Document 6Y46e7KOeVjJXLNz2g6Vj0mE

6 packaged oil-fired boilers American-Standard I A u g u ti, 1964 I f-,; . * =v- -ri." 2 V* *$3-.z-w: ;..- '--"S' i<- the new oii-nred -- -ecs''--c-nsrail. oackaaed with built-in The new cast iron APT meets the need for an oil-fired hot water boiler that can furnish, at low cost, the superior quality of hydronic heat and a dependable supply of domestic hot water to the modern home. The compact APT is available completely packaged with l = W=H-rated tankless coil in 4, 5, and 6 section sizes. I=B=R- approved ratings are in the important 95,000 to 165,000 Btu hr range. Installation is fast and easy, in new home or old. All controls are factory-mounted and pre-wired. Rugged cast iron sections, precision DH-5 Arcoflame burner, and ELIMINAIRE' design, further guarantee dur ability, economy and efficiency in operation. 1- lar.rrcis-combination light-sensing prim ary and triple immersion control is factorymounted and pre-wired. 2- water ne::er-provides ample supply of domestic hot water, I = W = H-approved ratings. 3- tost ;rc.1 it?;: ; '.-multiple pin-type pro jections extract maximum heat from flue gases. Sections are tested at 2!i times maximum working pressure. 4-tieancut pan:- -easily accessible onepiece panel permits cleaning of all flue surfaces without disturbing burner, con trols and accessories. 5- .acxet--smartly styled of sturdy steel in sparkling gray finish; fully insulated. 6- model DH-5 A; - .. -ner-with sling mounting, is specifically designed and adapted for use with APT boiler. EXACT- AIRE control and special turbulator and disc combination assure proper air-oil mix ture for clean, economical firing. 7- nsjlated s'.sei oss --firmly supports cast iron sections and encloses refractory com bustion chamber. ELIMINAIRE*. EXACT-AIRE and Arcoflame are trademarks of AR & SS. to system ELIMINAIRE -- a patented cost-saving American-Stand ard feature-is integrally cast into the left hand end sec tion on all APT boilers. The ELIMINAIRE' baffle diverts rising air bubbles directly into the expansion tank through a special tapping in the section. No external de vice is necessary to separate air and water. air eliminator baffle Patent No. 3.123.454 VEKB High-capacity Tankless Water Heater-is individually sized and factory installed as stand-- ard equipment on each APT packaged boiler. Specifically designed for forced circulation boilers, the copper coil fits into the extra large 5" nipple port at the top of the sec^10"' High l = W=H approved ratings are obtained y actual test in the boiler. 00309 crated dimensions boiler number dimensions (inches) H wL approximate shipping weight (lbs.) APT-95 APT-130 APT-165 46% 46% 46% 21 Vb 21V 21% 23% 27Va 30% 484 548 621 DH-5 Arcoflame burner shipped in separate carton. APT packaged oil-fired boilers are designed and built to comply with the American Society of Mechanical Engineer's Code, and bear their approval symbol. Ratings have been approved by the Institute of Boiler and Radiator Manufacturers. The Model DH-5 Arcoflame Oil Burner is listed by the Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil; complies with Com mercial Standard CS-75; and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts, and by the Department of State Police. State of Connecticut. ^American-Standard 00310 J packaged oil-fired boilers near boiler piping A return \ relief valve \ expansion tank .. Procedure for filling series loop Heatrim System: 1. Close all zone valves except zone to be purged. 2. Open boiler drain valve. 3. Open fill valve. 4. Close purge valve. 5. Vent air from boiler by manually opening relief valve. 6. Open second valve to be purged. Close first zone. After second zone is purged, open third zone valve and close second zone. Repeat for as many zones as in system. (Note: Always have one zone valve open.) 7. When all zones have been purged, close boiler drain cock. 8. When water appears at relief valve, release lever and allow to close. 9. Continue filling until pressure gauge reads approximately 12 Ibs./sq. in. Close fill valve. 10. Open purge valve. Note 1: Where multiple circuits are used without zone valves, square head cocks should be installed for balancing. These square head cocks can be shut off to purge each circuit in turn. Note 2: For a single loop Heatrim System, no additional vents, cocks, valves, drains, or other accessories are required-with one exception. If tankless heater is used and Heatrim is above the boiler outlet, a flow cneck valve must be installed to prevent gravity circulation. standard wiring diagram thermostat Nc 3 u . AMERICAN RADIATOR & STANDARO SANITARY CORPORATION 40 WEST 40TH STREET NEW YORK. N Y 1C018 li'So " AMERicAN-^Standard TRADE PRICE SCHEDULE APT PACKAGED BOILER-BURNER UNITS WITH TANKLESS HEATER Designed and equipped with controls for forced circulation. Pre-wired. factory assembled with jacket and crated. "Eliminaire" (cast-in air separator). Motors and controls regularly furnished for 115 volt, 60 cycle current. WATER packaged unit number gross !=B=R output Mbh l=B=R burner cepe city gph tankless heater number l=W=H rating net l=B=R rating Mbh net rating sq ft water Trade Price with standard equipment chimney size approx. shipping weight Packaged units with factory installed tankless heater. With R8182A Aquastat-relay combination, high limit, low limit and circulator control, light sensing constant ignition primary control. APT-95 APT-130 APT-165 95 .95 218 23/a 71.3 475 -$390.00 8x8x15 484 130 1.25 222 3-/4 97.5 650 430.00 8x8x15 548 165 1.60 230 33/4 123.8 825 490.00 8x8x 15 621 *Nozzle sizes, gph. 60* solid, furnished with APT packaged units: APT-95. 0.90; APT-130, 1.25; APT-165, 1.50. A Cal/ons of water per minute heated from 40F to J40F with 200F boiler water temperature. Standard equipment: Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. CB-52502 thermostat. Nozzle. Light weight insulating fire brick combustion chamber. lVi" circulator. Wiring harness. Draft regulator. Pressure and temperature gauge. ASME relief valve. Drain valve. Zone valve packages are available for APT units. For details and prices, see page 30, Price Book HH-5. Note: APT units are shipped with flush jacket and with all electrical controls (except ther mostat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft regulator, relief valve and thermostat are secured inside boiler crate. Units furnished only as listed above This Price List has been prepared for the convenience of American-Standard distributors and their trade cus tomers only The trade prices shown represent fixed markups over distributor prices to reflect reasonable selling and distribution expense and do not purport to represent actual prices prevailing in any particular market. 00312