Document 6RVnXOX67wBjkBMg0KXvYB16g

Monsanto COMPANY LOCATiON^v?iuC .X/'flLcvL name CAUj&sfyAsM: . CENTRIFUGAL PUMP PERFORMANCE DATA PS03/DFPT &//>> //o J Ct&Cv^A-rtjujfZ fus,)/3 function ,/Z)Co./\?g: dbAjTAsy-c3 A/-~ ___________ fco<Ls~/t f/tt+i SYO) /9eyD s?rut$/V ?~Q EQUIP. IOENT NO. 4/ / AUTH NO. /<ffcO PLANT k/6.< RY DATE J0"/6~ 7 APPD SHEET / OF / no. reqd / 7>r/?0o&/>i 'f/j-eore)** /!//;J- operation C&;T./rsUtOS /rFrfj component /)oboCJ-oS DUTY: Q INTERMITTENT [^CONTINUOUS MATERIALS HANDLED % UNI T5 NORMAL DESI GN HOURSPER YEAR REMARKS L IQ U ID TOTAL SO L1 D ^/gas ;'4. 0. / PUMPING TEMPERATURE, PT, 0 F VISCOSITY,/,-^ OAO (UNITS! @ P T VAPOR PRESSURE, PSIA, @ PT >, /<o CORROSION/EROSION: Q NEGLIGIBLE PROCESS DATA jsPGR@PT /'%> @ 60 F ----- @60 F @60 P ----- SOLI DS --* ^MODERATE | | SEVERE -- CRYSTALLIZING, TEMPF ------ To WT DENSITY ----- SIZE -- ESTIMATED PERFORMANCE REQUIREMENTS CAPACITY, USGPM: NORMAL__________ SjSO_______________ ; MAX DESIGN " ; CONTROL ALLOWANCE*' PUMP RATED CAPACITY (MAXIMUM DESIGN CAPACITY PLUS CONTROL ALLOWANCE), USGPM, STATIC HEAD @ PT, , <S> FT PIPE DIA, NPS: SUCTION 4 /! CONTROL VALVE PRESSURE OROP, PSI: -- ; DISCHARGE so PSI EQUIPMENT LOSS, PSI: f <5 PIPING LOSS, PSI: NC RMAL AVAI LABLE NPSH, FT: /& fO< '7 RATED TDH @ PT: //f S> FT -- PSI FROM PUMP CALCULATION SHEET NO,. ^,5 NORMAL NORMAL NORMAL -- -- RATED RATED RATED SYST EM CURV E. C ALCUL A TIONS FROM SHEET HO.~JijQQ /iV{(j*\CC> ) ; DR! VER S'ELEC MOTOR Q] TURBINE QOTHER "" PUMP DATA MATERIALS OF CONSTRUCTION: CASING AND NOZZLES Y'JtTIL? IMP ELLER D/fniz SHAFT,SHAFT SLEEVE . 2) CP, //?0>\j //?.*> j>-----------------------------------------------------------------------:__________ P-AG-K+NG !/<JCQ t> C-. Sv'C-ciCA TYAjE C0uh-ijsj&. <'-'W MECHANICAL SEAL HCST/>TQ*j .......... PACKING GLAND --Wl " ~ " >&)/.. D 0>j/.U//6. OuoAO />/? Saco >//-8 cS/J) coo! baseplate 7b/lOOr,.*? o Xifrrg SO AA AJoTa/.i /'ft i S/Oj-rc 2) tf./z SriJ /O CONSTRUCTION FEATURES REQUIRED FOR PROCESS OR PERFORMANCE CONSIDERATIONS: PCB-ARCH-EXT0372359 Monsanto COMPANY location0-25/660 CENTRIFUGAL PUMP CALCULATION SHEET WtOiT/DEPT. SJI-os PLANIs 77 <*> /0/?l>/4S*s/?lC ` yn EQUIP. NO.. AUTH NO.. /8oo BY AREA NO.. ATE 72* /6.-S7 APPD. SHEET. / -OF. CONDITIONS . . ' Material Pumped P.T. = Pumping Temperature /so gpm = Flow Rate: Normal______________ SO 2 Design 6/?<D S- Specific Gravity* /'38 Density /O'-O^ F , Ib/gal [L - Viscosity*/,J4 _____________;_Centipoise P^= Vapor Pressure* 4-S_______ mmHg' _______________ psia AP: Control Valve 28~P%sf/d:>DS\: Equip.. 