Document 6Vx7Zzo8y79xqQpZYn3eLR9E
^Environmental Protection Department ``outh Charleston Plant
December 5* 1977
To: Mr. J. L. Worstell
cc: Mr. T. D. Epps Mr. C. E. Fry Mr. W. T. Gray Mr. M. E. Griffith Dr. R. W. Holland, Jr.
Mr. R. T. Kramer Mr. D. C. Macauley
Mr. J. R. Solce ykr. R. N. Wheeler, Jr.
Mr. H. L. Wise
From:
C. C. Armstead H. C. Jackson W. 0. Young
Subject: Monthly Ambient A^r Vln
dec 7 i977
R-N- wheeler,
Historical subject monitoring data and sampling network plot are attached.
The majority of samples collected this month continue to border on the limit reliable detection, (<0.01 ppmv). We continue to detect trace quantities of VCM In the community, however, and the analyses are suspect f r the following reasons:
(1) The gas chromatographic analytical method is not truly specific for vinyl chloride and Is subject due to potential interference from unknown compounds.
(2) We occasionally note detection of VCM/positive response by th flame ionization detector in samples collected "up-wind" from plant operations.
(3) We have observed consistant detection/response among samples . collected near auto traffic, e.g., the Red Head Service
Station south of the plant, on McCorkle Avenue.
We plan to verify suspected analytical interferences of either gasoline/auto emissions by collecting samples at greater distances from Plant 514 operations at a busy service station.
/nb
Attachment
ucc
034094