it with a pointed nail punch along the lines' to be cut
Applicators should use an asbestos shingle cutter (see illustration No. 23) to cut and punch holes in shingles quickly, easily and accurately.--- -- -
Old Wood Shingles
Before applying USG Asbestos Cement Shingles, all badly warped wood shingles should be removed and replaced with new shingles, inserted to provide a, suitable anchorage for nailing USG Asbestos Cement Shingles. Curled shingles should be split and the comers securely nailed down. See detail No. 24.
Valleys should be filled to the level of the surface ~ of the wood shingles with boards oi the -correct
thickness before applying new valley construction. See detail No. 25.
Gables
REROOFING
Old Wood Decks
All rotted, splintered or weakened roof hoards should be removed and replaced wiih new roof boards. Draw down any roof boards that have warped or curled by renailing.
Old shingles should be removed along overhang ing gables and replaced with boards 4 inches~wide of proper thickness to make the top surface level with the surface of the wood shingles. If desired, preformed sheet metal strips may -be used, nailed
on 6" centers t/j" from the inner edge. See-'detail
No. 26 and 27.
.9 6 0 00 I
No. 25
18]
No. 27
Old Roofs
Due to settling oi the building, old rools may be out oi square. It is important when such conditions are encountered that the measurement lines to guide application are at right angle to the eaves line.
At the eaves allow only Vz* overhang instead of l", as when applying shingles directly to new roof decks.
Bevel Stripping
Where old wood shingles are in poor condition and the weather exposure of the new shingle does not
coincide with that of the old shingles, apply 9/i"x 4"
bevel strips to form even roof surface and to pro* vide suitable nailing surface for the USG Asbestos Cement Shingles. See detail No. 28.
Cant Strip
Remove existing eavo or cornice moulding and replace it (or apply new moulding) so as to project
V4" above the roof boards or old shingles from
which the edges have been cut See detail No. 29
and 30.
Over Gypsum Tile
Application of asbestos cement shingles to roofs of precast gypsum tile.
having a slope up to 60, should be made with nails having not less than 2 in. penetration. When the slope of the roof is greater than 60 refer the . problem to the United States Gypsum Company's engineers for special study and recommendations.
The roof deck should be thoroughly dry or as nearly so as can reasonably be obtained. Square cut cement coated Naval bronze nails have proved their superiority after a large number oi tests on all types.
It is standard practice to use a sheet of water proofing felt between the gypsum roof deck and the asbestos cement shingles.
No. 29
No. 30
19]
ICATI0N 2TAILS
/'
NO. 100 HEXAGONAL
For instructions regarding preparation of roof deck and application of ... Waterproofing Felt on new or reroofing work, see General Application Details.
Hexagonal shingles must he lined up both hori zontally and vertically. It is advisable to start work at the center of the eaves line. Having found the
Measure for center ef-Eeve *A - h.
Roof board*
Thani with i-4-5 method, find ^8
center line of roof Ley ihinjlei/ j5 rLay, fint eave itarter
right end left from tin line./ fo |at c~ enter of eave under felt.
Cnelk guide line* to be / " .Start second starter shingle
parallel to eave line
" 1 at center line ever felt.'
/ ~ ' -.-T Vjteryooflng -
t1. . ..
Project shingle* : /'
' I'beyond gable / `
^edgeo
` ' *
x: >'a' -i A Project shingle* \~^
beyond-edge of roof
METHOD OF STARTING SHINGLES AT EAVES
-
No. 35 ..
,
center by measuring, snap a chalk line at right angles to the eaves as shown on Detail No. 35 to mark the center line of the roof. This right angle for the center line can be easily found by the 3-4-5 method as shown on Detail No. 35. Do not measure off a distance on the ridge equal to one-half of the - eaves- length and snap the line between theser two points, because roofs are often out of square. The ' center line would not be at right angles to the eaves and the shingles would not fit together as they should.
