Document 6RjDL7dkB0v9NLdOKrXB6Yd63
190
ASffltAS Guide And Data Book
PACIFIC NATIONAL
COMMERCIAL STEa dci^lEfc
mm
^ewAWEy
l` i
GENERATORS
"PS" SERIES 20-60 HJ.
This 3-pass, wet back, packaged generator is available completely assembled and fire tested. Burn ers arranged for gas, oil, gas/oil combination, or dnel fuel gas combination. Heating surface is based on 5 sq. ft per boiler horsepower. 15 PSI steam or 3075 PSI WWP.
PACKAGED BOILER-BURNER UNITS . . . SCOTCH BOILERS
"PS" SERIES 80-350 HJ.
In larger sizes the 3-paas, wet back generator is available with fall modulating burners arranged for all fuel gases, #2, #4, #5, #6 oil, or any combination gas and oiL #6 oil units available with a "Cold Start Package" con sisting of auxiliary #2 oil boiler, water jacketed suction bell and full compliment of operating controls. 15 PSI steam or 30-125 PSI WWP.
400 SERIES 324 to 2400 MBH SBI GROSS OUTPUT
Units are rated in accordance with SBI schedule 1; and are arranged for gas, #2 oil, or gas/oil combination. Completely automatic, forced draft burners eliminate high chimneys on most installations. 15 PSI steam or 30 PSI WWP.
800 SERIES 2009 to 22140 MBH SBI GROSS OUTPUT
This 2-pass, wet back unit has ample com bustion volume to receive rotary cup and atomizing oil burners, ring type gas burners, or combination burners. (Not included as std. equip.) The boiler is pressurized for forced draft firing. Wet back construction eliminates costly refractory replacements. 15 PSI steam or 30-75 PSI WWP.
BARE BOILERS
900 SERIES 1632 to 17990 MBH SBI GROSS OUTPUT
The Pacific-National 900 Series Scotch Type Natural Draft boiler, featuring low beat transfer and beat release rates. 15 PSI steam or 30-75 PSI WWP.
"CA" SERIES 1080 to 12,600 MBH SBI GROSS OUTPUT
This high firebox, 3-pass, one piece nnit suitable for oil, gas, stoker or hand fired applications. 15 PSI steam or 30 PSI WWP.
PACIFIC TYPE 1260 to 18,000 MBH SBI CROSS OUTPUT
The Pacific High Firebox boiler is a flexible unit with ample throat height for proper combus tion of oil, gas, or stoker firing. 15 PSI steam or 30-100 PSI WWP.
LO-SET
The Lo-Set boiler is designed to meet grade level and low headroom applications. Gas or oil firing. 15 PSI steam or 30-100 PSI WWP.
200400 SERIES 324 to 1800 MBH SBI CROSS OUTPUT
These intermediate size boilers are arranged for natural draft firingThey have exceptional low draft loss, reducing chimney height require meals. 15 Pol steam or
PLUMBING-HEATING-AIR CONDITIONING GROUP CRANE CO.
VAL5 NNWG PUMPS ELECTRONIC CONTROLS FITTW6S PLUMBING * MIMING AIR CONDITIONING WATER TREATMENT
P.O. Bo* 780, Johnstown, Pennsylvania
''flE-'-*' Catalog Data Section
191
WATSCO, INC.
Dept. AA-1
1800 WEST 4th AVENUE HIALEAH, FLORIDA, 33010
TWX 521-3040
AREA CODE 305
PHONE 887-3517
MANUFACTURERS of REFRIGERATION, AIR CONDITIONING and ELECTRONIC PRODUCTS
MAGNI-CHEK VALVES
U.S. Pat No. 2,646,071
T-OFF' ADAPTER
U. S. Pat Pend.
A NON-ELECTRIC MAGNETICALLYOPERATED CHECK VALVE ... NO
SPRINGS...NO BACK PRESSURE
Hermetically-sealed with a built-in 30 mesh strainer for maximum ef
ficiency. Special size valves, with or
without the strainer, may be made to specifications.
Not affected by soldering heat
Full port opening
No pressure drop
8 stock sizes for to 1%" 0. D. tube
0. D. tube
Spun from hard drawn copper tubing. Particularly recommended ' for use in reverse cycle systems. Flare or sweat connections Superior moisture adsorbency Available for all size units up to
7Yi ton
EXCLUSIVE FEATURE
All Blu-Dot dryers are factory sealed with a special cap, containing a blue dot As long as the dot remains blue, complete dryness in the dryer is guaranteed. A pink cap indicates moisture.
THE SMALLEST TAPPING VALVES
ON THE MARKET AND THE ONLY
ONES MAOE FOR ALL SIZE
REFRIGERANT LINES
A permanent hermetically-sealed
port for charging, discharging
and testing. Contoured to fit its
respective size line, the Access
Saddle Valve is brazed to any convenient portion of the suction
and/or discharge line.
Fits lines from
thru 4K"
0.D. Just 3 easy steps to install:
1. Braze valve onto tube 2. Insert piercing needle
-Part NO. cv-2G
3. Attach control valve (CV-1G, CV-2G or CV-3G) to pierce
SUGGESTEO O.E.M. USE tube. Attach Access Saddle Valve on refrigerant line of original
equipment for future servicing. Tube is pierced only
when servicing is required.
Request the new 1965 catalog. No. 26, for sizes and descriptions of all WATSCO quality products:
Accumulators Can Tap Valves Liquid Leak Detectors Tele-Spout Products Capacitor Testers Compressor Parts Door Gasket Notchers Tapping Valves Fin-Combs Hex Wrench Sets Quick Sealing Caps Strainers Terminal Seals Inside Replacement Terminals Dryer and Strainer Capillary Combinations Epoxy Kits
WATSCO's modem plant is completely equipped with automatic screw machines, cold forging equipment, con tinuous atmosphere brazing, plastic and die casting equipment, specification plating, plus a complete modem shop and tool room, and is available to serve your production requirements. Write for full details.and cost estimates,
inquiries will be promptly acknowledged.