Document 6a3J7JKVBxoVmkqB5LDeo7go
676
CHAPTER 26
1958 Guide
Table 2. Dimensions and Properties op Copper Tube
(All Types Except DWV are Based on ASTM B-88)
Nom inal Size
Type
Diameter
O. D. I. D. In. In.
Wall Thick
ness In.
Surface Area Sq Ft/Lin Ft
O. D. I. D.
Section Abba Sq In.
O. D. I. D.
Area of Metal Sq In
Volume Gal/Lin
Ft
Weight* Lbs/Lin
Ft
Working Pres sure
psia
H Kc 0.375 0.305 0.035 9.0982 9.0798 0.110
Lc 0.375 0.315 0.030 9.0982 9.0825 0.110
n
K L
0.500 0.402 0.049 0.131 0.105 0.196 0.500 0.430 0.035 0.131 0.113 0.196
X K 0.625 0.527 0.049 0.164 0.138 0.306
L 0.625 0.545 0.040 0.164 0.143 0.306
H K 0.750 0.652 0.049 0.193 0.171 0.441
L 0.750 0.666 0.042 0.193 0.174 0.441
X K 0.875 0.745 0.065 0.229 0.195 0.601
L 0.875 0.785 0.045 0.229 0.206 0.601
1 K 1.125 0.995 0.065 0.295 0.260 0.994 L 1.125 1.025 0.050 0.295 0.268 0.994
m K 1.375 1.245
L 1.375 1.265 M 1.375 1.291 DWV 1.375 1.295
0.065 0.055 0.042
0.040
0.360 0.326 0.360 0.331 0.360 0.338 0.360 0.339
1.48 1.48
1.48 1.48
m K 1.625 1.481 0.072 0.425 0.388 2.07
L 1.625 1.505 0.060 0.425 0.394 2.07 M 1.625 1.527 0.049 0.425 0.400 2.07 DWV 1.625 1.541 0.042 0.425 0.403 2.07
2 K 2.125 1.959 0.083 0.556 0.513 3.56 L 2.125 1.985 0.070 0.656 0.520 3.56 M 2.125 2.009 0.058 0.556 0.526 3.56
DWV 2.125 2.041 0.042 0.556 0.534 3.56
m K 2.625 2.435 0.095 0.687 0.638 5.41
L 2.625 2.465 0.080 0.687 0.645 5.41 M 2.625 2.495 0.065 0.687 0.653 5.41
3 K 3.125 2.907 0.109 0.818 0.761 7.67 L 3.125 2.945 0.090 0.818 0.771 7.67 M 3.125 2.981 0.072 0.818 0.780 7.67
DWV 3.125 3.035 Q.045 0.818 0.796 7.67
w
K L
3.625 3.385 0.120 0.949 0.886 10.3 3.625 3.425 0.100 0.949 0.897 10.3
M 3.625 3.459 0.083 0.949 0.906 10.3
4 * K 4.125 3.857 0.134 1.08 1.01 13.3 L 4.125 3.905 0.110 1.08 1.02 13.3 M 4.125 3.935 0.095 1.08 1.03 13.3
DWV 4.125 4.009 0.058 1.08 1.05 13.3
5 K 5.125 4.805 0.160 1.34 1.26 20.7 L 5.125 4.875 0.125 1.34 1.28 20.7 M 5.125 4.907 0.109 1.34 1.29 20.7
6 K 6.125 5.741 0.192 1.60 1.50 29.4 L 6.125 5.845 0.140 1.60 1.53 29.4 M 6.125 5.881 0.122 1.60 1.54 29.4
DWV 6.125 5.959 0.083 1.60 1.56 29.4
8 K 8.125 7.583 0.271 2.13 1.99 51.8 L 8.125 7.725 0.200 2.13 2.02 51.8 M 8.125 7.785 0.170 2.13 2.04 51.8
10 K 10.125 9.44S 0.338 2.65 2.47 80.5 L 10.125 9.625 0.250 2.65 2.52 80.5 M 10.125 9.701 0.212 2.65 2.54 80.5
12 K 12.125 11.315 0.405 3.17 2.96 115. L 12.125 11.56, 0.280 3.17 3.03 115. M 12.125 11.611 0.254 3.17 3.04 115.
0.0730 0.0779
0.127 0.145
0.218 0.233
0.334 0.348
0.436 0.480
0.778 0.852
1.22 1.26 1.31 1.32
1.72 1.78 1.83 1.86
3.01 3.10 3.17 3.27
4.66 4.77 4.89
6.64 6.81 6.98 7.23
9.00 9.21 9.40
11.7 12.0 12.2 12.6
18.1 18.7 18.9
25.9 26.8 27.2 27.9
45.2 46.9 ` 47.6
70.1 72.8 73.9
101. 105. 106.
