Document 6RnyaJ77B2akD9NmqXEDj2Ze4

DIRECTIONS FOR TEST NQ0 14-29-41 SUBJECT: Viscosity of Liquid Aroclors METHOD*-^sa^oit UniTewairASMi) a:^ i*;Visoosity Us ^measure pr rsslstanoa to ilow. It if .measured byjbfclpfcima ne<&&$0:fjor o;' he^forcedT thru a tubeJ|H&5' ofchosenlength andihteraal diameter." fey theory -the viscosity - r" 1 -of a fluid is related tb the average distance between its molecules and to their average speed and their size* - :>- Apparatus Viscosimeter assembly with oil tube, bath, receiver, thermome-- ters, strainer, timer and pipet to meet all requirements of A3TM 068^88* The viscosimeter ncm in use is made by Erebs Elec, and Mfg. Co*, New York, purchased from aiil Greiner Co.* their 2-tube capacity $862. One tube -- on left hand -- has been certified by the Bureau of Standards*- , (? y . /f ' - Procedure .. ,, _ The viscosimeter is set up in accordance with manufacturers di rections using No. 20 motor oil for the bath. The procedure and method of reporting results are those described under ASTM. - -- . . I Care of Apparatus '? . , ... Maintain proper level of oil by occasional additions thru hole in front* When oil blackens dismantle, clean heaters, tubes, and ." " orifices, then refill with fresh oil* - - " J ^ Bath* At conclusion of test, open the contaot points until 1 or 2 inches apart so as'not to put undue strain on thermostatic con trol when bath cools. Put a few drops of oil in motor cups occasion ally* Keep outside of bath wiped free of oil or Arcelor. Cover with hood when not in use* j r Oil Tube* While still hot, remove all possible Aroclor from gal lery with pipet*,' When cooled to 7080% fill tube, and gallery wiffe ^a^l^a^l^^traehL^^a^ii^taa^^^D^thrtt orifice into beaheri: drain gallery with pipet and wipe irywith absorbent paper in such a' way that fibers cannot fall into the tube*. Repeat until clean* . Occasionally cover the leather plunger with sized thin paper "copy" sheets) and swab walls of tube before using cleaning fluid. This keeps walls polished. Cover oil tubes with lids when not in use. Orifice: Do not pass wires, strings, pipe cleaners, etc. thru the orifice. If a hair falls across orifice, remove with long handled forceps. If the orifice becomes clogged, dismantle apparatus to clean. DSW 330717 STLCOPCB4077361 f V. ; :ai.i Page Ho* 2 Test Ho* 14-29-41 -- Viseosity of Liquid Aroelors ^ v ;v ay> -y- ^ t r*l< .s f ' '*&'*'$\&-i? '^r'l i-d' *> V*. -* . ir ~ Calibration *47^g;5 ,. Cheek the timer occasionally for $0 second periods* Check bath thermometer -ftool'time totime. erf'orniance of viscosimeter Available for calibration is also an oil standard, called *Alpha 40% of the American Petroleum Institute* The oil is obtained from the office of Dr* T* O* Delbridge, The Atlantic Refining Co., 3144; Passyunk Are., Philadelphia at $5 per quart sample* Because such oil standards are subject to change they are checked annually* ABO-p ' 10/2/41 OSNN 3307^8 STLCOPCB4077362