The first eaves starter shall be nailed to the -sheathing board under the waterproofing felt and
at the center of the eaves as shown on Detail No. 35. Work right and left from this shingle. Eaves
starters shall extend one (1) inch beyond the eaves
Waterproofing Felt
\ Snap c.njik line* -T . i^T ___t-^garallel_to_e*v_ _ j/
1 , .. . ,,
l/\ Mam ,;Y\ Bodij Yihmgles
Second Starter Singles/
-A . - A 0
X-v
'-Eave Starter Sr.nties | METHOD OF APPLYING STARTERS AND MAIN BODY SHINGLES
No. 36
.
and one (1) inch beyond each gablo end and are
always laid with the long dimension parallel to'the
eaves line.
One second starter shingle is laid at each side
of the center line of the rooL breaking joints, with
the eaves starter. A copper storm anchor is set be
tween each two shingles into the slot: in the cor
ners. The shingles are then nailed in place with the
lower edge flush with the eaves starter, using two
nails to each shingle in the holes provided.
It will be found of great assistance in speeding
up the work if horizontal chalk lines are snapped
on the roof for each course of main body shingles.
Lay the head of each course of shingles against this
line as shown on Detail No. 36. When using a 16-
inch shingle, allow 8 inches between lines. Several
vertical chalk lines should be snapped to the right
and left of the
*
center line and parallel to it
-- -- --1ch+'k /mr$ on /
---- A-#.W UVt
-
running through
the center of the eaves shingles.
=w~" .0VV*TStCeP--J"t T.a.il"w! / af,-,--L--_--_---_-
-------{.-ne-s.
Set storm anchor In slot
Place adjacent shingle
_
u/PUce ./^overlapping
/;..\ltorm arsdior
IfS&Sisi
nroou 0969
No. 38
METHOD OF INSTALLING STORM ANCHORS
No. 39
No. 40
110]
No. 41
LAYING OUT GUIDE LINES ABOUND OORMER No. 37
NO. 200 AMERICAN METHOD TAPERED
For instructions regarding preparation of roof deck
and application of .
Waterproofing Felt on new
or reroofing work, see General Application Details
--'USG Asbestos Cement Shingles.
Hie waterproofing felt along the eaves should be raised and then placed over the starters after they have been applied.
* Vatcrproafinj fait.
Roof Boards
VH Joints
Head lap riot less than 2"
v- Snap Chalk Guide Unes parallel to eaves -A'
Application of Starters
Snap a chalk line parallel with the eave, 8" from
the edge of the eave. Use portion of starter for first unit to break joints with first course of shingles above. Allow starter to project 1" beyond eave and rake line to form drip edge. Apply succeeding starters similarly spacing them approximately 3/16" apart. Nail securely in nail holes provided.
Application of First and Succeeding Courses
Apply full size shingle directly over the starter shingle with butt parallel with exposed eave edge of starter, continuing application of full size shingles and breaking joints with underlying starters and spacing shingles approximately 3/16" apart (See detail No. 44). Begin the second course with a half shingle and proceed with full size shingles for the
remainder of the roof, exposing each shingle 8" to
the weather and securing each shingle to the roof
deck with IV4" galvanized or copper needle point
nails, through nail holes provided.
Eave Starter: Shingle v.
Project shindies fat cables and eaves-^**
UNIFORM WIDTH SHINGLES '-"UNIFORM EXPOSURE
No. 44
Staggered Exposure and Random Width
USG American Method Tapered Shingles may be applied in random width or with staggered butt effect, or in combination. If applied in staggered
butt effect a.2" minimum headlap must be maintained
by one of two methods: A--For uniform width
shingles: Snap chalk lines 8" on center, lay top of shingles to line or not more than 1" above or below
line, but maintain a linear 16" between the butt of each shingle and corresponding shingle in second course below. B -- For random width or uniform width shingles: Snap chalk lines 7l/j" on center and lay tops of shingles to the line or not more than Vi" above or below line: or use lines 7" on center and keep within 1" above or below the lines. In either case a minimum 2" headlap will be maintained. Both "B" methods will require approximately 7% and 13% more shingles respectively. In laying random
width shingles at least a 2" sidelap should he main
tained over joints in the underlying course.
:V,; .i t ' - l.'-.ll .['WaterproofingFelt . :/ j Roof Boards
Head lapnot lest than 2" '.
