Prtdvct . *1______ Monsanto Giibmigal, Company Anniston, Alabama Plant Laboratory STANDARD ANALYTICAL METHOD Method No.,__ 54.8 . AROCl<3R3_ AND_PYRANOLS, . REFRACTIVE INDEX 0AT1 ISSUED 5/SZ6L. SSHTCN SV K.W.K. pao __i_ APPROVED #T U.W.K. TkU Matbad |][] Suparsadas . Ravltas SCOPE In.lroolloo. U.ooj 0 _j6/.14/52 Thl* method describes the determination of refractive Index by uee of an Abbe' Model 3L refraetometer. EQUIPMENT See General Method G-3- SAFETY Aroclors and Pyranols are Irritating to the akin. The vapors of hot materials are irritating to the eyes and upper respiratory system. If accidental contact is made with the eyes, flush Immediately with large quantities of water for at least IS minutes and get Immediate medical attention. The higher Aroclors mutt be hot to pour, so be careful of thermal burns. DETERMINATION 1. Mix ths sample well. . g, Adjust temperature of conetant temperature bath to 25.0"c. 3. Place 1 or 2 drops of sample on the lower prl6m. A. Close the prism and allow sample to come to temperature equilibrium, 5. Proceed as under General Method G*3 Report refractive index at 2SC. to nearest 0.0001 unit. Clean the prism with benzene followed by acetone. Rote; See precautions for cleaning In General Method G-3. RONS 073505