Document 6RvN03zLMnpjndyXKx170nmpE
Report No. A2230383390101001 Test Report
Page 1 of 4
Company Name shown on Report Address
CHANGZHOU XCF POLYMER MATERIALS CO., LTD. NO.999 DINGJIAN ROAD, DINGYAN TOWN, CHANGZHOU, 213025 CHINA
The following sample(s) and sample information was/were submitted and identified by/on the behalf of
the applicant
Sample Name
PTFE Fabric
Color
White
Sample Received Date
Aug. 1, 2023
Testing Period
Aug. 1, 2023 to Aug. 7, 2023
Test Conducted: As requested by the applicant. For details refer to next page(s).
Approved by
Hill Zheng
Technical Manager
Date
Aug. 7, 2023
No. R677508188
Centre Testing International Group Co.,Ltd.
CTI Building, Xing Dong Community, Xin'an Sub-district, Bao'an District, Shenzhen City, Guangdong Province, P.R. China
Report No. A2230383390101001 Executive Summary:
Test Report
Page 2 of 4
TEST REQUEST FDA 21CFR 177.1550 Perfluorocarbon resins
- Total extractives - Fluoride extractives
CONCLUSION
See test result(s) See test result(s)
************* For further details, please refer to the following page(s) *************
Test Report
Report No. A2230383390101001
FDA 21CFR 177.1550 Perfluorocarbon resins Total extractives
Test Method: FDA 21CFR 177.1550
Test Item(s)
Distilled water extractives 50% ethanol extractives N-heptane extractives Ethyl acetate extractives
Result
001 N.D. N.D. N.D. N.D.
MDL
0.5 0.5 0.5 0.5
Fluoride extractives Test Method: FDA 21CFR 177.1550
Test Item(s)
Fluoride extractives in distilled water Fluoride extractives in 50% ethanol Fluoride extractives in n-heptane Fluoride extractives in Ethyl Acetate
Result 001 0.11 0.06 N.D. N.D.
MDL 0.05 0.05 0.05 0.05
Remark: - MDL = Method Detection Limit - N.D. = Not Detected (<MDL)
Sample/Part Description
No. CTI Sample ID
1
001
Description White plastic
Page 3 of 4
Limit
3.1 3.1 3.1 3.1
Unit
mg/dm mg/dm mg/dm mg/dm
Limit 0.46 0.46 0.46 0.46
Unit mg/dm mg/dm mg/dm mg/dm
Report No.
Test Report
A2230383390101001
Photo(s) of the sample(s)
Page 4 of 4
Statement: 1. This report is considered invalid without approved signature, special seal and the seal on the perforation; 2. The Company Name shown on Report and Address, the sample(s) and sample information was/were
provided by the applicant who should be responsible for the authenticity which CTI hasn't verified; 3. The result(s) shown in this report refer(s) only to the sample(s) tested; 4. Without written approval of CTI, this report can't be reproduced except in full; 5. In case of any discrepancy between the English version and Chinese version of the testing reports (if
generated), the Chinese version shall prevail.
*** End of Report ***