0.0374 0.0324
0.0695 0.0512
0.0887 0.0735
0.108 0.0934
0.165 0.117
0.216 0.169
0.268 0.228 0.176 0.163
0.351 0.295 0.243 0.205
0.532 0.452 0.377 0.288
0.755 0.640 0.523
1.03 0.858 0.691 0.435
1.32 1.11 0.924
. 1.68 1.39 1.20 0.67
2.50 1.96 1.72
3.50 2.63 2.30 1.58
6.69 4.98 4.25
10.4 7.76 6.60
14.9 10.4 9.47
0.00379 0.00404
0.00860 0.00753
0.0113 0.0121
0.0174 0.0181
0.0227 0.0250
0.0405 0.0442
0.0634 0.0655 0.0681 0.0684
0.0894 0.0925 0.0950 0.0969
0.157 0.161 0.164 0.142
0.242 0.247 0.254
0.345 0.354 -0.362 0:376
- 0.468 0.478 0.489
0.607 0.623 0.634 , 0 656
0.940 0.971 0.981
1.35 1.39 1.42 1.55
2.34 2.43 2.47
3.65 3.79 3.84
5.24 5.45 5-50
0.145 . 0.126
0.269 0.198
0.344 0.285
0.418 0.362
0.641 0.455
0.839 0.655
1.04 0.884 0.682 0.650
1.36 1.14 0.940 0.809
2.06 1.75 1.46 1.07
2.93 2.48 2.03
4.00 3.33 2.68 1.66
5.12 4.29 3.58
6.51 5.38 4.66 2.87
9.67 7.61 6.68
13.9 10.2 8.92 6.10
25.9 19.3 16.5
40.3 30.1 25.6
57.8 40.4 36.7
918 764
988 677
779 625
643 547
747 497
574 432
466 387 293
- 421 359 .289 --
376 316 255 --
352 295 234
343 278 220 -- 324 268 218
135 256 217 -- 307 234
30118
330 .
332.
334 .
Weight per foot is based od tube without couplings.
_
b Working pressure is based on the American Standard Code for Pressure Piping, published by the ASM
revised November, 1952 for plain end tubing (sweat joints).
,, 2*fm ~ D --0^tm
where P = allowable pressure, pounds per square inch.
,.;
s = 6000 psi allowable fiber stress, pounds per square in"*
<m = minimum wall thickness, inches.
D = maximum O. D., inches.
e Types K and L furnished in both hard and soft tempers, Type M in hard only. Standard straight lengths are 20 ft. Standard coils (H to 1H inch) are 60 ft.
Pipe, Fittings, Welding
677
copper and red brass pipe have, always been used in heating, ventilating,, and water supply installations, but the cost with standard dimensions for,threaded connections has been high.' The introduction of fittings which permit erection by soldering or sweating, allows the use of tube with.thinnerwalls than would be possible with threaded connections, thereby reducing the cost of installations.
COMMERCIAL PIPE DIMENSIONS
Commercial pipe dimensions are covered in the following specifications of the American Society for Testing Materials: (1) steel--ASTM A-120and A-53, (2) wrought-iron--ASTM A-72, and (3) copper tube--ASTM A-88.
Tables 1 and 2 are based on these specifications.
In addition to the specifications for these three materials, there are
A ABLE d. 1 ABLE OF* AVAILABILITY FOR STEEL TlPE
Material
Specification
Available Sizes (Inclusive)
Inches Diam.
Allowable Fiber Stress S* psi
Butt-weld Lap-weld Electric-resistance Seamless
A-120 A-53 A-120 A-53
A-53 Grade A A-53 Grade B A-53 Grade A A-53 Grade B A-120
to 4
M to 4 2 to 12 2 to 24 2 to 24 2 to 24 2 to 24 2 to 24 2 to 12
6,225 6,750 8,400 9,000 10,200h 12,75tf> 12)000 15,000 10,400
D -0.8 (fm -c)
See American Standard Code for Pressure Piping, pub lished by ASMS, revised November, 1952.
Where P -- working pressure, pounds per square inch. 8 -- fiberstress, pounds per square inch. tax = 0.875 x wall thickness, inches. D = O. D., inches.
c = joint factor = 0.05 for 1-in. and smaller size or 0.065 for larger than 1-in. size.
Din* welded pipe for applications where the temperature is below 650 F, and where
to bv
i*Un"er
c*asslhcation is subjected to supplemental tests and/or heat treatments as agreed
strati
purchaser* and whereby such supplemental tests and/or heat treatments demon-
Dinfr *>, q
characteristics of the weld to be equal to the minimum tensile strength specified for the
me o values equal to the corresponding seamless grades may be used.
standards for copper or red brass IPS, clay or concrete, and cast-iron pipe.
oP.is of the following specifications may be obtained from the American
\0Cfn\ w Testing Materials: (1) steel, wrought-iron and cast-iron--Series 'Jr C0PPcr and red brass--Series B, and (3) clay and concrete--Series C.
of , i ^
*he sizes available in each of the specifications and classes
th t i P1*36' Ncte that butt-weld is not available above 4-in. size and
i,a o
electric-resistance-weld, and seamless are not available be-
iow z-m. size.
in 'n Table 3 is the formula for allowable working pressures as given
facto6
Standard Code for Pressure Piping} In this formula is a
iurv *" C'
^ intended as an allowance for corrosion, mechanical in-
servat^11 < ac^ur3n tolerances, etc. At times this factor seems too con-
worHnVe' *0r ex^mPle, with 3^-in., Schedule 40, steel pipe, the allowable
ing in g ?r^?ur? i 314 psi. Yet this pipe is tested at 700 psi. The reason-
that affSta ls^*nS factor c which influences the working pressure, is
ter nominal use the pipe may not be as sturdy as it was at the time