1 psi Pipe (Material <Ssl/tfc*/ sCh or Wall Thk . r f // Nominal $ize___________________Ruction ^ ^ Discharge d, Actual ID, inches Ss? ].Suction S'60 S' Discharge *At Pumping Temperature a A /w v \/\a EQUIVALENT LENGTHS Enter Type and FactirrTor each valve or fit' Suction ting. Enter Number of each type, and line size. Multiply Factor x Size x Num Type Factor Number Feet ber and enter Feet equivalent length. See handbook for types not listed. Factors for Valves (open) and Fittings Gate 1.1 Plug Valve 1.5 90 I. r. or Weld ell 1.7 yyw M.L Oil. / /O Globe, Lift Check 28.0 Butterfly (6" & up) 1.7 Std Tee (on tun) 1.7 Wye, Angle, Diaphr 14.0 90 Std Elbow 2.5 Std Tee (side out) 5.0 Swing Check 11.0 45 Std Elbow 1.3 Length of straight pipe in feet /o L= Total Equivalent Length, feet FRICTION HEAD LOSS V1* (0.408) gpm/d1, feet per second fro. (y-osy Re (Reynolds Number) = (3162) gpmS/dp. . 4 Or? >t <o (s/^V^)(/-28 C^X'-v) /*= Friction Factor (See Appendix C of D14.2 Std 2) if Re <2100 omit this step. . , ["(Re < 2100) = 0.154 aV/d2 SI ' Xo)Rj)x 1/ *" Ah L(Re> 2100) = 18.63 fV'fd j feet f fluid per 100 feet equivalent length -------------- Type nuf> z5\l: Discharge Factor Number /-S 20 0) ft Feet /& 60 SD Suction 6-3 /&0 Q3Q <0/8 7 3.4 Discharge /C-O 236000 0/60/ 73-3 Total Friction Head Loss = Ahx L/100 x 1.15 (safety factor), feet of fluid / SUCTION AND DISCHARGE HEADS rf./t/Sl Suction Discharge SYSTEM HORSEPOWER (estimated) Vessel Pressure (psia x 2.31/5) f-ZQ Liquid Level (above pump +; below pump -) Static Head (above pump +; below pump -) (+) 50. if (+) SO-8 7 -o iSlilPlilll tn so. o gpm x TDH x 5 HP = 3960 x E(Note 3) Total Friction Head Loss (Plus Velocity Head. See Note 4.) Control Valve (Apsi x 2.31/5) (See Notes 1 and 2) Orifice (Apsi x 2.31/5) (See Note 2) Equipment (Apsi x 2.31/5) l8*2-3l'// 28 Suction Head Sum, feet of fluid, abs. Discharge Head Sum, feet of fluid, abs. (-) ho (-) -- (-) -- (-) -- 63 (+) 20 'O (+) 3 7< 0 (+) (+) 32-0. /S'hZf ZSg x//& x /- 73 HP = 3960 x 635 HP - 73:6 DYNAMIC HEAD Discharge Head Sum Suction Head Sum TDH - Total Dynamic Head, feet of fluid NPSH Suction Head Sum ; f Qtyg x P^p (mmHg x 0.045/5) or (psia x 2.31/5) /-ZQ NPSH Available, feet of fluid, abs. 1*9-4 - 43.4 // 6.0 43.6 _ -- 48- 4 NOTES 1. Assume control valve loss to be 70% to 100% of piping plus equipment friction loss for initial calculation. Consult instrument engineer for final selection. 2. Control valves and orifices not normally used in pump suction. . ' UMP SELECTION _ jnufacturer /)oQCo SlrlOj/ JT _j Model 5x2~/3 Type '/fvs-430 ieed / 7-0/0 tom: Imp Size // X// ; HP 630 Eff 60 % 2 SO TDH //6 ; NPSH. 6rr 3. Use combined efficiency of pump and drive. 4. See D14.2 STD;2, a guide for the use of this calculation procedure. . , REV NO. . A A A ES 95 (t/66) REVISION ' BY DATE APPD DATE PCB-ARCH-EXT0372360