Snap chalk'guide lines T_ ' : parallel to eaves;
Waterproofing Felt ' fj Roof Board
. y Head. lap riot less than 2
M Joints .
Snap Chalk Guide Lines'^ V:; ' parallel to eave* - ^ .
G100U 0970
mm
Eave Starter Shingle
Project shingles I*at eaves and gables----UNIFORM WIDTH SHINGLES - STAGGERED EXPOSURE
No. 43
Eave.Starter Shingle
Project shingle* Tat Jbio and eaves -
RANDOM WIDTH SHINGLES - UNIFORM EXPOSURE
[11]
No. 45
MTAIL
NO. 300 DUTCH LAP METHOD
USG Dutch Lap Shingles may be applied with
in hole provided and fasten the shingle, with a
~ or Vj lap. - In working from right to leit the eave starters and the shingles are reversed, bringing the
naiL Completely overlapping the first shingle, apply a full size shingle with storm anchor inserted through
. nail holes adjoining the side edge to the left hand
hole provided and insert additional storm anchor
instead of to the right hand. See detail No. -46.
in opposite hole. Press the shingle down firmly in
Eave starters shall be applied to overhang the eaves and gables one (1) inch. Each piece shall be
place when clinching storm anchors. Proceed in similar manner to opposite end of roof.
laid to lap the preceding piece approximately one*
The second course is startod with shingle' cut to
third (Vi) or one-quarter O/4) its length, depending ' two-thirds (Vi) or three-quarters (%) original width,
upon lap desired.
drilling additional hole adjoining head of shingle.
Shingles are applied to completely cover the eave starters. The shingles are provided With eight holes. As applied, five of the eight holes are used; three for shingle nails and two for copper storm anchors. See detail No. 46. New holes must be drilled: in cut shingles as required.
Insert copper storm anchor and proceed with appli cation in manner before described. The third course is started with one-third (Vi) or one-half (]/i) width shingle. The fourth course is started with two-thirds
(Vi) or one-quarter (V4) shingle and continue appli
cation alternating as described.
Starting at the end of the roof apply a shingle which has been cut to one-third (Vi) or one-quarter _ _
(V4) its original width. Insert a copper storm anchor
Butt shingles at ridges, hips and valleys as re
quired and finish roof with
Asbestos Cement
Ridge Roll or Dutch Lap Hip or Ridge Shingles.
-mv&-
Cut new For V5 Lap nail holes
Cut off4*? For '/4 Lap
CUT FIRST STARTER SHINGLE
l" Projection
/'Natl here
4} "T-37 |4r\ Protection
FIRST OPERATION
Neil j.here
t--'Qa--K--1-~
''///, ",
,, . e
CutOff
CutOffl
for
for t
V* tap
HLap
* .
CUT FILLER STARTER FOR 1st COURSE
Put anchor here Cont.^ Starter Course
fc<_t~Nail here-. .
I '* * 1
ZL
SECOND OPERATION
THIRD OPERATION
Nnte K*w nail and arv. tvn hole* Ime uc *n lap --
Anchor Cv second ishtnfilr ovic
' i '. Continue First vNatl hare j Course [of Sh/ntf les
Cl*eh anenarj
ht anchoe Nail here
hare % i
.
L,
FOURTH OPERATION-.
f*' --11*--'
Pi/t storm Cut anchorhere (off
Ne Hoi
J
- .1*'
*v. * Git New Off Holes .
J . *
Naff . '
for Vj Lap For Lap
*er*V
r'CUT END STARTER TOR2mv COURSE
I /-L.
also for 4th,
^Put storm
.6th. ath.ete,
and or here
courses.
, Apply End Filler as in operation No. 2 and repeat process
Note that nail hers I rests on top of shintfle y covrie belo, giving
spaemjt-for courses.-
i
NOtC --*: -
These drawing* thnv shingles/;
applied with* i '3 U?
**
Tsr V4 Up arpUj m same manner . *
using aiterr.a*# s^lof nail holes. / ,
M'alrrproofing Felt
j - Nad here
Roof
Boards
fifth OPERATION
.
For '/a Lap Line up holes in lap like this
.
i.
4*t '
Lap]
.i!
3-
SIXTH OPERATION
ZD-
A
Storm Anchor
Na*i thru Ltrr-i^ shmgleS .
1 1 *
* *
Anchor for
'-FP'"* .* V
shrtijjle ) .
-
For V3 tap
tine up holes tn lap like this
Nail- / el si-;
Anchor- .i..,
s
.. .. '
la'firjjf frnm Irft to right, turn shingle around
Shine le contains 8 holes--
5 of`these are used in laymg
DUTCH LAP SHINGLES
i
. 1 -- _
1
APPLICATION OF MAIN BODY SHINGLES
J- APPLICATION DETAILS
No. 46
IL 60 U00.lt)
if' iTTH'i hm-
jirvuwiui
Asbestos-cement Siding Shingle*--To apply straight
edge shingles, use IISU Shadow.Lock Attachment System.
Level a starter strip lor base course of shingles. When lop
leg of USU Shadow-Lock channel is placed over starter
Strip, it is automatically aligned, (ihauuel is fastened by
uniting Is" from top edge through starter strip (or
through shingle in succeeding courses) and
Weatii-
Eiovooo Sheathing into each stud. Use I I ga., 2" gal
vanized moling nails with 1 \a" heads. Uorncr pieces arc
applied Lv hist inserting them between the exposed legs
of the lower channel and the usliestos' siding. Al the top,
insert one leg ol the corner piece between the channel
and the siding. Applv next channel to the adjacent side of
the corner--over both siding and coiner.
fL&Vr.. Vv
rrr^;`:v-
//p^arid Asbestos . 97
'^(. ytf^.r .***/'
-.;........- '
Description
No. 950 Clapboard Siding
A siding material made of a combination of asbestos libers and porlland cement plus a baked-on mineral type coating, not unlike a vitrified enamel in appear ance, in.-iead of the ordinarily porous asbestos-cement surface. Glate,\ Asbestos-Cement Siding is die-cut and made with a wood-grain texture in either a straight edge or a wavy-edge butt, 5/32" thick in units 12" x 27". AL)AlTABI, to both new construction and re-siding.
Dimensions
Approximate Weight per Sqwari
Weather bpeivrt
Overlap
. Finish
Color - ... gV^.Shtfiglos por square
.
Conventional Construction--No special framing is re quired. It may be applied over wood, gypsum or insula tion sheathing.
Resists Moisture and Dirt--The special-coated sur
face collects less moisture and dirt than ordinary as-
bcslos-eemenl. Ordinary stains do not readily adhere to
surface. Glatex siding retains original freshness longer. I
Fireproof--The combination oi asbestos fiber and port
land cement provides a surface that will not hum and
i which helps protect framing against fire hazard.
Economical--Glatex siding never requires paint. It
No. 600 Wavy Butt Siding Shingle
is easily and economically maintained and provides "life-lung'' service.
Dirntmiom Approximate Weight per Squore
12' 2V * i/32' 175 Pounds
i Cleanoble -- Surface grime can he cleaned from
Weather Exposure '
lO'/i
Glatex siding by simply washing with soap and water.
Overlap
1 l/xw Maximum, 1 Vs* Minimum
If
Attractive--Indented wood-grain effect enhances beauty of Gi.atex siding.
Finish Color
Large Units--The 27" lung units mean fewer joints, it* Shingles per sqwore
I faster application and tighter walls.
tWA- Shingles per bundle
t THE GLATEX SMUDGE TEST
Wood-grain Texture
Satin White
SI 17
\ i
i %
4
Apply dirty ail or grease
Wipes off without penetrating surface
Surfoca is restored--no stains remain
ffO O d 0978
ASBESTOS SIDING .
Thare'a no malntananca with aabaatoa camanl shingles such at 6LATEX. Available in while and Ihraa paalel colora, they naad no paint, even undar Oklahoma's rigorous temparatura aatramaa. GLATEX ahinglaa ara easy to apply over aaiallng wood walla, bland equally wall with wood or maaonry.
n o o
o o
1I I